MONOVAR is the energy dissipating valve.

Similar documents
BERMAD Waterworks. 800 Series. Technical Specifications Metric

Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Components of Hydronic Systems

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

FIXED CONE VALVE. The flow is guided by the inner vanes, in order to decrease the vortex and the vibration;

The Discussion of this exercise covers the following points:

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Yarway Hy-Drop Throttling valve

ANTI-CAVITATION SOLUTIONS

Sleeve Valves Energy Dissipaters

Distributed By: M&M Control Service, Inc

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

PLUNGER VALVES F500 / F560 / F550

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

We proudly deliver a unique and

Nero Needle Valves. Nero Needle Valves

PNEUMATICALLY ACTUATED 2-WAY

VAD Variable Area Desuperheaters

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

ERHARD is a company of. Data sheet ERHARD needle valves

Pressure Reducing Valve Type 2114/2415

VAG RIKO Plunger Valve

Rotary Valve Maxflo + 60 and 80 Opening type NT

Valve Selection. 1. Function and service considerations

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

485 - NC NO/DA DN

2-Port Seat Valves with Flange, PN 25

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Gauges, Sight Glasses and Vacuum Breakers

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

Temperature Regulators

Yarway Narvik Model 37 and 47 Cryogenic injector

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

YARWAY THROTTLING VALVES HY-DROP MODEL 5817/ 5827

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6


W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

MAMMOUTH Type Series Booklet

From PN10 to PN100 (from ANSI125 to ANSI600)

VB VALVES & AUTOMATION

A ZURN Company Rotovalve Cone Valve 20 Questions

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

walton TEMPERATURE CONTROL SYSTEMS Pneumatically Operated (Rotary)

IFOA Integral Flow Orifice Assembly

Experiment (4): Flow measurement

VRX Plunger. Advanced Control Valve

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Air Operated Valve Control Valve

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

Please note this is a condensed catalog. For a complete version, contact Velan directly.

Pumping Station. Marisa Handajani

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

Type 310A-32A Pressure Reducing Regulator

Applied Fluid Mechanics

Ballcentric Plug Valve

2-port seat valves PN25 with flanged connection

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

DJ Series Butterfly Valves

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

BERMAD Irrigation. Technical Specifications. WW-700 & 800 Series Metric. 800 Metric

Baumann Mikroseal Control Valve

AUTOMATIC CONTROL VALVES. TIS asia

Pressure reducing valves

V1C Series. Pneumatic Control Valves V1C Series Cage-Guided Control Valves. Cage-Guided Control Valve. Features

KOSO HAMMEL DAHL VeCTor Trim

AUTOMATIC CONTROL VALVES BY RAPHAEL

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

STYLE J COMBINATION PRESSURE AND TEMPERATURE REGULATOR

Silencers. Transmission and Insertion Loss

2- and 3-port valves with flanged connections, PN 16

PBV s Engineering Excellence At Work

Pump Control Ball Valve for Energy Savings

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

2-way and 3-way globe valves

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Grey cast iron SG iron Cast steel/ Forged steel High temperature steel Stainless steel Fig. 631 Page 2

627 Series Pressure Reducing Regulators

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

V5000. Globe Valves Series for Terminal Units. Product Bulletin

Valve Series V2001 Three-way Valve Type 3323

78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

RUBBER SLEEVE KNIFE GATE VALVE

Transcription:

