LED Linear Luminaire Series EXLUX 6402

Similar documents
Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight LED Series 6525

Floodlight LED Series 6525

Floodlight LED Series 6125

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Compact Sheet-Steel Light Fittings Series 6114/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED

Tubular Light Fitting with LED Series 6036

7 Lighting Technology

Compact Sheet-Steel Light Fittings Series 6114

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet-Steel Light Fittings Series 6014 / 6414

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Floodlight Series 6521/4

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire for Fluorescent Lamps

Plug and Socket Devices SolConeX 16 A Series 8570

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight Series 6121

Sheet Steel Emergency Light Fitting Series 6018

7 Lighting Technology

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

7 Lighting Technology

Terminal Boxes Series 8125

Load disconnect switch Series 8146/5-V11

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

7 Lighting Technology

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Ex UPS standard Series 8265

Terminal Boxes Series 8125

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Position Switches Series 8074/2

Linear fittings EVNL LED fitting - zones 2, & 22

Position Switches Series 8060/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Load and Motor Switches, Load-Break Switches Series 8544

Linear fittings EVDL LED fitting - zones 21, & 22

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Position Switches Series 8070/2

Control switch/load disconnect switch Series 8008

Tank Inspection Lights Series 6122

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Control Buttons / Switches for Panel Mounting Series 8003

Safety Switches Series 8537

Load and Motor Switches, Load-Break Switches Series 8549

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

EX-REPAIR AND MAINTENANCE RECEPTACLES

Battery Boxes Series 8316

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Load and Motor Switches, Load-Break Switches Series 8544

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Control Buttons Series 8082

Control Device System NEC Series ConSig 8040

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Operating Instructions

Pendant Light Fitting IEC

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

10 Load and Motor Switchgear

Linear fluorescent luminaire LED V-CG-S

I Ex-safety switches I

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

EXEL-L. Detail of the internal side. Transparent polycarbonate

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

7 Lighting Technology

Metal Position Switch Series 8074

Linear fittings EVN Fluorescent fitting - zones 2 & 22

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Operating Instructions

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

International approvals.

EX-RECESSED CEILING LIGHT FITTINGS

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

HTSB system System overview

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Transcription:

> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened (option) www.stahl.de 16745E00 The light fittings are suitable for standard lighting and with connection to group or central battery systems for emergency lighting. ATEX / IECEx / GOST Zone 0 1 2 20 21 22 For use in: x x Explosion Protection Global (IECEx) Gas and dust IECEx PTB 13.0049 Ex nr op is IIC T6 Gc or Ex nrc op is IIC T6 Ex tc IIIC T80 C Dc or Ex tc IIIC T80 C Europe (ATEX) Gas and dust PTB 13 ATEX 2020 E II 3 G Ex nr op is IIC T6 Gc or Ex nrc op is IIC T6 Certifications and certificates Certificates E II 3 D Ex tc IIIC T80 C Dc or Ex tc IIIC T80 C IECEx, ATEX WebCode 6402A Lighting /1

Selection Table Version Length Power consumption mm Diffusor Order number Weight EXLUX 6402 700 28 W without 6402/1142-0200-251 4.410 Order Number Supplement with 6402/1182-0200-251 4.460 1310 52 W without 6402/1244-0200-251 6.532 with 6402/1284-0200-251 6.632 Connection 5-wire cage clamp terminal, without through wiring 6402/1...-020.-.51 5-wire cage clamp terminal, with through wiring 6402/1...-520.-.51 5-wire screw terminal, without through wiring 6402/1...-020.-.81 5-wire screw terminal, with through wiring 6402/1...-520.-.81 Switching off Standard: without 6402/1...-...0-..1 Special: with switch 8080, 2-pole 6402/1...-...1-..1 Cable glands 1 x M25 x 1.5 cable gland and 6402/1...-.20.-2.1 2 x M25 x 1.5 stopping plugs kg 3 x M20 with metal plate without cable glands or stopping plugs 6402/1...-.20.-1.1 NOTE The light fittings are delivered without mounting material. These accessories must be ordered separately! Technical Data Electrical data Ballast Inrush current AC: 220 V... V ± 10 %; 50... 60 Hz DC: 196 V... V ± 10 % I peak = 53 A; Δt = 200ms max. light fittings per circuit breaker: Power factor ) 0.93 Disconnection of the light When opening the luminaire Switch with safety lock (optional); when opening the central lock all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are positive opening, they can only be switched on again when the luminaire trough and the central locking system are closed. Luminous characteristics Colour temperature 5700 K Colour rendering Ra ) 70 Luminous flux Typ 10 A 16 A 20 A 25 A B 8 13 16 20 C 13 22 27 34 without diffusor 6402/11.2-...-..1 (28 W) 6402/12.4-...-..1 (52 W) at T a = 25 C at T a = 25 C luminous flux 3150 lm 5800 lm Luminaire efficacy 113 lm/w 111 lm/w Light output ratio 92 % 92 % with diffusor luminous flux 2760 lm 5040 lm Luminaire efficacy 99 lm/w 97 lm/w Light output ratio 81 % 82 % Luminous flux decrease at T a = 55 C min. 85% of the nominal value. /2 Lighting

