lindab comfort Regula Control er

Similar documents
Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

LindabPodium. Supply air beam. lindab we simplify construction

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

RC-DO. Room controllers with display and manual forced ventilation function

Accessories STRA Room Controller

STRA-24 for chilled beams

Pressure Independent Control Valve

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

Condensation monitor

High Capacity Valve Body, Type RA-G

Actuator type ABNM with Theft Protection, 0-10 V Proportional

HERZ Electronic room thermostat analog and digital

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

CWK Circular duct coolers for cooled water

Actuator ABNM A V Proportional For Use with RA2000 Valves

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Functions Technical information - Actuator 24 V. Features. General information. lindab we simplify construction

VE-S_15-32 Pressure Independent Balancing & Control Valves

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Combi valves PN 16 with flanged connections

Overview of types. Technical data

PGK Rectangular duct coolers for cooled water

Control Solutions Biofloor

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

WAY MOTORISED COMPACT ZONE VALVES

Temperature Controller OVATION 214 User's Guide

NV Direct Coupled Globe Valve Actuator

LK Manifold Shunt VS 2-2,5

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

EMO TM. Actuators High performance proportional actuator For modulating control

Valves and Actuators

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

HS1L Interlock Switches with Solenoid

Pressure independent balancing and control valve

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technote. CirCon/TemCon - thermostatic valves for domestic hot water. Application. Advantages. Functions.

Power consumption In operation At rest For wire sizing. Non-operating temperature

SAX Electronic Valve Actuator

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

22C, 22CX, 22CX5, 26LC Series

See «Overview of types»

Terminator PICV. Technical Manual

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Electromotoric Actuators

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

LK Control v.3 & LK Control v.3 - RA

Air-Cooled Liquid Chiller with integrated hydraulic module

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

VE VVG Series Electronic Two-way Valves Normally Closed

Temperature Controller (Heat Pumps)

Paddle-wheel flow controller with optical principle for On/Off control

2-Port and 3-Port Zone Valves, PN16

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Flow switches Series AD/VH

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

RVP-R- VAV controller. In explosion-proof version

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

LK Manifold Shunt VS2

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

TZIM. Electropneumatic Analog Positioner 10/ EN

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Ventilation Control. Ventilation Control 12

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

Pressure independent balancing and control valve AB-QM DN

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

VACUUM PUMP P5010. Profit from new vacuum technology

SDS Enclosed Star-Delta Starter User Guide

TA-6-way valve. Standard control valves 6-way valve for change-over systems

Air damper actuators

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

DIFFERENTIAL THERMOSTAT

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Flash Point Process Analyzer

2-Port and 3-Port Zone Valves, PN 16 / 20

Manifolds series 73A and 77A. Instruction manual

Open Chassis Star-Delta Starter User Guide

ELECTRONIC THERMOSTAT: T901

HERZ Motorised Actuator

Room product for Swegon s WISE System for demand-controlled ventilation

High capacity valve body, type RA-G

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

Electromotoric Actuators

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Electronic Globe Valves

Transcription:

lindab comfort Regula Controller

Regula Controller Control equipment for waterborne cooling and heating systems. Use Regula Mono, Duo and Regula Lon control the cooling and heating of a room in sequence or separately. Regula Secura monitors condensation for safe and optimum operation. Regula Connect is a connecting card for adaptable connection to façade systems and chilled beams. Installation Regula Mono, Duo and Regula Lon can be integrated in an equipment box or directly on the wall. Regula Secura and Regula Connect are either integrated or surface mounted. Features User-friendly controller. Controls heating and cooling in sequence. Condensation monitor. 2

Regula controllers Lindab offers a special range of controllers for waterborne heating and cooling systems. A common feature is that the controllers are all user-friendly with optimum functionality for waterborne heating and cooling systems. Regula Duo controls heating and cooling in sequence while Regula Mono controls heating or cooling. Regula Mono and Regula Duo operate with the use of an ON/OFF control knob. Regula Lon is a zone controller with parameter settings in the Lon network. Communication is carried out in accordance with the LonMark Guidelines (Chilled Ceiling Controller 8070) to fully comply with LonMark certification. Cooling effect 0 % Room temperature P-band Desired value ON/OFF control PI control Room.temp. with PI control Room.temp. with ON/OFF control Time Time Figure 1. Principle comparison between the function of PI control and ON/OFF control. Regula Secura is a condensation monitor from Lindab that is compatible with Lindab s waterborne equipment. Regula Secura is mounted on the chilled beam or feed pipe of the equipment box for monitoring of condensation. When detecting condensation, the condensation monitor stops the signal to the actuator, temporarily closing the cooling valve. In the event of a power cut, the valve and actuator remain closed. Regula Secura can be used in combination with Regula Duo, Regula Mono or Regula Lon. General control functions The ON/OFF control knob provides a quick and reliable control process with minor temperature fluctuations, + 0.3 C. A PI controller is moderately slower with more noticeable temperature fluctuations. Dead zone 1 C Output On Heating Cooling Off 0.3 C 0.3 C Coupling diff. Heating output Coupling diff. Cooling output Figure 2. Control process using the ON/OFF control knob. Room temp. 22.4 22.2 22.0 Coupling difference 0.3 Room temperature ( C) 21.8 21.8 21.6 21.4 21.2 ON/OFF control PI control Coupling difference 0.3 Dead zone ON/OFF 1.0 Dead zone PI control 1.0 21.0 20.8 20.6 07:00 08:00 09:00 10:00 11:00 Time (h) Figur 3. Comparison of ON/OFF and PI control, when alternating between heating and cooling. 3

