MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

Similar documents
MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

INSTRUCTION MANUAL SINKER. By HAY

SLIMFLEX LED Tape Lighting

12V Monorail PLANNING & INSTALLATION GUIDE. Sensibly Contemporary

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

EMERY SKY SUSPENDED LED LUMINAIRE

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Wireless Dimmer Installation and User Guide

Installation Manual. CS9300 Professional Series Landscape Lighting System

WARNING. Important Notice

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

The Gallery System DIRECTIONS. Components of the System

HPNLS-HO. Installation Manual

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

PIL0478 ISSUE 01/ 07/16

Compose GYPSUM Mud-In

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TWO - C IR CU I T MONORAI L

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION W Track Suspension system

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Installation Instruction ALG Series LED Area Light Version: 3.1

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (24V)

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

Installation Guide The RSi brief overview:

Installation Instructions: ACCENT SYSTEM

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

MOUNTING SYSTEMS SPECIFICATIONS

12V Track System. Metal Glass Pendant. 12V Track Lighting Systems. Versatile low voltage lighting system with flexible track, ceiling or wall mounted

NT-300 Series Single Circuit Track System & Accessories

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Installation Instructions

ALL W INSTALLATION INSTRUCTIONS

Measurements are expressed in millimeters.

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)

Installation Instructions

O W N E R ' S M A N U A L

Installation Instructions

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

channel damage the internal components and the weight may break the internal wiring or flexible strip.

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

Product Manual Manuel du Produit Manual del Producto

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Operating Instructions

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ALL700RM-230V INSTALLATION INSTRUCTIONS

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

SloanLED THINLED. Constant Current. Installation Guide

General Installation Instructions LED

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

our top 5 faqs Read more frequently asked questions at integral-lighting.com.

The Da-Lite Difference.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Installation Instructions Table of Contents

LED OUTDOOR WALL MOUNT LANTERN

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Multiquip Submersible Pump Model ST-3050D

PIPELINE 1 SUSPENSION UP OR DOWN WITH POWER - END FEED

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Underwater Pool Color-Changing LED Light

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

Electric Vehicle Charging Station

Motion and Light Sensor Kit LHBAS51

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Customer service: or Upper mounting ring. Canopy

High Bay Luminaire Series

INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Operating Instructions

Operating Instructions Series L 4000 Spring Driven Cord Reels

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Instruction/Installation Manual

DUALBRITE Motion Sensing Coach Light

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

4000 SYSTEM OPERATING MANUAL

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

The Da-Lite Difference.

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Installation Instructions

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

ELECTRICAL. 60 Minutes

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Transcription:

MONORAIL KITS PENDANTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved.

IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following instructions completely before installation. 1. All electrical power must be turned off before installation or modification of an exixting system 2. The Monorail system cannot be installed in a damp or wet location 3. Monorail fixtures cannot be installed within 6 of combustible materials 4. Monorail cannot be concealed or extended through a building wall We recommend that the Monorail System be installed by qualified, licensed electrician INSTALLING MONORAIL 1. Start by placing the system on the floor, to roughly indicate the positions of the transformer, connectors, and standoffs. 2. Install Supplied Surface Mounted Transformer: If Surface Mounted Transformer is installed The standard Surface Mounted Transformer is compatible with 3 standoffs. For longer drops, install the POWER FEED CABLE EXTENDER now. Mount transformer to the junction box. If optional Remote Transformer is installed Determine location of transformer, J-box and canopy. Pull the appropriate THHN wire from the transformer to the canopy refer to the Voltage Drop Chart below. If using a SINGLE POWER FEED CANOPY, you will require two leads; if using a DUAL POWER FEED CANOPY, four leads are required. If using a POWER FEED EXTENSION, install it now. You will need one POWER FEED EXTENSION for a SINGLE POWER FEED CANOPY, or two POWER FEED EXTENSIONS for a DUAL POWER FEED CANOPY. Install canopy at the junction box. 3. Design bends and assemble rail on the floor. Bend Rail to desired shape. A BENDING TOOL may be used for more precise bends. Connect sections of Rail with connectors, ensuring tight connections. Where power is to be isolated, use non-conductive connectors. For a finished look, insert end caps over the ends of the Rail. 4. Install Standoff Supports Mark the ceiling locations where the standoff supports are to be installed. Standoffs should be placed about three feet apart, with more frequent suspensions on tight curves. The Surface Mounted Transformer itself is a standoff. Install Standoff supports. 5. Install Rail Install Rail to the Standoffs and Surface Mounted Transformers. Ensure that all power connections are tight and secure. Turn the power on. Using a Voltmeter, be sure that the Rail is supplying the proper voltage. Turn the power off. 6. Install Quick Adapt Pendants or Quick Adapt Spots Install the MA-FA (FIXTURE ADAPTER) on to the Rail where the Pendants or Spots are to be positioned. You will need one per Pendant or Spot. Install Pendants or Spots onto the MA-FA (FIXTURE ADAPTER).

