VSCP Vertical Suspended Column Pump Operation & Maintenance Manual

Similar documents
Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

END SUCTION CENTRIFUGAL PUMPS

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

VERTICAL POWER WASHER PUMP

Operation & Maintenance Manual ESSCO Pump

END SUCTION CENTRIFUGAL PUMPS

NECO Pumping Systems

SERIES PC INSTRUCTION AND OPERATION MANUAL

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

PROCESS PUMPS (INDIA) PVT LTD

Series Base mounted pump. Installation and operating instructions

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

MODEL 442 MODEL 492 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HORIZONTAL SPLIT CASE SPLIT CASE FIRE PUMP FOR

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

KLW4000D Multi-Port Power Pack

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Operating Manual Includes Pumps: PG-9000 Part #R809606

Installation Operation & Maintenance Manual. High Vacuum Lubricated Rotary Vane Pumps

Installation & Operating Manual

Air / Hydraulic Under Axle Jack

Amerigear SF Spindle

YEOMANS WET PIT PUMPS

Owners Manual: - Pumps

Amerigear SL Spindle

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

Voltmaster Centrifugal Trash Pumps

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

HYDRAULIC SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: HS2000 = 4.8 LBS. (2.17 Kg) HS3000 = 22 LBS. (9.98 Kg)

Installation Operation and Maintenance Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

End Suction Centrifugal

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Under Axle Jack Max. Capacity: 25 Tons

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

S3 General Installation

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Operating instructions Form no safety definitions

SUPERIOR PERFORMANCE

D-Series Blowers and Exhausters

HORIZONTAL SPLIT CASING PUMP


barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

ROYAL Cyclone 1 Extruder Operators Instruction Manual

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

Operating Instructions 20 Ton Air/Hydraulic Service Jack

OPERATING INSTRUCTIONS ZDX 7-1/2AS

Installation and Service Instructions. ST Series Pumps

User s Manual D-Series Blowers and Exhausters

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OPERATING INSTRUCTIONS ZDX 1/12CS

WELDING FUME EXHAUSTERS & ARMS

PROCESS PUMPS (INDIA) PVT LTD

PL Submersible, Semi-Vortex, Water Feature Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Marlow Series Cast Iron Swimming Pool Pumps

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

PROCESS PUMPS (INDIA) PVT LTD

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

INSTRUCTION SHEET FOR LOCK NUT CYLINDERS

WKLV Multi-Stage Oil Pump 42V Oil Lubricated Mechanical Seal

INSTALLATION AND OPERATING INSTRUCTIONS. EXP Hurlcon Pumps CTX Series & BX Series. Bolero ND Cleaner

3-Way Ball Valve Type 23H

Series Base mounted pump. Installation and operating instructions

Table of Contents Illustrations

1750 RPM Centrifugal Pumps

Operation & Service Manual

SERVICING INSTRUCTIONS

Air-Assist Service Jack Max. Capacity: 10 Tons

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

SUMMIT PUMP. Model SP Single Stage, Horizontal Slurry Pump, Installation, Operation, and Maintenance Manual

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

Instruction Manual. * We reserve the right to amend specification without prior notice.

Air / Hydraulic Pump

Instruction Manual. * We reserve the right to amend specification without prior notice.

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Instruction Manual. Single Acting, Aluminium, Locking Collar Hydraulic Cylinders ARSLC Series. Maximum Operating Pressure 700 bar

Centrifugal PTO Pumps. 2 nd Edition

1750 RPM Centrifugal Pumps

PROCESS PUMPS (INDIA) PVT LTD

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

Service Bulletin Winter Storage. All Carbureted Engines. 1. Stabilize Fuel. 2. Change Engine Oil and Filter 3.

Designed to Meet Your Specifications! USER MANUAL INSTALLATION OPERATION MAINTENANCE

Transcription:

Issue Date: January 1980 PUMP IDENTIFICATION Congratulations! You are the owner of the very best Column pump commercially available. With proper care and maintenance it will provide you with reliable service for many years. ESSCO pumps are of the heavy duty design. ESSCO offers a wide variety of impeller designs to allow for equipment flexibility. ESSCO pumps are ideally suited for applications such as sewage, grit (heavy and/or fine), slurry, food waste handling, food handling and a variety of other services. This manual applies to: All sizes of vertical suspended column pumps regardless of liquid end type. PUMP DESCRIPTION CAUTION NOTES AND STORAGE OF PUMPS These instructions apply to the pump only and are intended to be general and not specific. If the operating conditions change, refer to the factory or local fac- tory representative or distributor for reapplication. If the pump is not to be installed and operated immediately, it should be stored in a clean, dry place. ESSCO assumes the units will be placed in operation a few weeks after shipment and no special protection is given the pump, drive or motor. The shaft should be rotated once every two weeks. All exposed, unpainted surfaces should be protected from rust. Always refer to the manuals provided by manufacturers of the other equipment for their separate instructions and maintenance schedules. CAUTION IMPORTANT SAFETY NOTICE The installation, use and operation of this type of equipment is affected by various federal, state and local laws and the regulations concerning OSHA. Compliance with such laws relating to the proper installation and safe operation of this type of equipment is the responsibility of the equipment owner and all necessary steps should be taken by the owner to assure compliance with such laws prior to operation of the equipment.