MONOVAR is the energy dissipating valve. Features Extremely simple design (patented) Excellent cavitation characteristics Very accurate flow or pressure control Manual or automatic control Suitable for flow measurement Small sizes are available Minimum flow disturbance The flow is divided equally over a larger number of jets. This ensures an accurate and stable performance These unique features, together with the wide range of construction materials make MONOVAR valves an automatic choice in all severe industrial and water-supply situations requiring fluid flow control or of some associated characteristic, e.g. pressure, temperature and level The design suppresses vibration, cavitation, pressure fluctuations and excess noise Suitable for high velocity applications Suitable for high pressure drop applications Valve shown: MONOVAR DN2000 (80 ) Applications Application of MONOVAR : - Water supply systems (reliability, pressure, cavitation), - Industrial flow, cooling and mixing systems (cavitation, sensitivity, pressure, reliability), - Head works of water treatment plant (reduced civil works, cavitation, reliability), - Laboratory test-rigs (sensitivity, absence of disturbances), - Turbine bypass (dams), - End of line, free discharge, - Replace variable speed pumps with constant flow or constant pressure pumps in combination with MONOVAR, - Seawater applications on request. Technical features Size range : DN100 - DN2000 (4-80 ) Pressure range : 50 bar (725 psi) Temperature range : -50 to +200 C (-60 F to +390 F) Flange accommodation : EN 1092-1 PN10/16/20/25 ANSI B16.5 class 150 MSS SP 44 class 150 AWWA C207 Others on request Example shown is a large dam in California, USA. Sapag reserves the right to change the contents without notice SAHFR-0017-EN-0406

Operating principle The simplicity of the MONOVAR design is explained in Figure 1. Components are simply two circular perforated plates, and an annular body (1) mounted between pipe flanges. Plate (2) is fixed. Plate (3) on the upstream side is free to slide up and down. In the fully open position the orifices in the plates are in line. The fully closed position is obtained by displacing the mobile plate (3) by one full orifice diameter. Under specified flow conditions, the position is intermediate, with the orifices in the fixed plate partly blocked off by those of the mobile plate. The valve can be operated both manually or by using pneumatic, hydraulic or preferably electric modulating actuators. Flow Pipe flange Pipe Advantages The energy released by a fluid when it flows through a valve often causes disturbance in the flow. 3 1 2 Figure 1 1 = Annular body 2 = Downstream, fixed plate 3 = Upstream, mobile plate Examples are: flow and pressure fluctuations liable cause vibration in the pipework, cavitation bubbles (i.e. fluid vapor bubbles), and noise. Noise is caused by sudden implosion of cavitation bubbles. In MONOVAR valves, energy dissipation is controlled by multiple distributed jets which divide the flow. This means that disturbing effects are considerably reduced, as described below: - Flow fluctuations are reduced by the jet design and the quick flow stabilization. Consequently, devices such as flow meters may be placed much closer to the control valve than usual, so the system can be constructed more compact. - MONOVAR control valves have better cavitation indexes which are more favorable than those of conventional valves. Due to its design MONOVAR copes better with cavitation than traditional control valves. - Fully developed cavitation does not damage MONOVAR valves since the implosions occur in the fluid and not in the valve its vital parts. This unique design outperforms the design of conventional valves where cavitation is frequently observed on the obturator and seat. Vapor bubbles are not formed when MONOVAR valves are properly selected. A final point for operational reliability: MONOVAR valves do not have a natural tendency to open or close while controlling flow or pressure. Sapag reserves the right to change the contents without notice page 2

