Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

Similar documents
LVDT/HC PILOT BURNER. External raw gas pilot burner

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles

APX Nozzle-mix line burner

APX Nozzle-mix line burner

Low emissions, high performance natural gas burners

APX Nozzle-mix line burner

MULTIFIRE. High temperature dual fuel burner

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

KINEMAX. Medium velocity gas or oil burners

VALUPAK. Packaged gas burners

Specifications of MAXON VALUPAK burners for 50 Hz operation

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG

Capacities and Operating Data

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

Eclipse RatioAir Burners

VALUPAK. Packaged gas burners

Specifications of OPTIMA SLS Burners

Design and Application Details

Design and Application Details

MAXON OVENPAK LE. Low emissions, high performance gas burners. Technical Catalog

Start-up Instructions

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

North American 4485 Tempest SE

Design and Application Details

Eclipse RatioAir Burners

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

Assembly Numbers Style A, B & C LINOFLAME Burners

Assembly Numbers. Approximate net ship weight (in pounds) shown in parentheses

M SERIES TECHNICAL DATA INFORMATION PACKET

SOA - Orifice Assembly

High Tension Spark Igniter (HTSI)

Pilot Capacities/Specifications

2.0 Burner Operating Parameters and Requirements

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division


Data /1/07 Eclipse RatioAir Burners Model RA0040

FABER BURNER ROUTINE MAINTENANCE

North American 4575 HiRAM

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Differential Pressure Switch QBM81-

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

BLOC U A-12G BLOC U C-12G

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

CHALLENGER Propane to Natural Gas Instructions

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

BBC Multi-fuel Combination Beta Burner

Differential Pressure Switch QBM81-

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU225-X NF

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU220-X NF

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Proportional controlling element

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

3 Edition Product brochure GB AGA

Eclipse Vortometric Burners Series HI

Butterfly valves Figure 56 Installation & Maintenance Instructions

ONE STAGE GAS BURNERS RDBS SERIES

Performance Selection Data

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

Instruction General Vacuum Valve program

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

Orifice Flow Meters POP-S (E5720 rev /03/2013)

S1 SERIES TECHNICAL DATA INFORMATION PACKET

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Design and Application Details

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

1470 SERIES HOT AIR GAS BURNER

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

F200 Pilot Operated Pressure Regulator

GEMINI GAS CONTROL PRODUCT INFORMATION

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Flow Computer Installation

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M

3-port seat valves PN10 with flanged connection

3-Port Seat Valves with Flange, PN 10

3-port seat valves PN6 with flanged connection

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Figure 1-1(d) Tft Installation Kit

Tightness control TC. Product brochure GB Edition 12.10

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

D SERIES TECHNICAL DATA INFORMATION PACKET

P99 Pressure Reducing Regulator

D SERIES TECHNICAL DATA INFORMATION PACKET

T-TYPE & IN-LINE FILTERS

Transcription:

4-22.4-4 Specifications of LVDT/HC-pilot burner Typical burner data 15 C 21 % O 2 combustion air 50 % humidity natural gas with 10.9 kwh/m³(st) HHV - sg = 0.6 [1] Stated pressures are indicative - actual pressures are function of air humidity, altitude, type of fuel, gas quality Type LVDT HC STD Capacity kw (HHV) 20 (15-25) 20 (15-25) 85 ir (required air flow on scanner connection) m³(st)/h 3,5-4 3,5-4 3,5-4 ir pressure (relative to process back pressure) [2] mbar 70 70 70 Natural gas pressure (relative to process back pressure) [2][3] mbar 30 2000-4000 2000-4000 Propane pressure (relative to process back pressure) mbar 12 1000-2000 1000-2000 Flame length (outside the pilot burner) [4] mm 100-150 100-150 200 [1] sg (specific gravity) = relative density to air (density air = 1.293 kg / m³(st) ). [2] Measured at pilot inlet. [3] Customized orifices can be supplied for different gas pressures. [4] Measured from outlet pilot tube (see page 4-22.4-3). The LVDT/HC-pilot burner is designed for interrupted operation. For special application and in specific conditions, an intermittent pilot version may be supplied on request. Contact MXON for more details. Materials of construction Pilot tube ISI304 (1.4301) Spark ignitor holder ISI304 (1.4301) Spark ignitor ISI304 (1.4301) + porcelain insulator all valve ISI304 (1.4301)

