Turbo-Cool 6" Recirculating Evaporative Cooling Installation & Operator s Instruction Manual

Similar documents
Turbo-Cool 6" Recirculating Evaporative Cooling Installation & Operator s Instruction Manual

Turbo-Cool Stand-Off 6" Recirculating Evaporative Cooling Installation & Operator s Instruction Manual

Turbo-Cool Stand-Off With Open Top 6" Recirculating Evaporative Cooling Installation & Operator s Instruction Manual

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

Turbo-House Air Inlet Installation & Operator s Instruction Manual

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

48" Vanguard Slant Wall and Cone Belt Drive Fans Installation & Operator s Instruction Manual

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

Feed Scale Installation & Operator s Instruction Manual

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Model 90 Twin Control Unit

48 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual

52" Turbo Fan with Hyflo Door

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems. Model 108 Two Motor Tandem Installation Instruction

54" Galvanized Hyflo Fan Installation & Operator s Instruction Manual

Swivel Top Linear-Lift Installation & Operator s Instruction Manual

Swivel Top Linear-Lift

Extension Boot System

30Deg.Two Motor Tandem

52" TURBO Fan with HYFLO Door Installation & Operator s Instruction Manual

Strap Winch Installation and Operators Instruction Manual

Light Duty Winch. Part #25800 Installation & Operator s Instruction Manual

Curtain Timer Control

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems

Strap Winch Installation and Operators Instruction Manual

AS-57FMH Flush Mount Kit AS-57EBDBP

52" TURBO Fan with HYFLO Door and One Piece Cone Installation & Operator s Instruction Manual

HS583 Sprocket Models- Curtain/Vent Machine

57" Endura Flush Mount Fan

48" and 52" Hyflo TM Un-Assembled Fans Assembly Manual

WET WALL. EvApORATIvE COOLINg SySTEm. 10" x 8" Tee INSTALLATION INSTRUCTIONS

Cage Nipple Watering. Installation & Operator s Manual. warranty installation operation parts list maintenance

SUBMERSIBLE SUMP PUMPS

Volume III (December 1995 to January 2007)

Swivel Top Linear-Lift Installation & Operator s Instruction Manual

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

Swivel Top Winch Installation & Operator s Instruction Manual

36" Hyflo Retrofit Kit Installation & Operator s Instruction Manual

HS593 Feed Line Control Unit 230V Single Phase

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

HALLMARK INDUSTRIES INC

Matala. VersiFlow Series. Instruction and Maintenance Manual

CRD610 Automatic Fitting Inserter

PRE-PLUMBED SEWAGE SYSTEM

ESE Series Cast Iron Sewage Pumps

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

57" Endura Flush Mount Fan

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Feeder Strap Winch. Part Number 54812

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Operating and Installation Instructions

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

GeyserMax-Flow Series

Intended Use: Explanation of Signal Word Consequences

36" Hyflo Retrofit Kit Installation & Operator s Instruction Manual

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

General Medium Duty KLM C&C 2-Stage Rear Air Suspension Installation Instructions

INSTALLATION INSTRUCTIONS

TBM Series 3-Way Ball Valve

Pressurized Bead Filters

Nipple Watering Installation & Operators Instruction Manual

CRD600 Automatic Fitting Inserter

INSTALLATION INSTRUCTIONS

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

Model 8317 Combination Shower Eye/Face Wash

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Instruction Manual. Fudge Puppy Display Case

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

SAFETY INFORMATION & INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

G8 Portable Fuel Transfer Pump Owner s Manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

StormPro BCV400 Sewage Ejector Pump

INSTALLATION INSTRUCTION & OWNER S MANUAL

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Air Storm Fans AS-57EBDBP AS-57EBDBP-HE

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual. Lift-Rite Hand Pallet Trucks Model PST Plus

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Universal Installation Instructions

Installation Instructions

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Installation Instructions

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

Transcription:

Turbo-Cool " Recirculating Evaporative Cooling Installation & Operator s Instruction Manual MV44-00 November 000

Chore-Time Warranty " Recirculating Evaporative Cooling Chore-Time Warranty Chore-Time Equipment ( Chore-Time ) warrants each new Chore-Time product manufactured by it to be free from defects in material or workmanship for one year from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement or repair of the product are not covered by the Manufacturer. Conditions and Limitations. The product must be installed by and operated in accordance with the instructions published by the Manufacturer or Warranty will be void.. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer. 3. This product must be purchased from and installed by an authorized distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. Consequential or Special Damages as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE MANUFACTURER S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Chore-Time Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for Chore-Time products in addition to those terms expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models. Effective: November 000 Chore-Time Equipment A Division of CTB, Inc. P.O. Box 000 Milford, Indiana 454-000 U.S.A. Phone (9) 58-40 Fax (877) 730-885 Email: ctb@ctbinc.com Internet: http//www.ctbinc.com Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should arise, your Chore-Time distributor can supply the necessary information to help you.