Be sure that the power connections are tight and secure. Note: When using a 24V transformer, 24V lamps are required. Check for any connections that are hot to the touch. (Warm to the touch is not a problem). If any part of the system is hot, the connections must be re-tightened. 7. Test the Monorail System Turn the power on for 20 minutes. Note: All halogens lamps generate heat. Do not touch lamps with bare hands. 4. Install Standoff Support 2b. Install Optional Remote Transformer 3. Design Bend & Assemble Rail on the Floor 2a. Install Surface Mounted Transformer 1. Lay system out on floor 5. Install Rail to Power Feed & Standoffs 6. Install Quick Adapt Pendants 7. Test Monorail System For 20 Minutes

LOW VOLTAGE MONORAIL BASIC COMPONENTS CAUTION Read all instructions before attempting to install this product. Ensure main power is off before attempting to install, modify, or wire this product. Do not install in a wet or damp location. All electrical equipment should be installed by a qualified electrician or technician in accordance with local electrical codes and National Electrical Code. NOTE: Configure design and layout of system on floor before attempting to install any of the following products. MA FA Fixture Adapter 1. Unscrew cap from Fixture Adapter. 2. Insert Fixture Adapter onto installed Monorail system. 3. Replace cap onto Fixture Adapter and tighten. MA I Conductive Connector & MA-I-NC Non-Conductive Connector 1. Insert rail into open connector end. 2. Ensure the rail is set completely within the connector. 3. Tighten setscrew with Allen wrench. (Included) 855-592-0029 Instruction sheet subject to change without prior notice Rev 79 10/21/2013 Page 1 of 5

LOW VOLTAGE MONORAIL BASIC COMPONENTS CAUTION Read all instructions before attempting to install this product. Ensure main power is off before attempting to install, modify, or wire this product. Do not install in a wet or damp location. All electrical equipment should be installed by a qualified electrician or technician in accordance with local electrical codes and National Electrical Code. NOTE: Configure design and layout of system on floor before attempting to install this product. Cap to Power Feed Connection 1. Unscrew the cap from the power feed. 2. Slightly loosen the set screw on the cap, DO NOT REMOVE IT. 3. Place the Monorail into the power feed. 4. Tighten the cap to the power feed. Make sure the cap is not cross threaded. 5. Tighten the set on the cap firmly for proper power connection. 855-592-0029 Instruction sheet subject to change without prior notice Rev 79 10/21/2013 Page 4 of 5

