KUDA KUDA (15000/DX-15000/SX) KUDA (22000/DX-22000/SX) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

Similar documents
BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

SC230 (AS AS05711) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS

INSTRUCTIONS FOR INSTALLATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC DECLARATION OF CONFORMITY

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Automation Swing Gate Opener

FORCE SPD 800/1500/2000

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Ditec PWR25H/35H Automation for hinged gates

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

BISON 20 OM BISON 25 OTI

Installation Manual. Swing Gate System. Leading the way...

Ditec LUXO Swing gates automation (Original instruction)

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

SLIDE NEW CONTROL BOARD

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Ditec PWR50H/HV/HR Automation for swing gates

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

BULL 424 ESA BULL 624 ESA

FITTING AND CONNECTION INSTRUCTIONS

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

SWING GATE OPENERS 24V DC GEAR MOTOR

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

TITANO 400V SLIDING GATE OPENER

FEATURES AND SPECIFICATIONS

Automatic concealed bollards 275 H600 and 275 H800 Control station

E R A I GATE AUTOMATION DIVISION

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Automatic concealed bollards 275 H600 and 275 H800 with pit

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

Sliding Gate Operator User's Manual

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

BARRY BARRIER GATE AUTOMATION

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

TECHNICAL DATA HYDRAULIC UNIT

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

Ditec CUBIC Swing gates automation

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

Sliding Gate Operator User's Manual

E R A I Gate Automation Division

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

E R A I INSTALLATION MANUAL. Gate Opener Department MERCURIO 302 F MERCURIO 502 F MERCURIO 802 F MERCURIO 501 F

Ditec DOD Industrial sectional door automations

INSTALLATION MANUAL GB

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

VER KIT. Installation Instructions TECHNICAL HELPLINE

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

ROSSO EVO User s and Installer s manual

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Porte 150 Users Manual Swing Gate Opener 24V DC

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR

Instruction Manual for the. E-SL 450 Series

E R A I Gate Openers Department

Mod: KLD6-12/35XLAS-N

INSPECTIONS AND MAINTENANCE

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

USER INSTRUCTIONS FOR SLIDING DOORS

Ditec SPRINT Swing doors drive unit

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

ARACHNE 230V 24V- 12V

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Ditec BOX Balanced up and over doors

CE DECLARATION OF MACHINE CONFORMITY

LINCE 300/400/600. User s and Intaller s manual

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

CE DECLARATION OF CONFORMITY OF MACHINES. Warnings for the installer General safety obligations

ELECTRONIC CONTROL PANEL FOR ONE 230VAC MOTOR TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

HYDRAULIC SWING GATE OPENER

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

Automation systems for swing gates hydraulic

Transcription:

KUDA KUDA 150 - (15000/DX-15000/SX) KUDA 200 - (22000/DX-22000/SX) Operatore elettromeccanico lineare ISTRUZII PER L INSTALLAZIE Electromechanical linear operator INSTRUCTIS FOR INSTALLATIS I

10 KUDA WARNINGS FOR THE USER In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using original and certified materials. The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or lacking experience and knowledge, unless appropriately instructed. Do not access the circuit board for adjustments and/or maintenance. CAUTI: IMPORTANT SAFETY INSTRUCTIS. It is important to follow these instructions in order to safeguard persons. Keep this instruction booklet

9 INTRODUCTI The KUDA operator for swing gates is an electromechanical device that transmits motion to the gate by means of a worm screw. It is locked when the motor is not running, it is necessary to install locks if fitted on blind/flush panel doors. WARNINGS FOR THE INSTALLER Before proceeding with installation, fit a magnetothermal and differential switch with a maximum capacity of 10A upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3mm. All the packaging materials must be kept out of reach of children since they are potential sources of danger. The manufacturer declines all responsibility for proper functioning of the automated device if failing to use original GIBIDI components and accessories suitable for the intended application. When installation has been completed, always carefully check proper functioning of the system and the devices used. This instruction manual addresses persons qualified for installation of live equipment, therefore, good technical knowledge is required exercised as profession in compliance with the regulations in force. Maintenance must be performed by qualified personnel. Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains. This product has been designed and constructed solely for the use indicated in this document. Any other use may cause damage to the product and be a source of danger. Verify the intended end use and take the necessary safety precautions. Use of the products for purposes different from the intended use has not been tested by the manufacturer and the operations performed are therefore on full responsibility of the installer. Mark the automated device with visible warning plates. Warn the user that children and animals must not play or stand near the gate. Adequately protect the danger points, for example, using a sensitive frame. Check proper installation of the earthing system; connect all the metal parts of doors, gates, etc. and all the system components equipped with earthing plate. Exclusively use original spare parts for any maintenance or repair. Do not make any modification to the components of the automated device unless expressly authorised by GIBIDI. Gi.Bi.Di. Srl reserves the right to change the technical data without prior notice in relation to product development. WARNING: IMPORTANT SAFETY INSTRUCTIS. It is important for the safety of persons to follow these instructions. Keep this instruction manual.

