RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Similar documents
RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

GTS 15/25/40/50/60/75/90/120A

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

RVS-AX Instruction Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

A6Z OPERATING MANUAL

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

Temperature Controllers

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

1 Phase electronic contactor (SC 1)

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Temperature Controllers

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

J TS 7090 Thyristor power switch

A3Z OPERATING MANUAL

SCR Power Controllers

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

SECTION MOTOR CONTROL

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Model Number Structure

PSU EN54-4 Power Supplies

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Solid State Relays contactor with Integrated Fuse Type RGC1F

Features. Description. Table of Contents

This manual is to be given to the end user. Eur en / e. Remote speed reference input. Remote current speed reference input (A1)

DEEP SEA ELECTRONICS PLC

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

Phoenix Inverter

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

A1P OPERATING MANUAL

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Power Switching Principles

The High Power Stack Horizon

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

EPS/ELA-Series User Manual EPS/ELA 250W

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

MODEL ELC-12/60-D BATTERY CHARGER

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

Application example of a motor controlled by MCD100 and protected by a circuit breaker

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

SOLSTART Instruction Manual

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

1.1 Caution Statements

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

EC400 Power Control System

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

INSTRUCTION MANUAL (ATEX / IECEx)

1SVC F SVC F 0607 R100.20/30 R100.45

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Professional Wireless Products

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

INTECH Micro 2300-RTD6

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Temperature Controller (Heat Pumps)

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Zero Cross Over Turn On Thyristor Switch Card for Capacitor Bank

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Instruction Manual. Q Series 2 Motor Control Modules - OEM

GS-AQ1000 VOC Indoor Air Quality Sensors

KD LV Motor Protection Relay

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Thyristor power units TC3000. Three-phase load control. User Manual

Installation Instructions

HIB Enclosed Inverter User Guide

GTS-L4 5 / 10 / 15 TECHNICAL DATA

Three-Phase Soft Starters

Design Guide. VLT Soft Start Controller MCD 100

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

SDS Enclosed Star-Delta Starter User Guide

24V 3A EN54 Ancillary Power Supply

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

CD3000S-1PH Thyristor Unit Heater Break version

Combined Ventilation Controller RVWS-T-224HA

Transcription:

Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient electronic switching No additional heat sinks required Technical Overview The RE-PR3-E-86 & RE-PR3-E-105 thyristor control assembly s provide full seamless control of 3-phase resistive loads up to 86kW and 105kW, using two thirds control technique. They are controlled by a 0-10Vdc, 0-5Vdc, 4-20mA or manual potentiometer signal. These burst fire control assemblies use fast pulse, zero volt, switching technology to minimise flicker and eliminate RFI problems. They also incorporate a temperature trip, automatic reset, alarm output, LED output on indication and heatsink. Applications include electric heater batteries and duct heaters.

Page 2 of 6 Specification: Input signal 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer Supply (control)* 24Vac/dc ±10% Supply (load) 3-Phase 400V RMS ±10% 50/60Hz Power / current ratings: 86kW 119A per phase 105kW 146A per phase Fusing High speed semiconductor type ferrule fuse (integral): 86kW 106 EET (160A) 105kW 200 EET (200A) Terminal connections: Auxiliary alarm Rising cage for 2.5mm² cable Control Rising cage for 2.5mm² cable Power M6 Stud Earth M6 Stud Torque settings 4.5 to 5Nm Status indicator (tracking control signal) LED changes intensity Over temperature: Trip in temp. @ 90 C (194 F) ±1 C (1.8 F) Trip out temp. @ 85 C (185 F) ±1 C (1.8 F) Fault condition Relay rated at 125Vac @ 2A Fault status: Phase loss LED flashes, continuous slow pulsing Sensor loss LED flashes, on/off fast pulsing Ambient temperature 65 C (149 F) (maximum) Fixing centres (W, D) 4 x 6mm (0.24 ) on centres 322 x 200mm (12.68 x 7.87 ) Dimensions (L, W, H) 340 x 232 x 124mm (13.39 x 9.13 x 4.88 ) Conformity CE Marked Country of origin UK Part Codes: RE-PR3-E-86 86kW, 120A Per Phase, Panel Mount Heating Regulator RE-PR3-E-105 105kW, 146A Per Phase Panel Mount Heating Regulator Accessories RE-PR3-F11606 Replacement fuse for RE-PR3-E-86 RE-PR3-F11610 Replacement fuse for RE-PR3-E-105 The products referred to in this data sheet meet the requirements of EU 2004/108/EC and 2006/95/EC * PLEASE NOTE They are factory set for an internal 24V supply, if an external supply is used the dip switch SW4 must be changed before power-up.

