BLOCK GAUGE. user manual

Similar documents
user leaflet ANALOGUE BLOCK GAUGE

Block Gauge. user manual

user leaflet DIGITAL BLOCK GAUGE

Block Gauge Family Digital and Analogue Universal Gauges

S-SERIES DISPLACEMENT TRANSDUCERS

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

Linear Drive with Ball Screw Drive Series OSP-E..SB

Wind Direction Vane. Z345. Installation Guide.

STI LVDT Displacement Sensors

MS-13SR series Spring Return Linear Potentiometers

2-way proportional throttle valve for block installation

SLS Linear Displacement Sensors

SCHMIDT ManualPress From 1.6 kn to 22 kn / 360 lbs. to 4,945 lbs.

Displacement Sensor. Model 8739, 8740, 8741

FEATURES AND BENEFITS

Electronic Length Measuring Equipment

Linear Actuator with Ball Screw Series OSP-E..S. Contents Description Overview Technical Data Dimensions 89

Eddy current sensors eddyncdt

LBB ULTRA-PRECISION GAGE HEADS

Standard cylinders DDPC, with measured-value transducer DADE

ACTUATORS POSITION SENSOR

ZERO-POINT CLAMPING SYSTEM

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

DURA-TRANS NB-SERIES. Bi-Directional Transfer NB-10 NB-20 TECHNICAL SPECIFICATION OPERATING PRINCIPLES 6-1.1

Rodless Pneumatic Cylinders Series OSP-P

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

P3 3-STOP POSITIONER IOM

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Control Valves Positioner

Control Valves Positioner

ORIGA Pneumatic Linear Drives OSP-L

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

V SWISS MADE LINEAR TECHNOLOGY

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

RST INSTRUMENTS LTD.

Modular. Precise. Robust. AGE-S-XYZ Compensation Unit

Weatherproof Tubular Slip Ring Assembly

SCHMIDT ManualPress. From 1.6 kn to 22 kn

DATAFLEX 42/1000 Torque Measuring Shaft Operating/Assembly instructions DATAFLEX

The Series I/P Current to Pressure Transducer

Cleveland-Kidder. Design Features

Extreme Environment For high pressure, low temperature, and high temperature applications

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

Linear Drive with Toothed Belt Series OSP-E..B. Contents Description Overview Technical Data Dimensions Order Instructions 46

Environment Clean Room Specification

GSM. Modular Design. Versions of the series. Type GSM. Gripper type P Z W R. Size. {} AS IS without O.D. clamping I.D. clamping

SIT-LOCK self locking elements

Load Cell for Manually Operated Presses Model 8451

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

MOTORSPORT MEASUREMENT & CONTROL SENSORS

Linear Actuator with Ball Screw Series OSP-E..S. Contents Description Overview Technical Data Dimensions 79

DATAFLEX 110/... Torque Measuring Shaft Operating/Assembly instructions DATAFLEX. Torque measuring shaft type 110/

Flexible. Fast. Reliable. ELM Compact Linear Module

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

300 & 400 Series Positioning Tables

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL

SRS SEALED ROTARY SENSORS

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

Arm - TX series 40 family

PI-Air WV-121. PI-Air type WV-121 Pneumatic cylinder actuator with positioner

Low Pressure Sensor. Overview. Specifications. Installation and Operation

AMS. Compact Linear Potentiometers & Tranducers

HCA & HCA-RA SERIES Hermetically Sealed AC LVDT

The World Leader in Force Measurement Solutions

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

PC-Series Precision Linear Actuators. Optimize Your Machine and Save Energy With Reliable, High Performance, Compact Actuators

Linear drives DGC Key features

EMaSM. Principles Of Sensors & transducers

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Series 10-ZSE40A(F)/10-ISE40A

Data Sheet. I/P and E/P converters. RS stock numbers ,

STT280 SEALED TILT SENSOR

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

2-Color Display High-Precision Digital Pressure Switch

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

LINEAR ACTUATOR MODULE Page 5-1. Table Of Contents

LINEAR POTENTIOMETERS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

MF4E MF4E

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Introduction to Torque Calibration

Standard Scales SERIES 182 Made of Low-Expansion Glass. Working Standard Scales SERIES 182 E-32

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions

Electric Mini Slides MSC-EL

Becker Precision Equipment

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

LF Series Spring Return Direct Coupled Actuator

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

LJ1H LEJS40 AC

Compliant. Precise. Reliable. FUS Insertion Unit

Troubleshooting Bosch Proportional Valves

7330 Pro-Stik II Magnetostrictive Level System

Linear Drive with Toothed Belt and Integrated Guide with Recirculating Ball Bearing Guide with Roller Guide Series OSP-E..BHD

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Motion without compromise

RoHS Directive-Compliant Motorized Linear Slides EZS Series for Clean Room Use. Features

Gripping rotary modules.