KUDA 11 TECHNICAL DATA Operator Type Supply voltage Power absorbed Current absorbed Electric motor Useful travel Max thrust/traction force Maximum leaf length Maximum leaf weight Linear velocity Operating temperature Degree of protection Frequency of use (%) Encoder ELECTRICAL EQUIPMENT KUDA 150 KUDA 200 Irreversible electromechanical with worm screw 24 Vdc 100 W (~1000 N) 4 A (~1000 N) MAX 24 Vdc 2600 rpm 360 mm 400 mm 1000 N 1500 N 2 m 2.5 m If fitted on blind/flush panel doors it is mandatory to use an electric lock 150 Kg 200 Kg 20 mm/s -20 C + 60 C IP 44 intensive Integrated into the motor Electric system setup Set up the electric system as shown in fig.1 referring to the electric system regulations and other national regulations in force. Keep the mains power connections clearly separated from the service connections (photocells, sensitive frames, control devices, etc.). The main components are: 1- Antenna; screened coaxial cable 2- Electronic control unit container 3- Electric lock; 1 mm² 2-core (2x1) cable 4- Key selector; 0,5 mm² 3-core (3x0,5) cable 5-24Vdc operators: - 1,5 mm² 2-core (2x1,5) cable power supply WHITE = + YELLOW = - for a cable length of 6 m max., over it s necessary increase the cable section. -0,5mm² 3-core (3x0,5) encoder cable. 6- Omnipolar magnetothermal and differential switch with minimum contact opening of 3 mm 220-230V/50-60Hz control unit power line: min. 1,5 mm² 3-core cable (3x1,5) (adhere to the regulations in force) 7-24V flashing light; 0,75 mm² 2-core (2x0,75) cable 8- Connector blocks 9- Photocell transmitter; 0,5 mm² 2-core (2x0,5) cable 10- Photocell receiver; 0,5 mm² 4-core (4x0,5) cable A- Opening mechanical end-stop. B- Closing mechanical end-stop. CAUTI: It is important that an omnipolar magnetothermal and differential switch with a minimum contact opening of 3 mm be fitted upstream of the control unit.

12 KUDA PRELIMINARY WARNINGS Check that the gate structure is in conformity with the regulations in force and that the gate movement is linear without friction. Preliminary checks: Check that the gate structure is sufficiently robust. In any event, the actuator must push the leaf at a reinforced point. Manually check that the leafs move without force along their entire travel. Check that the gate opening and closing end-stops A-B fig.1 have been installed. If the gate is not a new installation, check the state of wear of all the components, and repair or replace the defective or worn parts. The reliability and safety of the automated device is directly dependent on the condition of the gate structure. INSTALLATI DIMENSIS Refer to fig. 6 for possible installation dimensions. The difference between A and B must not exceed 50 mm; greater differences cause irregular gate movement (the traction/thrust force and the movement speed vary during the manoeuvre). OPERATOR INSTALLATI Preliminary checks: For proper functioning of the automated device, the existing or new gate structure must meet the following requirements: The individual leafs must have a maximum length of 2 metres (KUDA 150) or 2,5 meters (KUDA 200) The leaf structure must be robust and rigid The leafs must move smoothly and uniformly without irregular friction along their entire travel The existing hinges must be in a good condition The mechanical end-stops A-B fig.1 must be fitted Installing the operators 1 - Find the most suitable point where to fasten the front bracket of the operator and mark it. 2 - Using a spirit level mark the point on the pillar where to fasten the rear bracket. 3 - Identify the point where to fasten the rear bracket in relation to the dimensions A-B fig. 6 and in relation to fig. 3-4-5. CAUTI: Where there are big pillars or walls, a niche must be made so that the dimensions A and B are respected. 4 - Fasten the rear bracket to the pillar fig.7a. 5 - Fit the operator on the rear bracket using the pin provided fig.7b. 6 - Fasten the front bracket on the operator fig.8a. 7- Unlock the operator (see unlocking device), pull out the operator rod fully then push it inside for 20 mm. 8 - Move the leaf to closed position against the mechanical end-stop B fig.1.

