Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Similar documents
Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SUNC3000 / Item #40885

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Submersible Effluent Pump

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ESE Series Cast Iron Sewage Pumps

Submersible Sewage Ejector Pump

SUBMERSIBLE SUMP PUMPS

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SUBMERSIBLE SUMP PUMPS

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

ON-SITE WASTEWATER PRODUCTS

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Sump / Effluent Pump

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

Submersible Solids Handling Pumps

GARDEN HOSE UTILITY PUMP

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Installation Manual. Q Series Quadplex Grinder Systems. Contents

OBE, OBEXU, ON BOARD Battery Chargers

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

Ion Technologies WC33 Submersible Sump Pump

Submersible Sump / Effluent Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

SUPER PUMP OUT SYSTEM

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

HALLMARK INDUSTRIES INC

OBAE, OBAEXU, ON BOARD Battery Chargers

INSTALLATION & OPERATION MANUAL

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

StormPro BA Series Sump Pump

QSSE, QSSEX INDUSTRIAL Battery Chargers

Matala. VersiFlow Series. Instruction and Maintenance Manual

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

2460 / 2472 / Series Simplex Grinder Systems

ME3F, ME3H Series. OWNER S MANUAL Submersible Sump / Effluent Pump 293 WRIGHT STREET, DELAVAN, WI PH:

Submersible Sump / Effluent Pump

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

M-3025CB-AV Fuel Pump

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

QPET, QPETXU Battery Chargers

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

StormPro BCV400 Sewage Ejector Pump

Ion Technologies ES45 Effluent Pump

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Installation & Operating Manual

Owner s Manual Drill and Light Weight Portable Utility Pumps

SHALLOW WELL JET PUMP

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Powerful & Intelligent Submersible Pumps

SUBMERSIBLE PUMP HSE RANGE

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

STAR STOP SHALLOW WELL JET PUMP

Portable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph

GeyserMax-Flow Series

STOCK No. 53DH04 MODEL 6EC-CIA-SFS STOCK No. 53DH05 MODEL 6EC-CIM STOCK No. 53DH06 MODEL 10EC-CIA-SFS. Installation Guide

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE MINI-PUMP

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

SUBMERSIBLE SWIMMING POOL DRAINER

3/4 HP SUBMERSIBLE SUMP PUMP

Model E75STVT. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

THERE IS NO OTHER EXPRESS WARRANTY.

STEP-BY-STEP INSTALLATION GUIDE

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SH30 High Head Effluent Pump

MODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP

PREINSTALLATION CHECKLIST

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Submersible Solids Handling Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Transcription:

OWNER S MANUAL Series: PFSWCPC75 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump ISP No: PFSWC75-8/1/15

General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information could cause serious bodily injury, death and/or property damage. Each Power-Flo pump is individually factory tested to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service. IMPORTANT - Power-Flo Pumps and Systems is not responsible for losses, injury or death resulting from failure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death. before servicing. ALWAYS disconnect the power to the pump Release all pressure and drain all water from the system before servicing any component. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before disconnect the power. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted. working with pumps. Wear safety goggles at all times when These units are designed for use on 115 volts or 230 volts (single phase), 60 Hz, and equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death. Ensure that the electrical circuit to the pump is protected by a 20 Amp - for 115V or 10 Amp for 230V, fuse or circuit breaker. Do not lift the pump by the power cord. Know the pump and its applications, limitations, and potential hazards. IMPORTANT! - Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure. IMPORTANT! - Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in. Ensure the electrical power source is adequate for the requirements of the pump. IMPORTANT! - This pump is made of highstrength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Power-Flo is a registered trademark of Power-Flo Technologies Inc. Alteration Rights Reserved. 3/15, 8/15 2

