Main switches in accordance with European standard directives

Similar documents
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

PowerLine OS Switch Fuses A, 690V

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

The Modular System. Modular System

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical information No. 01. IT systems. The basis for reliable power supply

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

BETA Switching Switches and Light Indicators

Outdoor vacuum breaker for railway applications - FSK II

NH-Fuse system Low voltage

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

CONTROL CONSOLES FAMOR S.A. UL. KASZUBSKA BYDGOSZCZ POLAND

INTERNATIONAL STANDARD

IEC Low Voltage General Purpose Protection

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SIRCO M and MV Universal load break switches from 16 to 160 A

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Unified requirements for systems with voltages above 1 kv up to 15 kv

Power stability for manufacturers

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

Motorized switch-disconnectors OTM 40 to 125 Amperes

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

INTERNATIONAL STANDARD

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

COMMISSION REGULATION (EC)

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

1489-M Circuit Breakers

SG-B1 SERIES / SG-A1 SERIES

MINIATURE CIRCUIT BREAKER

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

(Non-legislative acts) DECISIONS

Phase + Neutral, neutral on right side

Medium voltage products. Technical Application Papers No. 16 Electrical safety in medium voltage plants

Selection Guide Motor Control Device Solutions

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V

Vistop TM isolating switches 63 to 160A

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

SWITCHGEAR. 4G cam switches

AS/NZS AS/NZS

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

Gas Insulated Metal-clad Switchgear, HMGS!

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Item 1: Contents of the complete training & CV of the lecturer

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Low Voltage Products. ABB Building Technologies. PowerLine OS and OESA Switch Fuses. Brochure OS-OESA 1 GB 00-05

IEC Low Voltage Products Module 4

CEN/TC 198. EN :2005/FprA1:2010. Date: CEN/TC 198. Secretariat: DIN

TEKNISK RIKTLINJE TR05-10E

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Phase + Neutral, neutral on left side

General Informations 2 Technical data 3 Basic designs 4-8

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

High Reliable Components for Power Factor Correction and Power Quality

Appendix: Safety and application notes for... 15

In general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

INTERNATIONAL STANDARD

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

INTERNATIONAL STANDARD

D o o r I n t e r l o c k s

DSE201 Compact design with enhanced protection

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Scheda prodotto Relè Series B

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Flexible. Intelligent. Trendsetting.

INTERNATIONAL STANDARD

Council of the European Union Brussels, 18 July 2014 (OR. en)

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Low Voltage Apparatus. Technical Brochure. BaseLine. Fuse Bases OFAX, OFAS_ 690 V. Brochure OFA 1A GB 91-02/ 95-11/97-03.

Miniature Circuit Breaker

Installation Instructions

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

All round protection guaranteed

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Transcription:

Main switches in accordance with European standard directives N N ABB y

ABB Switches in accordance with EU Directives New concept n order to dismantle technical barriers in commerce, the Council of the European Union released at the suggestion of the European Commission EUstandard directives based on article 100 of the Uniform Acts. The European Commission formulates these standard directives in accordance with the so-called New concept. Up to now the EU-standard directives included only requirements of a general nature. To fulfil these rather general essential requirements the European Commission shall assign to the European Standardization rganizations CEN, CENELEC and ETS a task of stipulating the European standard directives, which shall be considered as harmonized standard directives. Advantages for manufacturer The usage of harmonized standards give the manufacturer the advantage of assumption reaction, which means that the product can be assumed to fulfil the essential requirements of the EU-standard directive. f the manufacturer doesn't use any harmonized standard e.g. concerning low-voltage, he must prove by technical demonstration that the requirements are fulfilled. Harmonized standards in accordance with the EU - standard directives Safety of machinery - Electrical The standards covering the safety of electrical equipment are subdivided into three categories as follows: A. General safety standards are valid for all machines and devices: Safety of machinery, EN 292 EMC-directives, EN 50065 Risk assessment, EN 1050 B. Group safety standards orientated to particular aspects of safety and safety-related equipment. PrEN 1047 Protection against restarting is under consideration. C. Standards for safety of machinery include specified safety requirements for particular machines and groups of machines: EN 0529 housing classes The European Committee for Electrotechnical Standardization (CENELEC) has stipulated the following European norms (EN), harmonized documents (HD) and European Magnetic Compability directives (EMC) for switches. They are valid in their area of use as acknowledged European technical rules uniform throughout all CENELEC member countries, which means the European economic region. They have a status of a national standard. Conflicting national standards shall be withdrawn. Disconnector solation class V Disconnector solation class N N Safety standards for machinery Safety of machinery referring to the status of a harmonized standard can be subdivided into the following cases: 1. Harmonized general standards under the EUstandard directives in accordance with the new concept covering e.g. EMCdirectives and the standard of machinery. 2. Harmonized standards under the Low Voltage Repair disconnector Safety disconnector solation class V 2 N N