Contents Topic Page User Chore-Time Warranty................................................ Support Information.......................................................4 General............................................................. 4 DANGER: Electrical Hazard............................................4 Technical Information................................................ 5 Materials and Tools Required for Installation...................................5 Planning Information................................................. System Layout:........................................................... Framing Information................................................. 7 Framing Continued.........................................................9 Evaporating Cooling System Installation................................. 0 Splash Plate and Pipe Hanger Installation..................................... 0 Sump Preparation........................................................ Sump End Clamp Assembly................................................ Sump Support Assembly.................................................. Trough Installation....................................................... 3 Sump End Insert Assembly................................................. 4 End Panel Installation..................................................... 5 Distribution Pipe Installation............................................... End Panel Support Installation.............................................. 7 Pad Support Installation................................................... 7 Caulking of End Panel.................................................... 8 Evaporative Cooling Pad and Cover Installation................................ 9 Cooling Pad and Cover Installation Continued.................................. 0 Cooling Pad and Cover Installation Continued.................................. Trough End Insert Installation.............................................. Sump Components Installation.............................................. 3 System Start-Up..................................................... 4 System Operation & Maintenance...................................... 5 Parts Lists and Kits.................................................. Sump Kit Part No. 4340.................................................. Distribution Kit Part No s. 448-5 and 448-0.............................. 7 End Panel Kit Part No. 448 and Center Panel Kit Part No. 4345................. 8 Miscellaneous Components................................................ 9 C,D C,D,I C,D,I C,I C,I I C,I C C,D,I * Legend: C = Customer (end user), D = Distributor (sales), I = Installer of equipment 3

" Recirculating Evaporative Cooling General General Support Information The Turbo-Cool '' Recirculating Evaporative Cooling System is designed to help cool livestock and poultry houses. The system is shipped unassembled. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury. This manual is designed to provide installation, operation, and parts listing information. The Table of Contents provides a convenient overview of the information in this manual. The Table of Contents also specifies which pages contain information for the sales personnel, installer, and consumer (end user). Safety Information DANGER: Electrical Hazard Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. 4

" Recirculating Evaporative Cooling Technical Information Technical Information Materials and Tools Required for Installation Socket Wrench 5/ 3/8, and 7/" Sockets Teflon Tape PVC Cement Utility Knife Saw Tape Measure Chalk Line Caulking Pressure Treated Lumber for Framing See Figure Required fresh water supply Outside Air Water Required in Gallons/Minute Temp in F % Relative Humidity Per 00 sq. ft. of Pad * 0 0 3. 0 0.5 00 0.3 00 30.9 00 40.5 95 40.4 *Assumes 80% pad efficiency and 45 fpm air velocity through pad Supply water pressure: 0-00 psi Water Quality: - 9 PH, salt concentration less than 40,000 ppm Pump Part No. Important! Model HP Submersible Pump Options Electrical Specifications Start Run Volts HZ PH Amps Amps Maximum Pad Length 38480 CIA 3/0 0 50 7 5 40 Yes 38480 CIA 3/0 30 0 7 5 50 Yes 4400 E-CIM /3 30 0 7 4.8 50 No 498 9E-CIM 4/0 30 0 9 0 No 4987 0E-CIM / 08/40 0 0 5 70 No 4987 0E-CIM / 08/40 50 0 5 50 No Automatic Water Level Shut- Off Switch Chore-Time Equipment strongly recommends that a good alarm system should be installed in confinement buildings to warn of power failure and high temperature. Chore-Time Equipment also recommends that an alternate power source be available for confinement buildings in case of power failure. 5

Planning Information " Recirculating Evaporative Cooling Planning Information System Layout: The Sump Assembly may be installed at either end of the system or in the middle. Maximum Length - 70' MV44-00 Maximum length = 70 Figure. Optional Sump locations The maximum length of Cooling Pad on either side of the Sump Assembly is 70', if the cooling system is longer than 70' the sump must be installed in the middle of the system. The maximum amount of slope is -/"[38 mm] per system. The sump end must be level with, or lower than the rest of the trough.

