Introduction. Lubrication Related Failures. Gear Couplings. Failure Analysis All Types (Page 1 of 7)

Similar documents
LUBE FITTINGS Cover halves have 3/8 NPT Iube holes. Use a standard grease gun and Iube fitting as instructed on Page 4.

Troubleshooting Power Transmission Couplings

Installation and Maintenance Instructions Falk Wrapflex (Page 1 of 7) 1. General Information. 2. Safety and Advice Hints DANGER! Type 10R.

Gear Drives. A third gear added to the system will rotate in the same direction as the drive gear Equal diameters = Equal number of teeth = Same speed

Thomas Disc Couplings Installation and Maintenance Series 52 Sizes with classical disc pack TM (Page 1 of 10) DANGER!

Ring Gear Installation Manual (Page 17 of 31)

Improving predictive maintenance with oil condition monitoring.

Bearings. Rolling-contact Bearings

DESIGN OF MACHINE ELEMENTS UNIVERSITY QUESTION BANK WITH ANSWERS. Unit 1 STEADY STRESSES AND VARIABLE STRESSES IN MACHINE MEMBERS

Introduction. Sample Nameplate. Gear Drive Identification. Bearing & Seal Identification. Corrosion Protection & Storage

Amerigear SF Spindle

IDENTIFYING DISC COUPLING FAILURES COUPLING FUNDAMENTALS

MAINTENANCE TECHNIQUES and GEAR UNIT FAILURE MODES. MIKE FIELD DAVID BROWN GEAR INDUSTRIES Revision 1

Chapter 11. Keys, Couplings and Seals. Keys. Parallel Keys

GRUNDFOS WHITE PAPER. When considering the overall pumping. COUPLINGS by Greg Towsley

We can get more favorable convenience and cost down by using the WCC Taper Grid Steel Flexible Coupling.

SKF Flex Coupling Installation Instructions

REASONS YOUR BEARINGS WILL FAIL. Ritbearing CORPORATION

Contents. SKF Grid Couplings Selection... 34

Service Bulletin No. 2916

DESIGN CONSIDERATIONS FOR ROTATING UNIONS SEALING TECHNOLOGIES

Falk Single & Double Engagement Lifelign Couplings Install. & Maint. TYPE G32 TYPE G20

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA

DIAMOND ROLLER CHAIN. For Agricultural and Construction Equipment

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Type A10. Falk Freedom Disc Couplings Installation and Maintenance. Type A10 Sizes 85 thru 8770 (Page 1 of 5)

Marine Engineering Exam Resource Review of Couplings

DIRACT BRAKES 70 SERIES 4 POST BRAKE INSTRUCTIONS

Synchronous Belt Failure Analysis Guide

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

Failures of Rolling Bearings in Bar and Rod Mill

80 Series 4 Post Brake Instructions

lea) shows a compression type. These couplings are used for

Falk Double Engagement Lifelign Couplings Install. & Maint. Type GR20 Sizes 1010 thru 1070 (Page 1 of 6) Packaging

Locking Assemblies Shrink Discs Rigid Couplings.

Ironman e Series Installation, Lubrication and Maintenance Instructions

Shaft Couplings Flange-Couplings Rigid Shaft Couplings Flexible Couplings

Packaging. Specifications Falk LTG (Long Term Grease) USDA Approval

PERFORMANCE THROUGH REVOLUTION

Falk Steelflex Couplings Installation and Maintenance

Service Manual. Spicer Drive Axle. AXSM-0400 September 2007

Automotive manufacturing accelerometer applications

H1600 Mechanical Overload Clutches HOR Series

Ironman E Series Installation, Lubrication and Maintenance Instructions

QUADRIVE OWNERS. CAUTION! Drives are shipped without oil. Sizes 4407/M4407. thru 4608/M4608 JR, JF & JSC. a good name in industry. PN Manual

LUBE FITTINGS Cover halves have 1 8 NPT Iube holes. Use a standard grease gun and Iube fitting as instructed on Page 5.

H2000 Pneumatic Overload Clutches

Series 54 and S54 Resilient Couplings

Automotive manufacturing accelerometer applications

Falk Steelflex Couplings Installation and Maintenance. Type T10 Sizes & (Page 1of 6)

Self-Adjust Clutch Installation Guide

TOUGH AND LONG LIFE (TL) SERIES SPHERICAL ROLLER BEARINGS

RFC SPECIALTY LOCKING DEVICES

LTI Cooling Tower Drive Shafts

High Capacity Industrial Universal Joints Installation and Maintenance Manual

AUTOFLEX DISC COUPLINGS

Falk Steelflex Horizontal & Vertical Couplings Install. & Maint. Types T50 & T70 Sizes 1030 thru 1200 (Page 1 of 7) Types T50/T70

High Performance Gear

ISO INTERNATIONAL STANDARD

How To Use This Manual. How the Controlled Torque Coupling or Clutch Operates. Table of Contents. Introduction. Overload Cutout Switch

TECHNICAL INFORMATION

CONTENT. 1. Syllabus 2. Introduction 3. Shaft 4. Coupling. Rigid coupling. Flange coupling. Sleeve (or) muff coupling Split muff coupling

Chapter 11 Rolling Contact Bearings

COUPLERS 5. Fax: +44 (0)

Comparison Chart. extremely difficult. Finally, separated components can rarely be re-used.

