Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

Similar documents
Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

SOUND ATTENUATED ENCLOSURES

Modular Acoustic Enclosures

Modular Acoustic Enclosures

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

Modular Acoustic Enclosures

ENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S.

Enclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Modular Acoustic Enclosures

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

Flexible, Reliable, Connected Power

Hydraulic electronic unit injection

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

Generator Set Specifications 480 ekw 600 KVA

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Generator Set Specifications 100 ekw (125 kva)

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

C32 ACERT Generator Set Electric Power

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Generator Set Specifications 320 ekw (400 kva)

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Aftercooler (Separate Circuit) N/A N/A

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

STANDBY 200 ekw 250 kva

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

Generator Set Specifications 60 ekw (75 kva)

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

power moving forward KVA RANGE Performance I Durability I Serviceability

Continuous, Prime, Standby, Mission Critical

Expert Design...Trusted Power

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Specifications. C13 Generator Set Electric Power

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SETS

The kva RAnge

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

220 to Volts or 1800 RPM

power made simple kva RANGE Performance I Durability I Serviceability

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

220 to Volts or 1800 RPM

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

one giant leap for electric power. The 2-4MW family of diesel generator sets powered by the C175

XQ80 RENTAL. 60 Hz FEATURES

220 to volts. Electronic unit injection

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Voltage 220 to or 1800 RPM

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

3412C Generator Set Electric Power. Specifications. Benefits and Features

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

Specifications. 3406C Generator Set Electric Power

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby kw Prime kw

Designed for Today s World

Designed for Today s World

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Transcription:

Sound Attenuated Enclosures Level 1, Level 2 & Level 3 6.8 22 kva (B Series) Range The compact design of the 6.8 22 kva SA Level 1, Level 2 and Level 3 enclosures range provides the flexibility of optimum sound attenuation depending on requirements. Designed on modular principles, the enclosures will have lift off doors or vertically hinged doors providing optimal service and maintenance access. Picture shown may not represent actual configuration The enclosures are constructed with galvanised steel, designed to resist corrosion and handling damage. Developed through continuing research and development by our specialist engineers, the enclosures are weather protective and incorporate internally mounted exhaust silencers. Features Durable and Robust Construction Galvanised steel protected by powder coat paint Single piece roof structure Baseframe extends beyond enclosure protecting against handling damage Black finish stainless steel locks and hinges Zinc plated / stainless steel fasteners Excellent Service and Maintenance Access Optional side hinged doors on both sides of the enclosure Optional lift off only doors on both sides of the enclosure Coolant drain piped to baseframe, exterior to the enclosure Security and Safety Control panel viewing via large viewing window Emergency stop push button mounted on enclosure exterior Cooling fan and battery charging alternator fully guarded Exhaust silencing system totally enclosed for operator safety Transportability Drag points on baseframe facilitating handling from both sides All of the sound attenuated enclosures reduce sound levels to comply with the stage II levels of the European Community Directive 2000/14/EC, effective from 3 January 2006. LEHE1135-02 Page 1 of 7

Sound Pressure Levels (dba) SA Level 1 (EUR1) DE13.5E3 DE16E0 DE18E3 DE22E3 DE7.5E3S DE11E3S DE14E3S DE16E3S Duty 50 Hz 60 Hz 15 m 7 m 1 m 15 m 7 m 1 m Prime 65 66 71 72 82 84 68 69 74 75 85 87 Standby 65 67 71 73 82 85 68 70 74 76 85 87 Prime 65 66 71 72 82 84 68 69 74 75 85 87 Standby 65 67 71 73 82 85 68 70 74 76 85 87 Prime 65 67 71 73 83 84 70 71 76 77 86 88 Standby 65 68 71 74 83 85 70 72 76 78 87 88 Prime 66 69 72 75 84 85 Standby 67 70 73 76 84 86 Prime 64 66 70 72 80 82 67 69 73 75 84 85 Standby 64 66 70 72 81 83 68 69 74 75 84 86 Prime 65 67 71 73 82 84 68 69 74 75 84 86 Standby 66 69 72 75 82 86 68 70 74 76 85 87 Prime 65 66 71 72 82 84 68 69 74 75 85 87 Standby 65 67 71 73 82 85 68 70 74 76 85 87 Prime 65 67 71 73 83 84 70 71 76 77 86 88 Standby 66 68 72 74 83 85 70 72 76 78 87 88 Prime 64 66 70 72 80 82 67 68 73 74 84 85 Standby 64 66 70 72 81 83 68 69 74 75 84 86 Prime 65 67 71 73 81 84 68 69 74 75 84 86 Standby 65 68 71 74 82 85 68 70 74 76 85 87 LEHE1135-02 Page 2 of 7

Sound Pressure Levels (dba) SA Level 2 (EUR1) DE13.5E3 DE16E0 DE18E3 DE22E3 DE7.5E3S DE11E3S DE14E3S DE16E3S Duty 50 Hz 60 Hz 15 m 7 m 1 m 15 m 7 m 1 m Prime 54 55 60 61 70 71 57 58 63 64 72 73 Standby 55 56 61 62 70 72 57 58 63 64 72 74 Prime 54 55 60 61 70 71 57 58 63 64 72 73 Standby 55 56 61 62 70 72 57 58 63 64 72 74 Prime 55 56 61 62 71 72 58 59 64 65 73 73 Standby 55 56 61 62 71 72 58 59 64 65 73 74 Prime 55 57 61 63 71 72 Standby 56 58 62 64 72 73 Prime 57 58 63 64 74 74 60 61 66 67 76 76 Standby 57 59 63 65 74 75 60 61 66 67 76 76 Prime 58 60 64 66 74 75 60 61 66 67 76 76 Standby 58 61 64 67 74 76 61 61 67 67 76 76 Prime 54 55 60 61 70 71 57 58 63 64 72 73 Standby 55 56 61 62 70 72 57 58 63 64 72 74 Prime 55 56 61 62 71 72 58 59 64 65 73 73 Standby 55 57 61 63 71 72 58 59 64 65 73 74 Prime 57 58 63 64 74 74 60 61 66 67 76 76 Standby 57 59 63 65 74 75 60 61 66 67 76 76 Prime 57 59 63 65 74 75 60 61 66 67 76 76 Standby 58 60 64 66 74 76 61 61 67 67 76 76 LEHE1135-02 Page 3 of 7

