VARIABLE & FIXED SPEED INDUSTRIAL PERISTALTIC PUMPS OPERATING MANUAL

Similar documents
VARIABLE & FIXED SPEED PERISTALTIC PUMPS OPERATING MANUAL

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

MITYFLEX PERISTALTIC PUMPS

Illumifalls Patio Pond

TPAK Series COOLANT PUMP

Model 1100 Turbine Flow Meter Repair Kits

TPHK Series Immersible Pump

LAL SERIES LED LUMINAIRE

SUBMERSIBLE MINI-PUMP

Owner s Manual Hydro-X Xtreme Xtractor

TPHK Series Immersible Pump

VSP SERIES Installation, Operation and Maintenance Manual

Operator s Safety and Service Manual

MityFlex Peristaltic Pump

Submersible Waterfall Pump 1200 Gallons Per Hour

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

GARDEN HOSE UTILITY PUMP

SUBMERSIBLE SUMP PUMPS

Premium Pond Pump 330 Gallons Per Hour

Submersible Pond Pump with UV 800 Gallons Per Hour

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

SUBMERSIBLE POND PUMP

Container Fountain Kit with LED Light

Premium Waterfall Pump 1200 Gallons Per Hour

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Natural Fiber Planter Fountain

25 GALLON PORTABLE OIL LIFT

Illumifalls Kit REMINDER CALL BEFORE RETURNING TO STORE.

Quick Start Guide Expansion Battery Pack UPS-OLEBPR-1 UPS-OLEBPR-2

Pressurized oil drain for collection of used lubricants and anti-freeze.

Duplex Booster System Instruction Manual

Low-Water Auto Shutoff Pump with Light 300 Gallons Per Hour

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

MOONRING 1.5 MOONRING 3

Instruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Model 1100 Turbine Flow Meter

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

Operator s Safety and Service Manual

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

24G621 Agitator Speed Controller Accessory

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

MIL-24/2600Q MIL-24/3200DQ

Owner s Manual Hydro-X Xtreme Xtractor

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

UV PROCESS SUPPLY, INC. CON-TROL-CURE

HR-20P Pneumatically Controlled Pressure Regulator

ProFlo FatBoy

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Pro Shot Grease Dispense Valve

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Installation Instructions

Peristaltic Cased Tube Pumps

OWNER S MANUAL Spa & Jetted Bathtub Pump

SUNC3000 / Item #40885

series USER MANUAL

INSTRUCTIONS PARTS LIST

Owner s Manual Drill and Light Weight Portable Utility Pumps

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

Specification Grade Contemporary Wall Mount/Technical Installation Data

Automated I.V. Stand Cat. No OPERATOR S MANUAL. Operation& Maintenance Instructions. Raising the Standard of Care!

Table of Contents. Safety... 2 Specifications... 3 Setup Parts List and Diagram Warranty Operation Maintenance

Peristaltic Pump Operating Instructions

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

ATD Gallon Pressurized Oil Drain Owner s Manual

Owner s Manual Nitrate Series Salt Based Filter System

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

DC to AC Power Inverters

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Captivate Illuminated Mirror Light

PRE-PLUMBED SEWAGE SYSTEM

DC to AC Power Inverters

Submersible Waterfall Pump 1250 Gallons Per Hour

Cleaning System. Instructions/Parts A

Split Manifold Kits. Installation Parts List C. Converts Husky 307 Diaphragm Pump to dual fluid inlet or outlet

INSTRUCTION BOOK FOR. Dual Masking Electrol

LEV/Wn Building A Connected World

The Power of Reliability INSTRUCTION MANUAL

Innovatech User Manual. Predator 2400 T H E S U R F A C E P R E P A R A T I O N S P E C I A L I S T S

Transcription:

PERISTALTIC PUMPS Industrial Series VARIABLE & FIXED SPEED INDUSTRIAL PERISTALTIC PUMPS OPERATING MANUAL MODELS: VSP/FSP SERIES PUMPS

