Low Voltage Induction Motors

Similar documents
Innovation in motion. Specialists in Rotating Machines

Drive IT Low Voltage Cast Iron Motors. M2000 Range

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

Catalog. Low voltage General performance IE2 high efficiency motors according to EU MEPS

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na

IEC Low Voltage Induction Motors 400 V 50 Hz. Motors for all applications

M3000 Steel Motors. ABB LV Motors M3000 Range

IEC Low Voltage Induction Motors 400 V 50 Hz. Motors for all applications

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

IEC Low Voltage Induction Motors 460 V 60 Hz. Motors for all applications

Industrial Performance Motors. New Aluminum and Cast Iron Motors. Flexibility

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

Explosion and flame-proof cast iron electric motors

: B3; B5; B14; B34; B35; V1

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

Drive IT Low Voltage General Purpose Motors

General Purpose Cast Iron Motors

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

champion series motors

ABB motors Low voltage general performance motors M2000 Cast lron Frames

Low Voltage General Purpose Motors

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

Energy Saving Three Phase Motors

Low Voltage General Purpose Motors

General purpose aluminum motors Technical data for totally enclosed squirrel cage three phase motors, two-speed

Drive IT Low Voltage General Purpose Motors

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

Low Voltage General Purpose Motors

1LG0 Low-voltage Motors

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

COMBROIND001_= THREE PHASE SQUIRREL CAGE INDUCTION MOTORS. IE1 motors MAA - BAA Series IE2 motors MAQ - BAQ Series

Motors for hazardous areas New cast iron motors in sizes

Explosion and flame-proof single phase electric motors

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Aluminium Frame Motors Improved Efficiency EFF2

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

Technical Documentation

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

PLS Open Drip Proof three-phase asynchronous motors. General information

High Efficiency Induction Motors IE2. MarelliMotori MAQ - BAQ SERIES FRAME SIZES ASI.CT GB

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

Technical Documentation

CE Marking. Number of poles. Core Length. Frame size

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

SINGLE PHASE TEFC CAGE MOTORS

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

ARAGON MOTO R S. Three Phase Induction Motors

Drive IT Low Voltage General Purpose Motors

Catalog October 2014 Low voltage General performance motors according to EU MEPS

Series E4F E5F

This catalogue also includes cooling medium pumps of the types DKP and EKP.

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

Standard cast iron Motor

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

Drive IT Low Voltage General Purpose Motors

BFG range BFGC range BFN range

Catalog. Low voltage General performance IE3 efficiency cast iron motors

1 THREE-PHASE CAGE INDUCTION MOTORS

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

Low Voltage 3-Phase Induction Motors. Range 0.55kW to 500kW TOTALLY ENCLOSED FAN-COOLED CAST IRON FRAME SERIES AUSTRALIA & NEW ZEALAND

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

Metric Efficient Line Cast-iron IEC Motors

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW

M3000 motors. Industrial IT

BFG range BFGC range BFN range

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

MG Model C & D 3 phase kw

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

End Suction Range MARCH 2018

Three-phase low voltage squirrel cage motors. Type DOR Frame sizes Helmke Plus

Catalog. Low voltage Industrial performance motors

IP66 GSW GEAR BOX MOTOR SERIES

Energy-efficient Cast Iron Three Phase Induction Motors 50 Hz

IEC Range Three phase IEC low voltage motors - 56 to 355 frames. Single phase motors - 56 to 100 frames Capacitor Run Capacitor Start and Run

LSES high efficiency three-phase asynchronous motors. General information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

General Purpose Energy Efficient Induction Motors series 2SIE

Low Voltage AC Motors

BA series - brake motors. for wind turbine generators

Standardmotoren Standard motors

THREE PHASE ASYNCHRONOUS MOTORS. MS/S Series (frame Aluminum) TC Series (frame Cast iron) Y Series (frame Cast iron)

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

Brake Motors Aluminium Frame Improved Efficiency EFF2

ELK PRODUCT CATALOGUE. elkmotor.com.tr

Catalog June 2016 Low voltage General performance motors

PLSES 4500 IMfinity Platform. IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to to 480 kw

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

TRANSNORM LOW VOLTAGE MOTORS IC 411 TN LV 1 4E5

Low Voltage Smoke Venting Motors

Department/Author Customer name Customer ref. Item name

Transcription:

Low Voltage Induction Motors Catalogue-2009/04 E TAC-C CAST IRON Frame Size 71->355 0,18-315 kw t-telectric.com

Technical features TAC-C motors are designed and manufactured according to IEC34, IEC72, DIN42673, BS4999, AS1359, GB755, GB10069, and Q/JBQS27. High efficiency 1. 1 kw 90 kw 2P and 4P, in S1 duty TAC-C motors are within the class 2 of CEMEP-EU standard, saving energy and operating costs. Voltage ranges A wide range of voltages up to a max. of 690 V available for 50 Hz and 60 Hz. Reliable windings To ensure long lifetime, the windings are made of the latest available materials in class F protection and temperature rise limited to class B in standard motors. Strong corrosion protection The motors are made to withstand aggressive environments as standard and they are designed for long lifetime. For motors with regreasing possibility, they have strong and effective protection against corrosion. Bearings with high load capacity All motors are provided with deep-groove ball bearings, with long lifetime. Cast iron motor in sizes 71-250 are greased for life and those in sizes 280-355 have regreasable bearings as standard. Low noise level The TAC-C range has been designed to minimize motor noise levels by means of improving magnetic and electrical design, ventilator condition, structure size and technology. Winding protection PTC thermistors thermal-switches and anti-condensation heaters on request. Mechanical design Totally enclosed fan cooled IP55 Heavy duty design, manufactured from corrosion resistant cast iron materials to be used in all kinds of environment. The motor is mechanically very strong and robust and as standard designed for additional energy saving through frequency converter drives. Drain holes and plugs as standard in sizes 280 to 355. Powerful refit available The motors satisfy the requirements of a wide range of environments and applications. Improved protection, insulation level, regreasing facilities, dust-proof, sealing rings, rainproofing are all available. A full range of options are listed on pages 15-16. Flexible cable entry direction Terminal boxes are mounted on the top, right or left, of the motors. Terminal boxes of motor size 71-355 can rotate 4x90. All are easy to refit. Code assignment TAC - C 180 M 4 Motor type Cast iron housing Number of pole Core length Motor size Application data - Altitude : maximum 1000 meters above sea level - Ambiant temperature : max. 40 c - Duty cycle : Continuous S1 - Insulation class F - Temperature rise : 80 K 2

Insulation In most cases the standard rated outputs of motors from T-T Electric are based on the temperature rise for insulation class B. Where the temperature rise is according to class F, this is specified in the data tables. However, all motors are designed with class F insulation, which permits a higher temperature rise than class B. The motors, therefore, have a generous overload margin. If temperature rise to class F is allowed, the outputs given in the tables can generally be increased by about 12%. Temperature limits are according to standards. The extra thermal margin when using class F insulation with class B temperature rise makes the motors more reliable. C 180 155 130 120 40 Thermal margin Permissible temperature rise (K) Maximum ambient temperature Insulation class 15 10 10 125 80 105 40 40 40 B F H Ambiant temperatures / high altitudes Motors are designed for a maximum ambianti temperature environment of 40 C and a maximum altitude of 1000 meters above sea level. If temperature and/or altitude is higher, motor should be derated according to tables below. Ambient temperature, C 30 40 45 50 55 60* 70* 80* Permitted output, % of rated output 107 100 96,5 93 87 82 65 50 Height above sea level, m 1000 1500 2000 2500 3000 3500 4000 Permitted output, % of rated output 100 96 92 88 84 80 76 *High temperature grease and reduced greasing intervals recommended Other voltages Motors wound for a given voltage at 50 Hz can also be used for other voltage. Recalculation factors for current and torque are given below, efficiency, power factor and speed remain approximately the same. Guaranteed values available on request. Motor wound for 230V 400V 500V 690V Connected to 50Hz 220V 230V 380V 415V 500V 550V 660V 690V % of values at 400V 50Hz Output 100 100 100 100 100 100 100 100 In 182 174 105 98 80 75 61 58 Is/In 90 100 90 106 100 119 90 100 Ts/Tn 90 100 90 106 100 119 90 100 Tmax/Tn 90 100 90 106 100 119 90 100 3