13 OPERATOR INSTALLATI 9 - Fix the front bracket to the leaf with a clamp fig.8b. 10- Use a spirit level to check that the operator is perfectly level. 11 - Remove the operator from the front and rear bracket. 12 - Fasten the front bracket. 13- Unlock the operator (see unlocking device). 14 - Fit the operator on the brackets. 15 - Manually open and close the gate to its full opening and closing travel. The gate must move smoothly without friction and the lead nut must not reach the mechanical end-stop during opening or closing. If otherwise, adjust the bracket positions. It is recommended to leave at least 40-50 mm of cable free. UNLOCKING DEVICE If the gate needs to be operated manually because of a power failure or operator malfunctioning: Remove the rubber plug fig.9a-9e. Insert the release key to the release slot fig. 9a-9e. Turn the release key as shown in fig.9b-9f. Pull out the release bar and keep it pulled out fig.9c-9g. Turn the release key to its original position to fix the release bar fig.9d-9h. Move the gate manually only in the event of a power failure. INSTALLING THE ELECTRIC LOCK If you need to install an electric lock, refer to figures fig. 11 and fig. 12. 1) ELECTRIC LOCK 2) ELECTRIC LOCK FASTENING PLATE 3) BUSHING 4) END-STOP FOR BUSHING 5) SPRING LATCH 6) THROUGH CYLINDER ( REQUEST) 7) GATE FINAL CHECKS Power the system and run a complete opening and closing cycle checking that: The safety devices function properly; The gate moves smoothly; Good hold of the fastening brackets; That the power cable moves freely; The gate assembly conforms to EN 12453 and EN 12445; For further details and information on the reference standards, visit our site: www.gibidi.com

14 KUDA MAINTENANCE Periodically check the gate structure, in particular: - Check functioning of the hinges; - Check that the leafs are correctly balanced. Excessive inclination of the leafs will result in faster wear of the operator fastening brackets. Do the test by unlocking the operator and checking that the leafs do not move on their own; - Check good functioning of the safety devices; - Unlock the operator and check that there are no points of friction along the entire travel; - Check that there is no dirt or debris on the worm screw, and if so, clean and then lubricate the worm screw with lubricating grease. - Periodically check proper adjustment of the operator thrust force and the efficiency of the unlocking device for manual operation (see the relative paragraph). - The safety devices installed on the system must be checked every six months. MALFUNCTIING For any unresolved malfunction, cut the power to the system and call in a qualified technician (installer). In the period when the gate is out of service, activate the manual unlocking device to allow manual opening and

KUDA 15 The manufacturer: CE Declaration of conformity GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: ELECTROMECHANICAL GEARMOTOR KUDA 150-200 Are in conformity with the following CEE Directives: LVD Directive 2006/95/CE and subsequent amendments; EMC Directive 2004/108/CE and subsequent amendments; and that the following harmonised standards have been applied: EN60335-1, EN61000-6-1, EN61000-6-3 Moreover declares that the product must not be used until the machine in which it has been incorporated has not been declared in accordance with 2006/42/CE Directive. Date 26/05/14 The legal Representative Michele Prandi

KUDA KUDA 150 - (15000/DX-15000/SX) KUDA 200 - (22000/DX-22000/SX) Operatore elettromeccanico lineare DISEGNI E SCHEMI Electromechanical linear operator DRAWINGS AND DIAGRAMS I