Regula Mono/Duo Function Regula Mono and Duo are designed for room/individual temperature control where the desired temperature can be adjusted + 4 C using the temperature control knob. Regula Mono/Duo can be integrated in an equipment box or directly on the wall. The controller is available in two models one for sequence control of heating and cooling (Regula Duo) and one for control of heating or cooling (Regula Mono). Where sequence controlling is used, Regula is connected with electrical cables to a number of actuators usually one for the cooling circuit and one for the heating circuit. A maximum of 10 actuators per output can be connected. The actuators are in turn mounted on heating and cooling valves that open and close the heating or cooling circuits depending on whether the room needs to be heated or cooled. The control signal governing this process is given from the integrated or external temperature sensor of Regula that compares the desired temperature with the actual temperature. The system continuously attempts to equalize these temperature values as quickly as possible. The control principle engaged for this is called two-step control. There is an integrated coupling difference to prevent the system from being activated too often by temperature fluctuations of less than 0.3 C between the desired and actual temperatures. The power supply required by Regula comes from a 24 V transformer. Regula Lon Function Regula Lon is a zone controller for installation in an equipment box or directly on the wall. Regula Lon is controlled using an integral or external sensor. The ON/OFF control knob controls 2 thermoelectric actuators for heating and cooling in sequence. Each output is controlled by a 24 V triac. In an analogue setting of PI control, 0 10 V outputs are used to control two thermoelectric 0 10 V actuators for heating and cooling in sequence (direct or reverse effect). The actuators can also be connected using a separate 24 V power supply. In addition, Regula Lon can be used to control a 3-point motor actuator for either heating or cooling. The controller is fitted with two inputs for the use of for example an external room sensor, movement detector, window connector, etc. The desired temperature is set in the Lon network and can be adjusted +3 C using the reference value adjustment knob. The lid has a builtin LED that illuminates in normal mode and flashes in by-pass mode. In addition, the lid has a LED indicating service and communication status. All parameter settings are carried out in the Lon network. Communication is carried out in accordance with LonMark Guidelines to fully comply with LonMark certification. 4

Design/Technical data Design Regula Mono Regula Duo Regula Lon Supply voltage 24 V AC ±15% 24 V AC ±15% 24 V AC ±15% Outputs 1 relay 2 relays 2 universal outputs, can be used for: 2 analogue 0 10 V DC, 1 ma or 24 V triac on/off or 1 three-point motor actuator Inputs 1 temperature sensor 1 temperature sensor 2 universal 1. Room sensor NTC or window connector (nonpotential connector) 2. Presence sensor (nonpotential connector) Installation In equipment boxes or surface mounted. Output signal 24 V / 2 A on-off. Max. 10 actuators on heating or cooling stages. Service life >200,000 connections Service life of over ten years. In equipment boxes or surface mounted. 24 V / 2 A on-off. Max. 10 actuators on heating or cooling stages. >200,000 connections Service life of over ten years. In equipment boxes or surface mounted. Outputs, see above. No moving components. Service life of over ten years. Temperature range 11-29 ºC 11-29 ºC Adjustable via the LON network. Midpoint reference value scale 21 ºC (adjustable 15-25 ºC) 21 ºC (adjustable 15-25 ºC) 0-30 ºC Adjustable via the LON network. Dead zone 1 ºC 1 ºC Adjustable via the LON network. Coupling difference 0.3 C 0.3 C Adjustable via the LON network. Power consumption 1 W 1 W 2 W Electrical connection Screw-in plinth Screw-in plinth or quick Screw-in plinth connection Size, controller 85 85 35 mm 85 85 35 mm 85 85 35 mm Housing ABS, white ABS, white ABS, white Protection class IP 20 IP 20 IP 20 Certification CE CE CE Ambient temperature 0 50 C 0 50 C 0 50 C Indication, heating Red signal Red signal Temperature via the Lon network Indication, cooling Blue signal Blue signal Temperature via the Lon network Reference value adjustment ±4 C using reference value adjustment knob ±4 C using reference value adjustment knob ±3 C using reference value adjustment knob 5