" Recirculating Evaporative Cooling Framing Information Framing Information Figure shows two options for installing the cooling pad relative to the tunnel curtain and provides information for the Evaporative Cooling System opening with Sump on either end. See Figure 3 for opening information for Evaporative Cooling System with Sump in the middle It is recommended to frame the Pad opening using treated lumber. Note:. Determine the location of the bottom stringer. See Figure, Item 3. Use Wood or Lag Screws to secure the Bottom Stringer to the Studs. The Lower Stringer must be capable of supporting 30 lbs/ft [45 kg/m] plus 3 lbs/ft [4 kg/m] for each foot of Cooling Pad Height. Example: A ' Cooling Pad requires a Stringer capable of supporting 30 lbs/ ft + (3 lbs/ft x ') = 48 lbs/ft.. Determine the location of the top stringer. See Figure, Item 8. The distance between the top and bottom stringers should be approximately -/'' [38 mm] less than the height of the Evaporative Cooling Pads. Example: For a 0'' [54 mm] tall Evaporative Cooling Pad the distance between the stringers would be 0'' [54 mm] - -/'' [38 mm] = 58-/ '' [48 mm]. The slope (if any) of the top stringer must be the same as the bottom stringer. 3. Snap a chalk line on the lower stringer at the locations specified in Figure, Item 3. This chalk line will determine the location of the lag screws for the Trough Supports. 4. Snap a chalk line on the top stringer at the locations specified in Figure, Item. This chalk line will determine the location of the Splash Plate lower holes. 5. A short section of x lumber (Figure, Item 0) is required beneath the bottom stringer at the sump end to provide a back support for the sump assembly. 7

Framing Information " Recirculating Evaporative Cooling Option Option 9 0 3 0 3 4 8 8 5 7 8 4 5 7 9 3 9 0 0 MV44-007 07/00 Curtain x '' [38 x 40 mm] Bottom Stringer.5'' [5. mm] Minimum Clearance Pad Height plus -3/4'' [70 mm] 3 4-/'' [38 mm] Minimum Clearance 3 -/4'' [3 mm] 4 30'' - 3'' [7-94 mm] Walkway 4 Bottom Stringer Chalk Line 5 '' [5 mm] Minimum Clearance 5 Top Stringer Chalk Line x '' [38 x 40 mm] Top Stringer 9'' [43 mm] for Sump Assembly 7 Wall Studs 7 '' [5 mm] for Trough End Insert 8 Pad Height less -/'' [38 mm] 8 7-/'' [9 mm] 9 End Framing 9 '' [5 mm] 0 Width of Pad Bank 0 x Sump Back Support Figure. Framing overview diagram (Sump at either end) 8

" Recirculating Evaporative Cooling Framing Information Framing Continued... 3 4 5 MV98-3 /99 " [5.4 mm] Minimum Clearance for Trough End Insert Cover this opening 3 8" [458 mm] 4 / Total System Length rounded to nearest 5' increment 5 Remainder of Total System Length Total System Length plus 8" [458 mm] Note: See Figure for all other framing information Figure 3. Frame opening dimensions for Sump in middle 9

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Evaporating Cooling System Installation Note: Splash Plate and Pipe Hanger Installation The end holes in the Splash Plate must align with the chalk line and the end of the first Splash Plate must be flush with the inside of the end framing. See Figure 4. Secure the Splash Plates to the upper stringer, using a 0x-/4'' screw at each end. Secure the Pipe Hangers to the stringer, through the Splash Plate, using (4) 0x-/4'' screws. The lower hole in the Pipe Hanger should align with the chalk line on the stringer. Hang remaining Splash Plates butting them tightly end to end. If the last Splash Plate is too long to fit within the end framing, cut as shown in Figure 4. 5 4 7 3 MV98-33 /99 0 x -/4'' Screw Pipe Hanger 3 Splash Plate 4 Upper Stringer 5 Chalk Line Flush with edge of end framing 7 Cut here if too long Figure 4. Splash Plate & Pipe Hanger Installation 0