2 KUDA IMPIANTO TIPO / TYPICAL INSTALLATI 91 5a 8 10 7 4 10 1 A 3 2 B 5b A 8 9 9 6 B 5a LEFT OPERATOR-MOTOR 2 OPERATORE SINISTRO-MOTORE 2 5b RIGHT OPERATOR-MOTOR 1 OPERATORE DESTRO-MOTORE 1 DIMENSII OPERATORE / OPERATOR DIMENSIS 92 93mm 170mm 46mm KUDA 150 360mm 98mm 640mm 674mm 29mm 93mm 170mm 46mm KUDA 200 400mm 98mm 765mm 799mm 29mm

KUDA 3 STAFFE / BRACKETS 93 50 35 Ø9 17 15 82 94 17mm 15mm Ø9 20 48 APERTURA VERSO L INTERNO / INWARD OPENING 91 94 Min 150mm CHIUSURA / CLOSING KUDA 150 MAX 120mm KUDA 200 MAX 150mm

4 KUDA APERTURA VERSO L ESTERNO / OUTWARD OPENING 91 95 Min 70mm APERTURA / OPENING QUOTE INSTALLATIVE / INSTALLATI DIMENSIS 91 96 B A β B A 120 KUDA150 120 130 140 150 160 170 180 190 B A 140 KUDA200 140 150 160 170 180 190 200 210 130 140 150 160 170 180 190 β>120 β=110-120 β=100-110 β=90-100 β<90 150 160 170 180 190 200 210 β>120 β=110-120 β=100-110 β=90-100 β<90

KUDA 5 STAFFA POSTERIORE / REAR BRACKET 97a 9197a 7b 9197a919 STAFFA ANTERIORE / FRT BRACKET 91 98a 8b 919

6 KUDA MANOVRA DI SBLOCCO OPERATORE SINISTRO / LEFT MOTOR UNLOCK MANEUVER 91 99a 9b 919 9199c 9d 919 MANOVRA DI SBLOCCO OPERATORE DESTRO / RIGHT MOTOR UNLOCK MANEUVER 91 99e 9199f 9g 919 9h 919

KUDA 7 COLLEGAMENTI ELETTRICI / ELECTRICAL CNECTIS 910 J5 J4 Motore 1 / Motor 1 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 Motore 2 / Motor 2 J5 J4 M1+ M1-5V S1 S2 5V M2- M2+ 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8. COLLEGAMENTO ELETTROSERRATURA / ELECTRIC LOCK INSTALLATI 911 91912 7 7 6 4 2 3 4 6 5 4 2 3 1 3 5 1 5

- (AS06050) Apparecchiatura elettronica ISTRUZII PER L INSTALLAZIE Electronic control unit INSTRUCTIS FOR INSTALLATIS I

11 1 - TECHNICAL SPECIFICATIS Control unit Type Power supply No. of motors Motor power supply Flashlight Accessory power supply Radio receiver Operating temperature Run time SC230 / AS05710 Electronic control unit for automation of a double swing gate with 24VDC motors 230 VAC single-phase 50/60 Hz 2 24 Vdc 24 Vdc 10W max 12 Vdc 10W max Integrated -20 C +60 C ENCODER 2 - TECHNICAL SPECIFICATIS/FUNCTIS Red warning LEDs for N.C. contacts and for programming. Buttons on the circuit board for programming and learning the radio controls. Automatic run time learning with simplified procedure. Onboard radio receiver that can store up to 200 radio controls. Control of the radio transmitter channels via jumpers. Deceleration during opening and closing. Deceleration speed adjustable via DIP switch. Stop and motion inversion after intervention of the safety devices. Anti-crushing function both at normal speed and in deceleration. Amperometric reading of motor absorption for the anti-crushing function adjustable via DIP switch. Pedestrian operation with fixed opening of 5 seconds. Two N.C. inputs programmable via DIP switch as photocell 1, photocell 2, N.C. frame or as opening device. Two possible operating logics: step-by-step with stop or condominium selectable via DIP switch. Gate phase shift time adjustable via DIP switch. Programming of automatic closing and pause time via DIP switch. Provision for use with buffer batteries. Soft-Start and Soft-Stop to limit mechanical shock. Thank you for choosing GIBIDI. CAREFULLY READ THESE INSTRUCTIS BEFORE PROCEEDING WITH INSTALLATI. WARNINGS: This product has been tested by GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves the right to change the technical data without prior notice in relation to product development. DISPOSAL: GI.BI.DI. advises recycling the plastic components and to dispose of them at special authorised centres for electronic components thus protecting the environment from polluting substances.