ABB Switches in accordance with EU Directives equipment of machines-en 60204 Standard for machinery EN 60204-1 This part of EN 60204 is the first part of a series of standards relating to electrical equipment of machines, and specifies general requirements for the electrical equipment of an individual machine, as well as a group of machines operating in a coordinated manner. This part of European Standard EN 60204 provides requirements and recommendations relating to electrical equipment of machines in order to promote the following matters: safety of persons and property control of function capability ease of maintenance ease of service and repair Application of switches according to the standard EN 60204-1 Application area This standard considers the application of machines under normal conditions. Care must be taken that the break switches correspond with the requirements for warmth, quality and humidity of air. General considerations Risks associated with the hazards relevant to electrical equipment shall be assessed as part of the overall requirements for risk assessment of the machine (Paragraph 4.1.) Hazards can include for instance the following: failures or faults in control circuits disturbances or disruptions in external power sources as well as failures or faults in power circuits resulting in the malfunctioning of the machine electrical interferences either from outside the electrical equipment or internally generated perating conditions for disconnectors Safety Switch The standard specifies in paragraph 4.3., Electrical supply, the operating conditions for a disconnector: Voltage: 0,9..1.1 of nominal voltage Frequency: 0,99..1.01 of nominal frequency Harmonics: harmonic distortion (for the sum of the 2nd through the 5th harmonic) is not allowed to exceed 10% of the total r.m.s. voltage N N Voltage impulses: Max. duration 1,5 ms Max. peak value 200% of the rated r.m.s. voltage Voltage interruption: Supply interrupted at zero voltage for not more than 3 ms. There shall be more than 1 s between successive interruptions. 3

ABB Switches in accordance with EU Directives There must be a switch disconnector! (EN 60201-1) A hand-operated main switch disconnector shall be provided for each incoming supply. When two or more main switch disconnectors are provided, protective interlocks shall be used where a hazardous condition or damage to the machine or to the work in progress could occur. solation function - the new way to think The need for a clear isolating function increases as more and more conductor systems, remote control devices and electric apparatus are introduced. The main switch is required because it is necessary to have reliable protection against unintentional start-up during cleaning, maintenance and repair, as well as during longer pauses in usage. The switch-disconnector is also required for prevention of unexpected start-up for example in the case that the start-up of a machine during the work in progress could create a hazard. A main switch disconnector fulfils these functions best. The isolating characteristics are the most important items within a machine standard direction. For the switch disconnectors the standard EN 60947-3 is valid. All live conductors shall be isolated from their electric network. However it is possible in TN-supplynetworks to isolate the neutral conductors (EC364.4). Precautions shall be taken to prevent unintentional or inadvertent operation of the disconnecting device. Physical environment and operating conditions Pollution degree solationclass V Rated impulse withstand voltage Uimp (kv) Air gap (mm) New requirements for main disconnectors The main switch disconnector shall be a switch disconnector according to EN 60947-3 for application category AC 23B or DC 23B and shall have a breaking capacity sufficient to interrupt the current of all supplies in use at the same time. Position indication (or visible isolating distance) N The main switch disconnector shall have a breaking capacity sufficient to interrupt the current of the largest motor when stalled, together with the sum of the normal running currents of all other motors and/or loads. The main switch disconnector shall reliably isolate the electrical equipment from the supply. t shall have one and one N position only, clearly marked with 0 and. The new way to think: definition of isolating function According to EN 60947, the rated impulse withstand voltage Uimp of the main contacts shall exceed the one stipulated for the corresponding installation class of EC 644. The standard requires an isolating distance of the contacts corresponding to the isolation class. The old definition of isolating distance as such will not be valid any more. According to EN 60947 the main switch disconnector shall correspond at least to class of EC 644. 4

ABB Switches in accordance with EU Directives Advantages of the ABB switch disconnectors SwitchLine, PowerLine and SafeLine The requirements of the standard EN 60947-1&7.1.6 for switch disconnectors As a well-known worldwide manufacturer of switches ABB has been active in developing new standard directives in order to make switches safer and more user-friendly. The switch disconnectors of the series SwitchLine, the switch fuses of PowerLine as well as the local safety switches of SafeLine clearly fulfil the requirements of the new European directives. ptimum disconnectors The mechanism of the load switches from 45 A up is constructed according to the principle Quick-make, quick-break. All switches are provided with a positive opening operation. The rated impulse withstand voltage and air gap exceed the requirements for disconnectors in isolation classes and/or V. The position indication is in all cases reliable. t is not possible to lock a handle of an ABB-switch in the 0 position, unless the required isolation is ensured. The rated impulse withstand voltage U imp not less than 8 kv is printed in the type plate. N Air gap 5