Electrical wiring diagram Mono 1 2 3 4 5 6 N * 24 V AC P 24 V AC Actuator 24 V * External sensor *= to connect the actuator Duo 1 2 3 4 5 6 N * 24 V AC P 24 V AC Actuator heating * Actuator cooling * External sensor Quick connection for heating and cooling actuators via Regula Connect Lon 1 2 3 4 5 6 7 8 9 10 Supply voltage 24 V AC System zero24 V AC Universal output 1 Universal output 2 Signal zero Universal input 1 Universal input 2 Lon Net A Lon Net B Earth Dimensions, mm 30 60 11 23 86 43 86 34,5 15 10 Loops 6 Thermostat Regula Mono BY1 BY2 BY3 Output 1 2 3 4 5 6 N 24V AC P 24V AC Actuator 24 V External sensor External sensor Internal sensor External sensor Cooling function Heating function Actuator normally closed(nc) Actuator normally open(no) Thermostat Regula Duo 1 N 24V AC 2 P 24V AC 3 Actuator heating 24V 4 Actuator cooling 24V 5 External sensor 6 External sensor BY1 BY3 Heating BY4 Cooling Internal sensor External sensor Actuator normally closed (NC) Actuator normally open (NO) Actuator normally closed (NC) Actuator normally open (NO) Thermostat Regula Lon 1 2 N P 24V AC 24V AC 3 4 Universal output 1 Universal output 2 5 Signal zero 6 7 8 9 10 Universal input 1 Universal input 2 Lon Net A Lon Net B Earth BY1 BY2 Y1, Digital output Y1, Analogue output Y2, Digital output Y2, Analogue output BY 3 and BY4 are not used in this application. They should always be set to the right.

Regula Secura Condensation control Lindab has developed a condensation control for chilled beams and façade systems. The condensation control is called Regula Secura. Since Regula Secura controls actual condensation, a higher efficiency is achieved compared with traditional humidity control. Traditional humidity controls usually measure the average level of humidity with the addition of a water temperature safety margin in order to avoid moisture precipitation. With Regula Secura, safety margins for sensor settings or thermal resistance in pipes are not necessary. In the event of condensation on the feed pipe, the cooler valve temporarily stops the water flow through the effected equipment. The protection provided by Regula Secura is individual for each chilled beam and façade system, consequently preventing damages due to condensation. Using the ON/OFF function, the condensation control continues to monitor the level of condensation, even below dew point, to allow for an optimal performance by the chilled beam or façade system. The diagram below shows an example of such a control sequence. Using Regula Secura on all chilled beams and façade systems increases the protection against condensation. Only units with moisture precipitation are shut down until the condensation has desiccated, leaving other units functioning as normal. This is particularly beneficial in room environments with varying temperatures or where there is a risk of outside moisture entering the room through open windows for example. Function Regula Secura controls the output signal to the actuator and only operates when there is a signal to the actuator to open the valve. Regula Secura is only activated if the control signal is for cool air. Regula Secura is fitted with a sensor on the feed pipe of the chilled beam or façade system. When the sensor detects condensation on the feed pipe, Regula Secura closes the valve until the condensation has desiccated. Regula Secura is compatible with electronic controls such as Regula Mono, Regula Duo or any other equipment using thermoelectric actuators. It is important to note that the valve and actuator close in case of a power cut. Controller Regula Secura 1 2 3 4 5 6 Schematic showing how to connect Regula Secura. Moisture sensor Actuator with valve Condensation control: 3.7 C below dew point 60 600 Room temp. ( C) Temperature ( C) / Humidity (%) 50 40 30 20 10 500 400 300 200 100 Effect (W) Inlet water ( C) Relative humidity (%) Dew point ( C) Effect (W) 0 0 00:00 02:00 04:00 06:00 08:00 10:00 12:00 Tid (h) The diagram above shows a control sequence with a water temperature of 3.7 C below dew point. Throughout the entire control process, the controller asks for cool air, which Regula Secura controls using the ON/OFF function. 7

Regula Connect Regula Connect is a connecting card that provides an adaptable connection of chilled beams or façade systems. Regula Connect consists of a connecting card with relay for main cables, thermostat cable and actuator cable plinths. The card has alternative main cable outputs for the control signal to be transmitted to the next chilled beam or façade system in both directions or up to the wall. In addition, a transformer is connected to unused port. The system consists of an apparatus cable, connection cable and thermostat cable. Switching control cables When moving, erecting new or removing existing partition walls, the control system can be switched over (see picture below) for the control to continue operating the equipment in the room in which it is installed. The apparatus cable is made up of four parts - two for feed supply and two for control signals to heating and cooling actuators. The following figures refer to the pictures below. 1-2 Connector for connection and relay within the same control zone (feed supply and control signals). 3-4 Connector for connection and relay to another control zone (only feed supply). 5 Connector for connection of room thermostat (for monitoring of control zone). 6 Plinth for connection of actuator. Heating and cooling. 1 3 5 2 4 6 8