2 INSTALLAZIE APPARECCHIATURA / CTROL BOARD INSTALLATI 91

3 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91939192 J10 PHASE NEUTRAL LED1 1 2 J1 J2 1 2 24Vac + - BAT 24V F1 20A K5 DB1 K1 Q17 Q11 R60 R59 Q14 K2 K3 K4 SW2 SW1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 S2 S3 JP3 JP1 JP2 LED1 LED2 LED3 LED4 LED5 SYS-learn RF-learn SYS-learn LED2 START-PED LED3 PHOT1 LED4 PHOT2 LED5 RF-learn J4 J5 J3 J7 25 26 ANTENNA 24Vdc 10W MAX 1 2 3 4 5 6 7 8 LIT LIT + - LAT LAT + - + - + - M1 M2 9 10 11 12 13 14 15 16 +5Vdc S1 ENCODER M1 +5Vdc S2 ENCODER M2 17 18 19 20 21 22 23 24 START (NO) PED (NO) PHOT1 (NC) PHOT2 (NC) LED STATUS FLASHING

4 COLLEGAMENTO ALIMENTAZIE / POWER SUPPLY CNECTI 3 PHASE J10 INTERRUTTORE MAGNETOTERMICO OVERCURRENT CIRCUIT BREAKER NEUTRAL 230Vac INTERRUTTORE DIFFERENZIALE RESIDUAL-CURRENT DEVICE PHASE NEUTRAL COLLEGAMENTO MOTORE / MOTOR CNECTI 4 J5 J4 Motore 1 / Motor 1 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 S2 5V M2- M2+ M1+ M1-5V S1 Motore 2 / Motor 2 J5 J4 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8.

5 COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CNECTI 4 5 J4 24 Vdc 10W max 1 2 3 4 5 6 7 8 + - LIT LIT COLLEGAMENTO ELETTROSERRATURA / ELECTRIC LOCK CNECTI 6 J4 1 2 3 4 5 6 7 8 + - LAT LAT COLLEGAMENTO DISPOSITIVI DI COMANDO / CTROL DEVICES CNECTI 4 7 J3 17 18 19 20 21 22 23 24 PED (NO) START (NO)

6 DIP SWITCH SW2_1-2 CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS 4 8 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J3 17 18 19 20 21 22 23 24 PHOT1 (NC) J3 17 18 19 20 21 22 23 24 PHOT1 (NC) J3 17 18 19 20 21 22 23 24 J3 PHOT2 (NC) 17 18 19 20 21 22 23 24 PHOT2 (NC) 1 2 1 2 3 4 1 2 3 4 M1 ( AU02000 ) M2 1 2 2 3 3 4 1 1 2 1 2 3 3 4 M1 SW2 1 2 3 4 5 ( AU02000 ) M2 1 2 2 3 3 4 1 1 2 1 2 3 3 4 1 2 3 4 5 M1 ( AU01900 ) M1 ( AU01900 ) 1 2 3 4 1 2 3 4 M2 M2 1 2 3 4 5 1 2 3 4 5 PHOTO1 PHOTO1 PHOTO2 PHOTO2

7 DIP SWITCH SW2_1-2 4 9 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J3 17 18 19 20 21 22 23 24 PHOT2 (NC) J3 17 18 19 20 21 22 23 24 PHOT1 (NC) J3 17 18 19 20 21 22 23 24 PHOT1 (NC) 1 2 1 2 3 4 M1 SW2 ( AU02000 ) M2 1 2 2 3 3 4 1 1 2 1 2 3 3 4 NC NC 1 2 3 4 5 M1 ( AU01900 ) 1 2 3 4 NC M2 1 2 3 4 5 PHOTO1 PHOTO1 COSTA / SAFETY EDGE CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS

8 DIP SWITCH SW2_1-2 410 17 18 19 20 21 22 23 24 PHOT1 (NC) J3 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J3 17 18 19 20 21 22 23 24 J3 PHOT2 (NC) 17 18 19 20 21 22 23 24 PHOT2 (NC) 1 2 1 2 3 4 M1 NC NC SW2 ( AU02000 ) M2 NC 1 2 2 3 3 4 1 1 2 1 2 3 3 4 1 2 3 4 5 M1 ( AU01900 ) 1 2 3 4 M2 1 2 3 4 5 COSTA / SAFETY EDGE PHOTO2 PHOTO2 CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS

