WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

Similar documents
WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

WPS60/S EP Series. Features:

WPS350/S EP Series. Features:

WPS250/S EP Series. Features:

WPS20/S EP Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Super Silent, Superior Life!

Better Soundproof, Better Life!

GMS350C/S EC Series. Features:

EP series WPS800S rpm,3-phase/5-wiring

GMS100C/S EC Series. Features:

GMS200C/S EC Series. Features:

EP series WPS100S-AU rpm,3-phase/5-wiring

Super Silent, Superior Life!

EP series WPS150BS-AU rpm,3-phase/5-wiring

Super Silent, Superior Life!

EC series GMS30CS-AU 50

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

130 KW / 165 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

CGT Stamford UCI 274 E1

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

640 KW / 800 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

55 KW / 70 KVA POWERED by

Technical specification

Diesel Generator Sets Power by UK Perkins

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

Model NA 2 L

TPD2250H6.3 TECHNICAL DATA

Diesel generator set QSK23 series engine

20 KW / 25 KVA LIQUID COOLED POWERED by

Model MP150 W W

204 KW / 254 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

70 KW / 90 KVA POWERED by

Rating Definitions and Conditions

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

30 KW / 40 KVA POWERED by

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

Diesel generator set QSK23 series engine

60 KW / 75 KVA POWERED by

DIESEL GENERATOR SET MTU 18V2000 DS1400

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

700 KVA / 550 KW POWERED by

Rating Definitions and Conditions

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Rating Definitions and Conditions

64 KW / 80 KVA POWERED by

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

DIESEL GENERATOR DATA SHEET

DIESEL GENERATOR SET MTU 16V2000 DS1000

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENERATOR SET MTU 16V2000 DS1100

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

WPS1000 / WPS1000S. Features: EP Series

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

PGKT / / / / / / / / / / / /

1000 KW / 1250 KVA POWERED by

28 KW / 28 KVA POWERED by

1 / Genset general description

WPS1250 / WPS1250S. Features: EP Series

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

600 KW / 750 KVA POWERED by

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

500 KW / 625 KVA POWERED by

18 KW / 18 KVA POWERED by

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DIESEL GENERATOR SET MTU 16V2000 DS KVA

Rating Definitions and Conditions

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

SIVASA Doosan Series. SD250 Technical Data

RENTAL DIESEL GENERATOR SET

APD-ULJ250. Standby Power

16 KW / 20 KVA POWERED by

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

2000 KW / 2500 KVA POWERED by

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

Transcription:

广泛应用于通讯 工业 租赁 Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域 Outdoor Projects, Mining, Minitary, etc. EP Series Generator Set Specification NO: DT1222012S- 02 c 2010 Power Link Machine (Shanghai) Co., Ltd. Super Quiet, Superior Life! Page - 1 - of 5

3-Phase, 50Hz@1500RPM Prime Power Standby Power Voltage kw kva Amps 380 109.6 137 208.2 400 109.6 137 197.7 415 109.6 137 190.6 440 109.6 137 179.8 380 121.8 152.2 231.3 400 121.8 152.2 219.7 415 121.8 152.2 211.8 440 121.8 152.2 199.7 Noise Level at 7 meters (dba) 69 Notes: 1) Ambient reference conditions: 1,000 mbar, 27, 30% relative humidity; 2) Standby Power: the maximum power available under varying loads. Only for standby and emergency use. No overload is permissible. Prime Power: the maximum power available under varying loads for continuous operation. A 10% overload is permissible for 1 hour every 12 hours. Features Excellent cooling system, reliable operation under harshest conditions. PLC-5220 control panel with AMF function. With sound attenuated enclosures available with high protection against water and dust. Designed with safety in mind earth leakage protection. Leroy Somer Alternator, IP 23 class H insulation. Benefits Function stability credibility, service convenience. Low operating cost results in optimal economy. Gets the job done wherever you are. Ease of installation, operation, and maintenance. Performance Specification and Craftwork Performance Specification Telephone Interference, Electromagnetism Efficiency of Rated Power 96.3% TIF 50 Time needed from start-up to full load (inductive) 125 seconds THF 2% Time needed from start-up to 50% load 8 seconds Radio interference in compliance with BS800 and VED (inductive) allowed LEVELS G and N. 1.1 times overload operation time (hour) 1 2.0 time overload operation time (minute) 1 Voltage Regulation, steady state ±1% Voltage Regulation, transient state 20%-15% Voltage Settle Time Voltage Fluctuation Ratio 0.5% Frequency Regulation, steady state Frequency Regulation, transient state ±5% Frequency Settle Time Frequency Fluctuation Ratio 0.5% Recovery Time 5 seconds ±0.5% adjustable 5 seconds 0.5 seconds Craftwork Steel base frame with AV mounting standard 8h fuel tank with flexible rubber fuel tube, fuel level indicator and drainage Overall sprayed powder coating Whole set documents, including Installation Manual, Operation Manual, Spare Parts Catalog, Circuit Diagram Criterion ISO3046, ISO8528, BS4999, BS5514, BS5000PT99 AS1359, IEC34 UTE5100, VDE0530 ISO9001:2000 Page - 2 - of 5