Actuators and valves The thermoelectric actuator is either fully open or fully closed. The advantages of this are: 1. When the valve is open, full flow always passes through the products, which ensures the stated cooling effect and function. The temperature increase in the room is counteracted quickly, which gives a more comfortable climate. Using fully opened valves you are ceratin of getting the right cooling effect, despite the dimensioned heating load not prevailing in the building. 2. The risk of blockage due to contaminated pipes is reduced. Adaption to different valves The regulating equipment is based on the use of nonpressure valves (heat valves) for regulating both cooling and heating. The actuators match most valves available on the market. Specify in the programme text to which valves the actuator should be matched. The actuator mounted on the valve. Actuators (NC) and valves with valve function are usually supplied closed in a non-current mode. The pipe fittings shown in the picture can be ordered separately. Normally open or closed actuators Regula can control normally open (NO), or normally closed (NC) actuators. Regula is supplied with settings for an NC type actuator. There is a change-over switch for actuator type NC or NO beneath the openable lid. Number of actuators per Controller Up to 10 actuators can be connected per output (cooling or heating) per Controller. When connecting several actuators, a connection box should be used due to space requirements. Miscellaneous There is an indicator on the valve that shows when it is open or closed. The acuator is supplied locked with a "first time" function in an open position. When a voltage is fed to the actuator on starting up for the first time (minimum 6 minutes), this function is annulled. The actuator is then ready for use. This can facilitate filling-up and ventilation of the cooling system. Actuators are supplied with a 1 m non-halogen cable. 9

Technical data, actuators & valves Lindab s standard actuators are of the type 24 V NC (normally closed). Supply voltage: 24 V AC/DC Power consumption: 80 ma, initially max. 250 ma Power, operation: 2 W Opening/Closing time: Approx. 3 min Actuating power: 90 N Cylinder stroke: Approx. 3 mm Ambient temperature: 0 50 C Protection class: IP 40 Pressure drop diagram Lindab s standard valves are 2-way FVR valves. Water temperature: 2 90 C Kvs value (fully open valve): 0.01-1.2 (FVR 10,15, 20) Pressure category: PN10 Max. differential pressure (across product and valve): 20 kpa Max. closing pressure: 250 kpa Cylinder stroke: 1.7 mm Material: Brass Please contact Lindab for information about other types of actuators and valves. Kv 4.0 3.0 2.0 Kv (2 C) 4.0 3.0 2.0 Opening rate for Kvs (fully open valve) 1.0 0.5 0.4 0.3 0.2 0.1 kpa 0.5 kpa 1 kpa 5 kpa 10 kpa 50 kpa 1.0 0.5 0.4 0.3 0.2 3.0 2.5 2.0 1.5 3.0 2.5 2.0 1.5 0.1 0.1 0.05 0.04 0.03 0.05 0.04 0.03 1.0 1.0 0.02 0.02 0.5 0.5 0.01 1 2 3 4 5 10 20 30 4050 0.0005 0.001 0.005 0.01 0.05 0.1 l/s Flow Flöde 100 200 500 0.01 l/h FV.. 10 FV.. 15/20 10

Calculating the transformer size Conditions The transformer size is calculated by taking the most heating or cooling actuators in the building or zone into consideration. Consumption when opened is 6 W and in a steady state 2 W. The calculation must take into cosideration whether the total power consumption is higher/ lower when opening and when at a steady state, respectively. Example 15 cooling actuators and 25 heating actuators are installed in the building/zone. Number of heating actuators dimensioned = 25. Consumption at start is: 6 W x 25 actuators and at a steady state 2 W x 25 actuators. We calculate the following in accordance with the formula P = U x I: 6 W/24 V = 0.25 A per actuator. 25 x 0.25 A = 6.25 A. Gives a transformer size of 6.25 A x 24 V = 150 VA. Other Designation Product designation: Type: Programme text Regula Mono, Duo, Lon, Connect or Secura Controller from Lindab Climate Qty Regula Duo 20 Regula Mono 10 Regula Secura 30 Regula Connect 5 Actuator for cooling 24 V NC 30 Actuator for heating 24 V NC 30 2-way valve FVR-15 60 Transformer 150 VA 1 Remember to add all actuators if for example NO actuators are used for heating and NC actuators are used for cooling. RC Regula Duo for sequence control of heating and cooling. 11

www.lindab.com Subject to alteration without prior notice. Photographer Marléne Hamström. November 2003.