Hydraulic characteristics This section gives a brief overview of the hydraulic design data and selection criteria for MONOVAR control valves. The data come from measurements made on the Sapag test rigs, from experience gained on Sapag turbine test installations, and from feedback from MONOVAR users in the industry and in the water resources field. Cavitation The flow-path contractions, sudden expansions and changes of direction encountered by a fluid as it passes through a valve tend to create -locally- a reduction of pressure. If the local pressure drops below the vapor pressure of the liquid, then the liquid boils. Vapor bubbles and their implosions appear in the liquid. This phenomenon is called cavitation. The tendency of a valve to cavitate is usually characterized by a cavitation number defined as: P2-Pv P 1 : absolute upstream pressure measured in practice one pipe diameter above the valve, P 2 : absolute pressure measured 10 pipe diameters below the valve and corrected for friction losses between points 1 and 2, P V : vapor pressure of the liquid at the operating temperature. These pressure values are generally expressed as meters head of liquid. Some valve manufacturers utilize a cavitation number defined as: K = with the same notations. Simple algebra shows that the two numbers are related by K = P1-Pv 1 1 + σ and 1 - K K σ MONOVAR index cavitation 1,4 Area 1 1,2 1 Area 2 0,8 0,6 0,4 0,2 0 0 20 40 60 80 % opening Area 3 Forbidden area For a given valve opening various values of σ are established by the manufacturer corresponding to various degrees of cavitation. Also defined for a given valve is how the σ values vary with opening. These values may be plotted in the form of so-called required sigma curves which indicate the degree of cavitation risk which will be encountered by users of the manufacturer s valve. Specific flow Specific flow is defined as the flow passing through a one meter diameter MONOVAR, which causes a head loss equal to one meter head of water. Specific flow q 11 may be written in terms of head loss as: Typical flow characteristics Q Flow % D 2 H 100 q 11 : specific flow in m 3 /s at a given valve opening, Q : the total flow passing through the valve in m 3 /s, 80 H : the head loss in water column meters liquid at the same valve opening, D : is the nominal MONOVAR diameter in meters. 60 The graph shows how q 11 varies with valve opening at constant headloss. Note that q 11 may be expressed in terms of the head loss coefficient for example in the fully open 40 position, the specific q 11 of a MONOVAR valve with maximum perforated area installed in a pipe whose diameter is equal to the nominal diameter of the valve is 1,3 m 3 /s. 20 The specific flow value drops to 0,95 m 3 /s for an end-mounted valve. π 2 g 8k 10 10 20 40 60 80 100 % valve opening Head loss The pressure drop caused by flow through MONOVAR valves is written as: Headloss coefficient / % valve opening H = k V2 2g k 1000 H : the pressure drop in meters water column at a given valve opening, k : the (dimensionless) head loss coefficient at the same valve opening, V : the velocity of the liquid in meters per second computed on the basis of the nominal flowsection of the valve, g : gravitational acceleration in meters per square second. 100 The graph shows an example curve of k values for maximum perforated area of the MONOVAR plates. 10 10 20 40 60 80 100 % valve opening Sapag reserves the right to change the contents without notice page 3

Hydraulic characteristics Graphic method of determining available sigma The available cavitation figures may be calculated quite simply by graphic means. The example calculation shown in the Figure below is based on flow between tanks at different levels. The figure depicts the connecting pipe and included control valve and, to the right, a head versus flow chart. Pressures are expressed here as heads of flowing liquid because this is the usual procedure. However, variables H1, H2, HV have the same basic meanings as P1, P2, PV cited above, e.g., Hv is the vapor pressure of the flowing liquid expressed in meters head of that liquid. Vertical a b c d conveniently depicts the head loss components at the maximum value of discharge Q. The head losses above and below the valve are ab and cd respectively. The intermediate distance bc, i.e. (H1 - H2) represents the head loss which may be throttled out by the valve. The (quadratic) curves leading down to b and up to c show how head is lost by friction effects along the two lengths of pipe. Ha, the head at point a, corresponds to the pressure at the surface of the upper tank, I.e. atmospheric. Having drawn out the essentials of the figure thus far, it only remains to add a further horizontal line labeled e. This should be drawn at a distance equal to (Ha - HV) below the zero head axis. The numerator (P2 - PV) of the sigma expression is represented by the length ce, which is evidently equivalent to H2 + Ha - HV, the denominator being bc. The desired sigma cavitation number is therefore ce/bc. Head H in meters versus flow rate Q Upstream tank Headloss a H 1 b H 2 c MONOVAR valve 1 2 0 (H a H v ) Downstream tank d e Q Flow Operating limits Temperature MONOVAR valves made from the standard materials should not be operated outside the temperature range 0 to 80 C. Seal effectiveness may be maintained up to 200 C by using special seal material. Elastomer and plastomer seals cater to low temperatures down to -50 C. The temperature limits above are only approximate and depend on fluid and operating pressure. Pressure PN64 : DN100 PN40 : DN150 PN25 : DN200 to DN600 PN16 : DN700 to DN800 PN10 : DN900 to DN2000 Tightness Valve is not bubble tight as it is recommended to install the MONOVAR between two isolation valves. The MONOVAR is unidirectional. In case of backflow, please contact factory. Sapag reserves the right to change the contents without notice page 4

