INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER

Similar documents
CHTO-02 Chrysler/Dodge Amplified Data Interface

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

Chevy Equinox / GMC Terrain 2013-up (with color display) G

Security and Keyless Entry Installation Guide ca 1051

Harley-Davidson Street Glide, Electra Glide, Ultra and Limited models 2014-up

Chevrolet Camaro 2010-up S-LC

GMOS-LAN-034 GM LAN-11 OnStar interface

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

2 Way Security and Keyless Entry Installation Guide ca 1553

INSTALLATION INSTRUCTIONS FOR PART INSTGMOS-LAN-03. GMOS-LAN-03 GM LAN 11 Non-amplified OnStar APPLICATIONS. See inside front cover KIT FEATURES

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

GM ONSTAR LAN DATA BUS INTERFACE GMOS-LAN-02 INSTALLATION INSTRUCTIONS

GMOS-LAN-02 GM LAN 29 Amplified OnStar Interface 2006-up

INSTALLATION GUIDE. FCC ID NOTICE

MEGA WAY LCD REMOTE ENGINE STARTER AND CAR ALARM SECURITY. Installation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 2700 INSTALL 1

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

"WE'VE GOT THE EDGE ON SECURITY" INSTALLATION MANUAL AL-700 ATV / AL-900 ATV / AL-1000 ATV

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

CH. Ford Mustang

FEB.20, 2003 COMMANDO MODEL FM-870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST872 1

B. Ford Fusion 2013-up

Advanced Instructions

VS 655 DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 655 1

Retains OnStar/OE Bluetooth Adjustable volume for chimes and OnStar Retains satellite radio Retains balance and fade Micro B USB updatable

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

jegs.com

Nissan Maxima (with Technology Package) Nissan Maxima (with NAV) 2009 KIT FEATURES. ISO DIN radio provision with pocket...

Shaved-B. Installation Manual & Operation Instructions

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Nissan Pathfinder (without NAV) (with color screen) HG

Remote Start with Keyless Entry Installation Guide ca5054

Vehicle Security System

B. Ford Fusion 2013-up* *Visit metraonline.com for up-to-date vehicle specific applications.

Chevy Sonic 2012-up G

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

AX-GMLAN44-SWC. GM Data Interface with SWC

VS CHANNEL REMOTE ENGINE STARTER WITH KEYLESS ENTRY. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

AX-MAZ1-SWC. Mazda Data Interface with SWC

INTERFACE PART NUMBER NOTES

MM1 Installation Instructions

CH. Ford Edge (with 4.2 screen)

IN VEHICLE SECURITY ULTIMATE FLEXIBILITY. Installation Supplement. ClassicOne & UltraOne

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst

GM ONSTAR LAN DATA BUS INTERFACE GMOS-LAN-01. Installation Instructions

Vehicle Security System

Jeep Cherokee Latitude/Limited 2014-up

Vehicle Security System

INSTRUCTIONS. 20 Circuit Wiring Kit Instructions October 2009, Speedway Motors, Inc.

Model APS-101N Installation Manual

DLKEK3HN INSTALLATION INSTRUCTIONS

CH. Ford Explorer (with 4.2 screen)

INSTALLATION MANUAL 601-S INFORMATION.) 8. REMOVE DOME LIGHT FUSE TO PRE- VENT BATTERY DRAIN.

FM SECURITY AND REMOTE START SYSTEM

AX-CH5-SWC. Chrysler Data Interface with SWC 2013-up* *Visit AxxessInterfaces.com for up-to-date vehicle specific applications.

GPS-D4550. Installation And Testing Guide VEHICLE TRACKING & RECOVERY SYSTEM. Model: Quick Reference Install Guide

DirectWire Vehicle Information 2016 Kia Soul - North America. Page 1 of 5. Wiring Information. Page 1 of 5

PROFESSIONAL REMOTE ALARM SYSTEM INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR PART OESWC-LAN29-RF OESWC-LAN29-RF

SHAVE DOOR HANDLE SYSTEMS

GMOS-11 Installation Instructions

INSTALLATION INSTRUCTIONS FOR PART FRST FRST. *Read Important Warning On Page 1 Before Attempting Any Installation*

AFSI-02 SYNC INTERFACE INSTALLATION INSTRUCTIONS FORD SYNC INTERFACE * READ IMPORTANT WARNING ON PAGE 1 BEFORE ATTEMPTING ANY INSTALLATION

GMOS-LAN-012. GM LAN-29 Data Interface 2006-up* *Visit AxxessInterfaces.com for up-to-date vehicle specific applications.

