TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

Similar documents
255 Valve Specifications

Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

COMMERCIAL CONTROL VALVES. Magnum Control Valve

Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

255 Valve Specifications

wd-2

AUTOTROL 742/762 CONTROL 255 & PERFORMA SERIES VALVES (263, 268, 268 FA)

Operation Manual. 742/762 Control 255 and Performa Series Valves (263, 268, 268FA) For Sales & Service questions please contact your dealer:

Logix Magnum IT and Cv Valves. Installation and Service Manual

740/760 Control 255 and Performa Series Valves (268, 268FA)

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

Control Valves, Fittings and Accessories

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

Control Valves, Fittings and Accessories

COMMERCIAL UST ADD WATER BULLETIN; ISSUE 1

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Commercial Softeners

TNT SERIES WATER CONDITIONERS

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

Water Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

Assembled Engineered Systems. Softeners Filters Specialty Systems

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

SIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT WATER PURIFICATION VALVES - SIATA

BNT 85 /185 Valve Operation Manual

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

P/N: (Rev. G 1/19/10)

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

2inch Valve S D S D

Fleck Top Mount Section 1 Fiberglass Softeners

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Superior Water And Air

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

INSTRUMENTATION & CONTROL

Owner s Manual HELLENBRAND, INC.

PRESSURE GAGES AND TEST TAPS

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

GF Series Water Softener

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

IWT 565 Series Valve Operation Manual

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

Water Specialist WS2H and WS3 Control Valve Manual

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

CONTROLLERS & SPECIAL VALVES

TABLE OF CONTENTS. System Information...3. Pre-Installation Instructions...3. Installation Instructions Control Information...

Table of Contents. Operational Specifications Agency Approvals Regeneration Cycles Injector & Flow Control Selections...

Iron Blaster System Owner s Manual

65 Series. Valve Operation Manual

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

OWNER S MANUAL FOR ALL GREENSAND SYSTEMS

TotalCare Series. Water Conditioners

AquaMatic Series. A100 and A200 Stager Controls

Water Specialist 1.5" CC Control Valve Programming and Drawings Manual

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Water Specialist CI Control Valve Programming and Cover Drawing Manual

MGTE Series 1 1/2 Metered & Time Clock

Upper Distributor Prevents Loss of Resin to Service or Drain Flow Rates Up To 15 GPM. Clock is Simple to Set.

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Installation and Operations Manual

2400VS SERIES. Technical Manual. A Division of Aquion, Inc.

Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

AquaMatic Control Valves, Stagers and Controllers

or OWNER S MANUAL MODEL R

Water Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC

Control Valves - Fleck, Autotrol, Clack, AquaMatic & Others

Model 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

Fleck Epoxy Lined Section 2 Steel Softeners

Fleck 5600SXT Upflow. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Water Specialist PR Control Valve Programming and Cover Drawing Manual

TTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Water Specialist igen Control Valve Programming and Cover Drawing Manual

FLECK 2850 CONTROL VALVE

Water Specialist EE Control Valve Programming and Cover Drawing Manual

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

Installation and Operation Manual

Model 5600SXT Downflow

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

INSTALLATION, OPERATING AND SERVICE MANUAL

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

Transcription:

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TIMER CHARACTERISTICS 742 TIME CLOCK Electronic time clock (chronometric) 1- or 99-day regeneration setting (days interval) or days of the week 12 V operation Filter or conditioner setting in one control Fully programmable cycle times Salt setting in 10-grams increments Operates 255, 263, 268, 273, 278 and Magnum IT with one controller 762 DEMAND Simple, economic electronic demand (volumetric) Calendar override 12 V operation 28-day variable reserve Automatic capacity calculations Fully programmable cycle times Salt setting in 10-grams increments Operates 255, 263, 268, 273, 278 and Magnum IT with one controller 764 DEMAND Same features as the 762, plus: Multi-tank applications (twin alternating, multi-tank parallel) Control lockout Remote regeneration