Engine Specification Alternator Specification Brand Perkins (UK) Brand Leroy Somer Model 1006TAG Model LSA44.2M95 No. of Cylinders and Cycle 6L, 4 Stroke Rated Output (kva) 150 Induction TCA Ratedcurrent ( A) 197.7 Compression Ratio 18.3:1 Exciter Brushless Displacement (L) 6 THF(BS EN60034-1) <2% Bore x Stroke(mm) 105 x 127 Bearing number Single Ambient Temp ( ) 25 Windings 100% Copper Continuous Rated Power (kw) 128.4 Connection Type Star Connection Speed (rev/min) 1500 Insulation Class Class H Cooling Air Flow (L/min) 140 Winding Pitch 2/3 Air Intake Flow (m³/min) 8.38 Amortisseur Winding Full Exhaust Gas Flow (m³/min) 24.14 A.V.R. Model R438 Exhaust Temp ( ) 571 Voltage Regulation (no load- full load) ± 0.5% Starting E Underspeed Protection Standard Battery Voltage/Capacity 12VDC/200A/200 Protection IP23 Fuel Consumption (L/h) 110% load Phase Sequence A(U), B(V), C(W) 100% load 33.3 TIF (NEMA MG 1-22) <50 75% load 25.2 Excitation Self-excited, PMG optional 50% load 16.9 AmbientTemp ( ) 40 Governor Type Mechanical Stator Rated Temp ( ) 125 Cooling Fuel Radiator Type of Injection Direct Face Area (m 2 ) 0.401 Fuel injection pump Rotary / Stanadyne DB4 Rows and Materials 3 Brass Fuel atomizer Bosch / RSU / 4 hole Width of Matrix (mm) 637 Nozzle pressure (MPa) Height of Matrix (mm) 630 Fuel Lift Pump opening Pressure Cap Setting (kpa) 50 120-150 122.4 24.7 Pressure (kpa) 30 Fan Governor Type Mechanical / Electronic Diameter (mm) 635 Drive Ratio 1.25: 1 Lubricating Number of Blades 10 Lubricating Oil Capacity Material Composite Total (L) 19 Type - Minimum (L) 16 Coolant Lubricating Oil Pressure Total With Radiator (L) 37.22 Relief Valve Open(kPa) 345-414 Normal temperature Capacity Without Radiator (L) 12.7 105-125 ( ) Exhaust Electrical Max. Back Pressure (kpa) TBA Alternator (A/V) 55/12(or 24) Exhaust Outlet Size (mm) 78 Starting Motor (V) 12/24 Page - 3 - of 5

Control PLC-702 DSE-702 key manual start module is a manual engine control module designed to control the engine via a key switch and push buttons on the front panel. The module is used to start and stop the engine and indicate fault conditions, automatically shutting down the engine and giving a true first up fault condition of an engine failure. Standard Control Function Manual Engine Control Module Low Oil Pressure High Engine Temperature Auxiliary Shutdown Overspeed Protection Protection hold-off timer Charge Failure warning PLC-5220 DSE-5220 control pannel is applied Microprocessor control, with high stability and credibility Mains supply and generator operation monitoring Indicating operation status and fault conditions Multiple protections; multiple parameters display, like pressure, temp. Manual and automatic work mode selectable Real time clock for time and date display, overall runtime display, 99 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed Communication with PC via RS485 OR RS232 interface, using MODBUS protocol. Dimension and Weight Length Width Height, (mm) Weight (kg) 3140 1200 1800 2240 Page - 4 - of 5

Optional Engine Alternator Generator Set Fuel Canopy Coolant heater Space heater AVR PMG with regulator Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Trailer Lubricating Exhaust Cooling Control Panel Voltages Oil with the machine Protection board from hotness Low frequency silencer Front heat protection 50 radiator Coolant (-30 O C) Remote control panel Automatic paralleling control panel Automatic Transfer Switch (ATS) 415/240V 400/230V 380/220V 220/127V 200-115V Air Switch Paralleling Control ATS Mobile Trailer Power Link Machine (Shanghai) Co., Ltd. No. 576, Guanghua Road, Songjiang Science & Technology Park, Shanghai, China Tel: 086-21- 57858485 Fax: 086-21- 57858750 E-mail: info@powerlinkgenset.com Local Distributor Specification may change without prior notice. For more info., please contact Power Link or your local distributors. Page - 5 - of 5