Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Similar documents
Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Parts and characteristics

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Multileaf damper with actuator

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CONSTANTFLOW Volume Flow Controllers

CAV controllers Type RN

Type VSD35. Nominal length up to 1500 mm: one spigot

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Ceiling swirl diffusers with perforated face plate

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

VARYCONTROL VAV Dual Duct Terminal Boxes

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Slot diffusers for ceiling installation

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Fan - Powered Terminal Unit Series Flow

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

For installation into ductwork

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Volume Flow Limiters Type VFL

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

VAV TERMINAL BOXES TYPE: BA BT

TYPE EK-EU SMOKE CONTROL DAMPER

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

VAV Terminal Units SDS

Ceiling swirl diffusers

Pressure relief dampers

Technical documentation

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Ventilation grilles for installation into walls, sills or rectangular

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Technical information

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Type Pneumatic actuators

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

VAV controller. TROX Auranor Norge AS. Telephone Fax

Pressure control damper ERPA

Ceiling swirl diffusers with perforated face plate

Type Pneumatic actuators

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Variable Air Volume Dampers

Waterside Fancoil Units

Waterside Fancoil Units

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)

Marine Fire and Gas Dampers

MOTORIZED VOLUME DAMPER

RETROFIT TERMINAL UNITS

Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy.

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Mechanical mixing box MBM

Transcription:

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume systems, demanding acoustic requirements and low airflow velocities Highly effective integral attenuator Optimised for airflow velocities of 0.7 6 m/s High control accuracy even in case of unfavourable upstream conditions Compact construction with rectangular connections on both ends Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL) Closed blade air leakage to EN 1751, class 4 Casing air leakage to EN 1751, class B Optional equipment and accessories Acoustic cladding for the reduction of case-radiated noise Secondary silencer Type TS for the reduction of air-regenerated noise

Application VARYCONTROL VAV terminal units of Type TA-Silenzio for the extract air flow control in variable air volume systems with low airflow velocities Closed-loop volume flow control using an external power supply Integral attenuator for demanding acoustic requirements Shut-off by means of switching (equipment supplied by others) Special features Hygiene tested and certified Direct connection of ducting Factory set-up or programming and aerodynamic function testing Volume flow rate can later be measured and adjusted on site; additional adjustment device may be necessary Nominal sizes 125, 160, 200, 250, 315 Variants TA-Silenzio: Extract air unit TA-Silenzio-D: Extract air unit with acoustic cladding Units with acoustic cladding and/or secondary silencer Type TS for very demanding acoustic requirements Acoustic cladding cannot be retrofitted Parts and characteristics Ready-to-commission unit which consists of mechanical parts and control components. Averaging differential pressure sensor for volume flow rate measurement Damper blade Integral attenuator Factory-assembled control components complete with wiring and tubing Aerodynamic function testing on a special test rig prior to shipping of each unit Set-up data is given on a label or volume flow rate scale affixed to the unit High control accuracy even in case of unfavourable upstream conditions Attachments Easy controller: Compact unit with potentiometers Compact controller: Compact unit consisting of controller, differential pressure transducer and actuator Universal controller: Controller, differential pressure transducer and actuators for special applications LABCONTROL: Control components for air management systems Useful additions

Secondary silencer Type TS Construction features Rectangular casing Replaceable seals Flanges on both ends for connection to ductwork Position of the damper blade indicated externally at shaft extension Thermal and acoustic insulation (lining) Materials and surfaces Casing made of galvanised sheet steel Damper blade and differential pressure sensor made of aluminium Lining is mineral wool Plastic bearings Variant with acoustic cladding (-D) Acoustic cladding made of galvanised sheet steel Lining is mineral wool Rubber elements for the insulation of structure-borne noise Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 20 m/s Inert to fungal and bacterial growth Standards and guidelines Hygiene conforms to VDI 6022 VDI 2083, air cleanliness class 3, and US standard 209E, class 100 Closed blade air leakage to EN 1751, class 4 Meets the increased requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage Casing air leakage to EN 1751, class B Maintenance Maintenance-free as construction and materials are not subject to wear TECHNICAL INFORMATION

Function, Technical data, Quick sizing, Specification text, Order code, Related Products Variants, Attachments, Dimensions and weight, Product details Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 19.04.2019 TROX Malaysia Sdn Bhd.

Installation details, Basic information and nomenclature TROX MALAYSIA SDN. BHD. Online-Services Service-Hotlines Your contact partner Online fault report Locations Malaysia Main Office and Factory Number Tel: +60 6 678 8188 Fax: +60 6 678 8288 / 388 TROX IN SOCIAL WEB 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Malaysia Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 19.04.2019 TROX Malaysia Sdn Bhd.