Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates Page - Jumpers Page - Test Plugs Page - General Accessories Page - Marking Systems Page - Specifications Page - NEMA/EEMAC Terminal Blocks Open Construction Blocks Page - Isolation Switch Blocks Fuse Blocks Voltage Indicating Blocks Panel Mount Blocks Page - NEMA Accessories and Technical Specifications Mounting Rails Page - Stacking Bridge Kits Page - End Anchors Page - Side Jumpers/Fanning Strips Page - Fuse Puller/Test Sockets Page - Marking Systems Page - Specifications Page - Finger-Safe Terminal Blocks High Density Fuse Blocks and Surge Suppressor Blocks Power Blocks Page - Programmable Controller Wiring Systems Page - Bulletin ControlLogix Page - Bulletin CompactLogix Page - Bulletin MicroLogix Page - Bulletin MicroLogix Page - Bulletin Flex Page - Bulletin H and S PowerFlex Drive Page - Bulletin SLC Bulletin PLC- I/O Wiring Conversion Systems PLC- Bulletin to ControlLogix Page - Modicon to ControlLogix Page - Signal Conditioners Page - Current/Voltage Page - RTD Page - Thermocouple Page - Line-Monitoring Page - Bridge/Frequency/HART Page - Universal Page - Information for this product line is available on the Industrial Controls Catalog website: www.ab.com/catalogs. Resistor Blocks, Voltage Indicating Blocks, and Electrical Component Blocks - Publication A-CAA-EN-P
Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method of wire connection. Their greatest advantage is the ability to land multiple wires to a single terminal, potentially saving panel space. Screw type blocks can often accept up to five solid or stranded wires per terminal. They also typically provide the best visual indication of the wire connection. Compared to screw type terminations, spring clamp terminations can be a significantly faster method of connection and can often reduce wire connection time by %. Because the wire is under constant tension from the spring clamp, spring type terminations also produce very favorable results in high vibration applications. Certifications UR, CSA UR, CSA Standards Compliance Product Types Product Selection IEC, CE Mini blocks Feed-through blocks Multi-conductor blocks Plug-in style blocks Grounding blocks Fuse blocks Two level terminal blocks Three-Level Sensor blocks Electrical Component blocks Isolation blocks IEC, CE Mini blocks Fuse blocks Feed-through blocks Grounding blocks Multi-circuit blocks Plug-in style blocks Isolation blocks Sensor blocks Electrical component blocks Page - Page - Certifications Allen-Bradley terminal blocks generally have been designed to meet the requirements of one or more regulatory bodies. Most products have also been tested per additional standards. The following is a listing of some of the regulatory bodies and standards which apply to Allen-Bradley terminal block products. See the particular product description for information on specific certifications and ratings. (Underwriters Laboratories) Devices in this catalog with one of these ratings have been tested by Underwriters Laboratories and meet the requirements of one or more of the following United States Standards: UL Grounding and Bonding Equipment UL E Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors UL Standard for Terminal Blocks Reference UL files E, E, E (Underwriters Laboratories) Devices in this catalog with this rating have been tested by Underwriters Laboratories and meet the requirements of the following Canadian Standard: CSA. No. Terminal Blocks Reference UL file E (Canadian Standards Association) Devices in this catalog with this rating have been tested by the Canadian Standards Association and meet the requirements of the following Canadian Standard: CSA. No. Terminal Blocks Reference CSA files LR Terminal blocks listed in this catalog meet the requirements of the Low Voltage Directive put forth by the European Union. Devices have been tested and comply with one or more of the following European Norms: EN - Low Voltage Switchgear and Controlgear: General Rules EN -- Low Voltage Switchgear and Controlgear: Terminal Blocks for Copper Conductors EN -- Low Voltage Switchgear and Controlgear: Protective Conductor Terminal Blocks for Copper Conductors EN -- Low Voltage Switchgear and Controlgear: Safety Requirements for Fuse Terminal Blocks ATEX Devices listed in this catalog with ATEX ratings meet the following European Norms per DEMKO or KEMA, Approval Certification Bodies for the European Union: EN - Electrical Apparatus for Potentially Explosive Atmospheres General Requirements EN - Electrical Apparatus for Potentially Explosive Atmospheres Increased Safety e Contact your local Rockwell Automation sales office or Allen- Bradley distributor for a copy of the certificate. Publication A-CAA-EN-P -