Characteristics MONOVAR flow and cavitation characteristics are shown in Figure 2 in terms of specific flow q 11 in m 3 /s. Q D 2 H Figure 2 Control valve MONOVAR Monovar flow and cavitation characteristics Possible q 11 MONOVAR DN 450 q 11 MONOVAR DN 400 q 11 MONOVAR end of line valve Impossible Opening % Q : m 3 /s D : m H : headloss in m Area 3 Forbidden area P2-Pv Area 1 K = P1-Pv Area 2 Area 1: Excellent operation Area 2: Acceptable operation Area 3: Possible operation Area 4: Forbidden area Please contact factory for applications in area 3 and 4. Diameter choice 1. Input data liquid Flow rate adjustable between Q and Q Range of absolute upstream pressure P 1 and P 1 Range of absolute downstream pressure P 2 and P 2 Available MONOVAR throttling range H and H Vapor pressure of liquid at operating temperature P V Nominal diameter of pipe D Example (water) Q = 0.150 m 3 /s Q = 0.250 m 3 /s P 1 = 50 mwc P 1 = 48 mwc P 2 = 25 mwc P 2 = 28 mwc H = 25 mwc H = 20 mwc P V =0.2 mwc D =0.3 m 2. First computation stage Example (water) calculate D 2 Q H and q 11 = D 2 Q H 0,15 0,3 2 25 = 0,33 0,25 q 11 = 0,3 2 20 = 0,62 if q 11 < 1.3, the MONOVAR diameter will be less than or equal to D if q 11 > 1.3 the MONOVAR diameter will be greater than D, and the new valve should be chosen so that q 11 1.3 0.62 < 1.3: the MONOVAR will therefore have a diameter 0.3 Note: Pipe fittings such as bends, cones or any other mechanical equipment will alter the MONOVAR s specifications. In that case, please contact factory. 3. Second computation stage Example (water) P2-Pv σ = P 2-Pv P1-P 2 25-0,2 50-25 = 0,99 28-0,2 σ = 48-28 = 1,39 If points (q 11, σ) are situated in cavitation area 1 (excellent) in Figure 2, then there is no risk of cavitation and the MONOVAR diameter initially assumed may be selected - or even reduced. If points (q 11, σ) are situated in areas 2 or 3 (acceptable or possible), the effective cavitation risk will depend on operating life and it may be necessary to choose a larger MONOVAR. As both points lie in area 1, a 0.3 m diameter MONOVAR may be chosen. If D were reduced to 0.25 m, then 0.48 q 11 = 0.89 and the valve would be subject to cavitation in certain cases. Sapag reserves the right to change the contents without notice page 5

Valve dimensions Manual actuators Electric actuators Valve dimensions (mm) DN Weights (mm) (inch) C ød G H K L M P R S manual electric 100 4" 60 162 313 446 404 309 64 296 125 125 11 30 150 6" 80 220 348 516 428 309 110 558 148 374 73 67 200 8" 80 290 348 541 428 309 110 583 148 374 86 79 250 10" 84 350 348 576 428 309 110 618 148 374 105 80 300 12" 95 400 348 636 428 309 110 678 148 374 127 115 350 14" 110 438 589 1266 428 309 178 1210 178 530 258 286 400 16" 110 516 589 1271 428 309 178 1215 178 530 290 318 450 18" 140 560 589 1276 428 309 178 1220 178 530 320 350 500 20" 150 594 589 1296 428 309 178 1240 178 530 351 390 600 24" 160 696 589 1366 428 309 178 1310 178 530 432 470 700 28" 160 806 589 1396 428 309 178 1340 178 530 494 510 800 32" 160 914 589 1456 428 309 178 1400 178 530 614 610 900 36" 160 1017 589 1519 428 309 178 1460 178 530 662 690 1000 40" 160 1124 589 1596 428 309 178 1540 178 530 778 806 1200 48" 160 1342 589 1666 283 160 178 1610 178 530 1015 1043 1400 56" 160 1580 589 1816 283 160 178 1760 178 530 1336 1364 1500 60" 250 1660 589 1866 283 160 178 - - - - 2100 1600 64" 330 2032 331 2510 994 254 384 - - - - 5500 2000 80" 450 2345 352 3767 368 437 913 - - - - 8500 Materials of construction Standard materials are as follows: - Body: EN GJS 500-7 nodular cast iron - Fixed plate: EN GJS 700-2 nodular cast iron or 13% Cr stainless steel (X20 C13) - Moving plate: EN GJS 500-7 nodular cast iron or 13% Cr stainless steel (X20 C13) - Support: EN GJS 500-7 nodular cast iron - Stem: 13% Cr stainless steel - Flange and stem seals: 70 Shore-hardness Perbunan Other construction materials are available on request to suit particular operating conditions. Notes Dimensions in mm, weights in kg Dimensions and weights are given as a guide Sapag reserves the right to change the contents without notice page 6