4-22.4-5 Selection criteria Refer to the product data of IRFLO LV, HC, DELT-TE and COMUSTIFUME burners. Refer to page 4-22.4-3. Standard available LVDT/HC-pilot burners (other combinations are possible on request) Pilot type Length X (mm) MXON compatible burners LVDT-450 450 LV / COMUSTIFUME / DELT-TE LVDT-600 600 LV / COMUSTIFUME / DELT-TE LVDT-750 750 LV / COMUSTIFUME / DELT-TE LVDT-900 900 LV / COMUSTIFUME / DELT-TE LVDT-X customized max.: 1500 LV / COMUSTIFUME / DELT-TE HC-X-SM customized max.: 1500 HC-S / HC-M / LV / COMUSTIFUME / DELT-TE HC-X-L customized max.: 1500 HC-L HC-US-X-SM customized max.: 1500 HC-S / HC-M / LV / COMUSTIFUME / DELT-TE HC-US-X-L customized max.: 1500 HC-L HC-EEx-X-SM customized max.: 1500 HC-S / HC-M / LV / COMUSTIFUME / DELT-TE HC-EEx-X-L customized max.: 1500 HC-L HC-STD-X customized: 1500-5000 HC-S / HC-M / LV / COMUSTIFUME / DELT-TE HC-STD-US-X customized: 1500-4000 HC-S / HC-M / LV / COMUSTIFUME / DELT-TE When TEX category 2G (European hazardous area zones 1 & 2) applies, an EEx type pilot burner shall be selected. dditional material needs to be ordered in this case: ignition coil spark pulse generator (SPG) EExd-box to house the SPG in case the SPG is mounted in an hazardous area itself For use in very humid atmospheres (low temperature dryers) a special quartz insulated spark ignitor is optionally available. Refer to page 4-22.4-9.

4-22.4-6 Dimensions & weights LVDT / HC - types (non EEX, non STD) 1) UV scanner connection 1 2) Scanner cooling & combustion air inlet 1/2 3) lternative cooling & comb. air inlet 1/2 4) Test connection combustion air 1/8 5) Pilot gas inlet 1/4 6) Spark ignitor O/ F E O/ 10 L 6 2 4 D 1 4x O/ C 7) Pilot gas pressure test connection 8) Stainless steel pilot tube 8 9 9) Gasket 10) all joint (only on L type) 5 7 3 4 Dimensions in mm unless stated otherwise Weight C ø D E ø F ø (kg) 80 100 10 250 57 74 2 + (6 x L*) * L = tube length in m ir, gas and test connections are ISO female threaded for European versions, NPT female threaded for US version pilots. Except UV scanner connection: this is ISO female threaded in both versions.

4-22.4-7 LVDT / HC-SM / HC-L - EEx -types 1) UV scanner connection 1 2) Scanner cooling & combustion air inlet 1/2 3) Pressure test connection 1/2 4) Test connection combustion air 1/8 5) Pilot gas inlet 1/4 6) EEx spark ignitor O/ F O/ E 10 L 8 9 2 4 D 6 1 O/ 4x O C 7) Pilot gas pressure test connection 8) Stainless steel pilot tube 9) Gasket 10) all joint (only on HC L type) 5 7 3 4 Dimensions in mm unless stated otherwise Weight C ø D E ø F ø (kg) 80 100 10 250 57 74 2 + (6 x L*) * L = tube length in m ir, gas and test connections are ISO female threaded for European versions, NPT female threaded for US version pilots. Except UV scanner connection: this is ISO female threaded in both versions.

4-22.4-8 LVDT / HC-SM / HC-L - STD - types 1) UV scanner connection 1 2) Scanner cooling & combustion air inlet 1/2 3) Pressure test connection 1/2 4) Test connection combustion air 1/8 5) Pilot gas inlet 1/4 6) EEx spark ignitor 7) Pilot gas pressure test connection 8) Stainless steel pilot tube 9) Gasket 10) all joint (only on HC L type) O/ OF O/ OE 10 2 4 1 L D 8 9 6 5 7 4 3 O/ 4x OC Dimensions in mm unless stated otherwise Weight C ø D E ø F ø (kg) 80 100 10 250 57 74 2 + (6 x L*) * L = tube length in m ir, gas and test connections are ISO female threaded for European versions, NPT female threaded for US version pilots. Except UV scanner connection: this is ISO female threaded in both versions.