Transcription:

BLOCK GAUGE user manual

1.0 Index Section Title Page 1.0 Index....................... 1 2.0 Safety Summary............... 2 3.0 Introduction.................. 3 4.0 Components of the Block Gauge... 4 5.0 Care of the Block Gauge......... 5 6.0 Mechanical Installation........... 6 6.1 Tip Installation/Replacement....... 7 6.2 Tool Holder Installation/Adjustment.. 8 6.3 Spring Installation/Adjustment...... 9 6.4 Pneumatic Actuator Installation..... 10 7.0 Maintenance................... 11 7.1 Sensor Replacement............ 11 8.0 Specifications.................. 12 8.1 Measurement.................. 12 Section Title Page 8.2 Mechanical.................. 14 8.3 Environmental............... 14 8.4 Electrical Interface............. 15 9.0 Connections................. 16 9.1 Analogue Block Gauge......... 16 9.2 Digital Block Gauge........... 17 10.0 Outline Drawings.............. 18 10.1 Mechanical Drawings........... 18 10.2 Configuration Drawing.......... 21 Return of Goods Solartron Sales Offices 1.0 Index 2

2.0: Safety Summary Terms in this Handbook Warning statements identify conditions or practices that could result in personal injury or loss of life. CAUTION statements identify conditions or practices that could result in damage to the equipment or other property. Symbols in this manual This symbol indicates where applicable cautionary or other information is to be found. WARNINGS: Do not operate in an explosive atmosphere To avoid explosion, do not operate this equipment in an explosive atmosphere. Air Pressure Under no circumstances should the recommended maximum overpressure of 7 bar be exceeded when using pneumatics with the Block Gauge. NOTES: This equipment contains no user serviceable parts This equipment must be returned to your Solartron dealer for all servicing and repair. Low Voltage This equipment operates at below the SELV and is therefore outside the scope of the Low Voltage Directive. 2.0: Safety Summary 3

3.0: Introduction The Block Gauge family makes precision measurements of bores and cavities a simple and reliable process. The use of these devices is ideal in applications where space is limited and where the use of axial probes is not possible. Both digital and analogue versions of the Block Gauge are available, with measurement ranges of 2mm, 5mm or 10mm. The analogue versions can be used with standard conditioning electronics. The digital versions are designed to be connected directly onto the Orbit Measurement Network, a modular system enabling fast and versatile connection of multiple probes. 3.0: Introduction 4

4.0: Components of the Block Gauge Key 1 Sensor 2 Sensor Grub Screw 3 Sensor Grub Screw 4 Pneumatic Actuator 5 Spring Holder 6 Spring 7 Tool Holder 8 Tip Carrier 9 Tip 10 Tip Carrier Grub Screw 11 Caphead Screw 4.0: Components of the Block Gauge 5

5.0: Care of the Block Gauge The Block Gauge is a rugged parallel motion Universal Gauge designed to withstand the rigours of an industrial manufacturing environment. However, care should be taken during installation to avoid dropping the Block Gauge or subjecting it to severe shock loads. In order to avoid damage to the linear bearings, it is important not to exceed the specified torque setting (1.5 to 2N m) of the fixing screw (11) when adjusting the tool holder (7). The contact tip (9) should be fitted to the tip carrier (8) and tightened before the tip carrier is fitted to the tool holder. Tip carriers are available in 20 mm, 30 mm and 40 mm versions. 5.0: Care of the Block Gauge 6