Motors used at 60 Hz Motors wounded for a given voltage at 50 Hz can be used at 60 Hz without modification, considering recalculations factors here under.. Motor wounded for 50 Hz and 220 V 380 415 500 At 60Hz At 60 Hz, percentages of values at 50 Hz Power Speed Current Is/In Tn Ts/Tn Tmax/Tn 220 100% 120% 98% 83% 83% 70% 85% 255 115 120 100 100 96 95 98 380 100 120 98 83 83 70 85 415 110 120 98 95 91 85 93 440 115 120 100 100 96 95 98 460 120 120 100 105 100 100 103 415 100 120 98 83 83 70 85 460 110 120 98 95 91 85 94 480 115 120 100 100 96 95 98 500 100 120 98 83 83 70 85 550 110 120 98 95 91 85 94 575 115 120 100 100 96 95 98 600 120 120 100 105 100 100 103 Bearings and terminal box The motors are normally fitted with single-row deep groove ball bearings as listed in the table below. Terminal boxes are mounted on top of the motor. The terminal box of motor sizes 71 to 132 can be turned 4 x 90 and in motor sizes 160 to 355 rotated 2 x 180 degree. Protection of the standard terminal box is IP55. The motors are supplied with 2 cable entries as standard according to the table below. Standard bearing type Cable entry Pole D-end N-end mm 71 2,4,6,8 6202 2RS/C3 6202 2RS/C3 2-M25X1,5 80 2,4,6,8 6204 2RS/C3 6204 2RS/C3 2-M25X1,5 90 2,4,6,8 6205 2RS/C3 6205 2RS/C3 2-M25X1,5 100 2,4,6,8 6206 2RS/C3 6206 2RS/C3 2-M25X1,5 112 2,4,6,8 6206 2RS/C3 6206 2RS/C3 2-M32X1,5 132 2,4,6,8 6208 2RSC3 6208 2RS/C3 2-M32X1,5 160 2,4,6,8 6209 2RS/C3 6209 2RS/C3 2-M40X1,5 180 2 6211 2RS/C3 6211 2RS/C3 2-M40X1,5 180 4,6,8 6311 2RS/C3 6211 2RS/C3 2-M40X1,5 200 2 6212 2RS/C3 6212 2RS/C3 2-M50X1,5 200 4,6,8 6312 2RS/C3 6212 2RS/C3 2-M50X1,5 225 2 6312/C3 6312/C3 2-M50X1,5 225 4,6,8 6313/C3 6312/C3 2-M50X1,5 250 2 6313/C3 6313/C3 2-M63X1,5 Standard bearing type Cable entry Pole D-end N-end mm 250 4,6,8 6314/C3 6313/C3 2-M63X1,5 280 2 6314/C3 6314/C3 2-M63X1,5 280 4,6,8 6317/C3 6314/C3 2-M63X1,5 315 2 6317/C3 6317/C3 2-M63X1,5 315 4,6,8,10 N319 6319/C3 2-M63X1,5 355 2 6319/C3 6319/C3 2-M63X1,5 355 4,6,8,10 N322 6322/C3 2-M63X1,5 Regreasable bearings available from size 160 (included) Bearing seals : radial seal up to frame size 225 (included) - axial seal from 250 to 355 (included) 4

Motors for EU efficiency levels T-T Electric have a motor range to meet or exceed the minimum efficiencies stated in the highest level of the EU agreement of LV motors. These efficiency levels apply to 2- and 4-pole, three phase squirrel cage induction motors, rated for 400 V, 50 Hz, with S1 duty class with the output 1.1 to 90 kw which account for the largest volume on the market. Three phase induction motors, 400 V 50 Hz T-T Electric motor efficiency levels 2 pole 4 pole 100 100 95 EFF1 95 EFF1 Efficiency (%) 90 85 80 75 EFF2 EFF3 Efficiency (%) 90 85 80 75 EFF2 EFF3 Output (kw) Output (kw) EU efficiency classes Output kw 2 pole Limit EFF2/EFF3 2 pole 4 pole Limit EFF2/EFF3 EFF1/EFF2 1,1 76,2 82,8 76,2 83,8 1,5 78,5 84,1 78,5 85 EFF1/EFF2 2,2 81 85,6 81 86,4 3 82,6 86,7 82,6 87,4 4 84,2 87,6 84,2 88,3 5,5 85,7 88,6 85,7 89,2 7,5 87 89,5 87 90,1 11 88,4 90,5 88,4 91 15 89,4 91,3 89,4 91,8 18,5 90 91,8 90 92,2 22 90,5 92,2 90,5 92,6 30 91,4 92,9 91,4 93,2 37 92 93,3 92 93,6 45 92,5 93,7 92,5 93,9 55 93 94 93 94,2 75 93,6 94,6 93,6 94,7 90 93,9 95 93,9 95 5