Page 3 of 6 SAFETY REQUIRMENTS & ADVICE SHEET Introduction The objective of this leaflet is to provide information to ensure that the safety of the person(s) installing or maintaining the equipment is not compromised and its location and method of installation does not endanger others, either during or after installation. Customers should be aware of the Health and Safety at Work Act 1974 (HSW 1974) and the EC Provision and Use of Work Equipment Regulations 1992 (PUWER). Both are available from the Health and Safety Executive (HSE) publications, within the UK. Installation CE Directives These are European regulations which apply to our industry. They affect the equipment emissions and immunity to Radio Frequency Interference (RFI) and various elements of safety for electrical equipment. The European Community CE Directives that mainly concern Sontay Ltd are the Low Voltage Directive (LVD) and the Electromagnetic Compliance Directive (EMC). A Declaration of Conformity may be supplied with the product or supplied on request. Torque Settings Good working practises must be adhered to ensuring appropriate electrical and mechanical installation. This would include the mechanical fixing of potentiometer bushes and electrical set screw and/or pillar connections. These Electrical Connections and Mechanical Fastenings must not be over tightened. We would recommend a typical torque setting of 1 to 5Nm. For specific product information, see appropriate product data sheet, where applicable. Cooling Requirements The use of an additional heatsink (this could be a conductive panel) suitably attached or mounted with the unit, will help to dissipate heat away from the device(s). An alternative or additional method would be forced air-cooling (using a fan), to assist the natural convection of airflow over an existing heatsink within the unit. The product fins should be mounted in line with the forced and/or natural airflow. The equipment s environment and its initial ambient temperature also need to be considered, as this could have an adverse effect on the overall operating conditions. Fusing We recommend that semiconductor, fast acting to BS88 IEC 269, type fuses or circuit breakers (Semiconductor - MCB) should be used for unit and/or device protection. The appropriate maximum load current should be known to elect the required SCR fuse or Z curve MCB, but must not exceed the equipment rating. The I² t (A² s) rating of the selected fuse must be less than that of the equipment so as to protect the equipment s discrete device. Further appropriate fusing may be required for protection of the unit supply using standard fuse links and holders. Failure to address these requirements and the use of incorrectly selected fuses may cause the equipment to fail. Earthing The protective conductor terminal of the equipment must be utilised at all times and bonded to a good Earth (ground). The earth bonding (strapping) leads of any combined equipment should be as short as possible and be substantial, i.e. at least rated higher than the equipment s load. For further information, refer to BS7671. Following these simple guidelines will ensure optimum use of any appropriate filter circuits which may be required. Insulation (over-voltage category) and Protection from electric shock Classification of Equipment All equipment, unless otherwise stated, is rated to CLASS II Insulation (Over-voltage category) and CLASS I (Protection category). Maintenance Before any servicing is carried out, reference should be made to appropriate installation instructions, drawings and labelling which may come with the equipment. Personnel should switch off the unit supply before accessing or removing any safety cover and be aware of hazardous live parts.