INSTRUCTION MANUAL FOR DODGE GRID-LIGN FLEXIBLE COUPLINGS

Disc Couplings 101. Ameridrives. Bauer Gear Motor. Bibby Turboflex. Boston Gear. Delroyd Worm Gear. Formsprag Clutch. Guardian Couplings.

IDENTIFICATION: INTRODUCTION

Ultramite Installation & Maintenance Instructions. Type UB Sizes 03 thru 12 (Page 1 of 12) TYPE UB

Clutch Installation Guide

Falk Double & Single Engagement Gear Couplings Install. & Maint. Type G/GP/GF20

Figure 9.1 is an example of a shaft with several features. It is a shaft for a Caterpillar tractor transmission 1

Model 320 / 320A Hinge Assembly

TORQUE LIMITER SERIES 600. Airjustor

Transmission Overhaul Procedures-Bench Service

Amerigear SL Spindle

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Packaging. Specifications Falk LTG (Long Term Grease)

Installation, Lubrication and. Maintenance. Instructions CONGRATULATIONS!

LOR Series Trig-O-Matic Lite Overload Release Clutch

TRANSLATION (OR LINEAR)

EXPANSION JOINT SELECTION GUIDE

TYPE TSC/TLC T SERIES FLEXIBLE DISC COUPLINGS

TSCHAN -B. Installation and Operation Manual TSCHAN Flexible Coupling BAWB 001-GBR-0 06/2004

Clutch Diagnosis - Causes of Failure

Now you can get design flexibility and lasting performance from our complete family of AccuDrive Precision Products.

Installation Instructions

Technical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints

LESSON Transmission of Power Introduction

Type MDX Size 300 (Page 1 of 5)

Maintenance Information

Boston Gear LOR Series

Failure Analysis for Plain Bearings

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

Module 1: Introduction to Drive Trains

COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

BOTTOM END SERVICE TOOLS SERVICE PRODUCTS ENGINE, CVT AND GEARBOX Subsection 10 (BOTTOM END)

Seals Stretch Running Friction Friction Break-Out Friction. Build With The Best!

Amerigear Standard Gear Couplings Flanged and Continuous Sleeve Designs

Installation and Operational Instructions for EAS -smartic synchronous clutch Type 48_. 5._ Sizes 01 2

Transcription:

All Types (Page 1 of 7) Introduction A gear coupling serves as a mechanical device which connects shafts of two separate machines and accommodates small amounts of shaft misalignment. Commercial gear couplings transmit more torque for their physical size than other types of couplings. Because of this load transmitting capability, gear couplings have received wide acceptance on the higher speed applications, and on applications requiring high torque capacity combined with low inertia of the drive system. A gear coupling consists of two shaft hubs with external teeth which are connected by means of a sleeve, generally of two pieces, containing internal teeth. The working action of a gear coupling is that of a flexible spline with the hubs and sleeves rotating together. Adequate lubrication with the proper type is an essential requirement for successful operation of the gear coupling. The purpose of this paper is to review the areas in which gear couplings have experienced difficulties and to identify the various types and probable causes of failures. Lubrication Related Failures The greatest problem in successful operation of gear couplings is to maintain an adequate film of lubricant between the gear teeth. It has been found that a lack of proper lubricant is the principal cause of gear coupling failures. Early stages of lubrication deficiency are shown in Figure 1. The contact area appears scuffed. As a result of the loss of lubricant film between the external and internal teeth, the surfaces rubbed against each other causing small metal particles to break loose. In some cases fretting corrosion, as evidenced by the appearance of a red powder, may be noted. The contacting internal sleeve tooth has a similar scuffed contact area as illustrated in Figure 2. Figure 1 HUB TEETH (EG-44113) Figure 2 SLEEVE TEETH (EG-43719)