" Recirculating Evaporative Cooling Evaporating Cooling System Installation Sump Preparation Determine which side of the Sump will need to be modified before installation. If the Sump is to be installed to the right of the Trough, the left side of the Sump will need to be cut at the indicated cut line. If the Sump is to be installed to the left of the Trough, the right side of the Sump will need to be cut at the indicated cut line. To install the sump in the middle of the system, cut both /" Sump End Caps off the Sump. See Figure 5. Decide which side of the Sump will be used for the drain and cut off that end. NOTE: Make cut for one drain only. Install the -/'' Drain Plug. 7 3 4 MV44-008 07/00 Sump End Cap Cut Line Sump 3 /" Sump End Cap 4 Side of sump mounted to wall 5 Optional Drain Plug Locations -/" Drain Plug 7 Drain Cut Line 5 Figure 5. Cutting the Sump Sump End Clamp Assembly Place the " x 4" self adhesive tape around the Sump End and assemble the Clamp with the Insert as shown in Figure 5 4 3 Sump End Insert Sump 3 Self Adhesive foam tape 4 /4" x 3-/" Clamp Bolt 5 -/" Clamp Nut Clamp Strap MV44-0 O7/00 Figure. Sump End Clamp Assembly

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Sump Support Assembly Align the top holes in the Sump Support Assembly with the Chalk Line on the Bottom Stringer, with the first top hole " [5 mm] away from the inside edge of the framed opening (See Figure 7, Items,, &7). Use two /4 x -/" Lag Screws and two Washers to fasten the Sump Support Assembly to the Lower x Sump Support as shown in Figure 7. 9 3 7 4 Sump Support Assembly Inside Edge of Framed Opening 3 Bottom Stringer 4 Chalk Line 5 /4 x -/" Lag Screws /4" Hole nearest Framed Opening 7 " [5mm] 8 Lower x Sump Support 9 /4 x " Washer 5 MV44-03 09/00 8 Figure 7. Sump Support Assembly Align the two /4'' holes in the rear of the Sump with the top two /4" holes in the Sump Support Assembly (See Figure 8). Attach the Sump and Sump Support to the Bottom Stringer with two /4x-/" Lag Screws and Washers. 4 3 5 7 Sump Support Assembly Trough end of Sump 3 Sump 4 Edge of Framed Opening 5 Bottom Stringer Chalk Line /4 x -/" Lag Screw 7 /4" x " Washer 8 Lower x Sump Support MV44-00 07/00 8 Figure 8. Attaching the Sump to the Bottom Stringer

" Recirculating Evaporative Cooling Evaporating Cooling System Installation Trough Installation Orient the Trough with the top hole to the left of the bottom hole (See Figure 9, Item ). Hang the Trough from the Bottom Stringer beginning with one end of the Trough Material against the Sump, and the top holes in the Trough Material aligned with the Chalk Line. The top holes in the Trough Material and the Chalk Line mark the location for the Trough Supports. Use the /4 x -/" Lag Screws to attach the Trough Supports and Trough Material to the Bottom Stringer as shown in Figure 9. Wipe the inside of the Trough at each end to remove debris that may prevent sealing. Trough Material Bottom Stringer 3 Chalk Line 4 Trough Support 5 /4 x -/" Lag Screw Top Hole Offset to left of Bottom Hole MV98-5 08/98 Figure 9. Installing the Trough 3

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Form the Trough into a "U" shape as shown in Figure 0 and fasten the Trough to the Trough Support using the /4" Drive Rivets. Insert the /4" Drive Rivet through the hole in the Trough and the Trough Support. Use a hammer to hit the /4" Drive Rivet head to lock it in place. Repeat the process for each Trough Support. MV98-9 8/98 Bottom Stringer /4 x -/" Lag Screw 3 Trough Support 4 Trough Material 5 /4" Drive Rivet Figure 0. Forming the Trough Sump End Insert Assembly At the Sump end hook the free end of the Clamp Strap to the Sump End Insert and tighten the /4" clamp bolt to seal the joint between the Trough and the Sump. 5 4 Sump /4" Clamp Bolt 3 Trough 4 Clamp Strap 5 Sump End Insert 3 MV44-08 Figure. Sump End Insert Assembly 4

" Recirculating Evaporative Cooling Evaporating Cooling System Installation End Panel Installation Install the End Panels flush with the inside of the opening (at both ends).. Locate the top mounting hole (in the flange of the Upper End Panels) on the chalk line. This will properly align the hole for the Distribution Pipe with the Pipe Hangers. See Figure. Secure the Upper End Panels to the top stringer using the 0x-/4'' Screws, as shown in Figure.. The Lower End Panels should overlap on the outside of the Upper End Panels to provide proper watershed. 3. Align mounting holes in the upper and lower end panels and secure the end panels to the frame using the 0x-/4'' Screws. 3 Chalk Line on top stringer 0 x -/4'' S.S. Screw 3 Upper End Panel 4 Lower End Panel 4 MV98-B /99 Figure. End Panel Installation 5

