Products Stand-Alone-Systems POWERFUL TECHNOLOGY
Power Supply System SVS 48/60 V-0/00A SVS 48/60 V-60/00 A Type SVS-G48, 60/0-8GRS SVS-G48, 60/60-5GRS Rectifier RM 800 RM 800 Rectifier type E60/5 WBrug-GRM E60/5 WBrug-GRM Max. rectifier number 4 Control and monitoring unit SVS-SM7 SVS-SM7 Input ph or ph with N ph or ph with N Voltage 0 V / 400 V 0 V / 400 V Max. current per phase A 44 A Frequency 45 65 Hz 45 65 Hz Power factor cos φ, EN 6000-- cos φ, EN 6000-- Voltage selectable 4 V / 48 V / 60 V 4 V / 48 V / 60 V Max. current 0 A 60 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 5 x circuit breaker x 6 A x 50 A 7 x NH00 x circuit breaker Protection class IP0, EN 6059 IP0, EN 6059 Ambient temperature 0 to +45 C 0 to +45 C Without modules 4 kg 70 kg Fully equipped 66 kg 40 kg 650 x 600 x 500 000 x 600 x 500 SNMP-adapter Modem-signalling Temperature compensation 650 x 600 x 500 000 x 600 x 500 400 x 600 x 500 on request 4 V with suitable LVD to +55 C possible if ph
Power Supply System HPS 00 Wall 4/48 V-00 A HPS 400 Floor 4/48 V-400 A Type SVS-G48/00-GRW SVS-G48/400-GRF Rectifier HR 00 / HR 400 HR 00 / HR 400 Rectifier type E48/5 WBrug-GRM E48/5 WBrug-GRM Max. rectifier number 8 ( x HPU 500) 6 (4x HPU 500) Control and monitoring unit HPU-SM HPU-SM Input ph or ph with N ph or ph with N Voltage x 0 V / 08 V, x 0 V / 400 V x 0 V / 08 V, x 0 V / 400 V Max. current per phase 4 A A Frequency 45 65 Hz 45 66 Hz Power factor cosφ, EN 6000-- cos φ, EN 6000-- Voltage selectable 4 V / 48 V / 60 V 4 V / 48 V / 60 V Max. current 00 A 400 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 4 x circuit breaker (expandable) 4 x circuit breaker (expandable) Protection class IP0, EN 6059 IP0, EN 6059 Ambient temperature 0 to +60 C with derating > 50 C 0 bis +60 C with derating > 50 C Without modules 48 kg 76 kg Fully equipped 70 kg 8 kg 670 x 600 x 400 800 x 600 x 600 SNMP-adapter Modem-signalling Temperature compensation on request integrated battery compartment, max. levels per 00 Ah 4 V with suitable LVD to +55 C possible if ph
Power Supply System HPS 760 with BVS 800 SVS 48/60 V-50 A Type G48,60/760-GRS0 / BV48,60/800-BVS0 according implementation Rectifier HR 00 / HR 400 RM 8000 Rectifier type E48/5 WBrug-GRM / E60/ WBrug-GRM0 D60/50 WBrug-GRM Max. rectifier number (8 x HPU 500) 5 Control and monitoring unit HPU-SM HPU-SM Input ph or ph with N ph without N Voltage x 0 V / 08 V, x 0 V / 400 V 400 V Max. current per phase 88 A 40 A Frequency 45 66 Hz 45 65 Hz Power factor cosφ, EN 6000-- λ > 0,94 Voltage selectable 4 V / 48 V (HR00) 48 V / 60 V (HR400) 4 V / 48 V / 60 V Max. current 800 A 50 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 8 x NH00 TPS (400A) closed or -7 x NH00 closed or -8 x NH- open or -9 x NH00 open 0 x NH closed or - x NH00 closed or - x NH- open or - x NH00 open Protection class IP0, EN 6059 IP0, EN 6059 Ambient temperature 0 to +60 C with derating > 50 C 0 to +45 C Without modules 95 kg (HPS760) kg (BVS800) 0 kg Fully equipped 0 kg (HPS760) 80 kg BVS800) 59 kg 800 x 600 x 600 (HPS760) 800 x 600 x 600 (BVS800) 000 x 400 x 600 SNMP-adapter Modem-signalling Temperature compensation on request on request 4 V with suitable LVD to +55 C possible if ph
