TAE pole Contactors

Similar documents
AE 9... AE 40 Contactors NE... Contactor Relays

ASL09..S 3-pole Contactors - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

AF40... AF96 3-pole contactors Technical data

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Description. Positive safety relays

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Short form catalogue. Motor protection & control

Accessories for Contactors and Contactor Relays

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Star Series Motor protection & control

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

B Mini Contactor V Hz

Contactors type AF1350-AF1650

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Quality Products, Prompt Service, Trustful Relationships.

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Motor Starting Solutions Open Type Version, in Kit Form

Auxiliary contact blocks - with spring terminals Accessories

BC Mini Contactor VDC

Industrial Contactors CTX 3 3P 185A - 800A

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Mini contactors B6, BC6 with 3 pole

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Thermal overload relays Type TA Class 10

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Micro Contactor MA Series

Application Mini Contactors for Motors and Resistive Loads

Meta Solution. Contactors and Overload relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Electronic overload relays EF205 and EF370

4 - Miniature controls

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

3 - Protection components Motor circuit-breakers

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Electronic overload relay EF65, EF96 and EF146

Overview. Contents. Overview

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Starting Combinations

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

MS General Information Extended Product Type: MS

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Technical Information

Application Mini Contactors for Motors and Resistive Loads

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

3RT14 Contactors with 3 Main Contacts

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

US catalog. R contactors Control of AC and DC power circuits up to 5000 A

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Mini Contactors CI 4-

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Special Purpose Fuses

Manual motor starter magnetic only MO325

Thermal overload relay TF65 and TF96

FOOT SWITCHES

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

CI-TI Contactors and motor starters Types CI 61 - CI 98

Switches Unlimited Phone: * Fax:

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Page 2-4 Page 2-8. Page Page 2-13

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Manual motor starter MS132

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Protection Equipment

Manual motor starter MS132

Technical data for manual motor starters Type MS325

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Solid State Relays, 3-phase

AF series contactors (9 2650)

US Catalog. Motor protection and control AF Range contactors & overload relays

Transcription:

TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges in accordance with the requirements of railway applications. They are also suitable for control from a battery supply. The complimentary technical information not included in these pages can be found in the Main Technical Catalogue for Contactors 1SBC0122C0201. TAE 12-30-00 Coil voltages and codes: TAE Voltage - U c Code V d.c. 17... 32 5 1 25... 5 5 2 36... 65 5 2... 78 5 8 50... 5 5 77... 13 6 2... 150 6 6 152... 26 6 8 Other voltages: please consult us. Ordering Details: TAE... Rated operational Auxiliary contacts Type Order code Weight current fitted kg AC-3 AC-1 00 V θ < 0 C state coil voltage state coil voltage code Pack ing A A (see opposite table) (see opposite table) 1 piece 9 25 TAE 9-30-00 1SBL 1 61 R 00 0.30 12 27 TAE 12-30-00 1SBL 16 61 R 00 0.30 16 30 TAE 16-30-00 1SBL 18 61 R 00 0.30 26 5 TAE 26-30-00 1SBL 2 61 R 00 0.600! Voltage tolerances (-15 % and + %) included in the U c min. and U c max. values for the TAE... contactors. Replacement Coils For contactor Type Order code Weight kg state coil voltage state coil voltage code Pack ing (see opposite table) (see opposite table) 1 piece TAE9...TAE16 ZAE16 1SBN 15 1 R 06 0.093 TAE26 ZAE0 1SBN 15 2 R 06 0.18 1/1 Low Voltage Products 1SBC01D0201

TAE9...26 Contactors Technical Data General Technical Data Rated insulation voltage U i according to IEC 6097--1 V 00 according to UL/CSA V 600 Rated impulse withstand voltage U imp. kv 8 Standards Devices comply with international standards IEC 6097-1 / 6097--1 and European standards EN 6097-1 / 6097--1 Certifications - Approvals see Technical Catalogue 1SBC0122C0201 Air temperature close to contactor "Conditions for use" page 1/, for control voltage limits and authorized mounting positions fitted with thermal O/L relay C -25 to +55 without thermal O/L relay C -0 to +55 for storage C -60 to +80 Climatic withstand acc. to IEC 600-2-30 and 600-2-11 - UTE C 63-0 specification II Operating altitude m < 3000 Shock withstand acc. IEC 600-2-27 and EN 600-2-27 Mounting position 1 ( page 1/ ) A A B1 C1 C2 B2 E0202D1 1/2 sinusoidal shock for 11 ms: no change in contact position Shock direction Making position Breaking position A 20 g 20 g B1 g 5 g B2 15 g 15 g C1 20 g 20 g C2 20 g 20 g Magnet System Characteristics for TAE... Contactors Rated control circuit voltage U c V d.c. 17... 26 Coil operating limits θ < 55 C Uc min.... U c max. Drop-out voltage in % of U c max.... 30 % Coil consumption values for U c min.... U c max. pull-in value W 65... holding value W 1.0... 3.5 Coil time constant open L/R ms 2 3 closed L/R ms 9 16 Operating time between coil energization and: N.O. contact closing ms... 16 13...21 N.C. contact opening ms 8... 12 11...16 between coil de-energization and N.O. contact opening ms 5... 1 (1) 6... 12 (1) N.C. contact closing ms 11... 17 (1) 8...16(1) (1) The use of surge suppressors increases the opening time on a scale of 1.1 to 1.5 for a varistor suppressor and on a scale of to 8 for a diode suppressor. 1/2 Low Voltage Products 1SBC01D0201

