INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

Similar documents
INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

SPECTRA S6000 TOUCH BAR EXIT DEVICES Discount Code XK

SPECTRA S6000 Touch Bar Exit Devices - RIM and SURFACE VERTICAL

S6000 Spectra Exit Devices

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

Pre-Installation Instructions

ADDENDUM MODEL S3 OPERATORS Models: SL/540/570/580/590 & SW420/470/490

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. FCC ID NOTICE

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

FM SECURITY AND REMOTE START SYSTEM

12V PROGRAMMABLE POWER OUT

DLKEK3HN INSTALLATION INSTRUCTIONS

Motorized Electric Latch Retraction

INSTALLATION INSTRUCTIONS & MANUAL BOOK FOR ARCHITECTS, GENERAL CONTRACTORS & DEALERS REV-2

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

SECURITY DOOR CONTROLS

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Security Door Controls

HANDLING MECHANICAL INSTALLATION

Electrical Options Booklet. Table of Contents

Model PRO 9246CH Installation Manual

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

Model APS-101N Installation Manual

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

Power Supplies DORMA PS

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL. Model: PLUS Vehicle Security

Security and Keyless Entry Installation Guide ca 1051

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Installation Instructions

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

115 VAC Control Boxes for

Electrified Products ELECTRIFIED PRODUCTS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

CS-2004 WDC. Remote Control Alarm System with CoolGlow & SecurWatch INSTALLATION & OPERATING INSTRUCTIONS

install guide OEM-CH(RS)-CH5-[FLRSCH5]-EN

AK-105B. ADVANCED KEYS Smart Keyless Entry + Push Start Ignition System USER MANUAL. Product Features:

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

Senior Swing Control Box. Table of Contents

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Installation Instructions & Users Manual

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

install guide DIR-CH(RS)-CH5-[AKX-CH5]-EN

115 VAC Control Boxes for

WARNING TABLE 3-1: DAILY SAFETY CHECK

Advanced Remote Vehicle Starting System

EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

VS 655 DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 655 1

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Remote Start with Keyless Entry Installation Guide ca5054

U S A INSTALLATION GUIDE EP400 / E8-B

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

Installation/Owner s Manual Series 6500

CM4200 and CM1000S Starter Control Module Installation Manual

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

GLM SERIES CONTROL Users Manual Rev:

Installation Instructions

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

SAVE THESE INSTRUCTIONS

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

9700/F9700 SERIES RIM EXIT DEVICE

Accessories 286 SDC SECURITY DOOR CONTROLS

Aftermarket Interface Module

Installation/Owner s Manual Series 6500

CLIFFORD CONCEPT 300 Wiring Instructions Re-compiled and illustrated by Ray Heffer (

FS-22 and FS-32 KEYLESS ENTRY and ALARM SYSTEM INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH

APOLLO Gate Operators, Inc.

CS-2900DP-FM Infinity DP SERIES II (DATA PORT) 2-Way FM Paging Alarm & Remote Engine Starting System OPERATION INSTRUCTIONS

Chexit/RCM/DE5300. Chexit/RCM/DE5300 Service Parts. Chexit Field Wiring Cable. DE5300/RCM Field Wiring Cable. Table of Contents

Programmable Output Module Installation Manual

115 VAC Control Boxes for

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

MM1 Installation Instructions

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

INSTALLATION 8310/8320

Transcription:

INSTALLATI INSTRUCTIS DEGR7700 DELAYED EGRESS ALL IN E DEVICE Stop Employee Theft Stop Retail Shoplifting Restrict Airport Patrons Restrict Wandering Patients SOUNDS. DOOR CAN BE The sign provides comprehensive and clear instructions of the door operation for persons without prior knowledge of the exit delay, including the sight and hearing impaired. Application: When unauthorized egress is initiated by depressing the push pad of the DEGR7700, an alarm will sound and an irreversible unlock delay period of 15 (optional 30) seconds will begin. Meanwhile, the person exiting must wait to egress giving personnel or security time to respond. After the delay period has expired, the device unlocks permitting egress until the device is reset. In an emergency, device will unlock immediately upon loss of power or when powered by a fire control supervised power supply. The included signage provides clear and comprehensive instructions of door operation allowing egress for all without prior knowledge of operation. Features: Egress Delay 15 second exit delay 1 or second nuisance delay Control Inputs 1 to 30 second request-to-exit and bypass input with anti-tailgate and door prop alarm. Bypass Reset Remote Trigger DPS (for Door Prop and Anti-Tailgate) Built-In Annunciation Armed mode Nuisance mode Irreversible egress mode Release mode Monitoring Outputs Armed mode Egress initiation status Released status Trigger Modes Egress alarm triggered by Push Bar Trigger input from external device Door opened in secure mode (Door Prop) Code Compliance IFC International fire Code IBC International Building Code NFPA 101 Life Safety Code NFPA 1 Uniform Fire Code California Building Code Field selectable automatic or manual power up after emergency release or power loss. Use of manual power up complies with California Building Code (OSHPD) requirements. SECURITY LISTED FWAX SPECIAL LOCKING ARRANGEMENTS 4UT9 P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page 1