LOW VOLTAGE MONORAIL BASIC COMPONENTS CAUTION Read all instructions before attempting to install this product. Ensure main power is off before attempting to install, modify, or wire this product. Do not install in a wet or damp location. All electrical equipment should be installed by a qualified electrician or technician in accordance with local electrical codes and National Electrical Code. NOTE: Configure design and layout of system on floor before attempting to install this product. Quick Adapt Connector Field Cut Instructions 1. Locate the Quick Adapt connector at the top of the coaxial cord. Completely remove screws A and B with the provided Allen key. 2. While holding the tip of the Quick Adapt connector, remove the base by turning it away from you. 3. You can now identify the three components that make up the Quick Adapt connector. 4. Disassemble the Quick Adapt connector by pulling the coaxial cord out of and away from all three components. 5. Measure the desired length and cut the cord. (Note: Approx. 1 inch of the cord will be inserted into the Quick Adapt connector). 6. Once you ve cut the cord to it s desired length, I will look like picture A shown to the left. Peel back the braided jacket approx.. ¾ from the tip of the insulated center wire (Picture B). 7. Cut off the excess braided jacket so that ¾ of the insulated center wire is exposed. Strip no more than 1/8 off of the insulated center wire. 8. Twist the remaning braided jacket snugly around the center wire to ensure a clean insertion around the center wire to ensure a clean insertion into the Quick Adapt connector. 9. Reassemble the Quick Adapt connector by passing the cord throught the retainer and sleeve first. Then insert the cord into the turn plug making sure that the foot of the plug covers the braided jacket. Turn the plug while inserting the cord for an easier insertion. Make certain you can see the center wire at the top opening A of the plug to ensure a good connection. 10. Again using the provided Allen key, tighten screw A at the tip of the plug. Reattach the sleeve and retainer to the plug. Tighten screw B on at the retainer. Your Quick Adapt Pendant is now ready to one of many mounting options in out Quick Adapt System. 855-592-0029 Instruction sheet subject to change without prior notice Rev 79 10/21/2013 Page 5 of 5

TROUBLESHOOTING Is a Quick Adapt Pendant or Quick Adapt Spot not functioning properly? Make sure the lamp is installed properly. Make sure the lamp is not burned out. Make sure the MA-FA (Fixture Adapter) is tightly connected. Did the breaker on the main panel trip? Verify that the circuit is not overloaded. required. When using an optional remote low voltage magnetic transformer, a low voltage magnetic dimmer is required. Make sure that dimmer s rated capacity is not exceeded. The dimmer is installed to the 120V side, before the transformer. Using an incorrect dimmer will significantly reduce the life of the transformer. Is the system still not working? Make sure the light switch is turned on. Make sure the transformer has a secure connection to the power feed and is properly and securely connected. Make sure all connections do not have any loose wire nuts. Make sure the input wire in the transformer is connected to the 120V. Dimming All JESCO Lighting electronic transformers may be dimmed with the appropriate dimmer. When using a low voltage electronic transformer, a low voltage electronic dimmer is Noise Reduction Dimming a transformer can sometimes cause a slight buzzing noise. In some applications, this may not be an issue. Following are some recommendations to reduce the buzzing noise: Make sure a compatible dimmer is being used. Install a debuzzing coil. Power the system up to 80% of capacity, for example, for a 300 watt transformer, do not load more than 240 watts. VOLTAGE DROP CHART Using this chart to determine the correct THHN size for an acceptable 3 percent drop in voltage at the specified wattage. The length shown is the length of wire from the remote transformer to the electrical J-box. 5 ft. 6-15 ft. 16-20 ft. 21-40 ft. 41-60 ft. 61-90 ft. 12 VOLT 150 watt 300 watt 12 ga. 10 ga. 8 ga. 1 ga. 2 ga. 1/0 ga. 1 ga. 3/0 ga. 24 VOLT 300 watt 600 watt 1 12 ga. 12 ga. 8 ga. 10 ga. 2 ga. 1 ga. NEW YORK 66-25 Traffic Avenue Glendale, NY 11385 Tel: 718.366.3211 or 800.527.7796 Fax: 748.366.3646 or 855.265.5768 LOS ANGELES 219 South 6th Avenue City of Industry, CA 91746 Tel: 626.333.3661 or 855.654.0110 Fax: 626.333.2955 855.592.0029 or