Technical Data H71-355 - 50 Hz Output kw designation Speed n r/min Efficiency Full load 100% 3000 r/min = 2 poles, 400V 50Hz 3/4 load 75% Power factor cos Current Torque Moment of inertie inj=gd2/4 kgm2 Weight kg) In A Is In Tn Nm Ts Tn Tmax Tn 0,37 TAC-C 71A2 2780 70,0 68,0 0,82 0,9 6,1 1,3 2,2 2,2 0,0003 10 59 0,55 TAC-C 71B2 2785 73,0 72,4 0,82 1,3 6,1 1,9 2,2 2,2 0,00037 11 59 0,75 TAC-C 80A2 2840 75,0 75,5 0,85 1,7 6,1 2,5 2,2 2,2 0,00091 16 60 1,1 TAC-C 80B2 2855 78,0 77,9 0,85 2,4 7,0 3,7 2,2 2,2 0,00107 17 61 1,5 TAC-C 90S2 2850 79,0 79,0 0,87 3,2 7,0 5,0 2,2 2,2 0,00135 21 64 2,2 TAC-C 90L2 2850 81,5 81,8 0,86 4,5 7,0 7,4 2,2 2,2 0,00163 24 64 3 TAC-C 100L2 2860 83,0 83,2 0,88 5,9 7,0 10 2,2 2,2 0,00402 33 68 4 TAC-C 112M2 2900 85,0 84,6 0,90 7,6 7,0 13,2 2,2 2,2 0,00671 42 70 5,5 TAC-C 132SA2 2920 87,5 87,9 0,89 10,2 7,0 18 2,2 2,2 0,01241 58 73 7,5 TAC-C 132SB2 2920 88,5 90,1 0,90 13,6 7,0 24,5 2,2 2,2 0,01491 63 73 11 TAC-C 160MA2 2930 90,0 90,5 0,89 19,8 6,5 35,9 2,5 3,0 0,0436 112 75 15 TAC-C 160MB2 2920 90,0 90,1 0,89 27 6,5 49 2,5 3,2 0,0551 122 75 18,5 TAC-C 160L2 2930 90,5 90,9 0,90 32,8 6,5 60,3 2,5 3,2 0,06549 142 75 22 TAC-C 180M2 2940 90,8 91,0 0,90 38,9 6,5 71,5 2,3 2,8 0,08805 170 78 30 TAC-C 200LA2 2955 91,4 91,1 0,90 52,6 6,5 97 2,2 2,7 0,14821 235 84 37 TAC-C 200LB2 2955 92,2 91,8 0,90 64,4 6,5 120 2,3 2,7 0,16822 254 84 45 TAC-C 225M2 2970 92,6 92,2 0,89 78,8 7,0 145 2,5 2,8 0,29345 328 84 55 TAC-C 250M2 2960 93,4 91,7 0,89 96,5 7,5 178 2,4 3,0 0,3784 390 87 75 TAC-C 280S2 2972 94,0 92,3 0,90 128 7,5 241 2,5 3,3 0,587 504 88 90 TAC-C 280M2 2972 94,3 92,4 0,90 154 7,5 289 2,3 3,2 0,615 560 88 110 TAC-C 315S2 2980 94,0 92,2 0,91 187 7,1 353 1,8 2,2 1,4083 910 91 132 TAC-C 315M2 2980 94,5 93,0 0,91 223 7,1 423 1,8 2,2 1,5584 1010 91 160 TAC-C 315LA2 2979 94,6 93,5 0,92 267 7,2 513 1,8 2,2 1,7256 1070 91 200 TAC-C 315LB2 2978 94,8 94,0 0,92 332 7,2 641 1,8 2,2 1,9405 1120 91 250 TAC-C 355M2 2980 95,4 94,5 0,92 416 7,1 802 2,3 2,8 3,05 1438 92 315 TAC-C 355L2 2980 96,0 95,3 0,92 520 6,9 1011 2,0 2,8 3,6 1726 92 Sound pressure level Lp db(a) Output kw designation Speed n r/min Efficiency Full load 100% 1500 r/min = 4 poles, 400V 50Hz Current Torque Moment 3/4 Power of inertie load factor In Is Tn Ts Tmax inj=gd2/4 75% cos A In Nm Tn Tn kgm2 Weight kg) 0,25 TAC-C 71A4 1395 65,5 63,3 0,72 0,8 5,2 1,7 2,1 2,0 0,00053 11 46 0,37 TAC-C 71B4 1395 68,5 69,4 0,75 1,0 5,2 2,5 2,1 2,0 0,00066 11 48 0,55 TAC-C 80A4 1410 73,5 71,4 0,72 1,5 5,2 3,7 2,4 2,0 0,00145 16 49 0,75 TAC-C 80B4 1415 74,5 75,2 0,76 1,9 6,0 5,1 2,4 2,2 0,00174 17 49 1,1 TAC-C 90S4 1400 77,5 77,8 0,78 2,6 6,0 7,5 2,3 2,2 0,00254 21 55 1,5 TAC-C 90L4 1390 78,5 79,2 0,79 3,5 6,0 10,3 2,3 2,2 0,00317 25 55 2,2 TAC-C 100LA4 1430 81,5 82,3 0,81 4,9 a6,0 14,7 2,3 2,2 0,00679 32 56 3 TAC-C 100LB4 1420 82,8 82,5 0,83 6,3 6,5 20,2 2,3 2,2 0,00862 36 56 4 TAC-C 112M4 1430 85,0 84,6 0,82 8,3 6,5 26,7 2,3 2,2 0,01306 45 59 5,5 TAC-C 132S4 1430 86,0 87,1 0,85 10,9 6,5 36,7 2,3 2,2 0,02673 60 62 7,5 TAC-C 132M4 1440 88,5 88,3 0,85 14,4 6,5 49,7 2,3 2,2 0,03432 73 62 11 TAC-C 160M4 1460 89,5 90,0 0,85 20,9 6,5 72,0 2,4 2,8 0,06543 116 69 15 TAC-C 160L4 1460 90,0 90,4 0,86 28,0 6,5 98,1 2,3 2,4 0,09349 137 69 18,5 TAC-C 180M4 1470 91,0 90,9 0,86 34,1 6,5 120 2,3 3,0 0,16049 170 69 22 TAC-C 180L4 1470 92,0 90,0 0,88 39,4 6,5 143 2,4 3,0 0,18046 186 69 30 TAC-C 200L4 1470 92,2 91,8 0,88 53,4 6,5 195 2,2 2,8 0,2819 254 74 37 TAC-C 225S4 1480 92,6 91,2 0,85 67,9 7,0 239 2,2 2,8 0,37 308 76 45 TAC-C 225M4 1480 92,8 91,7 0,87 80,5 7,0 290 2,2 2,8 0,42 335 76 55 TAC-C 250M4 1480 93,4 91,3 0,87 98,5 7,0 355 2,4 3,0 0,78 450 79 75 TAC-C 280S4 1480 94,0 93,9 0,87 133 6,5 484 2,4 2,6 1,1 534 81 90 TAC-C 280M4 1480 94,3 94,6 0,87 159 7,2 581 2,3 2,8 1,35 592 81 110 TAC-C 315S4 1486 94,5 93,5 0,88 192 6,9 707 2,1 2,2 2,8596 930 83 132 TAC-C 315M4 1486 94,8 94,0 0,88 229 6,9 848 2,1 2,2 3,1848 1030 83 160 TAC-C 315LA4 1485 94,9 94,5 0,89 275 6,9 1029 2,1 2,2 3,6765 1050 89 200 TAC-C 315LB4 1485 95,0 94,2 0,89 343 6,9 1286 2,1 2,2 4,2516 1100 89 250 TAC-C 355M4 1490 95,3 94,5 0,90 421 6,9 1594 2,1 2,6 6,77 1546 90 315 TAC-C 355L4 1490 95,6 94,8 0,90 528 7,0 2008 2,1 2,3 8,2 1821 90 6 Sound pressure level Lp db(a)