Bulletin Certifications/Introduction Ex e II Many -J, -K, -L, and -W terminal blocks in this catalog meet the following Canadian Standards per Underwriters Laboratories: CAN/CSA E - Electrical Apparatus for Explosive Atmospheres Part General Requirements CAN/CSA E - Electrical Apparatus for Explosive Atmospheres Part Increased Safety e These products are suitable for Class I, Zone Hazardous Locations. Reference UL file E. Contact your local Allen-Bradley distributor for more information. AEx e II Devices listed in this catalog with an AEx e II rating meet the following United States Standard per Underwriters Laboratories: ANSI/UL - and - Standard for Electrical Equipment for Use in Class I, Zone,, and Hazardous (Classified) Locations These products are suitable for Class I, Zone Hazardous Locations. Reference UL file E. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for more information. Lloyd s Register Many -H, -J, -L, and -W terminal blocks in this catalog have been certified for use in marine, offshore, and industrial installations per the following standard: Lloyd s Register Test Specification No. : Contact your local Rockwell Automation sales office or Allen-Bradley distributor for a copy of the certificate. The Allen-Bradley Line of IEC Terminal Blocks International Products for a Worldwide Marketplace The Allen-Bradley Bulletin -J line of internationally approved IEC style terminal blocks offers a wide range of features and benefits ideally suited for many industrial applications. The -J line has been designed to meet the tough requirements of almost every industrial application. Functional, internationally approved, finger-safe, and cost-effective the Allen-Bradley Bulletin -J line. Products Available in the Bulletin Screw Terminal Block Line Our family of IEC terminal blocks consists of many different types of blocks, from general feed-through terminal blocks for control wiring to specialty blocks for grounding and isolating. We even offer thermocouple terminal blocks, specifically designed for temperature-dependent process control applications. Products offered within the Bulletin Screw Terminal Block line include: Feed-Through Blocks, capable of accommodating # / (. mm) wire Grounding Blocks for grounding a given circuit to the DIN Rail Mini Blocks for applications where panel space is at a premium Two-Level Blocks that double circuit wiring density Multi-Conductor Blocks that allow splitting or joining of control circuits Three-Level Sensor Blocks for coordination of three-wire sensor groups Isolation Blocks for circuit isolation during testing and troubleshooting Fuse Blocks, with and without blown fuse indication, for easily integrated overcurrent protection Electrical Component Blocks that allow the insertion of fixed components into control circuits. Available components include resistors, diodes, surge suppression circuits, and shunt bars. - Publication A-CAA-EN-P
Tie-Point Block (Cat. No. -JDC) Incorporates a shunt bar between the upper and lower current bars to provide a common point among all four terminals. Bulletin Diode Block (Cat. Nos. -JDDF, -JDDR) Introduction Uses a N diode between the upper and lower levels for insertion into a control circuit. This block is useful in low voltage DC control circuits for directioning and suppression. N -Pole Tie-Point Block Cat. No. -JDDF Cat. No. -JDDR Surge Suppression Block (Cat. No. -JDSS) Provides a convenient means of incorporating transient suppression for relays, contactors, and solenoids into a control system. Resistor Block (Cat. No. -JDRB, -JDRC) Permits the introduction of a Ω. MΩ resistor into a control circuit. V AC/DC Line Coil Surge Supp. (MOV) Return Blocks that have both terminations on the same side of the terminal block allowing the rail to be mounted next to the wall of an enclosure Plug-In Style Blocks that allow the insertion of removable plugs into control circuits. Available plugs include a Disconnect Plug, a Fuse Plug, and a Component Plug which will accommodate various electrical components. Thermocouple Terminal Blocks (Types B, E, J, K, N, S, T) for temperature control applications A wide variety of Snap-In Markers for individual or group circuit identification Multi-pole insulated Center Jumpers which provide a convenient method of commoning control circuits Materials and Design Features The Bulletin -J line is designed for safety, installation ease, and ruggedness. Features using these design criteria include the following: Tin-plated terminals and steel screws for corrosion resistance (Bulletin -W terminal blocks have nickel-plated terminals and stainless steel screws) High copper content copper alloy for excellent conductivity Four-sided wire funnel guides for easy wire insertion Finger-safe housings to prevent accidental contact with live circuits International approvals for worldwide use DIN Rail (Cat. No. -DR) mountability, allowing terminal blocks to be placed on the same channel as contactors, starters, relays, and other DIN Rail-mounted control devices Self-extinguishing, polyamide. housing material with UL -V flammability rating (Bulletin -W terminal blocks have UL -V flammability rating) Backed out screws for fast wiring Publication A-CAA-EN-P -