Technical Data Ambient conditions Operating temperature -30 C... +55 C range Storage -30 C... +75 C Service life Service life Mechanical data Degree of protection IP66 / IP67 (IEC 60598) Protection class I(with internal PE connection) Impact strength (IK code) IK10 (IEC 62262) Material Enclosure Material Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Gasket Silicone foam gasket in the lamp cover Lamp cover Polycarbonate Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands T a ( 25 C T a ( 45 C T a ( 55 C L 70B 10C 10 100,000 h 50,000 h 50,000 h L xb yc z At the end of the service life: Luminous flux decrease to "x" percent max. "y" percent of all light fittings fall below "x" max. "z" percent of all light fittings break down completely Plastic: (Standard) Metal: Special: 1 x M25 x 1.5 cable gland 8161 1 x M25 x 1.5 stopping plug 8290 1 x M20 x 1.5 cable gland 8161 with red plug (test opening for restricted breathing test) 2 x metal plates M20 x 1.5 connected by means of PE for metal cable glands Attention: cable glands must be ordered separately. max. 4 drilled holes for M20, M25, NPSM ½ max. 2 drilled holes for NPT ¾ Connection Note: Use a drilled hole as test opening for the restricted breathing test. Standard: Spring clamp terminals 5-pole: L1, L2, L3, N, PE (with through wiring) Clamping range: 1 x 0.75... 4 mm 2 (solid/finely stranded) (2 free clamping units for each pole available) Special: Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2x 0.75... 6 mm 2 (solid); 2 x 0.75... 4 mm 2 (finely and extra finely stranded) Through wiring Standard light fitting with Light fittings are equipped with internal through wiring. Ingoing and outgoing leads can be connected to the opposite sides. Terminals: see techn. data Wiring cross section: 2.5 mm 2 for max. 16 A. Optional without On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Assembly Standard light fitting 2 x M8 insert nuts in the enclosure Mounting grooves in the enclosure for use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires length 700 mm: 320... 480 mm, length 1310 mm: 670.. 930 mm) Lighting /3

Light distribution curves 16615E00 28 W without diffusor 28 W with diffusor 16616E00 16617E00 52 W without diffusor 52 W with diffusor 16618E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Lamp cover for luminaire L=700 222427 0.639 Socket key for luminaire L=1310 222428 1.149 for luminaire L=700 (resistant to aromatic substances) 256534 0.639 for luminaire L=1310 (resistant to aromatic substances) 256535 1.149 M8 / wrench size 13; to open/close the central locking kg 222430 0.210 Ring bolt 15507E00 M8, direct mounting in insert nuts, 1 pair 115736 0.120 05378E00 Pipe clamp R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 Mounting bracket 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel 1 pair Mounting clamp mounted on a mounting rail for a variable mounting distance; 1 pair 222456 0.400 Mounting rail 15585E00 for a variable mounting distance 1 pair 222826 0.300 Pole mounting sleeve 15584E00 for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.300 16985E00 Ceiling and wallmounting bracket 15586E00 1 pair 222827 2.400 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Adapter plates 1 x M20 x 1.5 1 piece 1 x M25 x 1.5 1 piece 115815 0.070 115818 0.070 05755E00 1 x NPSM 1 / 2 1 piece 1 x NPT 3 / 4 1 piece 115821 0.070 115824 0.070 2 x M20 x 1.5 1 piece 115826 0.060 2 x M25 x 1.5 1 piece 2 x NPSM 1 / 2 1 piece 115828 0.060 115829 0.060 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates Lighting /5

Accessories and Spare Parts Designation Figure Description Art. no. Weight Handheld testing instrument for gastight enclosures For testing of restricted breathing of gastight enclosures of type Ex nr 230434 kg Switch 11006E00 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 10809E00 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations b L1 L2 M25 x 1,5 L3 M25 x 1,5 h1 15440E00 Dimensions Luminaire 28 W 52 W L1 700 [27.56] 1310 [51.57] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6402 Standard luminaire Dimensional drawings for assembly parts and accessories (all dimensions in mm) - Subject to alterations 30,50 [ 1, 20 ] 12 [ 0, 47 ] 215 [ 8.46] 18,50 [ 0, 73 ] 30 [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail /6 Lighting

Dimensional drawings for assembly parts and accessories (all dimensions in mm) - Subject to alterations ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] Ring bolt fitted in insert nut of the light fitting 15782E00 15781E00 15783E00 Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail 10x15 A 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] 198 [7,80] [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Wall mounting bracket fitted in mounting rail 15780E00 Bracket for wall mounting with pipe section 03257E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7