6.0: Mechanical Installation First establish the orientation in which the Block Gauge will be used. The choice of return spring (6) and its position depends on the orientation of the gauge and should be made after the tool holder (7) and contact tip (9) have been fitted. A set of return springs (for different measurement forces) are included with each gauge. It may be easier to set contact tip forces as close as possible to operating forces before the Block Gauge is installed onto a machine or fixture. Final adjustments may then be made after installation. Final adjustment of the spring force is made by winding the spring holder (5) in or out. (section 6.3) When fitting a pneumatic actuator (4), ensure that the threads in the Block Gauge and the actuator are clean. In order to avoid damage to the actuator or the Block Gauge, it is important not to exceed the specified air pressure. When mounting the Block Gauge in a fixture, care must be taken not to drop the gauge or apply excessive shocks which may degrade performance. 6.0: Mechanical Installation 7 It should be secured by using the fixing screws at the base of the Block Gauge. The fixing screws are M6. The thread depth in the body is 8 mm. Tip (9) Return Spring (6) Anti rotation adjustment Tip Carrier (8) Tool Holder (7) Sensor (1) Pneumatic Actuator (4) Spring Holder (5) CAUTION The pneumatic Block Gauge works at a higher air pressure than pneumatic Gauging Probes. In order to avoid damage to Gauging Probes when used in conjunction with Block Gauges, it is important that separate regulators are used for each product.

6.0: Mechanical Installation (continued) 6.1: Tip Installation/Replacement To avoid placing strain on the tool holder (7) and the Block Gauge frame, the tip carrier (8) should be removed from the tool holder before fitting or removing a tip (9). The Block Gauge tool holder allows the Block Gauge tip and tip carrier to be mounted in one of three different planes for maximum flexibility. Tip Removal 1. Loosen the 2.5 mm tip carrier grub screw (10) `which holds the tip carrier (8) in place. 2. Remove the tip carrier from the tool holder (7). 3. Unscrew the tip (9) from the end of the tip carrier. Tip Installation 1. Screw the tip (9) into the tip carrier (8). 2. Position the tip carrier in the tool holder (7). 3. Tighten the 2.5mm tip carrier grub screw (10). Take care not to overtighten it. Tip (9) Tip Carrier (8) Tip Carrier Grub Screw (10) Tool Holder (7) 6.0: Mechanical Installation 8

6.0: Mechanical Installation (continued) 6.2: Tool Holder Installation/Adjustment The tool holder is infinitely adjustable along the industry standard dovetail fitting on the Block Gauge frame. This dovetail fitting ensures that the gauge is rigid yet easy to install and adjust. Tool Holder Adjustment 1. Loosen the caphead screw (11) located on the tool holder (7) using a 3 mm Allen key. 2. Slide the tool holder to the required position. 3. Tighten the screw. CAUTION In order to avoid damage to the linear bearings, it is important not to exceed the specification for the torque setting (1.5 to 2 Nm) of the fixing screw when adjusting the tool holder. Tool Holder Installation To remove the tool holder (7), loosen the caphead screw (11) located on the tool holder using a 3 mm Allen key. Slide the tool holder off the dovetail. To re-install the tool holder, simply slide it over the dovetail joint to the required position and then tighten the caphead screw. Tool Holder (7) Caphead Screw (11) Dovetail Fitting 6.0: Mechanical Installation 9

6.0: Mechanical Installation (continued) 6.3: Spring Installation/Adjustment The choice of spring return and its position depends on the orientation of the gauge and should be made after the tool holder and contact tip have been fitted. (See section 6.2). A set of four return springs are included with each gauge. 1. Unscrew and remove the spring holder (5) or pneumatic actuator (4) if this was being used. 3. Select an appropriate spring, and insert this into the frame. 4. Insert the screw holder back into the Block Gauge frame and screw in. 5 4 2. Remove the spring (6) if installed. 6 5. Final adjustment to the spring force is made by winding the spring holder in or out using a flat blade screwdriver. 6.0: Mechanical Installation 10 Refer to section 10.2 for information on the configuration of the spring and pneumatic actuator.

