Power Supply System SVS 48/60 V-0/00A SVS 48/60 V-60/00 A HPS 00 Wall 4/48 V-00 A Type SVS-G48, 60/0-8GRS SVS-G48, 60/60-5GRS SVS-G48/00-GRW Rectifier RM 800 RM 800 HR 00 / HR 400 Rectifier type E60/5 WBrug-GRM E60/5 WBrug-GRM E48/5 WBrug-GRM Max. rectifier number 4 8 ( x HPU 500) Control and monitoring unit SVS-SM7 SVS-SM7 HPU-SM Input Voltage 0 V / 400 V 0 V / 400 V x 0 V / 08 V, x 0 V / 400 V Max. current per phase A 44 A 4 A Frequency 4565 Hz 4565 Hz 4565 Hz Power factor Voltage selectable 4 V / 48 V / 60 V 4 V / 48 V / 60 V 4 V / 48 V / 60 V Max. current 0 A 60 A 00 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 5 x circuit breaker x 6 A x 50 A 7 x NH00 x circuit breaker 4 x circuit breaker (expandable) Protection class Ambient temperature 0 to +45 C 0 to +45 C 0 to +60 C with derating > 50 C Output General data Weight Without modules 4 kg 70 kg 48 kg Fully equipped 66 kg 40 kg 70 kg 650 x 600 x 500 000 x 600 x 500 670 x 600 x 400 SNMP-adapter Modem-signalling Deep voltage discharge protection Temperature compensation Battery Cabinets (H x W x D in mm) 650 x 600 x 500 000 x 600 x 500 400 x 600 x 500 Dimensions H x W x D (in mm) Options 4 V with suitable LVD to +55 C possible if ph
Power Supply System HPS 400 Floor 4/48 V-400 A HPS 760 with BVS 800 SVS 48/60 V-50 A Type SVS-G48/400-GRF G48,60/760-GRS0 / BV48,60/800BVS0 according implementation Rectifier HR 00 / HR 400 HR 00 / HR 400 RM 8000 Rectifier type E48/5 WBrug-GRM E48/5 WBrug-GRM / E60/ WBrug-GRM0 D60/50 WBrug-GRM Max. rectifier number 6 (4x HPU 500) (8 x HPU 500) 5 Control and monitoring unit HPU-SM HPU-SM HPU-SM Input ph without N Voltage x 0 V / 08 V, x 0 V / 400 V x 0 V / 08 V, x 0 V / 400 V 400 V Max. current per phase A 88 A 40 A Frequency 4566 Hz 4566 Hz 4565 Hz Power factor λ > 0,94 Voltage selectable 4 V / 48 V / 60 V 4 V / 48 V (HR00) 48 V / 60 V (HR400) 4 V / 48 V / 60 V Max. current 400 A 800 A 50 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 4 x circuit breaker (expandable) 8 x NH00 TPS (400A) closed or -7 x NH00 closed or -8 x NH- open or -9 x NH00 open 0 x NH closed or - x NH00 closed or - x NH- open or - x NH00 open Protection class Ambient temperature 0 bis +60 C with derating > 50 C 0 to +60 C with derating > 50 C 0 to +45 C Without modules 76 kg 95 kg (HPS760) kg (BVS800) 0 kg Fully equipped 8 kg 0 kg (HPS760) 80 kg BVS800) 59 kg 800 x 600 x 600 800 x 600 x 600 (HPS760) 800 x 600 x 600 (BVS800) 000 x 400 x 600 SNMP-adapter Modem-signalling Deep voltage discharge protection Temperature compensation Battery Cabinets (H x W x D in mm) integrated battery compartment, max. levels per 00 Ah Output General data Weight Dimensions H x W x D (in mm) Options 4 V with suitable LVD to +55 C possible if ph
Power Supply System SVS 48/60 V-500 A FP Systems 600A Outdoorsystems customized Type according implementation FP Sytem 400Vac 48V 600A SVS-G48/00-OUT Rectifier RM 8000 FP 48V 000W HR 00/ HR 400 Rectifier type D60/50 WBrug-GRM E48/4 WBrug-GRM E48/5 WBrug-GRM Max. rectifier number 0 6 (expandable ) ( x HPU 500) Control and monitoring unit HPU-SM Smartpack HPU-SM Input ph without N Voltage 400 V 400 V x 0 V / 400 V Max. current per phase 80 A 60 A A Frequency 4565 Hz 4565 Hz 4566 Hz Power factor λ > 0,94 Voltage selectable 4 V / 48 V / 60 V 48 V 4 V / 48 V / 60 V Max. current 500 A 600 A 00 A Psophometric noise < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T < mv, ETSI 00 -/ITU-T Load feeders 8 x NH closed or -9 x NH00 closed or - 9 x NH- open or - 8 x NH00 open up to 46 x circuit breaker to 5 A 0 x circuit breaker (expandable) Protection class IP54, EN 6059 Ambient temperature 0 to +45 C 40 to +70 C (with derating > 50 C) to +45 C Output General data Weight Without modules 454 kg 00 7 kg Fully equipped 889 kg 0 58 kg 000 x 00 x 600 (without mains distribution cabinet) 000 x 600 x 600 940 x 770 x 805 SNMP-adapter Modem-signalling Deep voltage discharge protection Temperature compensation Battery Cabinets (H x W x D in mm) 4 x 50 A / 48 V integrable integrated battery compartment, max. levels per 00 Ah Dimensions H x W x D (in mm) Options 4 V with suitable LVD to +55 C possible if ph
Control- and monitoring units Display / Monitoring elements Type of control-monitoring unit System rated voltages SVS-SM7 4 / 48 / 60 V HPU-SM/-SM/-SM 4 / 48 / 60 V Flatpack MCU 4 / 48 / 60 V Smartpack 4 / 48 / 60 V Buttons for data request and adjustments Display Display of measured values Display of error reports Communication interfaces Internal (controller) analog RS 485 analog CAN External (service laptop) RS RS RS USB Remote alarm (Modem, SNMP, TCP/IP) Event storage Characteristics Float charging / Boost charging Load voltage regulation Temperature compensation battery voltage DC-Voltage / Current displays Voltage monitors Battery/Load, Overvoltage/Undervoltage Battery discharge protection control Battery charging current limit Battery availability test (total battery) Battery symmetry monitoring System data Serial number / rated voltage / others LCD display / buttons Integrated into the module assembly Externally built (HPU-SM) Expandable by means of external signalling modules Operating status signals LED Telecommunications signals pcs. expandable up to 0 6 expandable up to 6 expandable up Faults System malfunction (centralized signal) Rectifier fault Redundancy monitoring Battery/Load voltage fault Battery availability test fault Battery asymmetry Battery deep discharge Temperature fault Mains failure Voltage monitoring Fuse monitoring Signalling of site-based signals (freely available) Others not expandable expandable up to 4 5 not expandable 6 expandable up Internal clock / calendar Potential free contacts Fault Mains failure Boost charging characteristic (ventilator control) Others optionally expandable optionally expandable optionally expandable only if system is redundant The corresponding supplementary modules are available for measured value displays RS optional (e.g. current), as well as for data transfer by means of modem or SNMP adapter. optional
ELTEK VALERE Deutschland GmbH Ferdinand-Porsche-Straße 45 6086 Frankfurt am Main Germany P.O. Box 6 06 5 6048 Frankfurt am Main Germany Phone: +49 (69) 40 0 0 Telefax: +49 (69) 40 0 89 www.eltekvalere.de email: info@eltekvalere.de