Valve actuators MONOVAR control valves may be controlled manually (handwheel with micrometer position indicator) or by electric, pneumatic or hydraulic powered actuators. Information on the large range of actuator possibilities is available on request. Recommended installation standard position Flow Free from any mechanical equipment 5 x DN Straight lengths of pipe Free from any mechanical equipment 3x DN General installation instructions - Allow the MONOVAR to be removed at a later stage (observe clearances, use sliding joints and unions, etc.). - Install the pipeline, or use the appropriate fittings, so that the MONOVAR does not have to withstand any abnormal loads, resulting from mechanical pipe stresses or from thermal expansions. - Check that the pipe sections are in line, that the flanges are parallel, that any sliding flanges are working correctly and that the holes in mating flanges coincide. - Depending on the kind of water carried, provide a screen, a filter or sludge trap upstream of the valve in order to prevent it from jamming or suffering any mechanical damage. - Check that the valve is installed correctly with respect to the direction of fluid flow. An arrow on the body of the MONOVAR shows the correct direction; this direction must be followed, in order to prevent failure. - Before installing the MONOVAR, clean it with a jet of compressed air. Ensure that the pipes are perfectly clean and especially that there is no material inside them likely to cause serious damage (lumps of rust, welding pearls, slag, etc.). - Bear in mind that proper installation of the MONOVAR is a precondition for satisfactory working of the valve. - MONOVAR valves may be mounted between pipe flanges with the help of tie-rods, which ensure correct alignment. They may also be mounted at the end of a pipe. To facilitate mounting and disassembly, the use of sliding flanges or sleeves are recommended. - The valves may be installed in both vertical and horizontal pipes. In vertical pipes the flow should preferably be downwards. Valves mounted horizontally should be placed with the actuator upwards to make proper use of the drain orifice, which will then be situated on the lower side. Sapag reserves the right to change the contents without notice page 7

Control details A controller is designed to control a valve that will regulate the flow or the pressure in an installation. The controller is a PID type (Proportional, Integral, Derivative). In addition to regulation, the controller can accept input data, relevant to the process, from various sources (pressure sensors, etc.). The controller can analyze them (alarm etc.) The controller can be installed on its own (self managing) or be part of a centralized system. Example of regulation - Upstream pressure - Upstream level - Downstream pressure - Downstream level - Flow (with head loss measurement) - Flow (with flow meter) - Upstream pressure and flow totals - Downstream pressure and flow totals - Upstream level and flow totals - Downstream level and flow totals Operating diagram: Power supply Controller Power supply 220V AC Box positioner and local control Electric actuator Control output analog output (4-20mA) Digital output travel and torque limit switches Valve position analog output (4-20mA) Controller Digital output: alarms Analog output (4-20mA): MONOVAR flow External value input (4-20mA): Pressure value analog input (4-20mA) MONOVAR valve (7) Mounting plate or box Value transmitter input analog input (4-20mA) (6) Terminal blocks Upstream Flow Size Downstream Downstream pressure transmitter Upstream pressure transmitter Differential pressure transmitter * * For proper pressure transmitter installation details, please contact factory. Sapag reserves the right to change the contents without notice page 8