6.0: Mechanical Installation (continued) 6.4: Pneumatic Actuator Installation 1. Unscrew and remove the spring holder (5). 2. Remove the spring (6) if it is installed. 3. Install a spring and spring holder opposite to where the pneumatic actuator is to be installed (section 6.3). 4. Insert the pneumatic actuator (4) and screw until tight. Do not overtighten. 6 5 4 To maximise the working life of the Block Gauge, the air supply should be both clean and dry for continual reliable operation. The air should have a maximum relative humidity of 60% RH and be filtered to better than 5 µm particle size. When fitting a pneumatic actuator, ensure that threads in the Block Gauge and the actuator are clean. In order to avoid damage to the actuator or the Block Gauge, it is important not to exceed the specification for air pressure. CAUTION The pneumatic Block Gauge works at a higher air pressure than pneumatic gauging probes. In order to avoid damage to gauging probes when used in conjunction with Block Gauges, it is important that separate air pressure regulators are used for each product type. 6.0: Mechanical Installation 11

7.0: Maintenance 7.1 Sensor Replacement - Analogue Version Only Sensor Removal 1. Loosen the two sensor grub screws (2 & 3) which hold the sensor (1) in place. 2. Gently ease the sensor away from the frame. Care must be taken not to damage the core or the gaiter during removal. Sensor Installation 1. Insert the replacement sensor (1) into the Block Gauge frame. Care must be taken not to damage the core or the gaiter during insertion. The carrier must not protrude from the T-piece. 2. Tighten sensor grub screw (3), but leave screw (2) loose. 3. Adjust the spring holder (5) opposite the sensor so that there is a small gap of approximately 0.25 mm between the T-piece and the frame (see below). Sensor (1) Adjustment of spring holder Sensor Grub Screw (3) Sensor Grub Screw (2) 7.0: Maintenance 12 Small Gap of approx. 0.25 mm

7.0: Maintenance (continued) 4. Move the T-piece in by 2.65 mm. The T-piece must remain fixed in this position during the setting of electrical null. 5. Connect an oscillator supply to the sensor. 6. Monitor the output of the sensor on a DVM. 7. Adjust the position of the sensor relative to the frame to achieve minimum output on the DVM. Care should be taken not to rotate the sensor during this adjustment. This is electrical null. 8. Tighten sensor grub screw (2). 7.0: Maintenance (continued) 13

8.0: Specifications 8.1: Measurement Analogue Digital Measurement Range (mm) ±1.0, ±2.5 and ±5 2, 5 and 10 Mechanical Travel (mm) 3, 6 and 11 3, 6 and 11 Accuracy (1) 2 mm 5 mm 10 mm ±1.0 µm or ±0.5% x D ±2.5 µm or ±0.5% x D ±5.0 µm or ±0.5% x D (whichever the greater) at 5 khz for LVDT, at 10 khz for half 0.1 µm ±0.1% x D ±0.1 µm ±0.15% x D ±0.1 µm ±0.15% x D bridge Repeatability (on-axis at 70 g tip force) 2 mm 5 mm 10 mm 0.25 µm 0.25 µm 0.50 µm Resolution Dependent on Electronics User selectable to < 0. 1(µm) Null Position Adjustable Do Not Adjust Tip Force (2) 2 mm 5 mm 0.75 N minimum 10 mm Temperature Coefficient 2 mm 5 mm 10 mm ± 0.2 µm/ C ± 0.5 µm/ C ± 1.0 µm/ C Life Better than 5 million measuring cycles (dependent on application) 8.0: Specifications 14

8.0: Specifications (continued) Accuracies quoted are through the gauge centreline. Unplugged (free lead) and other specification available on request. (1) Accuracy includes both linearity and sensitivity errors (D is the distance from setting master). (2) Maximum tip force is 3.5 N. A selection of springs can be supplied for attitude and dead weight compensation. Care should be taken as the probe performance (accuracy and repeatability) may degrade at high tip forces. 8.0: Specifications (continued) 15

8.0: Specifications (continued) 8.1: Measurement Note 1: The linearity specification includes errors due to both linearity and sensitivity. Other manufacturers may quote these errors separately. These linearity specifications are substantially more demanding than the 0.25% full scale conventionally specified, as shown in the diagram below. The Digital Block Gauge specification includes the linearity and sensitivity for both the Block Gauge and the electronics. Solartron Analogue Block Gauge Specification Analogue µm 12.5 10.0 7.5 5.0 2.5 0-2.5-2.0-1.5-1.0-0.5-2.5 0.5 1.0 1.5 2.0 mm 2.5-5.0-7.5-10.0-12.5 0.25% of full scale output Digital µm 12.5 10.0 7.5 5.0 Solartron 2.5 Digital 0.0 0.5 1.0 1.5 2.0 3.0 3.5 4.0 4.5 mm 5.0 Block Gauge -2.5-5.0 Specification -7.5-10.0-12.5 Note: Example is for 5 mm Block Gauge 0.25% of full scale output Assumes setting master at mid stroke 8.0: Specifications (continued) 16