Failure Analysis (Page 2 of 7) All Types Lubrication Related Failures (Continued) Continued operation of a gear coupling with a lubrication deficiency often produces a badly worn surface, as shown in Figure 3, where 70% of the tooth is worn away. Ultimately, unless the wear can be stopped, the tooth will bend over, as shown in Figure 4, and the mesh will become disengaged. The sleeve or internal teeth may suffer similar wear damage, see Figures 5 and 6, although generally the hub or external teeth will bend or roll over before the sleeve teeth. Proper coupling operation requires both sufficient and correct lubrication. The lack of lubricant in gear couplings is usually the result of an insufficient lube filling, an omitted lube plug, or a damaged seal or gasket. If oil is used as the lubricant, leakage often occurs through the shaft keyway, unless the keyways are adequately sealed. Other reasons for lubricant deficiencies in gear couplings may involve the lubricant itself. The lubricant, either grease or oil, may have improper viscosity for the operating speed or temperatures. In the case of grease lubricants, the oil may separate from the soap base because of centrifuging. In all these cases the lubricant either becomes too thin to support the tooth mesh load or is too thick to flow into the tooth mesh contact area. For these reasons an extreme pressure (EP) lubricant of the correct type, as well as speed and temperature limitations must be adhered to. Refer to Manual 458-010. Figure 3 (EG-44770) Figure 4 (EG-42861) 458-910 June 1984 (.PDF Revision) Supersedes 448-810, 8-70 The Falk Corporation, P.O. Box 492, Zip 53201-0492 3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131 Fax: 414-937-4359 e-mail: falkinfo@falkcorp.com web: www.falkcorp.com

All Types (Page 3 of 7) Misalignment Wear Operating a gear coupling under excessive misalignment will promote wear on the teeth. The gear coupling is designed so that it will accommodate the alignment limits given in the service manual without metal to metal contact in the seal area. If wear is noted in the hub seal area as in Figure 7, it is proof that this coupling was operated with excessive misalignment. The illustrated tooth wear could be attributed to a combination of tooth sliding movement and lack of lubricant because the probability of lube leakage at the seal increases with misalignment. Figure 5 (EG-44771) Figure 7 (EG-43212) Figure 6 (EG-43670)

Failure Analysis (Page 4 of 7) All Types Misalignment Wear (Continued) If a Slide type gear coupling operates so that its hub teeth mesh with the sleeve teeth near the gap, as shown in Figure 8, the static misalignment capacity of the coupling will be reduced to a maximum of 1/2 per mesh. For example, reducing the distance between tooth mesh areas by one half will nearly double the sleeve tilt angle. With increased tilt there will be increased sliding between the mating teeth and a greater possibility of scuffing. For this reason, installations of slide type gear couplings require close attention to alignment and speed limits. If axial hub movement occurs more than 5 times per hour, add 0.25 to the normal service factor as noted in the selection procedure of Bulletin 451-110. Figure 8 458-910 June 1984 (.PDF Revision) Supersedes 448-810, 8-70 The Falk Corporation, P.O. Box 492, Zip 53201-0492 3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131 Fax: 414-937-4359 e-mail: falkinfo@falkcorp.com web: www.falkcorp.com

All Types (Page 5 of 7) Hub Fractures It is possible to have gear coupling hubs fail over the keyway from a combination of hoop stress produced by the interference fit and a high tensile stress as a result of excessive torque loads transmitted through the key. Gear coupling hubs are normally made from a.3 to.5 carbon steel having a minimum tensile strength of 65,000 psi. An example of a hub failure from a single overload application is shown in Figure 9. The break in the hub occurred at one corner of the keyway and extended the full length of the hub. Another view of the same hub, Figure 10, shows a deformation of the keyway from the key. It can be noted that the hub break occurred at the keyway corner away from where the load was applied. As a result of the hub failure shown in Figures 9 and 10, the mating sleeve had a crack extending nearly its full length, Figure 11. In order to remove the sleeve from the hub, it was necessary to cut the sleeve in the section at the failure crack and 180 away from the crack. It is interesting to note that none of the teeth in either hub or sleeve were broken. In order to prevent hub fractures, it is necessary that couplings be selected using the proper service factor for the application based on motor capacity or where a brake is involved in the system, the coupling should be selected on the brake capacity. Figure 10 (EG-45425) Figure 9 (EG-45426) Figure 11 (EG-45427)