TECHNICAL SPECIFICATIONS VALVE SPECIFICATIONS Valve Body Glass-filled thermoplastic NSF Listed material Rubber Components Compounded for cold water NSF Listed material Valve Materials Certification WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS Weight (Valve with Control) 2.42 kg (5.34 lbs) Recommended Operating Pressure 1.38-8.27 (20-120 ) Hydrostatic Test Pressure 20.69 (300 ) Water Temperature 2-38 C (35-100 F) Ambient Temperature* 2-48.9 C (35-120 F) Controller Operating Voltage 12 VAC (Requires use of Pentair-supplied transformer) Input Supply Frequency 50 or 60 Hz (Controller configuration dependent) Motor Input Voltage12 VAC Controller System Power Consumption 3 W average * Recommend use of outdoor cover for direct sunlight applications TRANSFORMER ALL CONTROLLERS Transformer Output Voltage 12 VAC 150 ma Transformer Input Options 230 VAC 50/60 Hz Transformer Plug Options United Kingdom Plug Mainland Europe Plug All Controllers require the use of a Pentair-supplied transformer. Additional transformers may be available call for more information. FLOW RATES (VALVE ONLY) Service @ 1.03 (15 ) drop 5.7 m 3 /h (25.0 gpm) Backwash @ 1.72 (25 ) drop 4.5 m 3 /h (20.0 gpm) Service Kv = 5.6 (Cv = 6.50) Backwash Kv = 3.5 (Cv = 4.00) VALVE CONNECTIONS Tank Thread Inlet/Outlet Threads Drain Line Brine Line Distributor Tube Diameter Distributor Tube Length 21/2 inches 8, male 13/4 inches 12 UNC-2A male 3/4 inch NPT, male 3/8 inch NPT, male 27 mm (1.050 inch) 13 ± 13 mm (1/2 ± 1/2-inch) above top of tank

OPTIONS Turbine for Demand Units Internal Standard Autotrol 25 mm (1-inch) turbine Bypass Valve, Model 1265 Thermoplastic, 1-inch flow path Bypass Fitting Kits: Copper, Sweat Tube Adapter 32, 25 or 19 mm (11/4, 1 or 3/4 inch) CPVC, Solvent Weld Tube Adapter 25 or 19 mm (1 or 3/4 inch) Plastic NPT or BSPT Pipe Adapter 25 or 19 mm male (1 or 3/4 inch) Stainless steel NPT or BSPT Pipe Adapter 25 or 19 mm male (1 or 3/4 inch) Brine Refill Controls 0.33 gpm (1.25 Lpm) fixed 0.74 gpm (2.8 Lpm) fixed; 1.3 gpm (4.92 Lpm) fixed DIMENSIONS Units A B C D E F G H I cm 37.8 19.9 17.9 21.5 12.7 13.5 14.8 8.7 8.7 inches 14.9 7.8 7.1 8.5 5.0 5.3 5.8 3.4 3.4 PERFORMANCE BACKWASH FLOW CONTROL FLOW RATE VS PRESSURE DROP Backwash number* Flow Rate (gpm) Flow Rate (Lpm) 7 1.30 4.90 8 1.70 6.40 9 2.20 8.30 10 2.70 10.20 12 3.90 14.76 Pressure Drop in 30 25 20 15 10 Flow Rate (m 3 /hr) 0 1.1 2.3 3.4 4.5 5.7 6.8 7.9 2.00 BACKWASH FLOW Cv = 4.00 SERVICE FLOW Cv = 6.5 1.75 1.50 1.25 1.00 0.75 0.50 Pressure Drop () 13 4.50 17.00 5 0.25 14 5.30 20.00 0 0 LWR 5730 0.00 5 10 15 20 25 30 35 *Backwash flow controls sized for 5.0 gpm/sq. ft. Flow Rate in Gallons Per Minute

INJECTOR* PERFORMANCE LOGIX SERIES CONTROLLERS Injector H (Light Purple) For 9-inch Tanks Injector J (Light Blue) For 10-inch Tanks TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE Injector K (Pink) For 12-inch Tanks Injector L (Orange) Injector N (Green) For 13-inch and 14-inch Tanks For 16-inch Tanks Injector Q (Purple) For 18-inch Tanks Injector R (Dark Grey) For 21-inch Tanks TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE *New injectors for high-efficiency regeneration sequence are standard with Logix Controllers. NOTE: Actual injector performance is dependent on the resin used, tank geometry, elevated drain, etc. This injector data was taken using an empty tank (no resin). MKT-TS-008-EN-B

www.pentairaquaeurope.com