1B filter, RFI 1 B/LC filter. VLT 2800 Motorcoil, RFI

Similar documents
FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Distributed intelligence

5. Installation on Pedestal - IP 21 / IP 54 Units 43

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

GMM. Intelligence for condensers and drycoolers with AC fans. Güntner Info. sincon

CI-TI Contactors - VLT Frequency Converters

Brake Resistor Design Guide. How to Read this Design Guide 3 Abbreviations 4. Safety Precautions 5 CE Conformity and Labelling 5

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

Installation Guide VLT Parallel Drive Modules

USERS MANUAL MCD REMOTE OPERATOR

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

LED Driver Linear / area dimming

VLT AutomationDrive FC Pulse Instruction Manual VLT AutomationDrive FC 300

Instruction Manual. VLT AutomationDrive FC 300

VLT HVAC Drives Technical Reference Supplement

Appendix: Safety and application notes for... 15

Operating Instructions. Drives Solutions.

MAKING MODERN LIVING POSSIBLE. Instruction Manual. VLT AutomationDrive FC 300, kw

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

MAKING MODERN LIVING POSSIBLE. Instruction Manual VLT AutomationDrive FC 300

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

2 Safety Instructions and General Warning 2-1

MCW Application Notes 24 th August 2017

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

VLT 8000 AQUA. Compact IP 54/NEMA 12 VLT V VLT V. MG.80.A VLT is a registered Danfoss trademark

%BUB4IFFU. 3-line sine-wave EMC output filters for converters and power electronics SineFormer 520 V AC, A, 40 C. Date: November 2007

MCD 200 Series Soft Starters

LED Driver Linear / area fixed output

DBR3, 4500W, 9R, TS - BRAKING RESISTOR

Number 1 in efficiency

1.1 Caution Statements

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

DEVICE STATE/BYPASSED FAILURE OVERLOAD

MAKING MODERN LIVING POSSIBLE. Service Manual VLTp Soft Starter - MCD500 *MG17L402*

Design Guide VLT HVAC Drive FC 102

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

1329I Integrated Drive/Motor CE Filter Option Kit

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

VLT AutomationDrive for marine winch applications

Design Guide VLT HVAC Drive FC 102

Power Supply EL

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Design Guide VLT AutomationDrive FC 302

Pressure transmitter for industrial applications Type MBS 4500

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

VTZ variable speed Reciprocating compressors

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

High Frequency SineWave Guardian TM

Section 1.0. Section 2.0. Section 3.0. Section 4.0. MCD3000 Series. Contents. Warnings... 3

Appendix: Safety and application notes for 19

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

Installation Instructions

MCD Pump Application Module

Shipping volume [ft 3 ] 3 SQF-2 47 * 2.9 1" NPT Dimensions [in] L B S 3 SQF-3 49 * 2.9 1" NPT

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

RVS-AX Instruction Manual

Battery Power Inverters

M Technical Specification No. for the supply of Battery Charger. Israel Railways Ltd. Rolling Stock Division

L300P Inverter Specifications

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

Operating Instructions

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

USER MANUAL MPS 1-5KW SERIES

PURE SINE WAVE DC TO AC POWER INVERTER

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Contents. MCD 200 Design Guide. Contents

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Technical Journal September 2012

Variable speed application guidelines

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Number 1 in efficiency

Motor Protection With The MonitorPro

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Table of Contents. VLT 5000 Series Service Instructions. Introduction Product Overview Warnings and Cautions... 1

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

For Operation in the Control Cabinet

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Phoenix Inverter

Application Engineering

DYNEO Synchronous motors with permanent magnets-drive Commissioning

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

vacon nx ac drives brake resistors user manual

Electronic Ballast EVG 2000-T

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Transcription:

High voltage warning The voltage of the frequency converter is dangerous whenever the equipment is connected to mains. Incorrect installation of the motor or frequency converter may cause damage to the equipment, serious injury or death. Comply with the instructions in this manual, as well as national and local rules and safety regulations. Touching the electrical parts may be fatal - even after the equipment has been disconnected from mains: Wait at least 4 minutes for current dissipate. It is the responsibility of the user or installer to ensure correct earthing and protection in accordance with national and local standards. These rules concern your safety 1. The frequency converter must be disconnected from the mains if repair work is to be carried out. Check that the mains supply has been disconnected and that the prescribed time has passed before removing motor and mains plugs. 2. The [STOP/RESET] key on the control panel of the frequency converter does not disconnect the equipment from mains and is thus not to be used as a safety switch. 3. The unit must be properly connected to the earth, the user must be protected against the supply voltage and the motor must be protected against overloading pursuant to prevailing national and local regulations. 4. The earth leakage currents are higher than 3.5 ma. 5. Protection against motor overload is not included in the factory setting. If this function is required, set parameter 128 Motor thermal protection to data value ETR trip or data value ETR warning. For the North American market: The ETR functions provide overload protection of the motor, class 20, in accordance with NEC. 6. Do not remove the plugs for the motor - and mains supply while the frequency converter is connected to mains. Check that the mains supply has been disconnected and that the prescribed time has passed before removing motor and mains plugs. 7. Note that the frequency converter has more voltage inputs than L1, L2 and L3 when the DC bus terminals are used. Check that all voltage inputs are disconnected and that the prescribed time has passed before repair work is commenced. Warning against unintended start 1. The motor can be brought to a stop by means of digital commands, bus commands, references or a local stop, while the frequency converter is connected to mains. If personal safety considerations make it necessary to ensure that no unintended start occurs, these stop functions are not sufficient. 2. While parameters are being changed, the motor may start. Consequently, the stop key [STOP/RESET] must always be activated, following which data can be modified. 3. A motor that has been stopped may start if faults occur in the electronics of the frequency converter, or if a temporary overload or a fault in the supply mains or the motor connection ceases. VLT 2800 Motorcoil, RFI 1B filter, RFI 1 B/LC filter MI.28.B1.02 - VLT is a registered Danfoss trademark 1

Motor coils By fitting the motor coil module between the frequency converter and the motor it is possible to use up to 200 metres of unscreened/unarmoured motor cable or 100 metres of screened/armoured motor cable. The motor coil module has an enclosure of IP 20 and can be installed side-by-side. To have long motor cables and still comply with EN55011-1A, motor coil and EMC filter for long motor cables are needed. To comply with EN55011-1A the EMC filter for long motor cables can only be fitted to a VLT 2800 with integral 1A filter (R1 option). See also the section EMC Emission. Technical data for VLT 2803-2875 Motor coils Max. cable length (unscreened/unarmoured) 1) 200 m Max. cable length (screened/armoured) 1) 100 m Enclosure IP 20 Max. rated current 1) 16 A Max. voltage 1) 480 V AC Min. distance between VLT and motor coil Side-by-side Min. distance above and below motor coil 100 mm Mounting Vertical mounting only Dimensions H x W x D (mm) 200 x 90 x 152 Weight 3.8 kg 1) Parameter 411 Switching frequency = 4500 Hz. 2 MI.28.B1.02 - VLT is a registered Danfoss trademark

RFI 1B filter All frequency converters will cause electromagnetic noise in the mains supply when they are operating. An RFI (Radio Frequency Interference) filter will reduce the electromagnetic noise in the mains supply. Without an RFI filter there is a risk that a frequency converter will disrupt other electrical components that are connected to the mains and might thus cause operating disruption. By fitting an RFI 1B filter module between the mains supply and the VLT 2800, the VLT 2800 complies with the EMC norm EN 55011-1B. To comply with EN 55011-1B the RFI 1B filter module must be fitted together with a VLT 2800 with integral 1A RFI filter. VLT 2800 Motorcoil, RFI 1B filter, RFI 1 B/LC filter Technical data for VLT 2803 2875 RFI 1B filter Max. cable length (screened/armoured) 200-240 V 100 m (At 1A: 100 m) Max. cable length (screened/armoured) 380-480 V 25 m (At 1A: 50 m) Enclosure IP 20 Max. rated current 16 A Max. Voltage 480 V AC Max. voltage to earth 300 V AC Min. distance between VLT and RFI 1B filter Side-by-Side Min. distance above and below RFI 1B filter 100 mm Mounting Vertical mounting only Dimensions H x W x D (mm) 200 x 60 x 87 Weight 0.9 kg MI.28.B1.02 - VLT is a registered Danfoss trademark 3