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Distribution Pipe Installation. Set a Distribution Pipe on the Pipe Hangers above the inlet end of the Trough. Note: The belled end must be away from the sump end. See Figure 3.. Assemble the Distribution Pipes by inserting the straight end of one pipe into the belled end of another. It is not necessary to glue the Distribution Pipes together. IMPORTANT: The spray holes, in the Distribution Pipes, MUST all be aligned and pointing straight up. 3. Verify that the spray holes are in alignment, then install a #0 x /'' S.S. Screw at each bell to secure the pipes together. 4. At the Sump End of the system the Distribution Pipe should extend 8"[0.3 cm] beyond the edge of the End Panel (See Figure 3, Item 9.) The Pipe should extend past the opposite End Panel. 5. Install a /4 x /'' Screw in each spray hole that falls outside the End Panels (at either end).. Bleed-Off Valve and sediment trap installation: At the end of the Distribution Pipe, opposite the sump end, install the PVC fittings as shown in Figure 3. Use two pieces of -/" PVC pipe cut "-" long. For systems with the Sump in the center of the system, Bleed-Off Valve fittings are installed only at one end of the Distribution Pipe. 7. Bleed-Off Hose: Route the Bleed-Off Hose (Figure 3, Item 8) to a drain for waste water. Do not run the Bleed-Off Hose back into the Trough. 0 0 3 4 4 9 5 5 7 MV98-0 /00 Figure 3. Distribution Pipe Installation 8 5 7 3 8 #0 x /'' S.S. Screw 5' Distribution Pipe 3 -/'' Mechanical Gripper Plug 4 Framing 5 Upper End Panel (L.H.) Upper End Panel (R.H.) 7 Lower End Panel (L.H.) 8 Lower End Panel (R.H.) 9 8" [0.3 cm] Approximately at Sump end 0 /4 x /" Screw " x -/" PVC Tee -/" PVC Pipe Sediment Trap 3 Adapter, " PVC SPIG x FIPT 4 Plug " PVC MPT 5 Bushing Reducer -/" x 3/4" 3/4" Water Bleed-off Valve 7 Hose Barb Cap 8 /4" Bleed-off Hose

" Recirculating Evaporative Cooling Evaporating Cooling System Installation End Panel Support Installation Install the End Panel Support using #0 x -/4 screws, as shown Figure 4. The End Panel Supports hold the End Panels perpendicular to the Top Stringer. Figure 4. End Panel Support Installation Pad Support Installation Set the Pad Supports on the Trough Supports, as shown in Figure 5. The front edge of the Trough should be captured inside the cavity on the front of the Pad Support. Butt the Pad Supports end to end, beginning at one End Panel. It may be necessary to trim the length of the last Pad Support. The Pad Supports should extend to both End Panels. Note: Sump components and End Panels not shown for clarity. MV44-030 08/00 Pad Support Pad Supports butted together 3 Trough 4 Front edge of Trough Figure 5. Pad Support Installation 7

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Caulking of End Panel Fill the joint at the rear of each end panel with caulking (not supplied) as shown in Figure below. Caulk MV98-37 0/99 Figure. Caulking of rear joint of end panel 8

" Recirculating Evaporative Cooling Evaporating Cooling System Installation Evaporative Cooling Pad and Cover Installation Beginning at one end, set the Evaporative Cooling Pads on the Pad Supports. See Figure 7. The top of the Pads should be against the Splash Plate and directly below the Distribution Pipe. Make sure the Pads are properly oriented. MUNTERS and GENERAL SHELTERS Pads: Refer to the directional arrows on the side of the pads. GLACIER COR Pads: May have a black stripe which indicates the bottom end of pads and the air inlet side of the pads. If no stripe is present, refer to Figure 8 to determine the proper pad orientation based on the direction of the pad flutes vs. direction of incoming air flow. Make sure the first pad is against the End Panels. Push Pads tightly together and keep as vertical as possible. Munters Pad and General Shelters Glacier Cor Pad Figure 7. Pad Installation MV98-7/98 MV438-5 /9 Figure 8. Pad Orientation (cut-away view of side of Pad) 9