Power Supply System SVS 48/60 V-500 A FP Systems 600A Type according implementation FP Sytem 400Vac 48V 600A Rectifier RM 8000 FP 48V 000W Rectifier type D60/50 WBrug-GRM E48/4 WBrug-GRM Max. rectifier number 0 6 (expandable on request) Control and monitoring unit HPU-SM Smartpack Input ph without N ph or ph with N Voltage 400 V 400 V Max. current per phase 80 A 60 A Frequency 45 65 Hz 45 65 Hz Power factor λ > 0,94 cos φ, EN 6000-- Voltage selectable 4 V / 48 V / 60 V 48 V Max. current 500 A 600 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 8 x NH closed or -9 x NH00 closed or - 9 x NH- open or - 8 x NH00 open up to 46 x circuit breaker to 5 A Protection class IP0, EN 6059 IP0, EN 6059 Ambient temperature 0 to +45 C 40 to +70 C (with derating > 50 C) Without modules 454 kg 00 Fully equipped 889 kg 0 000 x 00 x 600 (without mains distribution cabinet) 000 x 600 x 600 SNMP-adapter Modem-signalling Temperature compensation 4 x 50 A / 48 V integrable 4 V with suitable LVD to +55 C possible if ph
Power Supply System Type Outdoorsystems customized SVS-G48/00-OUT Rectifier HR 00/ HR 400 Rectifier type E48/5 WBrug-GRM Max. rectifier number ( x HPU 500) Control and monitoring unit Input Voltage HPU-SM ph or ph with N x 0 V / 400 V Max. current per phase A Frequency 45 66 Hz Power factor cos φ, EN 6000-- Voltage selectable 4 V / 48 V / 60 V Max. current Psophometric noise 00 A < mv, ETSI 00 -/ITU-T Load feeders 0 x circuit breaker (expandable) Protection class IP54, EN 6059 Ambient temperature to +45 C Without modules Fully equipped 7 kg 58 kg 940 x 770 x 805 SNMP-adapter Modem-signalling Temperature compensation integrated battery compartment, max. levels per 00 Ah 4 V with suitable LVD to +55 C possible if ph
Control- and monitoring units Display / Monitoring elements Type of control-monitoring unit System rated voltages SVS-SM7 4 / 48 / 60 V HPU-SM/-SM/-SM 4 / 48 / 60 V Flatpack MCU 4 / 48 / 60 V Smartpack 4 / 48 / 60 V Buttons for data request and adjustments X X X X Display Display of measured values X X X X Display of error reports X X X X Communication interfaces Internal (controller) analog RS 485 analog CAN External (service laptop) RS RS RS USB Remote alarm (Modem, SNMP, TCP/IP) X X X X Event storage X X X X Characteristics X X X X Float charging / Boost charging Load voltage regulation X X X X Temperature compensation battery voltage X X X X DC-Voltage / Current displays X X X X Voltage monitors X X X X Battery/Load, Overvoltage/Undervoltage Battery discharge control X X X X Battery charging current limit X X X X Battery availability test (total battery) X X X X Battery symmetry monitoring X X X X System data X X X X Serial number / rated voltage / others LCD display / buttons Integrated into the module assembly X X X X Externally built X (HPU-SM) Expandable by means of external signalling X X modules Operating status signals LED X X X X Telecommunications signals pcs. expandable up to 0 6 expandable up to 6 expandable upon request Faults System malfunction (centralized signal) X X X X Rectifier fault X X X X Redundancy monitoring X X X X Battery/Load voltage fault X X X X Battery availability test fault X X X X Battery asymmetry X X X X Battery deep discharge X X X X Temperature fault X X X X Mains failure X X X X Voltage monitoring X X X X Fuse monitoring X X X X Others X X X X Signalling of site-based signals (freely available) not expandable expandable up to 4 5 not expandable 6 expandable upon request Internal clock / calendar X X X Potential free contacts Fault X X X X Mains failure X X X X Boost charging characteristic X (ventilator control) Others optionally expandable optionally expandable optionally expandable only if system is redundant RS optional optional The corresponding supplementary modules are available for measured value displays (e.g. current), as well as for data transfer by means of modem or SNMP adapter.
VOIGT & HAEFFNER GmbH Ferdinand-Porsche-Straße 45 6086 Frankfurt am Main Germany P.O. Box 6 06 5 6048 Frankfurt am Main Germany Phone: +49 (69) 40 0 0 Telefax: +49 (69) 40 0 89 www.vuh.de email: info@vuh.de