TAE9...26 Contactors Technical Data Main Pole - Utilization Characteristics Rated operational voltage U e max. V 6 Rated frequency limits Hz 25... 00 Conventional free-air thermal current I th acc. to IEC 6097--1, open contactors θ 0 C A 26 28 30 5 with conductor cross-sectional area mm 2 6 Rated operational current I e / AC-1 for air temperature close to contactor θ 0 C A 25 27 30 5 U e max. 6 V θ 55 C A 22 25 27 0 { θ 70 C (1) A with conductor cross-sectional area mm 2 2.5 6 Utilization categorie AC-3 for air temperature close to contactor < 55 C Rated operational current I e AC-3 220-230-20 V A 9 12 17 26 3-phase motors 380-00 V A 9 12 17 26 15 V A 9 12 17 26 M 3 M 3 0 V A 9 12 16 26 500 V A 9 12 1 22 6 V A 7 9 17 00 V A Rated operational power AC-3 220-230-20 V kw 2.2 3 6.5 1500 r.p.m. 50 Hz 1800 r.p.m. 60 Hz 380-00 V kw 7.5 11 3-phase motors 15 V kw 9 11 0 V kw 9 15 500 V kw 7.5 9 15 6 V kw 7.5 9 15 00 V kw Rated making capacity AC-3 according to IEC 6097--1 x I e AC-3 Rated breaking capacity AC-3 according to IEC 6097--1 8 x I e AC-3 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded U e < 500 V a.c. - gg type fuse A 25 32 32 50 Rated short-time withstand current I cw at 0 C ambient temp., in free air, from a cold state 1 s A 250 280 300 00 s A 0 120 2 30 s A 60 70 80 1 1 min A 50 55 60 15 min A 26 28 30 5 Maximum breaking capacity cos ϕ = 0.5 (cos ϕ = 0.35 for I e > 0 A) at 0 V A 250 250 250 20 at 6 V A 0 0 0 170 Heat dissipation per pole I e / AC-1 W 0.8 1 1.2 1.8 I e / AC-3 W 0.1 0.2 0.35 0.6 Max. electrical switching frequency for AC-1 cycles/h 600 for AC-3 cycles/h 600 for AC-2, AC- cycles/h 300 Electrical durability See A Contactor curves in Technical Catalogue 1SBC0122C0201 Mechanical durability millions of operating cycles 5 max. mechanical switching frequency cycles/h 3600 (1) Unauthorized for TAE... contactors. 1/3 Low Voltage Products 1SBC01D0201

TAE9...26 Contactors d.c. Operated with Double-Winding Coil Mounting Characteristics Mounting positions Mounting distances Shown below Fixing on DIN rail 35 x 7.5 mm according to IEC 715 and EN 50022 / EN 50023 35 x 15 mm by screws (not supplied) The contactors can be assembled side by side 2 x M Conditions for Use The contactor utilisation conditions relating to the Mounting position, Ambient temperature and Control voltage operating limits are summarized in the table below. Contactors Mounting position Ambient temperature Control voltage TAE 9... TAE 26 1,1 + 30, 2, 3,, 5 < 55 C U c min.... U c max.. Mounting Positions (see the above table for authorized positions) Position 2. Position -30 +30 Position 3 Position 5 Position 1 Position 1 ± 30 TAE9 to TAE26 accessory compatibility Contactor configuration Front-mounted accessories (1) Side-mounted accessories Main poles Available auxiliary contacts Contactor Auxiliary contact Auxiliary contact Pneumatic timer Auxiliary contact Interlock unit types 1-pole CA 5-.. -pole CA 5-.. (2) TP.. A 2-pole CAL 5-11 VM 5-.. or VE 5-.. TAE 9... TAE 26 3 0 0 0 1 to x CA 5-.. or 1 x CA 5-.. (-pole) or 1 x TP.. A + 1 to 2 x CAL 5-11 or 1 x VM 5-1 or VE 5-1 + 1 x CAL 5-11 1/ Low Voltage Products 1SBC01D0201