Technical Data H71-355 - 60 Hz Output kw Output kw designation designation Speed n r/min Speed n r/min Efficiency Full load 100% Efficiency Full load 100% 3600 r/min = 2 poles, 460V 60Hz Current Torque Moment Power of inertie factor In Is Tn Ts Tmax inj=gd2/4 cos A In Nm Tn Tn kgm2 1800 r/min = 4 poles, 460V 60Hz Power factor cos Current Torque Moment of inertie In Is Tn Ts Tmax inj=gd2/4 A In Nm Tn Tn kgm2 Weight kg) 0,43 TAC-C 71A2 3340 70,0 0,83 1,0 6,1 1,2 2,2 2,2 0,0003 10 59 0,63 TAC-C 71B2 3340 73,0 0,84 1,4 6,1 1,8 2,2 2,2 0,00037 11 59 0,86 TAC-C 80A2 3410 75,0 0,88 1,7 6,1 2,4 2,2 2,2 0,00091 16 60 1,27 TAC-C 80B2 3430 78,0 0,88 2,4 7,0 3,5 2,2 2,2 0,00107 17 61 1,73 TAC-C 90S2 3420 79,0 0,87 3,3 7,0 4,8 2,2 2,2 0,00135 21 64 2,53 TAC-C 90L2 3440 81,5 0,86 4,7 7,0 7,0 2,2 2,2 0,00163 24 64 3,45 TAC-C 100L2 3430 83,0 0,89 6,1 7,0 9,6 2,2 2,2 0,00402 33 68 4,6 TAC-C 112M2 3480 85,0 0,91 7,9 7,0 12,6 2,2 2,2 0,00671 42 70 6,33 TAC-C 132SA2 3510 87,5 0,90 10,6 7,0 17,2 2,2 2,2 0,01241 58 73 8,6 TAC-C 132SB2 3510 88,5 0,91 14,0 7,0 23,4 2,2 2,2 0,01491 63 73 12,7 TAC-C 160MA2 3515 91,5 0,91 20,0 6,5 34,5 2,5 3,0 0,0436 112 75 17,3 TAC-C 160MB2 3517 91,6 0,91 27,2 6,5 47,0 2,5 3,2 0,0551 122 75 21,3 TAC-C 160L2 3520 91,8 0,91 33,5 6,5 57,8 2,5 3,2 0,06549 142 75 25,3 TAC-C 180M2 3528 92,1 0,90 40,1 6,5 68,5 2,3 2,8 0,08805 170 78 34,5 TAC-C 200LA2 3550 91,4 0,91 54,4 6,5 92,8 2,2 2,7 0,14821 235 84 42,6 TAC-C 200LB2 3550 91,2 0,91 67,3 6,5 115 2,3 2,7 0,16822 254 84 51,8 TAC-C 225M2 3560 92,2 0,90 81,9 7,0 139 2,5 2,8 0,29345 328 84 63 TAC-C 250M2 3559 93,8 0,91 96,9 7,5 169 2,4 3,0 0,3784 390 87 86 TAC-C 280S2 3565 94,0 0,91 132 7,5 230 2,5 3,3 0,587 504 88 104 TAC-C 280M2 3565 94,3 0,91 159 7,5 279 2,3 3,2 0,615 560 88 127 TAC-C 315S2 3576 94,5 0,92 183 7,1 339 1,8 2,2 1,4083 910 91 152 TAC-C 315M2 3576 95,0 0,92 218 7,1 406 1,8 2,2 1,5584 1010 91 184 TAC-C 315LA2 3575 95,0 0,93 261 7,2 492 1,8 2,2 1,7256 1070 91 230 TAC-C 315LB2 3575 95,2 0,93 326 7,2 614 1,8 2,2 1,9405 1120 91 287,5 TAC-C 355M2 3576 95,7 0,92 412 7,1 769 2,2 2,7 3,05 1438 92 362,5 TAC-C 355L2 3576 96,2 0,92 517 6,9 970 1,9 2,7 3,6 1726 92 Weight kg) 0,29 TAC-C 71A4 1670 65,5 0,74 0,8 5,2 1,66 2,1 2,0 0,00053 11 46 0,43 TAC-C 71B4 1670 68,5 0,76 1,1 5,2 2,46 2,1 2,0 0,00066 11 48 0,63 TAC-C 80A4 1690 73,5 0,75 1,5 5,2 3,56 2,4 2,0 0,00145 16 49 0,86 TAC-C 80B4 1680 74,5 0,77 2,0 6,0 4,89 2,4 2,2 0,00174 17 49 1,27 TAC-C 90S4 1680 77,5 0,78 2,8 6,0 7,22 2,3 2,2 0,00254 21 55 1,73 TAC-C 90L4 1670 78,5 0,8 3,6 6,0 9,89 2,3 2,2 0,00317 25 55 2,53 TAC-C 100LA4 1720 81,5 0,82 5,0 6,0 14,05 2,3 2,2 0,00679 32 56 3,45 TAC-C 100LB4 1700 82,8 0,86 6,4 6,5 19,38 2,3 2,2 0,00862 36 56 4,6 TAC-C 112M4 1720 85,0 0,83 8,6 6,5 25,54 2,3 2,2 0,01306 45 59 6,33 TAC-C 132S4 1700 86,0 0,86 11,2 6,5 35,56 2,3 2,2 0,02673 60 62 8,6 TAC-C 132M4 1730 88,5 0,86 14,8 6,5 47,47 2,3 2,2 0,03432 73 62 12,7 TAC-C 160M4 1755 91,0 0,87 21,1 6,5 69,11 2,4 3,8 0,06543 116 69 17,3 TAC-C 160L4 1752 91,6 0,88 28,2 6,5 94,3 2,3 2,4 0,09349 137 69 21,3 TAC-C 180M4 1764 92,8 0,87 34,6 6,5 115,3 2,3 3,0 0,16049 170 69 25,3 TAC-C 180L4 1764 93,1 0,89 40,1 6,5 137 2,4 3,1 0,18046 186 69 34,5 TAC-C 200L4 1765 92,6 0,89 55,0 6,5 186,7 2,2 2,8 0,2819 254 74 42,6 TAC-C 225S4 1770 92,6 0,85 71,0 7,0 229,8 2,2 2,8 0,37 308 76 51,8 TAC-C 225M4 1770 92,8 0,88 83,2 7,0 279,5 2,2 2,8 0,42 335 76 63 TAC-C 250M4 1779 93,8 0,89 99,7 7,0 338,2 2,4 3,0 0,78 450 79 86 TAC-C 280S4 1775 94,0 0,88 136 6,5 462,7 2,4 2,6 1,1 534 81 104 TAC-C 280M4 1775 94,3 0,88 164 7,2 559,5 2,3 2,8 1,35 592 81 127 TAC-C 315S4 1783 95,0 0,89 189 6,9 680,2 2,1 2,2 2,8596 930 83 152 TAC-C 315M4 1783 95,1 0,89 222 6,9 814,1 2,1 2,2 3,1848 1030 83 184 TAC-C 315LA4 1782 95,3 0,90 269 6,9 986,1 2,1 2,2 3,6765 1050 89 230 TAC-C 315LB4 1782 95,4 0,90 336 6,9 1232,6 2,1 2,2 4,2516 1100 89 287,5 TAC-C 355M4 1788 95,6 0,91 417 6,9 1538 2,0 2,5 6,77 1546 90 362,5 TAC-C 355L4 1788 95,8 0,91 525 7,0 1939 2,0 2,2 8,2 1821 90 7 Sound pressure level Lp db(a) Sound pressure level Lp db(a)