Bulletin Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -J -J -J." ( mm)." (. mm)." (. mm)." ( mm)." (. mm)." (. mm)." ( mm) Specifications Feed-through terminal block Feed-through terminal block Feed-through terminal block Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating V AC/DC V V V V V V V AC/DC V AC/DC Maximum Current A A A A A A A A A A A Wire Range (Rated Cross Section). mm mm mm # #. mm # # (# mm (# # mm (# ) ) ) Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque.. lb in (.. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Cat. No. Qty. Cat. No. Qty. Cat. No. Qty. Color: Grey -J -J -J Red -J-RE -J-RE -J-RE Blue -J-B -J-B -J-B Black -J-BL -J-BL -J-BL Green -J-G -J-G -J-G Yellow -J-Y -J-Y -J-Y Orange -J-OR -J-OR -J-OR Brown -J-BR -J-BR -J-BR White -J-W -J-W -J-W Violet -J-V -J-V Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBJ -EBJ -EBJ Blue -EBJ-B -EBJ-B -EBJ-B Yellow -EBJ-Y -EBJ-Y -EBJ-Y End Anchors and Retainers: DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Screwless End Retainer -ERL -ERL -ERL Jumpers: Screw Center Jumper -pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- -CJJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- (-pole) Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Insulated Side Jumper -Pole -SJB- Insulated Side Jumper -Pole -SJB- Screw Type Jumper Notching Tool -T -T -T Other Accessories: Partition Plate -EBJ -EBJ -EBJ Test Plug Socket -TPS -TPSL -TPSL Test Plug -TP -TP -TP Test Plug (Stackable) -TPJ -TPJ Electrical Warning Plate -EWPJ -EWPJ -EWPJ Marking Systems: Snap-in Marker Cards." (. mm) -MX (/card) -MX (/card) -MRX (/card) -MX (/card) -MX (/card) -MX (/card) Use of center jumpers may affect spacings, requiring derating of terminal blocks. See page - for details. - Publication A-CAA-EN-P
Bulletin Specialty Feed-Through Blocks." (. mm) -JQ -JTW -JTW Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." (. mm)." (. mm)." ( mm)." ( mm)." ( mm) Specifications Feed-through terminal block with Feed-through terminal block with connection Feed-through terminal block with connection points on each side points, on one side connection points, on one side Certifications CSA IEC CSA IEC ATEX CSA IEC Voltage Rating V AC/DC V V V V V AC/DC V AC/DC AC/DC AC/DC Maximum Current A A. A A A Maximum Single Side A A. A A Current Twin Side A A A Wire Range (Rated Cross Section) Single Side # # Twin Side." (. mm). mm # #. mm. mm. mm (# ). mm (# )." ( mm) # Wire Strip Length. in. ( mm) Single Side:. in. ( mm) Twin Side:. in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m) Single Side:. lb in (. N m) Twin Side:. lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Insulation Temperature Temperature Range Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Terminal Blocks Cat. No. Qty. Cat. No. Qty. Cat. No. Qty. Color: Grey -JQ -JTW -JTW Red -JQ-RE -JTW-RE Blue -JQ-B -JTW-B Black -JQ-BL -JTW-BL Green -JQ-G -JTW-G Yellow -JQ-Y -JTW-Y Orange -JQ-OR -JTW-OR Brown -JQ-BR -JTW-BR White -JQ-W -JTW-W Accessories Cat. No. Qty. Cat. No. Qty. Cat. No. Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBJ -EBJ -EBJTW Blue -EBJ-B -EBJ-B Yellow -EBJ-Y -EBJ-Y -EBJTW-Y End Anchors and Retainers: Screwless End Retainer -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAH -EAH -EAH Jumpers: Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Plug-in Center Jumper -Pole (- JTW)/ -Pole (-JTW) -CJLJ- -CJLJ- Plug-in Center Jumper -, -, -, -, -, -Pole -CJLJ-, -, -, -, -, - mm -CJLJ- Plug-in Center Jumper -, -, -Pole -CJLJ-, -, - -CJLJ-, -, - Insulated Side Jumper -Pole -SJB- -SJB- Insulated Side Jumper -Pole -SJB- -SJB- Screw Type Jumper Notching Tool -T -T Other Accessories: Partition Plate -EBJ -EBJ Test Plug Socket -TPSL -TPSL -TPSL Test Plug -TP -TP -TP Test Plug (Stackable) -TPJ -TPJ Marking Systems: Snap-in marker card Use of center jumpers may affect spacings, requiring derating of terminal blocks. -MX (/card) -MX (/card) -MRX (/card) -MX (/card) -MX (/card) -MX (/card) - Publication A-CAA-EN-P
Bulletin IEC Terminal Block Accessories General Accessories Plugs and Other Accessories Test plug sockets fit into the center bridge screw hole and allow easy connection of test plugs for circuit testing and troubleshooting. Test Plugs Spring-Clamp Terminal Blocks - -pole Quick Connection Euro style plugs. Operating Instructions Spring-Clamp Terminal Blocks Cat. No. -QCLABEL is an adhesive set of visual operating instructions that is intended for installation on the inside of a panel. It illustrates to maintenance personnel the correct operation of Spring-Clamp terminal blocks. Insulation Stops Spring-Clamp Terminal Blocks Protective insulation stops prevent the insulation on conductors from being introduced into clamp and current bar area. Test Plug Sockets, Test Plugs, Test Plug Adapters, and Test Adapters Sockets Qty. Cat. No. Test Plug Adapters Qty. Cat. No. -TA -TA -TAL -TPLP -TPS -TPSL -TPSL Required for testing Cat. No. -J products with Cat. -TP or -TP test plugs. Test Plugs Qty. Cat. No. -TP Test Plugs (Stackable) Marker cover screws. Markers Qty. Cat. No. -MX, MX -TPJ -MX, MX -TPJ -MX, MX -TPL -MX, MX -TPL -MX, MX -TPL -MX, MX -TPL -TP -TP -TPCBM -TPCMB Used in conjunction with Cat. No. -TPS or -TPSL test sockets. Used in conjunction with Cat. No. -TPSL socket. Used in conjunction with Cat. No. -JCTB terminal block. Publication A-CAA-EN-P -