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Cooling Pad and Cover Installation Continued... Set the Covers on the Pipe Hangers, as shown in Figure 0, Step. Slide the Cover Locks onto the Pipe Hangers, as shown in Figure 0, Step. If a hole in the Distribution Pipe aligns with a seam between covers install a Jet Deflector over the hole as shown in Figure 9. Repeat steps -3 until all the Evaporative Cooling Pads are installed. The Covers should butt end to end. The Evaporative Cooling Pads may be trimmed as required using a handsaw, to fit inside the End Panels. MV98-39 0/99 3 Figure 9. Jet Deflector Jet Deflector Distribution Pipe 3 Cover Step Step 4 3 Cover Distribution Pipe 3 Evaporative Cooling Pad 4 Cover Lock MV438- /9 Figure 0. Cover and Cover Lock Installation 0

" Recirculating Evaporative Cooling Evaporating Cooling System Installation Cooling Pad and Cover Installation Continued... If the last Cover is too long, trim the Cover as shown in Figure and overlap it with the previous Cover. Use () 0x/" Screws to join the Covers together. MV438-3 4/97 Figure. Cover Trimming and Assembly Required Length of last Cover ''(5 cm) 3 Cutting line 4 #0 x /'' Screw 5 Cover

Evaporating Cooling System Installation " Recirculating Evaporative Cooling Trough End Insert Installation 3 0 9 9 5 7 /4" x 3-/" Clamp Bolt Lower End Panel 3 Trough End Insert 4 Trough 5 /4" x " Washer /4" x -/" Lag Screw 7 x Bottom Stringer 8 /8" Rubber Edge Trim 9 Clamp Strap 0 #0 x /" Screw 4"-" Trough beyond End Panel -/" Clamp Nut 8 MV44-07 08/00 4 Figure. Trough End Insert Installation On the Trough end opposite the Sump, cut off the Trough leaving 4"-" of Trough extending beyond the End Panel. Assemble the Trough End Insert assembly as shown in Figure. Be sure the Insert is centered on the Clamp Strap before tightening the Clamp Bolt. Install two #0 x /" Screws through the Clamp Strap into the Trough as shown in Figure, Item 0. Be sure the Screws are on the exterior side of the Trough End Insert. Screw the Trough to the x Bottom Stringer using a /4"x-/" Lag Screw and a /4"x" Washer. (Figure, Items 5 & )

" Recirculating Evaporative Cooling Evaporating Cooling System Installation Sump Components Installation Assemble the Sump Components as shown in Figure 3, beginning at the Pump. The lengths of -/'' PVC Pipe Item will vary depending on desired Valve height, pad height, etc. Use teflon tape on threads as required. Use PVC glue on slip connections. Attach an electrical plug (if not supplied) to the Sump Pump electrical cord. Note: Sump in Center For pumps with water level safety switch make sure the vent hose inside the electrical cord is not obstructed. Flush all dirt from the water supply lines. Install the Garden Hose to the water supply and connect to the inlet on the Sump. Sump on End 3 7 9 7 9 3 8 8 4 5 4 5 9 0 9 MV98- /00 0 -/ x x '' PVC Tee 0 Sump Pump Adapter, " PVC Sump 3 Plug " PVC Pipe MPT -/'' Mechanical Gripper Plug 4 -/" Union 3 Garden Hose to 3/4" Pipe Adapter 5 Water Level Adj. Hose Clamp 4 Water Supply Inlet Hose -/'' PVC Pipe 5 Sump Water Inlet 7 Strainer Float Valve 8 -/'' Ball Valve 9 -/'' PVC Adapter Figure 3. Distribution Pipe Installation 3

System Start-Up " Recirculating Evaporative Cooling System Start-Up. Partially fill Trough with water.. Flush dirt and debris from the Trough by removing the Sump Drain Plug. 3. Refill system with water. With the Hose Clamp loose, raise/lower the 3/4" Pipe to adjust the Initial Water Level. Check that the Float Ball is not rubbing against the side of the Sump. The Initial Water Level should be " -4" below the Mounting Screws in the back of the Sump. Retighten the Hose Clamp. (See Figure 3. Below) 8 7 4 5 3 "-4" [5mm-0mm] Initial Water Level 3 PVC Float Valve 4 Hose Clamp 5 3/4" PVC Pipe Sump 7 Sump Mounting Screws 8 Float Ball MV44-05 09/00 Figure 3. Adjusting Initial Water Level Note: After the system runs for a while and turns off the water level will rise.5-.0'' above the level it was initially set at. 4. Open the valve in the pump discharge pipe. 5. Flush dirt and debris out of the Distribution Pipe by running the Pump with the -/" Pipe Plug removed from the end of the Distribution Pipe. Replace the -/"' Pipe Plug.. With the Sump Pump running, adjust the -/" Ball Valve so the height of the water jets is 4" to " [0 mm to 5 mm] above the top of the Distribution Pipe. 7. If bleed-off is to be used, Adjust the Bleed Off Valve to a flow rate of 0.5 gpm per 00 sq ft. of Evaporative Cooling Pad. The correct amount of bleed-off depends on the amount of minerals and chemicals in the water. The bleed off rate can be adjusted over time, but should be maintained high enough to prevent mineral deposits from accumulating on the face of the Evaporative Cooling Pad. 4