VSP/FSP SERIES PUMPS TABLE OF CONTENTS PAGES SAFETY, CAUTIONS AND WARNINGS 2-3 INSTALLATION / VSP AND FSP CONTROLS AND CONNECTORS 4 OPERATION 5 VSP AND FSP SERIES PUMP SPECIFICATIONS 6 TUBING INSTALLATION OPTION / FSP AND VSP SERIES FUSE REPLACEMENT PROCEDURE 7 TROUBLESHOOTING 8 REPLACEMENT PARTS / VSP & FSP SERIES PUMP FLOW SPECIFICATIONS 9 LIMITED WARRANTY 10 RETURN AND REPAIR 11 P OT E NTIA L R ISK O F E LE C T R IC SH O C K! DO N O T u s e DC mot or p ump wi t h a d amaged or al t ered p ower cord or p o w e r s u p p l y. C ont act t he f act ory or an aut hori z ed servi ce f aci lity for re p a i r. Di s c o n n e c t p ower cord b ef ore movi ng or d i sp osi ng of p ump. C A U T I O N Thi s P ump H as Been Eval uat ed wi t h Wat er O nl y. WA R N I N G - Ri sk of el ect ri c shock Thi s p ump i s sup p l i ed wi t h a g ro u n d i n g cond uct or and ground i ng- t yp e at t achment p l ug. To reduce the ri s k o f e l e ct ri c shock, b e cert ai n t hat i t i s connect ed onl y t o a proper ly g ro u n d e d, ground i ng- t yp e recep t acl e. B e f o re i n s tal l i ng or servi ci ng t he p ump, read t he p ump manual for all safety information and complete instructions. Installation and Product must adhere t o a l l re g u l at ory and comp l i ance cod es ap p l i cab l e t o t he area. 2

SAFETY, CAUTIONS AND WARNINGS CAUTIONS : When changing flow direction, allow the pump to come to a complete stop before starting again. Failure to doso could cause permanent damage to the motor. PRÉCAUTIONS : Lorsque vous changez la direction du débit, laissez la pompe arrêtez-vous complètement avant de recommencer. Échec à faire Cela pourrait causer des dommages permanents au moteur. Replace the fuse only with one of the same types and rating. The fuse rating and type are stated on the rear panel. Remplacez le fusible uniquement par l un des mêmes types et du même calibre. Le type et le type de fusible sont indiqués sur le panneau arrière. CAUTION: This Pump Has Been Evaluated for Use With Water Only. ATTENTION: cette pompe a été évaluée pour une utilisation avec de l eau uniquement. CAUTION : To reduce risk of electric shock, pull plug before servicing this pump. ATTENTION : Pour réduire le risque d électrocution, débranchez la prise avant de réparer cette pompe. WARNING : To Reduce Risk Of Electric Shock, Connect Only To A Properly Grounded, Grounding-Type Receptacle. AVERTISSEMENT : Pour réduire le risque d électrocution, connectez uniquement à une prise correctement mise à la terre. WARNING : Risk Of Electric Shock This Pump Has Not Been Investigated For Use In Swimming Pool Or Marine Areas. AVERTISSEMENT : Risque de choc électrique - Cette pompe n a pas été étudiée pour une utilisation en piscine ou en zone marine. NOTICE : Every precaution for accuracy has been taken in the preparation of this manual, however, ANKO PRODUCTS, INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in this manual. 3

VSP/FSP SERIES PUMPS INSTALLATION Voltage and frequency of power supply must be the same as shown on unit specification label. The AC power must be connected to a Grounded Power Outlet (Grounded-Fault Circuit Interrupter GFCI). DO NOT run operate pump on an un-grounded circuit. WIRING CONNECTIONS: All wiring and electrical connections must comply with local and national electrical codes. Enclosure should be either placed on a dry flat surface or mount enclosure to wall using wall mounting hardware provided. The ambient temperature should not exceed 35 C. The ambient air temperature should not exceed 104 F (40 C) and adequate air flow should be provided for. Tubing should be clean and routed so that bend radii are at a minimum four (4) times the tube diameter. Use a tube size of appropriate diameter for the flow rate and viscosity required. CAUTION: Motor life will be drastically reduced if left in the stalled position for extended periods. VSP AND FSP CONTROLS AND CONNECTORS 5.82" 4.77" 4.34" 5.82" 4.77" 4.34" 5.23" 5.23".20 4x FOR #10 SCREW.20 4x FOR #10 SCREW 5.79" 5.49" SPEED CONTROL 5.22" 3.52" 5.79" 5.49" ON/OFF SPEED SWITCH CONTROL 5.22" 3.52" VSP CASED PUMP VSP CASED PUMP ON/OFF SWITCH IEC POWER RECEPTACLE ALL MODELS IEC POWER RECEPTACLE ALL MODELS 4.77" 5.82" 4.34" 5.23".20 4x FOR #10 SCREW ON/OFF SWITCH 5.49" 5.22" 3.52" 5.79" FPS CASED PUMP RUBBER FEET 4x ALL MODELS IEC POWER RECEPTACLE ALL MODELS 4