Technical Data H71-355 - 50 Hz Output kw designation Speed n r/min Efficiency Full load 100% 1000 r/min = 6 poles, 400V 50Hz Current Torque Moment 3/4 Power of inertie load factor In Is Tn Ts Tmax inj=gd2/4 75% cos A In Nm Tn Tn kgm2 Weight kg) 0,18 TAC-C 71A6 910 55,0 50,1 0,65 0,7 4,0 1,9 1,8 1,8 0,00056 10 45 0,25 TAC-C 71B6 890 60,0 58,3 0,65 0,9 4,0 2,7 1,8 1,8 0,00074 11 45 0,37 TAC-C 80A6 930 63,0 63,2 0,66 1,3 5,0 3,8 1,9 1,8 0,00159 17 48 0,55 TAC-C 80B6 925 65,0 65,1 0,68 1,8 5,0 5,7 1,9 1,8 0,00196 18 48 0,75 TAC-C 90S6 920 71,0 70,2 0,72 2,1 5,0 7,8 2,0 2,2 0,00292 21 51 1,1 TAC-C 90L6 920 73,0 73,1 0,74 2,9 5,0 11,4 2,0 2,2 0,00379 25 51 1,5 TAC-C 100L6 940 76,0 75,3 0,77 3,8 5,5 15,2 2,0 2,2 0,00999 32 54 2,2 TAC-C 112M6 940 80,0 81,2 0,76 5,2 5,5 22,4 2,0 2,2 0,01559 40 57 3 TAC-C 132S6 960 82,5 83,6 0,78 6,7 6,5 29,8 2,0 2,2 0,03116 55 59 4 TAC-C 132MA6 960 84,0 84,2 0,77 8,9 6,5 39,8 2,0 2,2 0,04074 65 59 5,5 TAC-C 132MB6 960 86,0 85,6 0,79 11,7 6,5 54,7 2,0 2,2 0,05332 75 59 7,5 TAC-C 160M6 970 88,0 85,3 0,78 15,8 6,0 73,8 2,0 2,3 0,09231 119 64 11 TAC-C 160L6 970 88,5 88,6 0,78 23 6,0 108 2,2 2,3 0,1297 140 65 15 TAC-C 180L6 980 89,0 89,1 0,82 29,7 6,0 146 2,3 2,8 0,2418 180 66 18,5 TAC-C 200LA6 980 90,3 90,2 0,82 36,1 6,0 180 2,2 2,8 0,34174 231 67 22 TAC-C 200LB6 980 90,4 90,3 0,83 42,3 6,0 214 2,1 2,8 0,46837 254 67 30 TAC-C 225M6 980 90,8 89,2 0,78 61,1 6,6 292 2,2 2,8 0,62691 308 69 37 TAC-C 250M6 980 92,2 92,4 0,88 66,5 6,8 361 2,3 2,8 0,97 382 71 45 TAC-C 280S6 982 92,6 91,3 0,86 82 6,5 438 2,3 2,4 1,25 482 72 55 TAC-C 280M6 982 93,0 91,2 0,87 98,4 7,0 535 2,3 2,5 1,485 532 73 75 TAC-C 315S6 990 93,5 93,2 0,86 135 7,4 724 2,0 2,0 3,1942 920 78 90 TAC-C 315M6 990 93,8 91,9 0,86 162 7,4 868 2,0 2,0 3,723 1010 73 110 TAC-C 315LA6 990 94,3 93,5 0,87 194 6,8 1061 2,0 2,0 4,2564 1060 73 132 TAC-C 315LB6 990 94,5 93,8 0,87 232 6,8 1273 2,0 2,0 5,1577 1120 73 160 TAC-C 355MA6 990 94,7 93,9 0,89 274 6,8 1530 2,1 2,4 7,8 1360 78 200 TAC-C 355MB6 990 94,9 94,0 0,89 342 6,7 1913 2,0 2,3 9,1 1551 78 250 TAC-C 355L6 990 95,1 94,2 0,89 422 6,7 2391 2,0 2,4 11,4 2057 78 Sound pressure level Lp db(a) Output kw designation Speed n r/min Efficiency Full load 100% 750 r/min = 8 poles, 400V 50Hz Current Torque Moment 3/4 Power of inertie load factor In Is Tn Ts Tmax inj=gd2/4 75% cos A In Nm Tn Tn kgm2 Weight kg) 0,18 TAC-C 80A8 700 51,0 50,1 0,6 0,9 3,3 2,46 1,8 1,9 0,00111 16 45 0,25 TAC-C 80B8 700 54,5 53,3 0,6 1,1 3,6 3,41 1,8 1,9 0,00326 17 45 0,37 TAC-C 90S8 700 62,5 62,1 0,61 1,4 4,4 5,05 1,8 1,9 0,00541 21 49 0,55 TAC-C 90L8 700 63,5 63,3 0,61 2,1 4,7 7,5 1,8 2,0 0,00756 24 49 0,75 TAC-C 100LA8 700 70,0 70,1 0,64 2,4 5,0 10,23 1,8 2,0 0,00971 31 56 1,1 TAC-C 100LB8 700 71,5 70,3 0,65 3,5 5,0 15,01 1,8 2,0 0,01186 34 56 1,5 TAC-C 112M8 700 75,0 75,4 0,68 4,3 5,0 20,46 1,8 2,0 0,1559 42 58 2,2 TAC-C 132S8 710 81,0 81,8 0,70 5,6 5,5 29,59 1,8 2,0 0,03625 56 58 3 TAC-C 132M8 710 81,0 81,4 0,75 7,1 5,5 40,35 1,8 2,0 0,04141 64 59 4 TAC-C 160MA8 720 84,0 84,0 0,73 9,4 5,5 53,06 2,1 2,5 0,0676 105 61 5,5 TAC-C 160MB8 720 85,5 85,6 0,74 12,6 5,5 72,95 2,1 2,5 0,09524 125 61 7,5 TAC-C 160L8 720 86,5 85,8 0,74 16,9 5,5 99,5 2,1 2,5 0,12122 142 61 11 TAC-C 180L8 730 87,7 87,0 0,77 23,5 5,4 143,9 2,0 2,8 0,23645 176 64 15 TAC-C 200L8 730 89,0 89,4 0,76 32,0 5,5 196,2 2,3 2,8 0,37103 235 66 18,5 TAC-C 225S8 740 90,0 89,1 0,75 39,6 5,5 238,8 2,1 2,8 0,53287 290 68 22 TAC-C 225M8 740 90,5 8,16 0,75 46,8 6,0 283,9 2,2 2,8 0,65825 302 68 30 TAC-C 250M8 740 91,3 90,1 0,79 60 6,5 387,2 2,3 2,6 0,975 392 70 37 TAC-C 280S8 740 91,8 91,7 0,79 74,2 6,0 477,5 2,1 2,6 1,25 488 71 45 TAC-C 280M8 740 92,4 91,1 0,79 89,5 6,0 580,7 2,1 2,7 1,485 548 71 55 TAC-C 315S8 740 92,8 91,5 0,82 105 6,9 709,8 1,8 2,0 3,6842 930 68 75 TAC-C 315M8 740 93,0 91,9 0,82 143 7,0 967,9 1,8 2,0 4,9591 1010 71 90 TAC-C 315LA8 740 93,8 93,2 0,82 170 7,1 1161,5 1,8 2,0 5,8205 1070 71 110 TAC-C 315LB8 740 94,0 92,4 0,82 204 6,4 1419,6 1,8 2,0 6,737 1140 71 132 TAC-C 355 MA8 745 93,7 93 0,82 248 6,4 1692,1 1,8 2,0 7,9 2000 78 160 TAC-C 355 MB8 745 94,4 94,1 0,82 299 6,4 2051 1,8 2,0 10,3 2150 78 200 TAC-C 355 L8 745 94,5 93,9 0;83 368 6,4 2563,4 1,8 2,0 12,3 2250 78 8 Sound pressure level Lp db(a)

