Index. Flexcor Wire Mesh Grips K-1

Similar documents
Index. Flexcor Wire Mesh Grips K-1

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

TCI5125 Dusttight Grip " 1.50"NPT Ins

Wire Mesh Grip Families

Wire Mesh Grip Families

Wire Mesh Safety Grips

Wire Mesh. Flexible Cord. Liquid Tight Mesh Grips for Flexible Metal Conduit STR GT Series

SECTION Wire Mesh Safety Grips

Wire Mesh Safety Grips

Manufacturers of Quality Wire Mesh and Accessories. Support Grips Pulling Grips Splicing Grips Strain Relief Grips Deluxe Cord Grips Accessories

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Wire Management Products Index

Wire Mesh Safety Grips

Pulling & Support Grips

Kellems Wire Management Products

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

americanfittingscorp.com t: e:

DEMANDING CONDITIONS, DEMAND THE BEST!

cable installation AnD SuPPorT MADE A WHOLE LOT EASIER TRUSTED INNOVATION q4:17 v1.7

Non-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

L 5 L 4 X 6 ( ) ( ) F A X ( ) R E M K E. C O M

Cable Grips, Swivels and Accessories

Control Circuits Connectors Type SK & SKW Overview

STRAIGHT BLADE PLUGS & CONNECTORS

FIBER CONNECTOR SAFETY WARNINGS

AMERICAN FITTINGS Corporation

YOUR SPECIALIST AROUND CABLE AND WIRE. Catalog

Features. Track Length System Length Storage Length. Active Travel. System Depth Loop Depth Tow Trolley. Intermediate Trolley

Cam-Lok Single Pole Connectors

KJ Main Components - 120V 60Hz. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Spring-loaded cover seats against neoprene gasket.

General Cable Support Information

Control Circuit and Industrial Interlock

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Marine Engineering Exam Resource Review of Couplings

CS Fiber Optic Splice Case. Instruction

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

NFPA 70E 68! & CSA Z462

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

CABLE GRIPS & ACCESSORIES

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

4.2. Fittings Metal and plastic fittings with positive sealing against liquids and dust. Thomas & Betts

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Good for ABS applications. Temperature rating -87ºF to 150ºF (-66ºC to 66ºC) Temperature rating -87ºF to 150ºF (-66ºC to 66ºC)

Seismic Sensor Accessories SA, SV & ST 6000 Series

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Fulfilling your needs & Safe

Installation Instructions for LED Timing Light

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

EPIC CIRCON M23 Series

OSP Fiber Optic Cable

Its not just any pendant; its a resilient, hardened rubber station seasoned with over 30 years of industrial use and innovation.

Keeping. corrosion down FOOD & BEVERAGE SOLUTIONS. efficiency. and plant. & safety up. designed to be better.

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

60A & 100A IEC 309 Watertight pin & sleeve devices

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t

Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application

Heavy Duty Copper Battery Terminals

Choose molded-to-cable or fi eld-attachable styles. J-Series are available in red and black synthetic rubber for easy phase identification.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER


D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

16A & 32A IEC 309 Watertight pin & sleeve devices

Auxiliary Transmission Filter Kit

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

HOISTS RATCHET LEVER HOISTS

Caring for cables. Types of installation

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

60A & 100A IEC 309 Watertight pin & sleeve devices

Installation Instructions Table of Contents

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

Power Transfer Door Loops

Yale HOISTS. 414 West Broadway Ave. P.O. Box 769 Muskegon, MI PH: FX:

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

LOAD/ANTI TWO-BLOCK INDICATOR INSTALLATION MANUAL

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

EARTH WIRE FITTINGS 08

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

S/6EA CARRIAGE & ELECTRICAL INSTALLATION INSTRUCTIONS PART VI CARRIAGE ASSEMBLY ELECTRICAL WIRING PART III THE FESTOON RACKING ELECTRICAL HOOK-UPS

Design PTS6-XX SERIES

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

CONDUIT BODIES CONDUIT BODIES. Phone:

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

EXPANSION JOINT SELECTION GUIDE

Conduit Bushings for Rigid Metal Conduit and IMC

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Transcription:

Fittings available in male straight, female straight, 45 and 90 designs for fast installation in all kinds of applications. Corrosion-resistant, die cast aluminum fitting with watertight seal (Deluxe Cord ) protects connections from cable stress in damp applications. No special installation tools required. Non-corrosive, double-weave stainless steel mesh () supports the cable, absorbs stress caused by flexure and vibration, as well as controls arc of cable. Mesh readily expands for a wide range of cord diameters. CG610 Male Straight, Deluxe Cord s Index Rugged, easy-to-install and available in a wide range of sizes our Flexcor Wire Mesh, Cable-Pulling, and Cable-s are engineered to take some of the strain off of you. Device Page Number K-2, K-3 Product Description K-4 Split Lace & Rod Mesh Termination K-5 s K-6 Grips K-7 Liquid-Tight Grips K-8 s Standard-Duty, Closed Mesh K-9 s Standard-Duty, Split Lace K-10 s Standard-Duty, Split Rod K-11 s Heavy-Duty K-12 s Service & Bus Drop K-13 s Fiber Optic K-14 Pulling Grips Junior- & Light-Duty K-15 Pulling Grips Medium-Duty K-16 Pulling Grips Heavy-Duty K-17 Pulling Grips Multi-Weave K-18 Pulling Grips High Strength & Fiber Optic K-19 Pulling Grips Slack K-20 Selecting Properly Sized Pulling & s K-21, K-22 Pulling & s Strength Information K-23 K-1