Page 4 of 6 Location & Ventilation: The power controller is designed for mounting on a vertical panel, with the heatsink fins to the bottom. It is important that free air movement around the heatsink is not restricted. Allow sufficient air space between adjacent units to allow optimum performance of the heatsink. The maximum ambient of 65 C (149 F) should not be exceeded. Where necessary control panels & enclosures should be ventilated with a fan. Considerations: Both controllers are designed for 3-wire, 3-phase floating-star or closed delta configured resistive loads. It is a 2-leg thyristor controller and therefore unsuitable for 4-wire, 3-phase with star point to neutral configured loads. Unusual heating loads such as Molybdenum, Platinum or Tungsten have a typical, 10:1, hot to cold, resistance ratio and therefore, when cold, draw larger currents than normal. Over Temperature Monitoring: They are fitted with a thermal protection device to protect against over temperature. The unit will automatically switch off the load in the event of the heatsink temperature exceeding safe limits (90 C (194 F) ±1 C (1.8 F)). Once the temperature has fallen to a safe level (85 C (185 F) ±1 C (1.8 F)) the load will be switched on again if the supply is still present. Under normal operating conditions the heatsink will not reach 90 C (194 F) but this might occur, for example when the ambient temperature exceeds 65 C (149 F). Caution: During the course of normal operation metal parts, in particular the heatsink may get very hot. Control Supply: Factory set for an internal 24V power supply. If using an external 24Vac/dc supply you must change the DIP switch SW4 on the PCB prior to applying power. This is polarity independent. If there is a requirement for the alarm relay and LED to energise when any of the 3 phases fails, the external, isolated 24Vac/dc supply option must be used. Earth Connection, Back Up Protection & Supply: The RE MUST be earthed. A protective earth connection is provided in the main terminal connections. Both controllers are protected by internal quick acting semiconductor type fuses. cables must be sized such that they are rated in excess of the fuse ratings. It is recommended that a load break switch and a contact breaker is installed in the load supply. The supply to the contactor coil should be interrupted by an over-temperature thermostat located in the heater battery and also upon detection of airflow loss.

Page 5 of 6 Fault Conditions, Phase Loss with Auxiliary Supply: The factory default setting of DIP switch SW1 is the ON position. In this position, the alarm relay will be energised only when a fault condition occurs. Changing SW1 to the OFF position will cause the alarm relay to be energised continuously until a fault condition occurs. If the internal 24V supply is used, a fault condition will occur on over temperature or if the L1 phase only is missing. If an external 24V supply is used, a fault condition will occur on over temperature, temperature sensor failure, or if any of the 3 phases are missing. Should the 24V supply fail the output of the unit will fail to OFF with no output. When any one of the three phase inputs are missing, the relay changes state and the LED flashes ON/OFF bursts of 1.5 seconds. Note - This is only true when using an external 24V supply. When using an external supply the 3-phase power must be turned on before the external (24V) control supply. If the control supply is turned on first, then it will go into phase failure, due to the 3-phase being off. Alarm Relay: Where the internal 24V supply is used, the relay obtains its supply from the transformer via two 20mm 1A fuses, and are connected to the L1 and L2 phases. Therefore the alarm relay can only change state when there is an over-temperature condition, a sensor fault, or if the L3 phase only is missing. Alarm contacts are rated up to 2A @ 125Vac (RMS) load. Manual Control: The units output can be controlled manually by using a 5kΩ linear potentiometer connected as shown on page 6, with the input signal set to 5Vdc (SW3). Note: A 5kΩ linear potentiometer MUST NOT be connected at same time as an external control signal. 4-20mA Input Signal: For input current signal of 4-20mA, set DIL switch SW-I/V to ON, fit a 270Ω, 0.25W resistor across the + and - signal terminals and set SW3 to 0-5V. Note: For 4-20mA signal, a 270Ω resistor is supplied (stuck to underside of cover). Factory-set default setting is 0-10V. Dip Switch Settings: SW1 (relay status): SW2: ON = Standard ON = Fast burst (standard) OFF = Reverse OFF = Slow burst SW3 (control signal): SW4 (remote supply): ON = 0-5Vdc INT = Uses internal transformer (standard) OFF = 0-10Vdc (standard) EXT = External 24V supply

Page 6 of 6 Connections: Star configuration: Delta configuration: WARNING! Do NOT connect the neutral to the star point of heater. Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.