AC Mains 3 RIM DEVICE FACP SURFACE VERTICAL ROD DEVICE AC Mains 3 FACP 60RF Supply 631RF Supply J-Box to 10 to 10 Conductors DPS (Optional) 4 to 10 DPS (Optional) DPS (Optional) 4 Conductors SOU NDS. DOOR CAN BE SOU NDS. DOOR CAN BE SOU NDS. DOOR CAN BE Transfer Device or Hinge Transfer Device or Hinge Transfer Device or Hinge Single Door Pair of Doors Board Layout (LR Device shown) J4 TO KEY SWITCH RESET J6 J7 PIGTAIL CNECTI DIP SWITCHES 1 3 4 Siren STATUS LED J5 TO KEY SWITCH BYPASS MITOR RELAY JUMPER SETTINGS* DIP SWITCH SETTINGS *Individually sets the polarity of the & RED relays when the relay is in an ACTIVE state. [OFF] [] WARNING! CTACT THE AUTHORITY HAVING JURISDICTI FOR APPROVAL PRIOR TO SELECTING NUSIANCE TIME OR PWR-UP SETTINGS Left Pins = N/O Right Pins = N/C J6 = RELAY (Active when device is secure) J7 = RED RELAY (Active upon alarm initiation) 1 3 4 PWR UP STATE NUISANCE DELAY REX PERIOD UNLOCKED LOCKED 1s s 15s 0s 30s 1s P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page

Device Wiring Pigtail ORG = Slave Out 1 VIO = Remote Trigger 1 BRN = Red Relay 1 = Green Relay 1 YEL = Relay Common 1 (4vdc @ 50ma) (For pairs of doors) Electrical Specifications: Input Voltage : 4VDC +/- 10% Input Current : 540ma Max Monitor Relays: 1 Amp contacts @1/4vdc Slave Output : 4VDC @50ma GRY = DPS 1,3 BLU = Reset / REX 1 = Bypass 1 RED = In (+) BLK = In (-) (4VDC) 1 THESE WIRES SHALL BE CNECTED TO AN ACCESSORY IN THE PROTECTED AREA. UNUSED WIRES SHOULD BE CAPPED OFF. THIS PRODUCT MUST BE POWERED BY 600 SERIES POWER SUPPLY: Single Door 60RF 1 AMP Double Door 631RF 1.5 AMP 3 A DOOR CTACT IS REQUIRED FOR ANTI-TAILGATE AND DOOR PROP FUNCTIS. Enviromental: Max Operating Temperature: 0 C to 70 C Tested to 85% RH @30 C Wire Color Orange Violet Wire Designation Slave Out Remote Trigger Description Used for a pair of doors (master & slave). This is a voltage output (4VDC @50mA). Connect this wire to +4VDC (Red wire) of the slave bar. See "Typical Wiring for Single or Double Door Installation". Used for a pair of doors (master & slave). This is a dry input. Connect this wire to one leg of the Slave Trigger output. The other leg of the Slave Trigger output is connected to ground (-VDC). Closing the switch shorts this wire to ground and initiates the alarm sequence. See "Typical Wiring for Single or Double Door Installation". The two white wires on the slave bar are the Normally Open trigger switch. Brown Red Relay This is the Alarm Relay Output (Dry, 1A@1/4VDC). It is normally INACTIVE when the door is secure. It changes state when the bar is pressed beyond the nuisance delay and placed into an Alarm state. It may be configured as Normally Open OR Normally Closed using Jumper J7. The YELLOW wire is the relay common. Green Green Relay This is the Door Secure Relay Output (Dry, 1A@1/4VDC). It is normally ACTIVE when the door is secure. It changes state when the bar unlocks after (a) the delayed egress countdown expires, (b) an authorized Request-to-Exit(REX) signal, or (c) the bar is Bypassed. It may be configured as Normally Open OR Normally Closed using Jumper J6. The YELLOW wire is the relay common. Yellow Relay Common This is the shared relay common for both the Red & Green Relay. Grey Blue Door Position Switch (DPS) Reset/REX This is a dry input. Connect this wire to one leg of a Door Contact switch. The other leg of the Door Contact switch is connected to ground (-VDC). The Door Contact polarity must be OPEN when the door is closed. A door contact is required for antitailgate and door prop alarm functions. This is a momentary, dry input. Connect this wire to one leg of a Normally Open switch. The other leg of the Normally Open switch is connected to ground (-VDC). When the bar is in a secure state, shorting this input will result in an authorized unlock (REX). The REX period is configured by the dip switch settings. When the bar is in an alarm, authorized unlock state, or in a bypassed state, shorting this input will reset (secure) the bar. White Bypass This is a momentary, dry input. Connect this wire to one leg of a Normally Open switch. The other leg of the Normally Open switch is connected to ground (-VDC). When the bar is in a secure state, shorting this input will unlock the device indefinitely, until the bar is Reset. Red IN (+) 4VDC Input Voltage: 4VDC +/- 10%; Input Current: 540mA (max). The Red & Black wires Black IN (-) 4VDC are the minimum required connections for a single door application. P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page 3