RFI 1B/LC filter To comply with EN 55011-1B the RFI 1B filter module must be fitted to a VLT 2800 with integral 1A RFI filter. The 1B/LC filter is not suitable for 200 V devices due to the high 1Ø input current. Technical data for VLT 2803 2875 RFI 1B/LC filter Max. cable length (screened/armoured) 380-480 V 25 m (At 1A: 50 m) Enclosure IP 20 Max. rated current 4.0 (Order no.: 195N3100); 9.1 (Order no.: 195N3101) Max. voltage 480 V AC Max. voltage to earth 300 V AC Min. distance between VLT and RFI 1B/LC filter Side-by-Side Min. distance above and below RFI 1B/LC filter 100 mm Mounting Vertical mounting only Dimensions 195N3100 4.0 A H x W x D (mm) 200 x 75 x 168 Dimensions 195N3101 9.1 A H x W x D (mm) 267.5 x 90 x 168 Weight 195N3100 4.0 A 2.4 kg Weight 195N3101 9.1 A 4.0 kg 4 MI.28.B1.02 - VLT is a registered Danfoss trademark

RFI 1B/LC filter The RFI 1B/LC filter contains both an RFI module that complies with EN 55011-1B and an LC filter that reduces the acoustic noise. LC filter Installation of thermistor (PTC) The RFI 1B/LC filter has an integral thermistor (PTC), which is activated if an overtemperature arises. The frequency converter can be programmed to stop the motor and activatee an alarm via a relay output or a digital output if the thermistor is activated. VLT 2800 Motorcoil, RFI 1B filter, RFI 1 B/LC filter When a motor is controlled by a frequency converter, at times you will be able to hear the acoustic noise from the motor. The noise, which is caused by the design of the motor, is generated every time one of the inverter contacts in the frequency converter is activated. The frequency of the acoustic noise therefore corresponds to the frequency converter's connection frequency. The filter reduces the voltage's du/dt, the peak voltage Upeak and ripple current ΔI to the motor, so that the current and voltage are almost sine-shaped. The acoustic motor noise is thus reduced to a minimum. Because of the ripple current in the coils some noise will be emitted by the coils. This problem can be solved completely by fitting the filter inside a cabinet or equivalent. The thermistor must be connected between terminal 50 (+10V) and one of the digital inputs 18, 19, 27 and 29. In parameter 128 Motor thermal protection, Thermistor warning [1] or Thermistor trip [2] are selected The thermistor is connected as follows: Danfoss can supply an LC filter for the VLT series 2800, which muffles the acoustic motor noise. Before the filters are put into use you must ensure that: - rated current is observed - mains voltage is 200-480 V - parameter 412 Variable switching frequency is set to LC filter attached [3] - output frequency is max. 120 Hz See drawing on the next page. MI.28.B1.02 - VLT is a registered Danfoss trademark 5

LC filter modules When the speed of a motor is controlled by a frequency converter, resonance noise from the motor will occur occasionally. This is due to the construction of the motor and the noise occurs whenever one of the inverter switches of the frequency converter is activated. The frequency of the resonance will therefore correspond to the switching frequency. The filter reduces the voltage rise time du/dt, the peak voltage Upeak and the ripple current ΔI to the motor. So the current and the voltage are near sinusoidal. That reduces the acustic motor noise to a minimum. Because of the ripple current in the coils there will be some noise from the coils. However, if the filter is built into a cabinet or the like the coil noise will be no problem. For the VLT 2800 Series, Danfoss can offer an LC filter which damps the acustic motor noise. To use the filters properly, it must be ensured that: - they fit the VLT frequency converter - the current ratings are observed - the mains supply is 200-480 V - par. 412 Output frequency dependent switching is set to LC-filter fitted [3] - the output frequency is max. 120 Hz The application of Automatic Motor Tuning (AMT) is limited, if an LC filter is installed. Par. 411 Switching frequency will be set to 4.5 khz after selecting LC-filter fitted [3] in par. 412 Output frequency dependent switching. Code Nos. for LC filter modules Mains supply for 3 x 200-240 V LC filter for VLT type Rated current at 230 V Max. output frequency Code no. 2803-2805 4.0 A 120 Hz 195N3100 2807-2815 9.1 A 120 Hz 195N3101 Mains supply for 3 x 380-480 V LC filter for VLT type Rated current at 400 V Max. output frequency Code no. 2805-2815 4.0 A 120 Hz 195N3100 2822-2840 9.1 A 120 Hz 195N3101 6 MI.28.B1.02 - VLT is a registered Danfoss trademark