Technical Data H71-355 - 60 Hz Output kw designation Speed n r/min Efficiency Full load 100% 1200 r/min = 6 poles, 460V 60Hz Current Torque Moment Power of inertie factor In Is Tn Ts Tmax inj=gd2/4 cos A In Nm Tn Tn kgm2 Weight kg) 0,21 TAC-C 71A6 1090 55,0 0,66 0,8 4,0 1,8 1,8 1,8 0,00056 10 45 0,29 TAC-C 71B6 1070 60,0 0,66 1,0 4,0 2,6 1,8 1,8 0,00074 11 45 0,43 TAC-C 80A6 1101 63,0 0,67 1,3 5,0 3,7 1,9 1,9 0,00159 17 48 0,63 TAC-C 80B6 1101 65,0 0,68 1,9 5,0 5,5 1,9 1,9 0,00196 18 48 0,86 TAC-C 90S6 1105 71,0 0,73 2,2 5,0 7,4 2,0 2,2 0,00292 21 51 1,27 TAC-C 90L6 1100 73,0 0,75 3,0 5,0 11,0 2,0 2,2 0,00379 25 51 1,73 TAC-C 100L6 1130 76,0 0,77 3,9 5,5 14,6 2,0 2,2 0,00999 32 54 2,53 TAC-C 112M6 1145 80,0 0,77 5,4 5,5 21,1 2,0 2,2 0,01559 40 57 3,45 TAC-C 132S6 1150 82,5 0,79 7,0 6,5 28,7 2,0 2,2 0,03116 55 59 4,6 TAC-C 132MA6 1150 84,0 0,79 9,1 6,5 38,2 2,0 2,2 0,04074 65 59 6,33 TAC-C 132MB6 1150 86,0 0,80 12,1 6,5 52,6 2,0 2,2 0,05332 75 59 8,6 TAC-C 160M6 1167 88,0 0,79 16,2 6,0 70,4 2,0 2,3 0,09231 119 64 12,7 TAC-C 160L6 1166 89,9 0,80 23,2 6,0 104 2,2 2,3 0,1297 140 65 17,3 TAC-C 180L6 1176 91,1 0,83 30,0 6,0 141 2,3 2,8 0,2418 180 66 21,3 TAC-C 200LA6 1175 90,9 0,84 36,6 6,0 173 2,2 2,8 0,34174 231 67 25,3 TAC-C 200LB6 1175 90,0 0,85 43,4 6,0 206 2,1 2,8 0,46837 254 67 34,5 TAC-C 225M6 1180 90,9 0,78 63,9 6,6 279 2,2 2,8 0,62691 308 69 42,6 TAC-C 250M6 1179 92,8 0,89 67,8 6,8 345 2,3 2,8 0,97 382 71 51,8 TAC-C 280S6 1175 92,6 0,87 84,4 6,5 421 2,3 2,4 1,25 482 72 63 TAC-C 280M6 1175 93,0 0,88 101 7,0 512 2,3 2,5 1,485 532 73 86 TAC-C 315S6 1188 93,8 0,87 132 7,4 691 2,0 2,0 3,1942 920 78 104 TAC-C 315M6 1188 94,0 0,87 160 7,4 836 2,0 2,0 3,723 1010 73 127 TAC-C 315LA6 1188 94,5 0,88 192 6,8 1021 2,0 2,0 4,2564 1060 73 152 TAC-C 315LB6 1188 95,0 0,88 228 6,8 1222 2,0 2,0 5,1577 1120 73 184 TAC-C 355MA6 1188 94,9 0,90 270 6,8 1481 2,0 2,3 7,8 1360 78 230 TAC-C 355MB6 1188 95,1 0,90 337 6,7 1852 1,9 2,2 9,1 1551 78 287,5 TAC-C 355L6 1188 95,3 0,90 421 6,7 2315 1,9 2,3 11,4 2057 78 Sound pressure level Lp db(a) Output kw designation Speed n r/min Efficiency Full load 100% 900 r/min = 8 poles, 460V 60Hz Current Torque Moment Power of inertie factor In Is Tn Ts Tmax inj=gd2/4 cos A In Nm Tn Tn kgm2 Weight kg) 0,21 TAC-C 80A8 820 53,8 0,54 0,9 3,3 2,5 1,8 1,9 0,00111 16 45 0,29 TAC-C 80B8 820 58,6 0,55 1,1 3,6 3,4 1,8 1,9 0,00326 17 45 0,43 TAC-C 90S8 830 61,7 0,56 1,6 4,4 5,0 1,8 1,9 0,00541 21 49 0,63 TAC-C 90L8 830 63,8 0,58 2,1 4,7 7,3 1,8 2,0 0,00756 24 49 0,86 TAC-C 100LA8 840 70,0 0,64 2,5 5,0 9,8 1,8 2,0 0,00971 31 56 1,27 TAC-C 100LB8 840 71,5 0,65 3,6 5,0 14,4 1,8 2,0 0,01186 34 56 1,73 TAC-C 112M8 850 75,0 0,69 4,4 5,0 19,4 1,8 2,0 0,1559 42 58 2,53 TAC-C 132S8 860 81,0 0,71 5,8 5,5 28,1 1,8 2,0 0,03625 56 58 3,45 TAC-C 132M8 860 81,0 0,77 7,3 5,5 38,3 1,8 2,0 0,04141 64 59 4,6 TAC-C 160MA8 865 88,0 0,76 9,0 5,5 50,8 2,1 2,5 0,0676 105 61 6,33 TAC-C 160MB8 866 85,9 0,76 12,7 5,5 69,8 2,1 2,5 0,09524 125 61 8,6 TAC-C 160L8 865 86,5 0,77 16,9 5,5 94,9 2,1 2,5 0,12122 142 61 12,7 TAC-C 180L8 876 86,0 0,78 24,9 5,4 139 2,0 2,8 0,23645 176 64 17,3 TAC-C 200L8 875 89,0 0,78 32,7 5,5 189 2,3 2,8 0,37103 235 66 21,3 TAC-C 225S8 890 90,0 0,75 41,4 5,5 229 2,1 2,8 0,53287 290 68 25,3 TAC-C 225M8 890 90,5 0,76 48,3 6,0 272 2,2 2,8 0,65825 302 68 34,5 TAC-C 250M8 891 92,1 0,80 61,5 6,5 370 2,3 2,6 0,975 392 70 42,6 TAC-C 280S8 885 91,8 0,80 76,1 6,0 460 2,1 2,6 1,25 488 71 51,8 TAC-C 280M8 885 92,4 0,80 92 6,0 559 2,1 2,7 1,485 548 71 63 TAC-C 315S8 888 93,2 0,83 102 6,9 678 1,8 2,0 3,6842 930 68 86 TAC-C 315M8 888 93,5 0,83 139 7,0 925 1,8 2,0 4,9591 1010 71 104 TAC-C 315LA8 888 94,0 0,83 164 7,1 1119 1,8 2,0 5,8205 1070 71 127 TAC-C 315LB8 888 94,5 0,84 201 6,4 1366 1,8 2,0 6,737 1140 71 152 TAC-C 355 MA8 745 94 0,83 245 6,4 1948 1,8 2,0 7,9 2000 78 184 TAC-C 355 MB8 745 94,8 0,83 294 6,4 2359 1,8 2 10,3 2150 78 230 TAC-C 355 L8 745 94,9 0,84 362,1 6,4 2948 1,8 2 12,3 2250 78 9 Sound pressure level Lp db(a)

Dimension drawing, H71-355, B3 TAC-C Pole A AA AB AC B BB C D E F G GD DB EG 71 2-6 112 24 150 136,5 90 108 45 14 j6 30 5 11 5 M5 12,5 80 2-8 125 35 165 155 100 130 50 19 j6 40 6 15,5 6 M6 16 90S 2-8 140 36 180 169 100 140 56 24 j6 50 8 20 7 M8 19 90L 2-8 140 36 180 169 125 165 56 24 j6 50 8 20 7 M8 19 100L 2-8 160 40 205 195 140 175 63 28 j6 60 8 24 7 M10 22 112M 2-8 190 45 230 217 140 180 70 28 j6 60 8 24 7 M10 22 132S 2-8 216 55 270 260 140 190 89 38 k6 80 10 33 8 M12 28 132M 2-8 216 55 270 260 178 230 89 38 k6 80 10 33 8 M12 28 160M 2-8 254 65 320 314 210 260 108 42 k6 110 12 37 8 M16 36 160L 2-8 254 65 320 314 254 305 108 42 k6 110 12 37 8 M16 36 180M 2-4 279 70 355 352 241 315 121 48 k6 110 14 42,5 9 M16 36 180L 4-8 279 70 355 352 279 350 121 48 k6 110 14 42,5 9 M16 36 200L 2-8 318 70 395 395 305 370 133 55 m6 110 16 49 10 M20 39 225S 4-8 356 75 435 442 286 370 149 60 m6 140 18 53 11 M20 39 225M 2 356 75 435 442 311 395 149 55 m6 110 16 49 10 M20 39 225M 4-8 356 75 435 442 311 395 149 60 m6 140 18 53 11 M20 39 250M 2 406 80 490 480 349 445 168 60 m6 140 18 53 11 M20 39 250M 4-8 406 80 490 480 349 445 168 65 m6 140 18 58 11 M20 39 280S 2 457 85 550 535 368 490 190 65 m6 140 18 58 11 M20 39 280S 4-8 457 85 550 535 368 490 190 75 m6 140 20 67,5 12 M20 39 280M 2 457 85 550 535 419 540 190 65 m6 140 18 58 11 M20 39 280M 4-8 457 85 550 535 419 540 190 75 m6 140 20 67,5 12 M20 39 315S 2 508 120 635 620 406 570 216 65 M6 140 18 58 11 M20 42 315S 4-8 508 120 635 620 406 570 216 80 m6 170 22 71 14 M20 42 315M 2 508 120 635 620 457 680 216 65 m6 140 18 58 11 M20 42 315M 4-8 508 120 635 620 457 680 216 80 m6 170 22 71 14 M20 42 315L 2 508 120 635 620 508 680 216 65 m6 140 18 58 11 M20 42 315L 4-8 508 120 635 620 508 680 216 80 m6 170 22 71 14 M20 42 355M 2 610 120 730 710 560 750 254 75 m6 140 20 67.5 12 M20 42 355M 4-6 610 120 730 710 560 750 254 95 m6 170 25 86 16 M24 47 355L 2 610 120 730 710 630 750 254 75 m6 140 20 67.5 12 M20 42 355L 4-6 610 120 730 710 630 750 254 95 m6 170 25 86 16 M24 47 10