Caution: Be sure to follow all safety requirements for the area you are working in. Good safety procedure dictates that the motor assembly should be removed from the pump and the electrical wiring be removed by a qualified electrician and the assembly taken to a proper repair facility. All work must be done in a well ventilated area. Do not change the seal in a confined space! Before Installation 1. Tighten all bolting snugly. 2. When moving the pump while in a horizontal position, complete support must be given to column, case and motor mount, to prevent damage from a bent shaft or column. 3. Rotate by hand. If the unit appears to be binding, it could be due to the impeller touching the back plate or suction plate (Non Clog pump only). Loosen the top impeller adjusting locknut on the shaft. Tighten lower locknut until the impeller is drawn up against the back plate, and then loosen 1.5 turns. If the unit still binds after impeller adjustment it may indicate a bent shaft, or stress in the column. Do not operate until binding has been eliminated. 4. Check all lubrication lines to be sure they are tightly connected to appropriate bearing. Check lines for damage, and replace if dented or damaged in any other way. Installation 1. After the unit is in a vertical position, remove the shipping supports and all strapping. Lower carefully into wet well. 2. Adjust discharge pipe locknuts, if necessary, so that there is no load on the case or column. Column must be absolutely vertical, or plumb. It may be necessary to shim the mounting plate to get to a plumb positions. COLUMN PUMP MUST BE PLUMB AND ALL PIPING STRAIN RE- MOVED FROM THE PUMP, OR PUMP WILL BE DAMAGED IN OP- ERATION.

3. After column is plumb, secure anchor bolts. 4. Bearing lubrication. a. If lower bearing is rubber, connect water line to lower bearing mounting plate connection. If a valve is used to control the water, the valve must be opened before starting to insure that water is in the bearing. If a solenoid valve is used, it should be set to open before the motor starts, and close after the motor stops. b. If a bronze lower bearing is used, the mounting plate connection will be a grease fitting. A grease similar to Mobilux EP No. 2 should be used. c. If intermediate oil lubricated bearings are used, fill oil reservoir with SAE 30 W nondetergent oil. The intermediate bronze bearings are impregnated with oil, so the oil reservoir is only to replace oil the bearing loses in operation. d. If intermediate grease lubricated bearings are used, the mounting plate connection will be a grease fitting. A grease similar to Mobilux EP No. 2 should be used. 5. Check rotation. Turn on water to lower bearing, jog motor, and note rotation. It should be clockwise when looking down on the pump. If rotation is incorrect, change any two leads on a three phase motor to correct. 6. If liquid level controls are used, set the proper levels. The pump should not start until the liquid level is at least above the lower bearing. The low level shutoff may be at any lower bearing is properly lubricated regardless of the sump liquid level. Maintenance Motor The motor manufacturer s recommendations should be followed. Some motors have packed and sealed bearings, so there is no need, or provision for, regular external lubrication. If there is a grease fitting on the motor end bell, lubrication should be provided as recommended by the manufacturer.

Coupling A non-lubricated coupling is the ESSCO standard, so no lubrication maintenance is required. The coupling should be inspected every six months for wear and parts replaced as necessary. Pump Inspect oil level reservoir or automatic grease lubricator(s) (if installed) weekly. The reservoir is used to replenish oil in the intermediate bearing. Oil use should be low. If the reservoir empties in one week, this may indicate a faulty bearing and it should be inspected. All connections should be checked for possible leaks. If a water solenoid valve is used, inspect to be certain the water flow is on before and during operation. If a bronze lower and/or intermediate bearings are used, 1 oz. of grease should be injected every four hours and before each starting if shut down more than four hours. Operational Problem Checkpoints NO LIQUID DELIVERED 2. Discharge head too high. 3. Suction or discharge line 4. Wrong direction of rotation. 5. Discharge valve closed. NOT ENOUGH LIQUID DELIVERED 2. Suction or discharge line partially 3. Total discharge head too high. 4. Damaged impeller or casing. NOT ENOUGH PRESSURE 2. Air or gas in liquid. 3. Leaks in suction. 4. Impeller diameter too small. 5. Damaged impeller or casing. MOTOR RUNS HOT 1. Speed too high. 2. Head lower than rating, allowing

pump to handle too much liquid. 3. Liquid heavier and more viscous than rating. 4. Impeller binding or rubbing. 5. Voltage and frequency lower than rating. 6. Defects in motor. ciently submerged. 4. Misalignment of coupling and shaft. 5. Worn or loose bearings. 6. Shaft bent. 7. Foundation not rigid. BEARINGS WEAR RAPIDLY 1. Misalignment. 2. Bent shaft. 3. Vibration. 4. Lack of lubrication. 5. Bearing improperly installed. 6. Moisture in oil. 7. Dirt in bearing. PUMP WORKS FOR AWHILE, THEN LOSES SUCTION 1. Leaky suction line tail pipe. 2. Suction or discharge line partially 3. Air or gas in liquid. 4. Air leaks in suction. 5. End of suction line uncovered. VIBRATION 1. Impeller Plugged on Non Clog Pumps. 2. Gas or vapor in the liquid. 3. Inlet to suction line not suffi-