9 DIP SWITCH SW2_1-2 411 J5 9 10 11 12 13 14 15 16 J5 9 10 11 12 13 14 15 16 J3 17 18 19 20 21 22 23 24 J3 PHOT2 (NC) 17 18 19 20 21 22 23 24 PHOT2 (NC) J3 17 18 19 20 21 22 23 24 PHOT1 (NC) J3 17 18 19 20 21 22 23 24 PHOT1 (NC) 1 2 1 2 3 4 M1 SW2 ( AU02000 ) M2 1 2 2 3 3 4 1 1 2 1 2 3 3 4 1 2 3 4 5 M1 ( AU01900 ) 1 2 3 4 M2 1 2 3 4 5 PHOTO1 PHOTO1 COLLEGAMENTO OROLOGIO / EXTERNAL CLOCK SPIRA MAGNETICA / ELECTROMAGNETIC DETECTOR CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS

10 ESEMPI IMPOSTAZIE TASTI RADIOCOMANDO / TRANSMITTER BUTTS SET UP EXAMPLES 412 JP3 START PED JP3 PED START JP3 START PED JP3 PED START

11 CFIGURAZII AVANZATE JUMPER JP3 / ADVANCED JP3 JUMPER CFIGURATIS 413 JP3 TRANSMITTER START START PED PED NOTE / NOTES

12 3 - INSTALLATI WARNINGS Before proceeding with installation, fit a differential magnetothermal switch with a maximum capacity of 10A upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3mm. To prevent possible interference, differentiate and always keep the power cables (minimum cross-section 1.5 mm²) separate from the signal cables (minimum cross-section 0.5 mm²). Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product may compromise system safety. Keep all the materials contained in the packaging away from children since they pose a potential hazard. The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitable for the specific application are not used. When installation is complete, always carefully check proper functioning of the system and the devices used. This instruction manual addresses professionals qualified to install live equipment and therefore requires good technical knowledge and installation in compliance with the regulations in force. Maintenance must be carried out by qualified personnel. Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains. The control unit described in this document may only be used for the purpose for which it was designed. Check the intended end use and take all the necessary safety precautions. Use of the products for purposes different from the intended use has not been tested by the manufacturer and is therefore on full responsibility of the installer. Mark the automated device with visible warning plates. Warn the user that children or animals should not play or stand near the gate. Appropriately protect the dangerous points (for example, using a sensitive frame). 4 - WARNINGS FOR THE USER In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using original and certified materials. The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or lacking experience and knowledge, unless appropriately instructed. Do not access the circuit board for adjustments and/or maintenance. WARNING: IMPORTANT SAFETY INSTRUCTIS. It is important to follow these instructions to safeguard persons. Keep this instruction manual.

13 5 - ELECTRICAL CNECTIS: CNECTORS Terminal J1 Position 1 2 0 VAC from transformer 24 VAC from transformer Description J2 1 2 + Battery 24V - Battery 24V 6 - ELECTRICAL CNECTIS: TERMINAL BOARDS Terminal J4 J5 J3 J7 Position 1 Signal LIT+ 2 LIT- 3 LAT+ 4 LAT- 5 M1+ 6 M1-7 M2+ 8 M2-9 5V 10 S1 11 12 5V 13 S2 14 15 +12V 16 17 DKEY 18 SKEY 19 20 PHOT1 21 22 23 24 +12V PHOT2 25 26 ANTENNA Description FLASHLIGHT power supply 24 VDC MAX 10W. FLASHLIGHT power supply 24 VDC MAX 10W. Electric lock power supply 24 VDC. Electric lock power supply 24 VDC. Motor 1 + Motor 1 - Motor 2 + Motor 2 - Motor 1 ENCODER +5VDC power supply. Motor 1 ENCODER signal. Motor 1 ENCODER power and signal common. Motor 2 ENCODER +5VDC power supply. Motor 2 ENCODER signal. Motor 2 ENCODER power and signal common. External accessory power supply +12VDC MAX 10W. External accessory power common. START input (N.O.) PEDESTRIAN input (N.O.) External accessory power and signal common. Programmable safety device input (N.C.), DEFAULT = PHOTOCELL 1 External accessory power supply +12VDC MAX 10W. External accessory power and signal common. Programmable safety device input (N.C.), DEFAULT = PHOTOCELL 2 +12V External accessory power supply +12VDC MAX 10W. Antenna braid input Antenna signal input 7 - PROTECTI FUSES Position Value Type F1 15A T Description Protects the circuit board