Failure Analysis (Page 6 of 7) All Types Flange Fastener Failures The gear coupling sleeve design most commonly used by industry consists of two flanged sleeve halves which are bolted together. Each flanged sleeve has internal teeth which form the spline connection for the external gear teeth of the hubs. Transmitted torque passes from the hub through the gear teeth to one of the flanged sleeve halves. Then the torque load must pass from one flanged sleeve to the other through the bolted and gasketed flange. The fasteners used to connect the sleeves are designed so that the body of the fastener extends into both sleeve flanges. The bolts are SAE grade 5 or 8, depending on coupling size. In most applications the combination of the frictional transmitting torque of the bolted flanges plus the allowable shear capacity of the bolt body are sufficient to transmit the normal starting and operating loads applied to a properly selected gear coupling. In certain cases, where high starting and impact loads occur in combination with reversing service or severe load fluctuations exist, fasteners have failed in reverse bending fatigue, as shown in Figure 12. This failure shows that the bolt head actually fatigued off of the bolt body diameter. It should be noted that the characteristic beach marks, that often form on the fracture surface of soft material, are not always exhibited to the naked eye in high strength material failures. For this reason the mode of failure, ie; bending fatigue, may not be properly identified. Bending fatigue loading may also be characterized by: fretting corrosion on the bolt body diameter, imbedding of the bolt washer face diameter into the sleeve, wallowing out of the sleeve flange holes and/or offset of the bolt body diameter. This type of failure can be the result of insufficient fastener tightening torque, system torsional vibration or reversing loads which exceed the flange joint capacity. Assuming that the flange fasteners have been installed with the proper tightening torque as specified in the installation manuals, fatigue type fastener failures of a gear coupling are an indication of loads that repeatedly exceed 1.5 to 2.5 times rated torque of the coupling. One must use care when correcting flange bolt failures. Before substituting higher hardness fasteners or a larger coupling size which would reduce the possibility of further coupling failures, review the loads in the entire system to be sure that other elements will not fail. In some cases, a simple correction of bolt failures has led to extensive damage to other critical connected machinery. In most cases, if the coupling was properly selected for the drive, flange bolt failures would be an indication that the system has been subjected to unexpected overloads. Sleeve Seal End Ring Failures Sleeve seal end ring fatigue failures, Figure 13, result from loads imposed on the sleeve seal cage. This type of failure may be the result of radial flexing under excessive misalignment, and/or axial contact due to improper gap setting (too large), or hub axial float. Refer to Manual 428-870, Axial Movement of Power Transmitting Shaft Coupling. Also note the hub tooth contact pattern on the seal cage face, Figure 13. Figure 12 (EG-51975) Figure 13 (EG-51974) Conclusion: The main types of failure encountered with gear couplings are worn teeth. Where tooth wear progresses rapidly, eventual disengagement of the gear coupling can occur when either external or internal teeth roll or bend over. Since gear coupling tooth wear is generally related to the lubricant, it is necessary to determine the reason for lube deficiency and make the required correction. Gear coupling hub failures can occur from a combination of loads produced by the interference fit and transmitted torque. Adherence to the proper service factor for an application will minimize hub failure problems. Occasionally the gear coupling flange bolts break. If the correct bolt tightening torque has been used, review the system for high peak loads or severe load fluctuations. Sleeve seal cage end ring failures may result from high misalignment, improper gap setting and/or hub axial float. Author: Q. W. HEIN Manager - Clutch and Coupling Engineering 458-910 June 1984 (.PDF Revision) Supersedes 448-810, 8-70 The Falk Corporation, P.O. Box 492, Zip 53201-0492 3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131 Fax: 414-937-4359 e-mail: falkinfo@falkcorp.com web: www.falkcorp.com

All Types (Page 7 of 7) Falk 1000 Series Crowned Tooth Falk 1000 series gear couplings combine over eighty years of skill and know-how in the design and construction of precision gears and flexible shaft couplings. These couplings offer a better all-around design over competition in the following areas: LARGEST MAXIMUM BORE IN THE MARKET Use the same size coupling on a larger shaft or use the stronger 1000G on the same size shaft. Specify the 1000G and save an average of 15-20% on a project basis over the cost of smaller bore couplings. IMPROVED LUBRICATION SYSTEM Falk Long Term Grease (LTG) eliminates routine lubrication cycles for up to 3 years. The location of the lubrication hole in the sleeve ensures that an adequate grease reservoir will be maintained close to the gear mesh. INTERCHANGEABILITY 1000G couplings are half for-half interchangeable with ALL standard gear couplings. Falk replacement half couplings provide additional hub strength and lower gear mesh loads. BETTER FASTENER DESIGN Grade 8 fasteners are used for added strength. Prevailing torque locknuts (PTL) eliminate the need of lock washers. Non-turning locknut allows installation with only one wrench. Exposed bolt design above, furnished as standard. Shrouded bolt design below, available for Sizes 1010 thru 1055 when specified. Added Falk Benefits APPLICATION EXPERIENCE When you specify Falk, you get experienced field sales and engineering assistance (over 80 years). IMPARTIAL CHOICE OF COUPLING Choose from Gear, Steelflex (grid-type), Torus (elastomer) and Falk Sime (fluid). SYSTEM COORDINATION Falk also designs and manufactures an unmatched variety of gear drives. A broad range allows various choices, we fit the drive or coupling to your machine, not vice versa. NATIONWIDE SERVICE & AVAILABILITY Falk products and service are nearby. In the continental United States and Canada we have over 30 district sales offices, over 500 distributors and 5 regional distribution centers.