" Recirculating Evaporative Cooling System Operation & Maintenance System Operation & Maintenance. Reduce the mineral and chemical build-up in water by; a). Bleeding water off the system. Begin by adjusting the Bleed-Off Valve to drain.5 gpm/00 sq ft. of Cooling Pad while the Pump is running. Increase the bleed-off rate if minerals build up on the face of the Cooling Pad b). Draining all the water from the system once a week during operating season. Increase the frequency if minerals build up on the face of the Cooling Pad.. Shade the pads as much as possible to minimize algae growth. 3. Allow the pads to dry out completely once every 4 hours to kill algae. 4. Reduce the number of times the pad is wetted and dried out each day to maximize pad life. 5. Clean the strainer regularly to maintain a sufficient supply of water to the pads.. Periodically check the jets of water from the top of the Distribution Pipe. The jets should spray approximately 4" to " [0 mm to 5 mm] straight upward. 7. Keep the Distribution Pipe holes free of debris. A 5/3" drill bit may be used to clean the holes or a large round brush may be attached to 3/4" pvc pipe and pushed through the Distribution Pipe to clean out the holes. The " Pipe Plugs at either end of the Distribution Pipe can be removed to allow cleaning brush access. Clogged holes may cause dry streaks and lead to clogging of the pad. 8. Every three months, the entire water system should be drained, disinfected and flushed to help prevent algae growth. 9. Regularly flush the Distribution Pipe by removing the.5'' plug at the end of the sediment trap (See Figure 3, Item ) and allowing the pump to run. 0. Periodically, gently hose and brush deposits from the face of the pads.. Completely drain the system for winter storage. Remove the Sump Drain Plug. Remove the Pump.. Avoid contaminants such as dust, fertilizers, and harsh cleaners. 3. The ph of the water being circulated through the system should be maintained at between and 9 to prevent premature pad softening. 4. Check that Cooling Pads are installed correctly. See Figure 9 through Figure. 5

Parts Lists and Kits " Recirculating Evaporative Cooling Parts Lists and Kits Sump Kit Part No. 4340 5 5 7 7 7 7 5 4 3 7 9 8 0 8 9 35 9 3 34 8 3 30 7 0 4 37 33 3 3 38 5 4 3 44-00 7/00 Part No. Qty Part No. Qty /4'' Black Bleed Off Hose 4454-44 0 -/'' Union 44040 Hose Barb Cap 4 Insert,Sump End 4033 3 3/4'' Bleed-off Valve 955 Insert, Trough End 4309 4 -/" x 3/4'' Reducer Bushing 387 3 Strap, Insert Clamp 400 5 -/ x " x " PVC Tee 447 4 SS 0 Mesh Screen 44 - -/" PVC Tee 388 5 Plug " PVC MPT 45749 7 Hose 354 Adapter " PVC Spig x FIPT 45748 8 Garden Hose to 3/4" Pipe Adp. 405 7 Bolt, /4-0 x 3-/ 4404-5 9 -/" Drain Plug 3847 8 -/" Clamp Nut 49 0 Turbo Cool Sump 4339 9 Screw, /4 x -/ Lag 45 3 -/" SS Hose Clamp 35 30 Washer, /4 x 955-5 3 Ball, Float 45985 3 Valve,PVC Float 45989 3 -/ x 4" Foam Tape 4708-3 Nut, /4-0 S.S. 745 4 Sump Support Bracket Assembly 4448 33 Rod, Float " 5 40 5 -/" PVC Adapter 387 3 34 Adapter, 3/4" PVC Female 80 -/" PVC Valve 44039 35 Adapter, 3/4" FS x FGHT 405 7* -/ x 5' PVC Pipe 3877 3 Pipe, 3/4" x 9-/" PVC 754-8 Strainer Assembly 3873 37 Strainer O-Ring 447-9 Trim, /8" Rubber Edge 430-38 PVC Valve Seal Kit 448 - * The 5' PVC Pipe is not supplied with the Sump Kit (Part No. 4340). It is included with the End Panel Kit (Part No. 448).