14 8- WARNING LEDs Position Colour Signal LED1 LED2 RED RED 9 - DIP SWITCH SW1 - START-PED Description Short flash every second: at rest in one-motor mode. Double flash every second: at rest in two-motor mode. Long flash every second: during time learning. On fixed: gate travel learning procedure not executed or failed. The settings are stored during the rest phase (gate closed). The default settings are highlighted in the boxes with grey background. Comes on when the START or PEDESTRIAN control is activated from the terminal board or the receiver. LED3 RED PHOT 1 Always off. Comes on when the contact of terminal 20 is opened. LED4 RED PHOT 2 Always off. Comes on when the contact of terminal 23 is opened. LED5 RED Receiver Always off. Comes on when receiving a signal from the receiver. DIP Function Status Description DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DECELERATI ANTI-CRUSHING THRESHOLD PAUSE TIME Disables the deceleration function. Enables deceleration during opening and closing. The deceleration speed is adjusted with the DIP switch SW2_6. Very high sensitivity. High sensitivity Medium sensitivity Low sensitivity Automatic closing disabled. 3 seconds. 10 seconds. 20 seconds. 40 seconds. 60 seconds. 120 seconds. 300 seconds.

15 8 - DIP SWITCH SW1 DIP Function Status Description DIP 7 STEP-BY-STEP WITH STOP CDOMINIUM Operation in response to the START command: Gate closed OPENS During opening STOPS Gate open CLOSES During closing STOPS After a STOP inverts the motion Operation in response to the START command: Gate closed OPENS During opening UNINFLUENTIAL Gate open Reloads the automatic closing time if automatic closing is enabled, otherwise it closes. DIP 8 PRE-FLASHING Enables pre-flashing of 3 seconds before motor activation during opening and closing. Disables pre-flashing. 10 - DIP SWITCH SW2 The settings are stored during the rest phase (gate closed). The default settings are highlighted in the boxes with grey background. DIP Function Status Description Terminal 20 functions as PHOTOCELL 1 input. Terminal 23 functions as PHOTOCELL 2 input. DIP 1 DIP 2 TERMINALS 20 and 23 PROGRAMMING Terminal 20 functions as PHOTOCELL 1 input. Terminal 23 functions as N.C. FRAME input. Terminal 20 functions as PHOTOCELL 1 input. Terminal 23 functions as OPEN input. Terminal 20 functions as N.C. FRAME input. Terminal 23 functions as PHOTOCELL 1 input. Motor 2 delay during opening: 2 seconds. Motor 1 delay during closing: 3 seconds. DIP 3 DIP 4 GATE PHASE SHIFT TIME Motor 2 delay during opening: 2 seconds. Motor 1 delay during closing: 5 seconds. Motor 2 delay during opening: 3 seconds. Motor 1 delay during closing: 4 seconds. Motor 2 delay during opening: 3 seconds. Motor 1 delay during closing: 6 seconds.

16 10 - DIP SWITCH SW2 DIP Function Status Description Enables the water hammer function during opening to help electric lock release. DIP 5 WATER HAMMER Operation: at the START command, the following will occur in sequence: - electric lock activation; - closing pulse of 1 sec; - opening; - electric lock release after 2 sec. Disables the water hammer function. DIP 6 DECELERATI SPEED Deceleration speed equal to 70% of the maximum speed. Deceleration speed equal to 50% of the maximum speed. DIP 7 MOVEMENT SPEED Speed during normal movement equal to 100% of the maximum speed. Speed during normal movement equal to 70% of the maximum speed. DIP 8 NUMBER OF MOTORS System configured for 2 motors. System configured for 1 motor. 11 - TERMINALS 20 and 23 OPERATING MODE GATE STATUS GATE CLOSED GATE OPEN DURING CLOSING DURING OPENING PHOTOCELL 1 EFFECT - RELOADS THE PAUSE TIME OPENS - GATE STATUS GATE CLOSED GATE OPEN DURING CLOSING DURING OPENING PHOTOCELL 2 EFFECT - RELOADS THE PAUSE TIME OPENS STOPS UNTIL RELEASE, THEN OPENS