Dimension drawing, H71-355, B5-B35 TAC-C Pole H HA HD K L LD LA M N P S T 71 2-6 71 10 195 7 255 100 10 130 110 160 4-10 3,5 80 2-8 80 12 214 10 295 115 12 165 130 200 4-12 3,5 90S 2-8 90 12 250 10 320 125 12 165 130 200 4-12 3,5 90L 2-8 90 12 250 10 345 125 12 165 130 200 4-12 3,5 100L 2-8 100 14 270 12 385 143 13 215 180 250 4-15 4 112M 2-8 112 15 300 12 400 147 14 215 180 250 4-15 4 132S 2-8 132 18 345 12 470 182 14 265 230 300 4-15 4 132M 2-8 132 18 345 12 510 182 14 265 230 300 4-15 4 160M 2-8 160 20 420 15 615 256 15 300 250 350 4-19 5 160L 2-8 160 20 420 15 670 256 15 300 250 350 4-19 5 180M 2-4 180 22 455 15 700 271 15 300 250 350 4-19 5 180L 4-8 180 22 455 15 740 271 15 300 250 350 4-19 5 200L 2-8 200 25 505 19 770 296 17 350 300 400 4-19 5 225S 4-8 225 28 555 19 815 329 20 400 350 450 8-19 5 225M 2 225 28 555 19 820 299 20 400 350 450 8-19 5 225M 4-8 225 28 555 19 845 329 20 400 350 450 8-19 5 250M 2 250 30 615 24 910 347 22 500 450 550 8-19 5 250M 4-8 250 30 615 24 910 347 22 500 450 550 8-19 5 280S 2 280 35 680 24 985 355 22 500 450 550 8-19 5 280S 4-8 280 35 680 24 985 355 22 500 450 550 8-19 5 280M 2 280 35 680 24 1035 355 22 500 450 550 8-19 5 280M 4-8 280 35 680 24 1035 355 22 500 450 550 8-19 5 315S 2 315 45 845 28 1190 397 22 600 550 660 8-24 6 315S 4-8 315 45 845 28 1220 427 22 600 550 660 8-24 6 315M 2 315 45 845 28 1300 397 22 600 550 660 8-24 6 315M 4-8 315 45 845 28 1330 427 22 600 550 660 8-24 6 315L 2 315 45 845 28 1300 397 22 600 550 660 8-24 6 315L 4-8 315 45 845 28 1330 427 22 600 550 660 8-24 6 355M 2 355 52 1010 28 1500 424 25 740 680 800 8-24 6 355M 4-6 355 52 1010 28 1530 454 25 740 680 800 8-24 6 355L 2 355 52 1010 28 1500 424 25 740 680 800 8-24 6 355L 4-6 355 52 1010 28 1530 454 25 740 680 800 8-24 6 11

Dimension drawing, B14-B34 TAC- C Pole A AA AB AC B BB C D E F G GD DB EG H HA HD K L LD AD 71 2-6 112 24 150 136,5 90 108 45 14 30 5 11 5 M5 12,5 71 10 195 7 255 100 120 80 2-8 125 35 165 155 100 130 50 19 40 6 15,5 6 M6 16 80 12 220 10 295 115 145 90S 2-8 140 36 180 169 100 140 56 24 50 8 20 7 M8 19 90 12 250 10 320 125 150 90L 2-8 140 36 180 169 125 165 56 24 50 8 20 7 M8 19 90 12 250 10 345 125 150 100L 2-8 160 40 205 195 140 175 63 28 60 8 24 7 M10 22 100 14 270 12 385 143 175 112M 2-8 190 45 230 217 140 180 70 28 60 8 24 7 M10 22 112 15 300 12 400 147 185 Size P M N S T C105 105 85 70 M6 2,5 C120 120 100 80 M6 3 C140 140 115 95 M8 3 C140 140 115 95 M8 3 C160 160 130 110 M8 3,5 C160 160 130 110 M8 3,5 12

Efficiency Typical efficiency values are given for part load in the table here under. Efficiency (%) 2-4 Poles 6-8 Poles 1.25 1.00 0.75 0.50 0.25 1.25 1.00 0.75 0.50 0.25 xpn xpn xpn xpn xpn xpn xpn xpn xpn xpn 97 97 97 96 92 97 97 97 95 92 96 96 96 95 91 96 96 96 94 91 95 95 95 94 90 95 95 95 93 90 94 94 94 93 89 94 94 94 92 89 93 93 93 92 88 93 93 93 91 88 92 92 92 91 87 92 92 92 90 86 91 91 91 90 86 91 91 91 89 85 89 90 90 89 85 90 90 90 88 84 88 89 89 88 84 89 89 89 87 83 87 88 88 87 83 88 88 88 86 82 86 87 87 86 82 87 87 87 84 80 86 86 86 85 80 86 86 86 83 78 83 85 86 85 79 85 85 85 82 76 82 84 85 84 78 84 84 84 81 75 81 83 84 83 76 83 83 84 80 74 80 82 83 82 74 81 82 82 78 72 79 81 82 81 73 80 81 81 77 70 77 80 81 79 71 79 80 80 76 68 76 79 80 78 69 78 79 80 75 67 75 78 79 76 67 77 78 78 74 66 74 77 78 75 65 76 77 77 73 64 73 76 77 74 63 75 76 76 72 64 72 75 76 72 61 74 75 75 71 62 71 74 75 71 60 73 74 74 70 62 70 73 74 70 59 72 73 73 69 60 69 72 73 69 57 70 72 71 67 58 68 71 72 68 56 69 71 70 66 56 67 70 71 67 54 68 70 69 65 56 Power factor values Typical power factor values for part load are given in the table above Power factor cos j 2-4 Poles 6-8 Poles 1.25 1.00 0.75 0.50 0.25 1.25 1.00 0.75 0.50 0.25 xpn xpn xpn xpn xpn xpn xpn xpn xpn xpn 0.92 0.92 0.90 0.84 0.68 0.92 0.92 0.90 0.84 0.68 0.91 0.91 0.89 0.83 0.66 0.91 0.91 0.89 0.83 0.66 0.90 0.90 0.88 0.82 0.64 0.90 0.90 0.88 0.82 0.64 0.89 0.89 0.87 0.81 0.62 0.89 0.89 0.87 0.81 0.62 0.88 0.88 0.86 0.80 0.60 0.88 0.88 0.86 0.80 0.60 0.88 0.87 0.84 0.76 0.58 0.88 0.87 0.84 0.76 0.58 0.87 0.86 0.82 0.73 0.58 0.87 0.86 0.82 0.73 0.56 0.86 0.85 0.81 0.72 0.54 0.86 0.85 0.81 0.72 0.54 0.85 0.84 0.80 0.71 0.52 0.85 0.84 0.80 0.71 0.52 0.84 0.83 0.78 0.70 0.50 0.84 0.83 0.78 0.70 0.50 0.84 0.82 0.76 0.66 0.46 0.84 0.82 0.76 0.66 0.46 0.84 0.81 0.74 0.63 0.43 0.84 0.81 0.74 0.63 0.43 0.83 0.80 0.73 0.60 0.40 0.83 0.80 0.73 0.60 0.40 0.82 0.79 0.72 0.59 0.38 0.82 0.79 0.72 0.59 0.38 0.82 0.78 0.71 0.58 0.36 0.82 0.78 0.71 0.58 0.36 0.81 0.77 0.69 0.55 0.36 0.81 0.77 0.69 0.55 0.36 0.81 0.76 0.68 0.54 0.34 0.81 0.76 0.68 0.54 0.34 0.80 0.75 0.67 0.53 0.34 0.80 0.75 0.67 0.53 0.34 0.79 0.74 0.66 0.52 0.32 0.79 0.74 0.66 0.52 0.32 0.78 0.73 0.65 0.51 0.32 0.78 0.73 0.65 0.51 0.32 0.78 0.72 0.62 0.48 0.30 0.78 0.72 0.62 0.48 0.30 0.78 0.71 0.61 0.47 0.30 0.78 0.71 0.61 0.47 0.30 0.77 0.70 0.60 0.46 0.30 0.77 0.70 0.60 0.46 0.30 13

