Adding Additional Gripper Circuits (SG3 & SG4)

Similar documents
Adding Additional Vacuum Circuits

N-084M and N-069M-DV Series Heat Exchanger Replacement

Electrical. The following slide shows the entire electrical overview. Take a moment to study the overview and become familiar with the components.

Pneumatic Manual 2008

ATTENTION. Custom Dynamics UTV Turn Signal Kit Installation Instructions

Installation. 1 User-supplied Equipment. 2 Installing the Slave Arm. 2.1 Preparing the Slave Arm Mounting Platform

2005 FIRST Pneumatic Manual

Mazda North American Operations Irvine, CA

LIONEL No Gabe the Lamplighter Owner s Manual 6/01

Thermal Wraps. GT Exhaust Accessories Installation and Operation Manual. Rev. A. Copyright 2012 GT Exhaust, Inc. All Rights Reserved

APIKOL AAN INTAKE MANIFOLD INSTALLATION INSTRUCTIONS

I-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:

Cable Shift Linkage Kit

OCTOPUS SELECTION & INSTALLATION GUIDE

Installation Tips For Crimestopper RS7 + Passlock-sl2(4) + DLRM + SPDT

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Cable Shift Linkage Kit

Pneumatic Control Module User s Guide

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

IMPORTANT! READ BEFORE INSTALLING!

Cable Shift Linkage Kit

MAGNETIC FIELD DUE TO A CURRENT CARRYING CONDUCTOR

INSTRUCTIONS for the Model GVL GLASS-VU LOADER

ELITE SERIES SURGICAL TABLES

Spray Height Controller

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

Specifications. Fluid Ambient and fluid temperature ( C)

Pregis Intellipack Corp E. Marshall Street, Suite Tulsa, OK (918)

TIP SHEET EVO-CHRT6(d) STAND-ALONE ADD-ON REMOTE STARTER

DTC P1415 Secondary Air Injection (AIR) System Bank 1

Contents. Overview Pinsetter Orientation...1-4

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

North American Automatic Manual Reset and Motorized Valves

LED REVEALS - INSTALLATION INSTRUCTIONS

Your Steering Column Specialist

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Kuhnke Technical Data. Contact Details

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

3/2-way Rocker Solenoid Valve for pneumatic systems

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

SingleShot. Installation and Operating Manual INTRODUCTION PREFACE SAFETY SPECIFICATIONS OPERATING CONDITIONS. Ambient Operating Temperature

Condition. Correction

INSTALLATION MANUAL 2000WCY

The LED Driver Expert

AGCO América do Sul (Factory Install) Installation Manual SP01

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

How to Replace Old Style Control Manifold with New Style Manifold on AS-Series Pumps

Remote Process Actuation Control System AirLINE - Siemens ET 200S

LUMASTAR EPL-100 J500 INSTALLATION, OPERATING & J MAINTENANCE

Pinch Valve Replacement (Enzymes)

E.S.P. Embedded Sensing Probes for Motor Brushes

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Part # Series RidePro 4 Way Compressor System 3 Gallon Tank Analog Gauges

Airglas, Inc. MANUAL NO. GLH AHSA. MODEL GLH3000 Ski Kit Actuated by Wipaire, Inc. Amphibious Float Hydraulic System

Wiring the FRC Control System

V-HID Headlight Installation Instructions

Installation Instructions

ACROMARK HOT STAMP PRESS

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

TOYOTA VENZA HANDS FREE BLU LOGIC Preparation

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

Spray Height Controller

Surepowr Series 100 Installation Manual

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

CALIBRATION PROCEDURE FOR THE ALLEN-BRADLEY PLC TEMPERATURE CONTROLLER:

350 S. St. Charles St. Jasper, In Ph Fax

IDS ILLINOIS, LLC. 2000/2500 DEVICE & OPERATOR

AUTOMATION AND CONTROL TRADE 19 TAR SANDS

1998 ENGINE PERFORMANCE. General Motors Corp. - Basic Diagnostic Procedures - 5.7L

Vehicle Rear Observation System With Integrated Parking Sensors

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

INSTALLATION INSTRUCTIONS:

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.

Installation Instructions Street Bandit Shifter

SURGICAL TABLE PARTS MANUAL

Service Manual. Baytech Service Manual for 6.0L Application

TIP SHEET T0937. Installation Tips For RS00/PS00 + ADS-TBSL-PL + SPDT

REPLACEMENT PARTS CATALOG

Installation Instructions Clamp Opening Control - Switch Operated

S200-P Passport Series Fire Pump Service Parts List

Accel 300+ Ignition Control System (84-95) - Installation Instructions

PNEUMATIC MANIFOLD VALVE PMV08

Buhler Versatile 23XX/24XX, Versatile 9X80, and New Holland Versatile 9X8X SmarTrax MD Installation Manual. P/N Rev A 04/16 E23635

PowerFlo Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

INSTALLATION INSTRUCTIONS AIR/OIL SEPARATOR KIT

Prodigy HDLV System Troubleshooting - Generation III

Finding and Fixing Vacuum Leaks on the LT5 Engine Marc Haibeck

OPERATORS MANUAL for AUTOMATIC RV SYSTEM. Comment [KO1]:

Photo 1. Shift pattern gate plate

Product Information Page

The first in the world!