4-22.4-9 Spark ignitors Spark ignitors are available in different lengths and can be ordered separately. MXON advises to keep spark ignitors as spare parts. The spark ignitors are supplied including the spark ignitor holder, which facilitates on site replacement. Type Length (mm) SI-LVDT-450 400 [1] L = pilot burner tube length vailable spark ignitor types Remark SI-LVDT-600 550 SI-LVDT-750 700 standard length SI-LVDT-900 850 SI-LVDT-X L-50 [1] customized length SI-HC-EEx-X L-50 [1] spark ignitor for EEx pilot burners SI-HC-STD-X L-50 [1] spark ignitor for boosted pilot burners SI-LVDT-QRTZ L-50 [1] one piece quartz insulator for use in very humid atmospheres To define the spark ignitor, the correct type should be known. In addition, the length should be specified when ordering. This length can be determined by measuring the length of the spark ignitor from the tip to the holder or it can be found engraved in the spark ignitor holder. 1 1) length Spark ignitor with holder

4-22.4-10 Installation and operating instructions pplication requirements View port view port to inspect burner flame is essential to inspect flame aspect. It is recommended to install the view port downstream the burner on the opposite side of the process air duct. Required ancillary equipment Ensure that all required ancillary equipment for safe operation and correct performance of the LVDT/HC-pilot burner is installed, as described in the applicable local codes and/or process-related instructions. Proper adjustment of air- and gas pressures is essential for optimal operation of the burner. Positioning of the LVDT/HC-pilotburner. The LVDT/HC-burner is designed to be used on IRFLO HC, LV, COMUSTIFUME and DELT-TE burners. They shall only be mounted on these burners on the special mounting plates foreseen. Refer to literature on above mentioned MXON burners. Installation Storage LVDT/HC-pilot burners should be stored dry (inside). Prevent that water and/or dust can penetrate into the burner parts during storage. Handling Handle burner with care during unpacking, transport, lifting and installation. Use proper equipment. ny impact on the burner could result in damage. Pay special attention when handling QRTZ type spark ignitors since these are very fragile. Flange the pilot burner to the installation Each pilot burner is equipped with a mounting plate that fits the mounting plate of the main burner. olt this mounting plate to the main burner. Use proper gasket, included with the pilot burner. Tighten the four flange bolts with the correct torque. Retighten all bolts after first firing and regularly after commissioning. Refer to main burner specification sheets for correct mounting position. Orientation The orientation of the pilot burner on the main burner shall always ensure that the spark ignitor is mounted upstream (= closest to the burner body) of the UV scanner. Pilots should be mounted horizontally or vertically facing down. Vertical mounted pilot burners are possible but special attention is required to avoid accumulation of foreign material in the scanner tube.

4-22.4-11 Start-up instructions Instructions provided by the company or individual responsible for the manufacture and/or overall installation of a complete system incorporating MXON burners take precedence over the installation and operating instructions provided by MXON. If any of the instructions provided by MXON are in conflict with local codes or regulations, please contact MXON before initial start-up of equipment. Safety interlocks Guarantee that all the required safety locks as described in the applicable local codes or regulations, or supplementary safety interlocks required for safe operation of the overall installation, are working properly and resulting in a positive safety-lock of the burner. Do not bypass any of these safety interlocks, this will result in unsafe operation. Checks during and after start-up During and after start-up, check the integrity of the system. Check all bolted connections after first firing (first time on temperature) and retighten if necessary. Purge For safety-reasons, it is required to purge the installation sufficiently long to ensure that all possible combustibles are evacuated before ignition. Refer to the applicable local codes and your specific application requirements to determine the purge time. Pilot ignition Read the combustion system manual carefully before initiating the start-up and adjustment procedure. Verify that all of the equipment associated with and necessary to the safe operation of the burner system has been installed correctly, that all pre-commissioning checks have been carried out successfully and that all safety related aspects of the installation are properly addressed. Initial adjustment and light-off should be undertaken only by a trained commissioning engineer. Pilot burner does not require adjusting thanks to its fixed gas and air orifices. Refer to table page 4-22.4-4 for correct differential pressures.

4-22.4-12 Maintenance and inspection Safety requirements Regular inspection, testing and recalibration of combustion equipment according to the installation s manual is an integral part of its safety. Inspections activities and frequencies shall be carried out as specified in the installation s manual. Perform the following activities at least annually as part of a recommended preventative maintenance routing: Inspect burner internal parts for wear and oxidation, paying special attention to the spark ignitor tip Inspect associated control instruments and devices for function with particular attention to all safety permissive switches Visual inspections Regular visual inspection of all connections (air and gas piping to the burner, bolting of the burner mounting flange, burner support in the duct) and burner flame shape and aspect are essential for safe operation. Recommended spare parts Keep local stock of spark ignitor and holder. It is not recommended to keep local stock of other pilot burner parts.