Sound Pressure Levels (dba) SA Level 3 (EUR1) DE13.5E3 DE16E0 DE18E3 DE22E3 DE7.5E3S DE11E3S DE14E3S DE16E3S Duty 50 Hz 60 Hz 15 m 7 m 1 m 15 m 7 m 1 m Prime 51 52 57 58 70 71 52 53 58 59 68 72 Standby 51 53 57 59 70 72 52 54 58 60 69 73 Prime 51 52 57 58 70 71 52 53 58 59 68 72 Standby 51 53 57 59 70 72 52 54 58 60 69 73 Prime 52 53 58 59 70 71 53 54 59 60 69 71 Standby 52 53 58 59 70 72 53 54 59 60 69 72 Prime 52 54 58 60 71 72 Standby 53 54 59 60 71 72 Prime 53 54 59 60 71 72 54 55 60 61 71 72 Standby 53 54 59 60 71 73 54 55 60 61 71 73 Prime 54 55 60 61 72 73 54 55 60 61 71 73 Standby 54 55 60 61 72 74 55 56 61 62 72 74 Prime 51 52 57 58 70 71 52 53 58 59 68 72 Standby 51 53 57 59 70 72 52 54 58 60 69 73 Prime 52 53 58 59 70 71 53 54 59 60 69 71 Standby 52 53 58 59 70 72 53 54 59 60 69 72 Prime 53 54 59 60 71 72 54 55 60 61 71 72 Standby 53 54 59 60 71 72 54 55 60 61 71 72 Prime 53 54 59 60 71 73 54 55 60 61 71 73 Standby 54 55 60 61 72 73 55 56 61 62 71 74 LEHE1135-02 Page 4 of 7

Dimensions and Weights SA Level 1 C A B A: B: C: Weight*: kg (lb) 1550 (61.0) 935 (36.8) 1055 (41.5) 340 (750) (EUR1) 1550 (61.0) 935 (36.8) 1055 (41.5) 347 (765) DE13.5E3 1550 (61.0) 935 (36.8) 1055 (41.5) 417 (919) DE16E0 1550 (61.0) 935 (36.8) 1055 (41.5) 444 (979) DE18E3 1550 (61.0) 935 (36.8) 1055 (41.5) 481 (1060) DE22E3 1550 (61.0) 935 (36.8) 1055 (41.5) 494 (1089) DE7.5E3S 1550 (61.0) 935 (36.8) 1055 (41.5) 347 (766) DE11E3S 1550 (61.0) 935 (36.8) 1055 (41.5) 424 (935) DE14E3S 1550 (61.0) 935 (36.8) 1055 (41.5) 486 (1071) DE16E3S 1550 (61.0) 935 (36.8) 1055 (41.5) 494 (1089) *Net weight with lube oil, and coolant, no fuel. LEHE1135-02 Page 5 of 7

Dimensions and Weights SA Level 2 C A B A: B: C: Weight*: kg (lb) 1755 (69.1) 935 (36.8) 1055 (41.5) 391 (863) (EUR1) 1755 (69.1) 935 (36.8) 1055 (41.5) 398 (877) DE13.5E3 1755 (69.1) 935 (36.8) 1055 (41.5) 468 (1032) DE16E0 1755 (69.1) 935 (36.8) 1055 (41.5) 495 (1091) DE18E3 1755 (69.1) 935 (36.8) 1055 (41.5) 532 (1173) DE22E3 1755 (69.1) 935 (36.8) 1055 (41.5) 545 (1202) DE7.5E3S 1755 (69.1) 935 (36.8) 1055 (41.5) 398 (878) DE11E3S 1755 (69.1) 935 (36.8) 1055 (41.5) 475 (1047) DE14E3S 1755 (69.1) 935 (36.8) 1055 (41.5) 537 (1184) DE16E3S 1755 (69.1) 935 (36.8) 1055 (41.5) 545 (1202) *Net weight with lube oil, and coolant, no fuel. LEHE1135-02 Page 6 of 7

Dimensions and Weights SA Level 3 C A B A: B: C: Weight*: kg (lb) 1830 (72.0) 935 (36.8) 1055 (41.5) 401 (885) (EUR1) 1830 (72.0) 935 (36.8) 1055 (41.5) 408 (899) DE13.5E3 1830 (72.0) 935 (36.8) 1055 (41.5) 478 (1054) DE16E0 1830 (72.0) 935 (36.8) 1055 (41.5) 505 (1113) DE18E3 1830 (72.0) 935 (36.8) 1055 (41.5) 542 (1195) DE22E3 1830 (72.0) 935 (36.8) 1055 (41.5) 555 (1224) DE7.5E3S 1830 (72.0) 935 (36.8) 1055 (41.5) 408 (900) DE11E3S 1830 (72.0) 935 (36.8) 1055 (41.5) 485 (1069) DE14E3S 1830 (72.0) 935 (36.8) 1055 (41.5) 547 (1206) DE16E3S 1830 (72.0) 935 (36.8) 1055 (41.5) 555 (1224) *Net weight with lube oil, and coolant, no fuel. LEHE1135-02 (10/16) www.cat-electricpower.com 2016 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos ACERT, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.