TIP SHEET T0937. Installation Tips for RS00 + Passlock-sl2(4) + SPDT

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

Instruction Manual LongArm ABL3 Remote Operator for Medium Voltage Allen-Bradley Centerline** Motor Control Center Units

OP-500 On-Premise Series Instruction Manual

SPARE PARTS LIST CP COMPRESSOR. Model CPC CPC 50

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

John Deere (4730 & 4830) with Proportional Main Lift Installation Manual JD08

Installation Instructions Pro Stick Shifter

Transcription:

1.) Turn On your robot and sign into your designated Level of Access 2.) Go into Function>>>Function Set>>>Advanced>>>Output List 3.) On the first page of the Output List, on the far-right column, there will be Spare 1 Output (SP1) and Spare 2 Output (SP2). Next to SP1 there will be a number value that should read 27 ; and next to SP2, there will be a number value that should read 28. These numbers are your Output Values. SP1 & SP2 Values 4.) While on the same Output List page, select output 20 which is the output value for Gripper 3 (SG3). Change the value of SG3 from 20 to 27. Now select Next to view the second page of robot outputs. In the middle column of Output List Page 2, there will be Gripper 4 Output (SG4). Change the value of SG4 from 42 to 28. You can change the output values by selecting the output you would like to change and inputting the correct value as listed. 1

5.) Once you have changed the Output Values, go back to the Insert SP1 Value into SG3 Value robot s Insert SP2 Value into SG4 Value main page and select Manual. Once in Manual, turn on SG3 and SG4, lights DO11 and DO12 will light up. When SG3 is turned on, DO11 should light, and when SG4 is turned on DO12 should light. Once this has been confirmed, move on to the next step. When SG3 is turned on DO11 should light. When SG4 is turned on DO12 should light 6.) Remove both of the rectangular manifold covers. Manifold Covers 2

7.) Replace those covers with the provided 1-way FESTO directional valves. (Before valves are installed it is recommended to install the 6mm elbows and port plugs). Be sure to use the gaskets and bolts provided with the valves. 8.) Now with the manifolds installed, attached the solenoid plugs to the solenoid outlet on the 1-way directional valve. Terminate both the RED wires into a 24Vdc termination point on the adjacent terminal strip. Terminate each of the red solenoid wires into the 24Vdc termination point on the terminal strip 3

9.) Now with the 24Vdc wires properly terminated, wire the black wires into a spare output terminal. If there is no spare termination point, locate (2) spare light-blue wires either wrapped around the black multi-wire insulation or inside the black insulation. Make note of the number(s) located on the outside of the chosen light-blue wire, or the wire leading into the termination point on the terminal strip. If there are no wires present, then (2) small gauge wires need to be ran from the solenoid location to the motion controller. Spare Wire wrapped around Black Insulation (or may cut be inside black insulation) Spare termination points on terminal strip 10.) With the BLACK wires terminated to (2) specific & separate wires, terminate those separate wires into DO11 & DO12. Remember DO11 is SG3, and DO12 is SG4, therefore when SG3 or SG4 is turned on, the energized wire coming out of DO11 or DO12 will light up the corresponding solenoid on the 1-way valve. The other ends in which the BLACK solenoid wires were terminated. Terminate selected wires into DO11 & DO12 to send the output signal to the 1-way valve s solenoids. 4

11.) Once the 1-ways valves are wired, test the connections by bringing the robot into Manual mode and turning on SG3 & SG4. The solenoids in which DO11 & DO12 are wired to should illuminate, as with the respective DO11 & DO12 output indicator lights on the motion controller. 12.) With the valves wired and tested, run (2) 6mm air lines from the valves to the end of the vertical arm. Run the 6mm line through the plastic cable management wire ways. Be careful that the lines are not pinched or kinked anywhere throughout the run. Pull the air lines up and down through the vertical arm until they are protruding out of the end of the vertical arm. Verify the airlines are not stretched and installed properly. 13.) Now test the gripper lines for SG3 and SG4 once again in Manual mode. Label each line SG3 On / Off and SG4 On / Off according to the gripper response. If you need further assistance with this installation call ARI at 508-792-4305 or email our Service Department at service@absoluterobot.com. Thank You! 5

Procedure: 10004 7/2016 Rev. 1 6