17 12 - TERMINALS 20 and 23 OPERATING MODE GATE STATUS GATE CLOSED GATE OPEN DURING CLOSING DURING OPENING N.C. FRAME EFFECT - RELOADS THE PAUSE TIME STOPS, INVERTS THE MOTI FOR 2 SECDS, STOPS UNTIL RELEASE, THEN OPENS STOPS, INVERTS THE MOTI - FOR 2 SECDS, STOPS UNTIL RELEASE, THEN CLOSES GATE STATUS GATE CLOSED GATE OPEN DURING CLOSING DURING OPENING OPENING DEVICE EFFECT OPENS RELOADS THE PAUSE TIME OPENS - 13 - BOARD RADIO RECEIVER CTROL Storing a new transmitter in memory: 1- Press and hold down the RF-learn button for 3 seconds. 2- LED 5 will come on. 3- Press button 1 of the radio control to be stored for 2 seconds. 4- LED 5 will flash 3 times and the new radio control is stored. 5- LED 5 will stay on for another 10 seconds; during this period, you can store other transmitters, restarting from step 3. Clearing the memory: 1- Press and hold down the RF-learn button for 10 seconds. 2- LED 5 will initially come on and then go off after 10 seconds. 3- All the transmitters have now been deleted. Assigning START and PED commands to the transmitter buttons: Refer to Figure 12.

18 DESRCIZIE 14 - GATE TRAVEL MENU LEARNING ( A ) If using two motors, the DIP switch SW2_8 must be. If using only one motor, it must be connected to the terminals M1 and the DIP switch SW2_8 must be. Intervention of any anti-crushing or START-PED command safety device during the learning phase results in the learning process being interrupted and exited and it will have to be repeated. Learning procedure: Release the operators and move the gates to halfway their travel. Lock the operators. Check that the mechanical opening and closing stops are present on the ground. Remove any obstacles in the range of action of the automated device. Check that LED2, LED3, LED4 and LED5 are off. Press and hold down the SYS-learn button for 3 seconds. LED1 will start flashing with a long flash once a second. Press button 1 of the radio control or give a START pulse from the terminal board. Movements during learning with 2 motors: Motor 2 closes until meeting the mechanical end-stops on the ground. Motor 1 closes until meeting the mechanical end-stops on the ground. Motor 1 opens until meeting the mechanical end-stops on the ground. Motor 2 opens until meeting the mechanical end-stops on the ground. Motor 2 closes until meeting the mechanical end-stops on the ground. Motor 1 closes until meeting the mechanical end-stops on the ground. End of learning; LED1 will flash twice a second. Movements during learning with 1 motor: Motor 1 closes until meeting the mechanical end-stops on the ground. Motor 1 opens until meeting the mechanical end-stops on the ground. Motor 1 closes until meeting the mechanical end-stops on the ground. End of learning; LED1 will flash briefly once a second. DESRCIZIE 15 -TROUBLESHOOTING MENU ( A ) The gate does not move after a START command. Check that LED3 and LED4 are off; if not, check the devices connected to terminals 20 and 23. Check that LED1 is not on fixed; if it is, carry out a new gate travel learning procedure. Check fuse F1. Check that the battery voltage is not below 22VDC. The gate does not fully open/close. The transmitter capacity is very low. Check the motor and encoder connections. Check that terminals 25 and 26 are well secured.

19 The manufacturer: EC Declaration of conformity GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the product: ELECTRIC CTROL UNIT is in conformity with the following EEC Directives: LVD Directive 2006/95/EC and subsequent amendments EMC Directive 2004/108/EC and subsequent amendments and that the following harmonised standards have been applied: EN60335-1, EN61000-6-2, EN61000-6-3 Legal Representative Michele Prandi Date 26/05/14

Cod. AIC8792-06/2014 - Rev. 00 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: info@gibidi.com Numero Verde: 800.290156 w w w. g i b i d i. c o m