OPERATION Before Inserting Tube: WARNINGS: Tubing breakage may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. Be sure the Pump System is off before removing or installing tubing. Fingers or loose clothing could be caught in the pump mechanism Tube Inspection: Tubing should be inspected periodically for tears, cracks, cuts, abrasions, inability to pull a vacuum, reduction or loss of flow. Tubing life may be extended by periodically repositioning the occluded tubing Turning Pump On: For VS Model, make sure the speed is set to the minimum setting. Push UP on the ON/OFF switch to turn the power ON and run pump clockwise. On VS Model, turn knob clockwise to increase the speed of the pump. The higher the percentage setting, the faster the speed of the pump. Push DOWN on the ON/OFF switch to turn the power OFF. The Laboratory Drive Units (VS and FS) are self-priming. Verify the suction side tubing is submerged into medium being pump. Prime the tubing for at least 5 minutes. 15 minutes for stable flow. 5

VSP/FSP SERIES PUMPS VSP & FSP SERIES PUMP SPECIFICATIONS Model Series VSP FSP Control Type Variable speed - Analog Fixed speed - Analog Pump Head Flow Rate Tube Bore/IDs Accepted-Metric 810 Series Varies by model & tube size 3.2mm, 4.8mm, 6.4mm Tube Bore/IDs Accepted-Fraction 1/8, 3/16, 1/4 Tube Wall Thickness Accepted-Metric 1.6mm, 2.4mm Tube Wall Thickness Accepted-Fraction 1/16, 3/32 Number of Tubing Channels 1 AC Power - VAC 100-240 AC Power - Amps 1.5 Dimensions including pump Inlet Vacuum Outlet Pressure Compliance (US and Canada) Compliance (Europe and CE Mark) 6.2 W X 5.8 H X 4.3 to 6.1 D 28 in Hg 25 psi (3 rollers) UL778 FCC Part 15b Class A ICES-003, Issue 6: 2016 EN 55014-1:2006/A12009/A2:2011 EN 55014-2:2015 MATERIALS OF CONSTRUCTION Model Series VSP FSP Enclosure Pump Housing Pump Cover Roller Material Polypropylene RTP199 Polycarbonate Polycarbonate Nylatron Rotor Material PM, CRS Bearings Sealed Stainless Steel 6

TUBING INSTALLATION OPTION Inspect all tubing regularly and replace if any sign of deterioration occurs. Always wear safety glasses and protect clothing when working with chemicals. Pump can run dry without damage. 810 SERIES PUMP HEAD TUBE REPLACEMENT PROCEDURE: 1. Disconnect power to the pump. 2. Disconnect the suction and discharge tubing from the pump tubing. 3. Remove the three (3) thumb screws and pump cover from pump. (Figure 1) 4. Pull tubing out of roller race. (Figure 2) 5. Using screw driver, remove one side of spring clip to unlock remove RBA from shaft. (Figure 3 & 4 ) 6. Replace tubing by position RBA rollers at the 6 and 12 O clock position and press tubing into place. (Figure 5) 7. Reassemble Pump Cover using the (3) thumb screws. (Figure 6) Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 VSP AND FSP SERIES FUSE REPLACEMENT PROCEDURE 1. Disconnect power to pump. 2. The fuse holder is located on the back of the case. 3. Pull the fuse tray out as shown in photo below. 4. Remove old fuse and replace with spare part # FU-1127-02-00 5. Slide fuse tray back in to lock. 7