Features: Submersible sewage pump designed for typical raw sewage and typical septic tank/effluent applications. Specifications DISCHARGE: 2 NPT Male, Vertical LIQUID TEMPERATURE: 32-131 F MOTOR HOUSING: Cast Iron. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Cast Iron. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, Carbon/Ceramic/Stainless Steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: 115V - SJTW, 16AWG/3C Cord with plug, 230V - SJTW, 18AWG/3C Cord with plug MOTOR: Energy efficient Permanent Split Capacitor (PSC), Oil filled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments; 115V - 20 AMPS, 230V - 10 AMPS. LEVEL CONTROL: Vertical, Mechatronic, Normally Open (N/O), Reinforced thermoplastic, 115V-SJTW 16AWG/3C, 230V-SJTW 18AWG/3C, 10 Ft. cord with, Piggy-back plug, On-Off points are adjusteable, Attaches to discharge piping. WARRANTY: 3 year MODEL HP Hz Volts/Ph RPM FL AMPS Cord Length PFSWCPC75201451F10 3/4 60 115/1 1750 9.5 10 ft 32.3 lbs PFSWCPC75201452F10 3/4 60 230/1 1750 4.7 10 ft 32.3 lbs Submersible Sewage Pump 2 Discharge, 2 Spherical Solids Vertical Float Wt. HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft FLOW Gallon/Minute 145 125 100 65 FLOW Gallon/Hour 8700 7500 6000 3900 Max Lift Max Pressure 20 Ft 8.8 psi PF TYPE U, SP, SW Motor Housing P, C Impeller Type P, C Suction Plate Type P, C Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 15 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump P = Plastic C = Cast Iron P = Plastic C = Cast Iron P = Plastic C = Cast Iron 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 25 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 3

Performance & Dimensions Models: PFSWCPC75201451F10 PFSWCPC75201452F10 4

Features: Submersible sewage pump designed for typical raw sewage and typical septic tank/effluent applications. Specifications DISCHARGE: 2 NPT Male, Vertical LIQUID TEMPERATURE: 32-131 F MOTOR HOUSING: Cast Iron. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Cast Iron. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, Carbon/Ceramic/Stainless Steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: 115V - SJTW, 16AWG/3C Cord with plug, 230V - SJTW, 18AWG/3C Cord with plug MOTOR: Energy efficient Permanent Split Capacitor (PSC), Oil filled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments; 115V - 20 AMPS, 230V - 10 AMPS. LEVEL CONTROL: Wide Angle Tethered, Mechanical, Normally Open (N/O), Reinforced thermoplastic, 115V-SJOW 16AWG/2C, 230V-SJOW 18AWG/2C, 10 Ft. cord w/piggy-back plug, On point - 16.5, Off point - 8.7 WARRANTY: 3 year Submersible Sewage Pump 2 Discharge, 2 Spherical Solids Wide Angle Tethered Float MODEL HP Hz Volts/Ph RPM FL AMPS Cord Length PFSWCPC75201451T10 3/4 60 115/1 1750 9.5 10 ft 32.3 lbs PFSWCPC75201452T10 3/4 60 230/1 1750 4.7 10 ft 32.3 lbs Wt. HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft FLOW Gallon/Minute 145 125 100 65 FLOW Gallon/Hour 8700 7500 6000 3900 Max Lift Max Pressure 20 Ft 8.8 psi PF TYPE U, SP, SW Motor Housing P, C Impeller Type P, C Suction Plate Type P, C Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 15 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump P = Plastic C = Cast Iron P = Plastic C = Cast Iron P = Plastic C = Cast Iron 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 25 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 5

Performance & Dimensions Models: PFSWCPC75201451T10 PFSWCPC75201452T10 6

Pre-Installation APPLICATION This submersible sewage pumps and designed for pumping sewage, effluent, wastewater or flooded water with up to 2 inch solids. The pump is built with overload thermal protections and auto reset. The pump is equipped with a 3-prong grounding-type power cord and tethered or vertical float switch. This pump operates automatically. Ball bearings on motor shafts never need lubrication. TOOLS REQUIRED MATERIALS REQUIRED (NOT INCLUDED) Minimum Sump basin: 18 in. diameter, 30 in. depth 7