" Recirculating Evaporative Cooling Parts Lists and Kits Distribution Kit Part No s. 448-5 and 448-0 7 8 5 MV98-4 0/99 3 4 Part No. Qty 5' Qty 0' x 5' Distribution Pipe 4333 4 Cover Lock 3835 8 3 Pipe Hanger 3835 8 4 Trough Support 4345 4 5 Splash Plate 38357 4 Pad Support 4344 4 7 Evaporative Pad Cover 38355 4 8 Jet Deflector 445 4 -- /4 x -/'' SS Lag Screw 45 4 -- 0 x -/4'' SS Screw 3703 4 -- 0 x /'' SS Screw 383 4 -- /4" Drive Rivet 4597 4 *The 448-5 Distribution Kit includes appropriate components for a 5' evaporative cooling line. The 448-0 Distribution Kit includes components for a 0' evaporative cooling line. 7

Parts Lists and Kits " Recirculating Evaporative Cooling End Panel Kit Part No. 448 and Center Panel Kit Part No. 4345 4 5 5 3 4 7 3 9 8 0 MV44-00 07/00 Quantity Part No. End Panel Kit Center Panel Kit Evap. End Lower Panel (L.H.) 38733- Evap. End Upper Panel (L.H.) 3835-3 Evap. End Upper Panel (R.H.) 3835-4 Evap. End Lower Panel (R.H.) 38733-5 x 5' Distribution Pipe 4333 ---- -/ x 5' PVC Pipe 3877 ---- 7 End Panel Support 4439 8 " x " x -/" PVC Tee 447 ---- 9 -/" Drain Plug 3847 ---- 0 x 4" Foam Tape 4708- ---- Insert, Trough End 4309 ---- Insert, Sump End 4033 ---- 3 Strap, Insert Clamp 400 ---- 4 Nut, /4-0 Special 49 5 Bolt, /4-0 x 3-/ 4404-5 ---- Trim, /8" Rubber Edge 430- ---- -- 0 x /'' SS Screw 383 5* ---- -- 0 x -/4'' SS Screw 3703 3* 8 -- /4 x -/'' SS Lag Screw 45 7* ---- -- /4" Drive Rivet 4597 5 ---- -- /4 x /" Screw 9 5* ---- *Includes at least 5 extra pieces to cover any lost hardware. 8

" Recirculating Evaporative Cooling Parts Lists and Kits Miscellaneous Components 3 MV44-0 07/00 Part No. ** Pump (see chart on page ) ----------- * PP Black Trough 4" wide with holes 4044-X 3 Cooling Pads: Munters Celdek 45 /5 " x " x 3 foot " x " x 4 foot " x " x 5 foot " x " x foot 3** Cooling Pads: Glacier Cor 45 /5 " x " x 3 foot " x " x 4 foot " x " x 5 foot " x " x foot 3 Cooling Pads: General Shelters 45 /5 " x " x 3 foot " x " x 4 foot " x " x 5 foot " x " x foot 3 Cooling Pads: Munters Mi-T Cool 45 /5 " x " x 3 foot " x " x 4 foot " x " x 5 foot " x " x foot 384-3 384-4 384-5 384-3875-3 3875-4 3875-5 3875-4389-3 4389-4 4389-5 4389-3875-3 3875-4 3875-5 3875- Part Numbers listed are for pads with coating on inlet side, shipped from Milford *Round up to the nearest 5' Trough lengths are available from 5' to 40' Example: 4044-00 is a 0' roll of Trough, 4044-50 is a 5' roll of trough. **Add a "D" to the part number (xxxxx-3d) for drop shipped pads Add a "N" to the part number (xxxxx-3n) for pads without coating on the inlet side Add a "B" to the part number (xxxxx-3b) for pads with coating on the inlet and bottom side of the pad 9

Parts Lists and Kits " Recirculating Evaporative Cooling This Page Left Blank for Notes: 30

" Recirculating Evaporative Cooling Parts Lists and Kits This Page Left Blank for Notes: 3

Parts Lists and Kits " Recirculating Evaporative Cooling Made to work. Built to last. Revisions to this Manual Page No. Description of Change Contact your nearby Chore-Time distributor or representative for additional parts and information. CTB Inc. P.O. Box 000 Milford, Indiana 454-000 U.S.A. Phone (9) 58-40 Fax (877) 730-885 E-Mail: ctb@ctbinc.com Internet: http//www.ctbinc.com Printed in the U.S.A. 3