Bus/Service Drop Liquid-Tight Conduit Grip (page K-8) Bus/Service Drop Liquid-Tight Conduit Grip (page K-8) Medium/Heavy-Duty (pages K-16, K-17) Service Drop For assistance in selecting, see pages K-21 K-23. K-2

High Strength Pulling Grip (page K-19) Bus Drop Deluxe Cord Grip Strain Relief AIR Heavy-Duty Underground Pulling Grip (page K-17 K-3

Application are used to support cable or conductor after it has been installed, pull electrical cable or conductor into place, provide strain relief at the point of wiring connections. Flexcor devices protect cables, relieve stress, and prevent cable pull-out from fittings and terminations. Product Description Available in four different attachments. Load is distributed over entire length of grip and will not injure cable. Attachments Double Eye Single Eye Offset Eye Locking Bail Eye Grip Fittings Male Straight Female Straight Male 45 Male 90 Prevents pull-out or damage to cable due to constant motion or flexing. Also for Liquid-Tight, hose and box connections. Pulling Grips Flexible Eye Rotating Eye Mesh Types Closed Mesh Split Lace Mesh Split Rod Mesh Assortment of rugged pulling grips available individually or in kits to make wire pulling easier. Product Description K-4 Available in three types and depends on availability of wire end.

Split Lace/Split Rod Attachments (for use where end of cable is not accessible) Split Lace Mesh Termination For Split Lace mesh termination, Flexcor single weave Split Lace grips are provided with an additional single lace, two laces are provided with each double weave Split Lace grip. Lace strands should be same material as the grip. Split Lace & Rod Mesh Termination 1 2 1. Wrap split mesh grip around cable. Start lacing at top or bottom end of mesh. Thread lace through first two loops of split mesh and pull through until the lace is centered at this point. Lace as you would your shoe, crossing laces before lacing the next two loops. 3 4 2. Leave a space between adjoining loops approximately equal to the width of one diamond of the mesh. 3. Twist ends of lace strands together at end of grip or tie in a knot. 4. Wrap ends of lace tightly around grip. Excess lace may be cut off. Split Rod Mesh Termination For Split Rod mesh termination, a weaving rod is supplied with each grip. The open mesh passes around the rod and matches up with the open mesh from the opposite direction. Split Rod support grips are quick and easy to use and reusable. 1. Wrap split mesh grip around cable. Thread rod through the open loops in a weaving motion, using end of the rod to engage loops. 2. A steady push and twist motion is required. Use other hand to bring mesh loops together so as to weave through them. 3. To remove, pull rod out. 1 2 3 K-5 Split Mesh Termination

Straight Male Liquid-Tight Grips Description Liquid-Tight grips are woven of stainless steel mesh with zinc plated steel or malleable iron bodies and nuts for corrosion resistance. They are used to connect liquid-tight flexible conduit to electrical enclosures to prevent conduit pullout. Each fitting is supplied with an insulated throat to provide conductor insulation and protect against damage by flexing, heat expansion and contraction. Liquid-Tight grips are recommended in the wiring of motors and any electrical enclosure where liquidtight conduit is subject to motion or strain. NOTE: Stainless steel mesh is not suitable for marine use. Straight Male 90 Male 45 Male NPT Mesh Catalog Number Catalog Number Catalog Number Size Length Liquid-Tight for Metallic Flexible Conduit STB38SF STB4538SF 3/8" 2.625" STB50SF STB9050SF STB4550SF 1/2" 3.875" STB75SF STB9075SF STB4575SF 3/4" 4.375" STB100SF STB90100SF STB45100SF 1" 5.25" STB125SF STB90125SF STB45125SF 1-1/4" 5.625" STB150SF STB90150SF 1-1/2" 5.75" STB200SF STB90200SF STB45200SF 2" 7.5" STB250SF STB45250SF 2-1/2" 9.625" STB300SF STB90300SF STB45300SF 3" 10.625" Liquid-Tight Grips K-8 90º Male 45º Male Straight Male NPT Mesh Catalog Number Size Length Liquid-Tight Grips for Non-Metallic Type A Flexible Conduit STBN38SF 3/8" 9" STBN50SF 1/2" 10" STBN75SF 3/4" 10.5" STBN100SF 1" 12" STBN125SF 1-1/4" 17" STBN150SF 1-1/2" 21.5" STBN200SF 2" 24" Straight Female Non-Metallic Straight Male