Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Similar documents
Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type VSD35. Nominal length up to 1500 mm: one spigot

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers Type RN

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

CONSTANTFLOW Volume Flow Controllers

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Ceiling swirl diffusers with perforated face plate

VARYCONTROL VAV Dual Duct Terminal Boxes

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Slot diffusers for ceiling installation

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Volume Flow Limiters Type VFL

For installation into ductwork

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Ceiling swirl diffusers

Multileaf damper with actuator

VAV TERMINAL BOXES TYPE: BA BT

Technical documentation

VAV Terminal Units SDS

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Ceiling swirl diffusers with perforated face plate

TYPE EK-EU SMOKE CONTROL DAMPER

Fan - Powered Terminal Unit Series Flow

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling swirl diffusers

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Mechanical mixing box MBM

Pressure relief dampers

VAV controller. TROX Auranor Norge AS. Telephone Fax

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Air diffuser system Model AUDIX -AW

Ventilation grilles for installation into walls, sills or rectangular

Air distribution product

Ventilation grilles for installation into walls, sills or rectangular

Technical information

[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)

Ceiling swirl diffusers

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Waterside Fancoil Units

Variable Air Volume Dampers

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type Pneumatic actuators

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Waterside Fancoil Units

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

series RVV Variable flow rate controllers

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Transcription:

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly effective integral attenuator Box style construction for the reduction of the airflow velocity Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL) Suitable for airflow velocities up to 13 m/s Closed blade air leakage to EN 1751, class 4 Casing air leakage to EN 1751, class A Optional equipment and accessories Acoustic cladding for the reduction of case-radiated noise Secondary silencer Type TS for the reduction of air-regenerated noise

Application VARYCONTROL VAV terminal units of Type TVA for the extract air flow control in variable air volume systems Closed-loop volume flow control using an external power supply Integral attenuator for demanding acoustic requirements Shut-off by means of switching (equipment supplied by others) Special features Integral attenuator with at least 26 db insertion loss at 250 Hz Hygiene tested and certified Factory set-up or programming and aerodynamic function testing Volume flow rate can later be measured and adjusted on site; additional adjustment device may be necessary Nominal sizes 125, 160, 200, 250, 315, 400 Variants TVA: Extract air unit TVA-D: Extract air unit with acoustic cladding Units with acoustic cladding and/or secondary silencer Type TS for very demanding acoustic requirements Acoustic cladding cannot be retrofitted Parts and characteristics Ready-to-commission unit which consists of mechanical parts and control components. Averaging differential pressure sensor for volume flow rate measurement Damper blade Integral attenuator Factory-assembled control components complete with wiring and tubing Aerodynamic function testing on a special test rig prior to shipping of each unit Set-up data is given on a label or volume flow rate scale affixed to the unit High control accuracy even in case of unfavourable upstream conditions Attachments Easy controller: Compact unit consisting of controller with potentiometers, differential pressure transducer and actuator Compact controller: Compact unit consisting of controller, differential pressure transducer and actuator Universal controller: Controller, differential pressure transducer and actuators for special applications LABCONTROL: Control components for air management systems

Accessories Lip seal (factory fitted) Useful additions Secondary silencer Type TS Construction features Rectangular casing Spigot on the fan end suitable for circular ducts to EN 1506 or EN 13180 Spigot with groove for lip seal Connection on the room end suitable for air duct profiles Baffle plate is fitted after the damper blade for optimum aerodynamic performance Position of the damper blade indicated externally at shaft extension Thermal and acoustic insulation (lining) Materials and surfaces Casing and damper blade made of galvanised sheet steel Damper blade seal made of TPE plastic Lining is mineral wool Differential pressure sensor made of aluminium Plastic bearings Variant with acoustic cladding (-D) Acoustic cladding made of galvanised sheet steel Lining is mineral wool Rubber elements for the insulation of structure-borne noise Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 20 m/s Inert to fungal and bacterial growth Standards and guidelines Hygiene conforms to VDI 6022 VDI 2083, air cleanliness class 3, and US standard 209E, class 100 Closed blade air leakage to EN 1751, class 4 (nominal sizes 125 and 160, class 3). Nominal sizes 125 and 160 meet the general requirements, nominal sizes 200 400 meet the increased requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage Casing air leakage to EN 1751, class A

Maintenance Maintenance-free as construction and materials are not subject to wear TECHNISCHE INFORMATION Function, Technical data, Quick sizing, Specification text, Order code, Related Products Variants, Attachments, Dimensions and weight, Product details Installation details, Basic information and nomenclature Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 19/04/2019 TROX Italia S.p.A.

TROX Italia S.p.A. Online-Services Service-Hotlines TROX Academy Your contact partner Online fault report Telefono +39 02-98 29 74.1 Telefax +39 02-98 29 74 60 TROX NEI SOCIAL WEB Società unipersonale soggetta a direzione e coordinamento di TROX GmbH Sede legale: Via Mecenate 90-20138 Milano Cap. Soc. EUR 2.000.000 R.E.A. n. 659693 Reg. Impr. MI, C.F. e P.IVA IT 00897380150 Casella di posta certificata: trox@pec.it Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 19/04/2019 TROX Italia S.p.A.