TYPICAL WIRING FOR SINGLE OR DOUBLE DOOR INSTALLATI MASTER 1 3 4 Transfer NOTE: Red & Blk pigtail wires are the minimun required connections for a single door application. 631RF POWER SUPPLY **Door Contact (Master) GRY (DPS) BLK (-) RED (+) YEL (Rly COM) 4VDC **Door Contact connection is optional, but required for anti-tailgate and door prop alarms. (Bypass) BLU (Reset/Rex) BRN N/O N/C C Installation Note: Cap any unused leads. ACCESS CTROL SYSTEM **Door Contact (Slave) ORG (+4VDC Out) VIO (Remote Trig) SLAVE PIGTAIL BLK RED Transfer KEY CYLINDER INSTALLATI & OPERATI INSTALL CYLINDER LOCK (NOT SUPPLIED) INTO DEVICE COVER AS SHOWN PAGE 6. Key cylinder is in the normal, center position. LED is solid green when the device is secure. To bypass the device for an extended period of time, momentarily turn the key cylinder towards Bypass and return to the center position. LED will flash slowly. When the device is in a secure state, momentarily turning the key cylinder towards Reset will result in a timed authorized unlock (REX). When the device is in an alarm, authorized unlock, or bypassed state, momentarily turning the key cylinder towards Reset will re-secure the device. P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page 4

TYPICAL WIRING FOR SINGLE DOOR WITH ELECTRIC TRIM J6 = RELAY (Active when device is secure) Left Pins = Set for Fail-Secure Electric Trim Right Pins = Set for Fail-Safe Electric Trim SDC 600 Series REGULATED & FILTERED POWERSUPPLY MASTER 1 3 4 **Door Contact **Door Contact connection is optional, but required for anti-tailgate and door prop alarms. GRY (DPS) ORG VIO BRN Transfer BLK (-) RED (+) YEL (Rly COM) (Bypass) BLU (Reset/REX) Installation Note: Cap any unused leads. (-) 4VDC + N/O N/C C ACCESS CTROL SYSTEM ELECTRIC TRIM (+) (-) MOV* *Install MOV across coil to protect device electronics. STATUS LED INDICATIS Status OFF GREEN (Solid) YELLOW RED (Solid) GREEN (Slow Flash) GREEN (Fast Flash) RED (Fast Flash) Device Mode No Secure Irreversible Delay in Progress Alarmed & Unlocked Bypassed Authorized Unlock (REX) Alarmed, Unlocked, & Door Opened P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page 5

Use the supplied Clover Tailpiece or equivalent. (863J) ILCO equivalent tail pieces: 863D 863S 1 Install Key Cylinder as shown and secure with locking nut provided. Remove and position Tailpiece as shown. 3 Insert Key and check for proper operation. P:\INSTALLATI INST\Delayed Egress\INST-DEGR7700.vsd Rev -. 10-16 Page 6