VSP/FSP SERIES PUMPS TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Fluid Leaking Tube Life is Shortened Pump will not start Unit is ON but pump will not turn. Pump runs but does not meet rated flow Pump tube worn Excessive back pressure Tube connections are not tight Roller bracket assembly worn out Check tubing is compatible with roller size. Tubing should be snug, but not tight against the rollers. Fluid is not compatible with tubing Check for blown fuse at incoming voltage If the unit is plugged into a GFCI protected circuit Outlet is not powered IEC plug has a loose connection Gearbox assembly worn Check tubing is compatible with roller size. Tubing should be snug, but not tight against the rollers. Internal / External Switch is in the wrong position. Tubing is worn Wrong roller assembly/ tube thickness combinations Fluid viscosity is too high Pumping height is too large Replace tubing Ensure system pressure does not exceed pressure rating Ensure tubing connections are properly connected Replace roller bracket assembly Very proper Roller Bracket Assembly for tube wall thickness. Check fluid-to-tube compatibility Replace Fuse if blown Verify that the circuit has not been tripped or reset the circuit Verify that the unit is plugged into a functioning outlet. Verify that the power cord is firmly attached to IEC receptacle. Replace unit Very proper Roller Bracket Assembly for tube wall thickness. Change switch position. Replace tubing Use correct roller assembly/ tube thickness combinations Lower viscosity Reduce pumping height 8

REPLACEMENT PARTS & PUMP TUBING VSP AND FSP SERIES PUMP FLOW SPECIFICATIONS Tubing Sizing Specifications (Flow rates in ml/min) Tubing Bore 6.4 mm (1/4 ) 4.8 mm (3/16 ) 3.2 mm (1/8 ) Flow Rate ml/min Max min Max min Max min VSP-1200 1180.0 47.0 719.8 28.7 318.6 12.7 VSP-200 221.0 12.0 134.8 7.3 59.7 3.2 FSP-1100 1180.0 1180.0 719.8 719.8 318.6 318.6 FSP-350 365.0 365.0 222.7 222.7 98.6 98.6 FSP-200 221.0 221.0 134.8 134.8 59.7 59.7 FSP-50 50.0 50.0 30.5 30.5 13.5 13.5 Flow rates determined under the following conditions: 2 rollers, 0 PSI pumping water at ambient temperature. Actual performance varies depending on tubing formulation. Values shown are for firm tubing. All flows nominal. The information provided is not intended for specific application purposes. Anko reserves the right to make changes at any time without prior notice. 9

VSP/FSP SERIES PUMPS LIMITED WARRANTY For cased peristaltic metering pumps manufactured after April 16thst, 2018, Anko Products, Inc, ( ANKO ) warrants, subject to the conditions and exceptions herein, to replace or repair free of charge, any of its products which fail within three years of the date of manufacture. Any failure must be a result of a defect in material workmanship and not as a result of normal operation as described in the product user manual. This warranty is limited to repairing or replacing any device or part of any device which is returned, transportation prepaid, to the factory and is proven to be defective upon our examination. The warranty shall not apply to repairs required for normal wear and tear, lack of reasonable and proper maintenance, chemical attack, electrical surge or products that have been misused in our sole judgement. All consumable items such as tubing, and pump head rollers are excluded. ANKO disclaims all liability for any loss, damage or expense directly or indirectly related to or arising from the use of its products, including damage to other products, machinery or property. ANKO shall not be liable for any consequential damages including, without limitation, loss of profits, loss of product or loss of production. This warranty does not obligate ANKO to bear any costs of removal, installation, transportation or other charges which may arise in connection with a warranty claim. ANKO makes no warranties, either express or implied, other than those stated above. No representative has authority to change or modify this warranty in any respect. Jurisdiction and venue for enforcement of this warranty may be brought only in the State of Florida. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 10

RETURN AND REPAIR WARRANTY RETURNS: To return merchandise call ANKO PRODUCTS, at 800-683-2378 for a Return Material Authorization ( RMA ), then, if applicable, Buyer may return the defective Products to ANKO PRODUCTS with all costs prepaid by Buyer. Replacement parts may be new or refurbished, at the election of ANKO PRODUCTS. ANKO PRODUCTS will incur shipping costs for warranty products shipped from our factory. All replaced parts shall become the property of ANKO PRODUCTS. No repair or replacement will extend the original warranty period. FOR YOUR RECORDS: Model Date of Installation Notes 11