Installation INSTALLATION NOTICE: Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or gravel surfaces. Piping (2 or Less Solids) In any case, piping must not be smaller than pump discharge. When installed in a sewage system, pipe must be capable of handling semi-solids of at least 2 diameter. The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements, the minimum pipe size is 2. Use a 2 swing check valve in pump discharge to prevent backflow of liquid into sump basin. Check valve should be a free flow valve that will easily pass solids. NOTICE: For best performance of check valve when handling solids, do not install it with discharge angled more than 45 above the horizontal. Do not install check valve in a vertical position as solids may settle in valve and prevent opening on startup. Drill a 3/16 hole in discharge pipe about 1-2 above pump discharge connection (but below check valve) to prevent airlocking the pump. Electrical WARNING: Risk of electric shock. Can shock, burn or kill. When installing, operating, or servicing this pump, follow safety instructions listed below. Step 1. DO NOT splice the electrical power cord. Step 2. DO NOT allow electrical cord plug to be submerged. Step 3. DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or damage motor. Step 4. DO NOT handle or service pump while it is connected to power supply. Step 5. DO NOT remove grounding prong from plug or modify plug. To protect against electrical shock, the power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug pump into a 3-wire, grounded, grounding type receptacle. Connect pump according to electrical codes that apply. For automatic operation, plug pump into an automatic float switch or pump controller. Pump will run continuously when plugged directly into an electrical outlet. Connect or wire pump to an individual branch circuit with no other outlets or equipment in the circuit. AUTOMATIC - Plug the pump power cord plug into the piggy-back switch plug outlet, and then plug the switch plug into a 115V for 115 V (see Figure 1) or 230V for 230V (see Figure 2) GFCI power outlet for automatic operation. The pump will start operating if the float switch moves over the top of the pump. The water will be pumped out. When the water lowers to a certain level, the float switch will turn off the pump. MANUAL - Plug the pump power cord plug into a 115V for 115 V (see Figure 1) or 230V for 230V (see Figure 2) GFCI power outlet directly for manual operation. Pump will start operating once it is pluged into the GFCI outlet and water will drain out. When water is drained out, you must unplug the pump. 8

Operation Figure 1 - For 115 Volt Figure 2 - For 230 Volt Size fuses or circuit breakers according to chart below. Fuse Data MODEL HP VOLTAGE Individual Branch Cercuit Required (Amps) PFSWCPC75201451F10 PFSWCPC75201451T10 PFSWCPC75201452F10 PFSWCPC75201452T10 3/4 115 20 230 10 OPERATION NOTICE: Do not allow pump to run in a dry sump. It will void the warranty and may damage the pump. An automatic overload protector in the motor will protect motor from burning out due to overheating / overloading. When motor cools down, overload protector will automatically reset and start motor. If overload trips frequently, check for cause. It could be a stuck impeller, wrong/low voltage, or electrical failure in motor. If an electrical failure in the motor is suspected, have it serviced by a competent repairman. Pump is permanently lubricated. No oiling or greasing is required. 9

Operation General WARNING: Risk of electric shock. Can shock, burn or kill. Do not lift pump by power cord. Before removing pump from basin for service, always disconnect electrical power to pump and control switch. Submerge pump in a disinfectant solution (bleach) for at least one hour before disassembling pump. Put the pump upside down. Note: Pump is oil filled, to void the oil leakage don t incline the pump. Unscrew the stainless screws, and remove the volute/gasket. Use a flathead screwdriver to hold the shaft, then turn the impeller counterclockwise to release the impeller. Remove debris from around the shaft and on/under the impeller. Reassemble the pump. 10

Troubleshooting Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs. Symptom Possible Cause(s) Corrective Action Pump does not start or run Pump operates but pumps little or no water Pump starts and stops too often Pump will not shut off 1. The fuse is blow. 2. The breaker is tripped. 3. The plug is disconnected. 4. The plug is corroded. 5. Thermal overload. 6. Clogged impeller. 7. Motor failed 8. Float failed 9. Water level too low 10. Tangled switch 1. Debris caught in impeller or pipe 2. Check valve stuck or installed backward 3. Anti-airlock hole blocked 4. Impeller loose on shaft 5. Impeller broken 1. Backflow of water from piping, check valve leaking 2. Float switch failed 1. Defective float switch 2. Float obstruction 1. Replace the fuse 2. Reset the breaker 3. Secure the plug 4. Clean the plug prongs 5. Unplug for 30 minutes, then plug in 6. Remove the blockage 7. Replace pump 8. Replace switch 9. Pump will not turn on unless water level is over the pump cover and the float switch turns upside down 10. Reposition the pump and make sure switch moves freely 1. Clean out debris. 2. Inspect check valve and make sure it s properly installed 3. Remove the blockage 4. Reassemble impeller 5. Replace impeller 1. Replace check valve 2. Replace switch 1. Replace switch 2. Remove obstruction NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty. 11

3 YEAR WARRANTY Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, new pump product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of 3 years from date of sale. The date of sale shall be determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of the return is more than 3 years from the date of manufacturer. Product will be repaired, replaced or remanufactured at Manufacturer s option. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer s installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products. Contact Manufacturer at: 1-877-24PUMPS or www.powerflopumps.com, Attention: Customer Service Department, to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty. MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or con sequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 12