TAE9...26 Contactors Technical Data Connecting Characteristics Main terminals with cable clamp Connecting capacity (min.... max.) Main conductors (poles) } Rigid:solid ( mm 2 ) 1 x mm 2 1... 1.5... 6 stranded ( 6 mm 2 ) 2 x mm 2 1... 1.5... 6 Rigid with connector single for Cu cable mm 2 single for Al/Cu cable mm 2 double for Al/Cu cable mm 2 Flexible with cable end 1 x mm 2 0.75... 2.5 1.00... 2 x mm 2 0.75... 2.5 1.00... Bars or lugs L mm 8 l L l mm > 3.7.2 Auxiliary conductors (coil terminals) Rigid solid 1 x mm 2 1... 2 x mm 2 1... Flexible with cable end 1 x mm 2 0.75... 2.5 2 x mm 2 0.75... 2.5 Lugs L mm 8 l L l mm > 3.7 L < 8 and l > 3.7 for coil terminal - L < and l >.2 for built-in auxiliary terminals. Degree of protection acc. to IEC 6097-1 / Protection against direct contact acc. to VDE 06 - Part. 0 EN 6097-1 and IEC 60529 / EN 60529 Main terminals IP 20 Coil terminals IP 20 Screw terminals Main terminals Coil terminals (delivered in open position, screws of unused terminals must be tightened) (+,-) pozidriv 2 screws M3.5 M M3.5 (+,-) pozidriv 2 screws with cable clamp Tightening torque Main pole terminals recommended Nm / lb.in 1.00 / 9 1.7 / 15 max. Nm 1.20 2.20 Coil terminals recommended Nm / lb.in 1.00 / 9 max. Nm 1.20 Terminal marking and positioning See Section 8 of Technical Catalogue 1SBC0122C0201. Same as all AE range. 1/5 Low Voltage Products 1SBC01D0201

TAE 9, TAE 12 and TAE 16 3-pole Contactors Dimensions (in mm) 7 0.5 7 7 E1305D E1307D 7 7 12 E1309D E1311D 7 E1313D 7 E1315D ø.5 (M) 35 50 60 7 E1306D2 E1308D2 TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16 + CA 5 front-mounted 1-pole auxiliary contact block 7 7 7 E13D2 E1312D2 TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted -pole auxiliary contact block 127 15 7 E131D2 3 E1316D2 TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16 + TP pneumatic timer + WB 75-A on-position latch.5.5 E01D TAE 9, TAE 12, TAE 16 Detailed dimension drawings available in DXF and PDF formats. 1/6 Low Voltage Products 1SBC01D0201

TAE 9, TAE 12 and TAE 16 3-pole Contactors Dimensions (in mm) 7 ø.5 (M) 7 3 E1317D 7 50 60.5 35 59.5 E01D1 ø.5 (M) 50 60 E1318D2 TAE 9, TAE 12, TAE 16 + VE 5-1 electrical and mechanical interlock unit 7.5 3 E1319D E1320D2.5 35 59.5 E01D1 TAE 9, TAE 12, TAE 16 + VM 5-1 mechanical interlock unit 7 ø.5 (M) 35 7 50 60 133 13.5.5 E01D E1321D 1 95 1* 6 E1322D TAE 9, TAE 12, TAE 16 + TA 25 DU thermal O/L relay * For TA 25 DU 32 only Detailed dimension drawings available in DXF and PDF formats. 9 1/7 Low Voltage Products 1SBC01D0201

TAE 26 3-pole Contactors Dimensions (in mm) 9 6.3 9 119.8 7 5 E1323D E132D 5 E1325D E1326D TAE 26 TAE 26 + CA 5 front-mounted 1-pole auxiliary contact block 9 6.3 126.3 9 7 7 12 5 E1327D E1328D 5 E1329D E1330D TAE 26 TAE 26 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted -pole auxiliary contact block 16.3 9 9 16.3 7 3 5 E1331D E1332D 5 E1333D E133D TAE 26 TAE 26 + TP pneumatic timer + WB 75-A on-position latch 5 ø.2 (M) 70 80.5.5 E0117D TAE 26 drilling plan Detailed dimension drawings available in DXF and PDF formats. 1/8 Low Voltage Products 1SBC01D0201

TAE 26 3-pole Contactors Dimensions (in mm) 9 6.3 ø.2 (M) 123 E1335D E1336D 9 6.3 123 E1337D E1338D 5 9 70 80.5 5 69.5 E0126D TAE 26 + VE 5-1 electrical and mechanical interlock unit ø.2 (M) 70 80.5 5 69.5 E0126D TAE 26 + VM 5-1 mechanical interlock unit 5 ø.2 (M) 17 150 70.5 80.5 E0117D E1339D 15. TAE 26 + TA 25 DU thermal O/L relay 9. 1* 6 E130D * For TA 25 DU 32 only Detailed dimension drawings available in DXF and PDF formats. 1/9 Low Voltage Products 1SBC01D0201