Options Options Motor size 71 90 112 160 200 80 100 132 180 355 Balancing Balancing to grade B (IEC60034-14) M M M M M Bearings and lubrication Roller bearing at D-en M M Cold resistant grease M M M M M Heat resistant grease M M M M M Regreasable bearings NA NA NA M(160-250) S(280-355) 2RS bearing at both ends S S S S (160-250) SPM nipples NA NA R M M Agressive environment Stainless steel/acid proof bolts M M M M M Reinforced tropicalisation M M M M M Terminal box Terminal box right or left hand side view from D-end P P P P P Cooling system Unidirectional fan, clockwise seen from D-end R R R R R Unidirectional fan, counter clockwise seen from D-end R R R R R Aluminium fan R R R R R Cooling method IC418(without fan) R R R R R Separate motor cooling fan (fan axial, N-end) M M M M M Drain holes Modified drain hole position (for specified IM xxxx) M M M M M Drain holes with plugs M M M M M Earthing bolt External earthing bolt M M M M M Mounting arrangements IM2101 foot/flange mounted, IEC flange, from IMI1001(B34 from B3) M(71-160) NA(180-355) IM2001 foot/flange mounted, IEC flange,from IMI1001(B35 from B3) M M M M M IM3601 flange mounted, IEC flange, from IMI3001(B14 fom B5) M(71-160) NA(180-355) IM3001 flange mounted, IEC flange, from IMI3601(B5 from B14) M(71-160) NA(180-355) Paint Special paint colour, standard grade M M M M M Stator winding temperature sensors Bimetal detector, in stator winding M M M M M PTC-thermister, in stator winding S S S S S PT100 resistance element, in stator winding M M M M M Shaft & rotor One or two special shaft extensions, std shaft material R(71-250) P(280-355) Protection Protective roof, vertical motor, shaft down M M M M M IPW55 NA P(90-250) NA(280-355) Degree of protection IP56 R R R R R Heating element Heating element, 200-240V M M M M M Insulation system Winding insulation class H R R R R R Special winding insulation for frequency converter supply R R R R R 14

TAC-C cast iron motors basic design Motor size 71 80 90 100 112 132 160 Stator Material Cast iron HT150GB/T9439 Paint colour Blue, Munsell 8B 4,5/3,25/NCS 4822 B05G Paint thickness Two-pack 821 Acid Polyurethane Enamel, thickness >60 um Bearing Material Cast iron HT150 GB/T9439 end Paint colour Blue, Munsell 8B 4,5/3,25/NCS 4822 B05G shields Paint thickness Two-pack 821 Acid Polyurethane Enamel, thickness >60 um D-end 2 pole 6202 6204 6205 6206 6206 6208 6309 Bearings 4 to 8 pole 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 N-end 2 pole 6202 6204 6205 6206 6206 6208 6209 4 to 8 pole 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 2RSC3 Axially-locked bearings Spring ring As standard, locked at D-end Lubrication Greased for life Rating plate Material Stainless steel Terminal box Frame material Cast iron HT 150 GB/T9439 Cover material Cast iron HT 150 GB/T9439 Connections Cable entries 2-M16X1,5 2-M25X1,5 2-M25X1,5 2-M25X1,5 2-M32X1,5 2-M32X1,5 2-M40X1,5 1-M12x1,5 1-M12x1,5 1-M12x1,5 1-M16x1,5 1-M16x1,5 1-M16x1,5 1-M16x1,5 Terminals 6 terminals for connection Fan Material Reinforced glass fiber Fan cover Material Steel Paint colour Blue, Munsell 8B 4,5/3,25/NCS 4822 B05G Paint thickness Two-pack 821 Acid Polyurethane Enamel, thickness >60 um Stator winding Material Copper Insulation insulation class F Winding protection On request Rotor winding Material Pressure die-cast aluminium Balancing method Half key balancing as standard Key ways Open key way Enclosure IP 55 Cooling method IC 411 15

TAC-C cast iron motors basic design Motor size 180 200 225 250 280 315 355 Material Cast iron HT 150 GB/T9439 Cast iron HT200 GB/T9439 except vertical-mounted Paint colour Blue, Munsell 8B 4,5/3,25 NCS 4822 B05G Paint thickness Two-pack 821 Acid Polyurethane Lacquer Enamel, thickness > 60 um End shields Material Cast iron HT 150 GB/T9439 Cast iron HT200 GB/T9439 except vertical-mounted Paint colour Blue, Munsell 8B 4,5/3,25 NCS 4822 B05G Paint thickness Two-pack 821 Acid Polyurethane Enamel thickness > 60 um Bearings D-end 2 pole 6211 2RSC3 6212 2RSC3 6312C3 6313C3 6314C3 6317C3 6319C3 4 to 8 pole 6311 2RSC3 6312 2RSC3 6313C3 6314C3 6317C3 N319 N322 N-end 2 pole 6211 6212 6312C3 6313C3 6314C3 6317C3 6319C3 4 to 8 pole 2RSC3 2RSC3 6312C3 6313C3 6314C3 6319C3 6322C3 Axially-locked Inner bearing cover bearing As standard Locked at ND-end Lubrication Greased for life or regreasable Regreasable bearings Rating Material Stainless steel Terminal box Frame material Cast iron HT 150 GB/T9439 Cast iron HT200 GB/T9439 Cover material Cast iron HT 150 GB/T9439 Cast iron HT200 GB/T9439 Connections Cable entries 2-M40X1,5 2-M50X1,5 2-M50X1,5 2-M63X1,5 2-M63X1,5 2-M63X1,5 2-M63x1,5 1-M16X1,5 1-M16X1,5 1-M20X1,5 1-M20X1,5 1-M20X1,5 2-M20X1,5 1-M20x1,5 Terminals 6 terminals for connection Fan Material Reinforced glass fiber Reinforced glass fiber or aluminium Fan cover Material Steel Paint colour Blue, Munsell 8B 4,5/3,25 NCS 4822 B05G Paint thickness Two-pack 821 Acid Polyurethane Lacquer Enamel thickness > 60 um Stator Winding Material Copper Insulation Insulation class F Winding protection On request 3 PTC thermistors as standard Rotor winding Material Pressure die-cast aluminium Balancing method Half key balancing as standard Key way Open key way Enclosure IP 55 Cooling method IC 411 T-T Electric reserves the righ to change the design, technical specification and dimensions without prior notice. 16

Name plate 3~ motor TAC-C 90 L2 EFF 2 N 5011018 S1 IP 55 Ins. CL F IEC 34-1 V Hz kw r/min A Cos ᵠ 230 D 50 2,2 2850 7,85 0,86 260 D 60 2,53 3440 8,21 0,85 400 Y 50 2,2 2850 4,53 0,85 Y 3~ motor TAC-C 250 M4 EFF 2 N 5011019 S1 IP 55 Ins. CL F IEC 34-1 V Hz kw r/min A Cos ᵠ 400 D 50 5,5 1480 98,5 0,86 460 D 60 5,3 1779 99,70 0,89 690 Y 50 5,05 1480 57,10 0,87 Y Mounting arrangements (H71-355) (H71-160) (H71-160) (H71-160) (H71-160) (H71-160) (H71-280) (H71-355) (H71-160) (H71-355) (H71-160) (H71-160) (H71-112) (H71-112) (H71-112) (H71-112) (H71-112) (H71-112) 17

Founded over 100 years ago, T-T Electric is a world-class supplier of top-quality industrial electric motors and drives. Pioneers in the industry, we are an experienced and established manufacturer of a comprehensive and cost-effective range of highly reliable drive products. They are used around the world in the toughest of application environments and in all industrial segments. Driven by customer demand, T-T Electric is continually researching product excellence and manufacturing process perfection. The flexible product design ensures easy adaptations to customer requirements. This, combined with unequalled short delivery times, make T-T Electric a reference within industry. Our extensive support services include diagnostics and maintenance on site as well as full overhaul in our own repair facilities. T-T Electric is committed to a working partnership with our customers. For mutual benefit, we focus on complete and innovative solutions together. Denmark T-T Electric Svendborgvej 83 5260 Odense S Tel: +45 63 13 06 30 E-mail: sales@t-telectric.dk UK T-T Electric Unit 7A Waterloo Park Upper Brook Street STOCKPORT SK1 3BP Tel: +44 (0) 161 480 0037 Fax:+44 (0) 161 476 4390 E-mail: john.legg@t-telectric.com Germany T-T Electric Helgolandstrasse 67 D-70439 Stuttgart Tel: +49 (0) 711 38 04 410 Fax: +49 (0) 711 38 04 411 E-mail: info@t-telectric.de Sweden Thrige Electric Lefflersgatan 1 PO Box 1641 S-75146 Uppsala Tel: +46 (0) 18 657010 Fax: +46 (0) 18 107478 E-mail: info@thrige-electric.se France T-T Electric 22 rue du 8 mai 1945 F-95340 PERSAN Tel: +33 (0) 1 30 28 62 01 Fax: +33 (0) 1 34 70 21 79 E-mail: info@t-telectric.fr t-telectric.com