ABB Switches in accordance with EU Directives Position indication (definition) The position indicator cannot display the position, until all contacts are open - also the welded ones - and a sufficient air gap exists between all contacts according to EN 60204. Alternatively, a visible isolating distance may be employed, where practicable. t is recommended that the colours of an external operating handle are black or grey. Where the disconnector does not also serve as an emergency stop device, its operating handle may not be red. The handle of the disconnector shall be easily accessible and located between 0,6 m and 1,9 m above the servicing level; a maximum height of 1,7 m is preferred. N N N 45 o N N N N Reliable position indication protects the user in the following cases: The position of the handle indicates with complete reliability the exact position of the contacts in all circumstances. The position indicator in the switch body ensures the reliable position indication of the contacts in case of an open door. The visible isolating distance, where practicable, increases the safety of large switches. The position indication is also safe after several switch offs and short circuits. The handle can not be padlocked in the 0 position if one of the contacts is not in the position. The creepage current between the contacts does not exceed the following values with 10 % overvoltage: New switches: 0,5 ma After switch on/switch off tests: 2 ma Under no circumstances: 6 ma N N Padlocking of the handle t shall be possible to padlock the handle in the open () position. N N t shall not be possible to lock the handle in the 0 position if one of the contacts is not in the open () position. 6

ABB Switches in accordance with EU Directives Padlocking of disconnectors The switch mechanism is constructed so that neither the handle when turned to the position with a moderate power nor the separate position indicator can indicate the switch off position if one of the contacts has been welded together. N T40E3 N Positive opening operation of the contacts The mechanism of all switches works according to the so-called positive opening operation principle. This means that the contacts do not open by strings but by solid moving bridges. N Main switch N "Disconnector" Plates provided with text Disconnector are delivered as accessories. 7

N N T80E3 N N N N ABB Switches in accordance with EU Directives Versatile mounting possibilities of switches save space and allow easy installation Versatile mounting variaties of SwitchLine switch disconnectors and PowerLine switch fuses allow space saving and easy mounting for every application. The mounting variations include modular, base mounting and front door mounting. T16E3 N N The side wall is often a practical and space saving solution. Mounting on the door by snap-on technique saves time. N N TEST Minimum installation time with the help of system technology Mounting without screws and adapting mounting allow easy installation while the small dimensions help minimize the volume of a unit while optimizing the connecting. N N N FAM 1/aM 250A 34 42 54 64 N FAM 1/aM 250A 8

ptimum connecting technology ptimum connecting technology with protected terminal shrouds allows easy mounting and saves space needed for small switches. Concerning bigger switches the high blade terminal location allows easy mounting of double cables. That is why there is no need to additional spacions cable terminals. ABB Switches in accordance with EU Directives N The snap-on mounting of the protected terminal shrouds N The protected terminal shrouds, which are easily mounted by snapon technique, increase the safety level and do not require additional isolation space. 9

ABB Switches in accordance with EU Directives Easy mounting The uniform auxiliary contacts with snap-on mounting for the whole series decrease the storing and installation costs, which in turn decreases the costs of a mounted disconnector. The maximum amount of auxiliary contacts of a series is from 4 to 18 pieces depending on the type of disconnector. The base mounting shall be done by screws or by DN-rail fixing. 3 2 1 N 2 N 1 N Mounting on the door shall be done either by screws or by snap-on mounting in order to save installation time. Neither switch disconnectors or switch fuses need additional space for spark extinguishing. For this reason the switches offer the user more in the areas of connecting space, saving in time, safety and visibility. T16E3 N N Easy mounting The switch disconnectors can be easily installed in panels of different depths. (adjustable shaft of telescopic type) N Lower mounting costs Total costs Cost reduction Space Mounting Accessories Switches Traditionel switch New switch 10

N N N TEST N N N ABB Switches in accordance with EU Directives nternational switches of ABB for a world-wide distribution The international sales network of ABB takes care of our clients everywhere, where new or replacement switches are needed whether the requirements are of a European, international or American standard. The SwitchLine switch disconnectors and PowerLine switch fuses as well as SafeLine safety switches are international products. ur world-wide logistics and modern ED-contacts support our efforts to always see the client as the most important factor. UL/CSA EC/ KEMA The AAB switches correspond with the requirements DN-EN 60947-1 DN-EN 60947-3 DN-EN 60664-1 DN-EN 60204-1 EC 204-1 EC 947-1,3 EC 664-1 UL 508, 98 CSA C22.2 VDE 0660 Part 1 VDE 0113 Part 1 The series of the SwitchLine switch disconnectors fit for every standard distribution and motor control applications giving optimum value for money in every application. Rated current solation voltage Base mounting Door mounting Sidewall mounting Enclosed switches Approvals A 16 32 40 63 80 100 125 160 200 250 315 400 630 800 1250 1600 2500 3150 U n max V Safety Switch KEMA ASTA Underwriter Laboratories (UL) Canadian Standards Association (CSA) DEMK NEMK SEMK Finnish Electrical nspectorate Germanischer Lloyd Lloyd's Register of Shipping Polish Register of Shipping Det Norske Veritas Bureau Veritas 11

Environmentally-friendly new load break switches and packages Self-divergent plastic parts are used, where it is technically possible. Heavy metals are avoided in the production process. Cadmium is not used as contact material. Packaging is produced using recycled materials. ABB y P..Box 622 F-65101 Vaasa Finland Tel. +358 10 22 4000 Fax +358 10 22 45708