8.0: Specifications (continued) 8.2: Mechanical Mass (g / lbs) (Without toolholder) Mass of moving parts (g / lbs) Material 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm Analogue 160 g (0.352 lbs) 390 g (0.858 lbs) 385 g (0.847 lbs) 35 g (0.077 lbs) 90 g (0.198 lbs) 95 g (0.209 lbs) Stainless Steel (300 Series) with Viton Gaiters Digital IP Rating IP65 IP65 IP43 for electronics Operating Pressure 1 bar to 3 bar 8.3: Environmental Analogue 17 Digital Storage Temperature ( C) -40 to +85-20 to +70 Operating Temperature ( C) +5 to +85 +5 to +65 Shock 8.0: Specifications To maintain best performance, the Block Gauge should be protected from excessive shock loads and dropping

8.0: Specifications (continued) 8.4: Electrical Interface LVDT Analogue Half Bridge Digital Energising Voltage 1 to 10 Vrms 5 V ± 0.25 Vdc Energising Frequency 2 to 20 khz Not Applicable Energising Current 2 ma/v at 5 khz 2 ma/v at 10 khz 55 ma at 5 VDC Calibration Voltage 3 V Not Applicable Calibration Frequency 5 khz 10 khz Not Applicable Calibration Load 10 KΩ 2 KΩ Not Applicable Sensitivity (mv/v/mm) 2 mm 5 mm 10 mm 200 ±0.5% 80 ±0.5% 40 ±0.5% at 5 khz 73.5 ±0.5% 29.4 ±0.5% 14.7 ±0.5% at 10 khz Not Applicable Note: Operation outside of calibration voltage, frequency and load may degrade performance. 8.0: Specifications 18

9.0: Connections 9.1: Analogue Block Gauge LVDT Electrical Connections LVDT Case Cable Screen Note 1: + indicates forward movement of the tip. Note 2: The transducer body may be disconnected from the cable screen by cutting the black wire inside the connector. LVDT Electrical Connections Red & Blue Energising Green & White Signal Yellow Secondary Centre Tap Red & White In Phase for Inward Displacement 9.0: Connections Yellow Black White Green Red 19 Half Bridge Electrical Connections Half Bridge Case Cable Screen Blue Yellow Red Black Note 1: + indicates forward movement of the tip. Note 2: The transducer body may be disconnected from the cable screen by cutting the black wire inside the connector. Half-Bridge Electrical Connections Red & Blue Energising Yellow Signal Red & Yellow In Phase for Inward Displacement Black Transducer Body Ground

9.0: Connections (continued) 9.2: Digital Block Gauge PIE Pin assignment Pin Function 1 (none) 2 RS485(A) 3 RS485(B) 4 0V 5 0V 6 +5V 7 +5V 8 +5V 9 0V PIE can be fitted directly into the back of the Digital Readout or linked into the Orbit Network using the stackable T-CON connectors. 9.0: Connections 20

10.0: Outline Drawings 10.1: Mechanical Drawings 2 mm Block Gauge eg DK/2/S, BG/1/S CAD drawings can be downloaded from www.solartronmetology.com 10.0: Outline Drawings 21

10.0: Outline Drawings (continued) 10.1: Mechanical Drawings 5 mm Block Gauge eg DK/5/S, BG/2.5/S CAD drawings can be downloaded from www.solartronmetology.com 10.0: Outline Drawings 22

10.0: Outline Drawings (continued) 10.1: Mechanical Drawings 10 mm Block Gauge eg DK/10/S, BG/5/S CAD drawings can be downloaded from www.solartronmetology.com 10.0: Outline Drawings 23

10.0: Outline Drawings (continued) 10.2: Configuration Drawing 10.0: Outline Drawings 24