CSI-300 Installation Instructions

B. Ford Focus (with 4.2 screen) 2015-up* *Visit MetraOnline.com for up-to-date vehicle specific applications.

AFSI-01 SYNC INTERFACE INSTALLATION INSTRUCTIONS FORD SYNC INTERFACE * READ IMPORTANT WARNING ON PAGE 1 BEFORE ATTEMPTING ANY INSTALLATION

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Remote Keyless Entry Installation Guide ca 2051

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

Model K20 installation guide. ProSecurity

RS-351-EDP. Installation Guide

Security and Remote Start Installation Guide for models: ca6553 ca6553sst

INSTALLATION MANUAL MODEL: K9-FIVE ATV L I M I T E D L I F E T I M E W A R R A N T Y

INSTALLATION INSTRUCTIONS FOR PART OESWC-6502-RF

Ram 1500/2500/ up (with 8 touchscreen) B

REC-11+ REMOTE RECEIVER UNIT

AX-HYKIA2-SWC. Hyundai Data Interface with SWC

GMOS-05 Installation Instructions

Model APS-510C Installation Manual Remote Control Vehicle Security System

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

PIM701 (Police Interface Module) Dodge Charger Pursuit

TOOLS REQUIRED Wire cutter Crimp tool Solder gun Tape Connectors (example: butt-connectors, bell caps, etc.) Small flat-blade screwdriver

RS-340-EDP+ / RS-450-EDP+

Installation Instructions

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152

Ford Flex (without NAV) TABLE OF CONTENTS Dash Disassembly Kit Preparation...4 Kit Assembly KIT FEATURES

AX-ADGM01. GM Data Interface 2006-up* *Visit AxxessInterfaces.com for up-to-date vehicle specific applications.

VS CHANNEL REMOTE ENGINE STARTER WITH KEYLESS ENTRY. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

AXi-GMBOX1 INSTALLATION MANUAL

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

Manual - Inside Front Cover (Blank)

Ford F up CH

Remote Start with Keyless Entry Installation Guide CA 5051

GM ONSTAR CLASS II DATA BUS INTERFACE GMOS-04. Installation Instructions SEE APPLICATIONS LIST INSIDE TOOLS REQUIRED FOR INSTALLATION

Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST

Transcription:

6 2.5 1.5 ISO M4 M5 M3 WIRE CUTTER INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER The Trigger is a universal module that provides 15 different preset functions that are activated from a positive or negative trigger. In addition to the preset features, the Trigger has 8 custom modes with customizable settings that allows the installer to utilize their imagination. TOOLS REQUIRED FOR INSTALLATION Cutting ol Tape Crimping ol Connectors (ie. butt connectors, bell caps, etc.) M3.5 M2.6 IGNITION TERMINALS

Pin diagram Pin 1: Black (Chassis ) Pin 2: Purple (Configuration input) Pin 3: White (Configuration input) Pin 4: Pink (Configuration input) Pin 5: Orange (Configuration input) TRIGGER Pin 6: Green ((-) Output 500mA Max) Pin 7: Red ((-) Output 500mA Max) Pin 8: Blue ((+) output 2 amp Max) Pin 9: Brown (+ 0.8-16v input trigger) Pin 10: Gray (- input trigger) Pin 11: Yellow (12 volt Constant/Switched) Notes: *Pin 1 needs to be attached to ground and pin 11 needs to be attached to 12 volt constant on all configurations listed below. * Metra recommends using a single pulse double throw relay in every application. (Metra part # E-123)

Descriptions of modes and wiring instructions. Default: EBrake Emulator Description: Emulates an EBrake signal for use in RV s, off road vehicles, and exhibition vehicles. Aftermarket radios parking brake input Aftermarket radios parking brake intput Foot brake of radio Vehicles accessory or ignition Mode 1: Retained accessory power Description: Device will turn on when accessory turns on, and will not turn off until door opens or 10 minutes passes, whichever comes first. Retained accessory output (2 amp max) Vehicles accessory or ignition Negative door trigger

Mode 2: Delayed turn-on Description: When the input is activated, there will be a 2-second delay before pin 8 turn-on. Negative delay turn-on output (500 ma max) Negative delay turn-on output (500mA max) Positive delay turn-on output (2 amp max) 12 volt output Mode 3: Low voltage turn-on Description: Provides 12 volts turn on from a low voltage source 12 volt output (2 amp max) Low voltage input

Mode 4: Latched outputs Description: Allow the capability of making a pulsed signal a latched signal. Negative latched output (500 ma max) Negative latched output (500 ma max) Positive latched output (2 amp max) Positive pulsed input (use only one) Negative pulsed input (use only one)

Mode 5: GMLAN aftermarket amp turn-on Description: Provides an amp turn on LAN vehicles for adding an aftermarket amp. Aftermarket amplifiers turn on.(2 amp max) Remote turn on from vehicle (see attached diagram) Vehicle mute (see attached diagram) Connector 1 Connector 2 7 8 1 1 8 14 16 9 Vehicle Vehicle Connect connector PIN to number number Trigger 1 1 Pin 11 (Yellow) 1 8 Pin 1 (Black) 1 6 2 8

Mode 6: Active edge pulse generator Description: Allow the capability of making an input signal a pulse signal. Negative pulsed output (500 ma max) Negative pulsed output (500 ma max) Positive pulsed output (2 amp max) Positive input (use only one) Negative input (use only one) Mode 7: Turn-off delay Description: When the output is turned off, the pin 8 will stay active for two additional seconds. Negative delay turn-off output (500 ma max) Negative delay turn-off output (500mA max) Positive delay turn-off output (2 amp max) 12 volt output

Mode 8: Double pulse latch Description: Creates a latched signal from a double pulse signal. Negative latched output (500 ma max) Negative latched output (500 ma max) Positive latched output (2 amp max) Positive double pulse input (use only one) Negative double pulse input (use only one) Mode 9: Double pulse to one-second output Description: Converts a double pulse output to a single pulse output Negative single pulse output (500 ma max) Negative single pulse output (500 ma max) Positive single pulse output (2 amp max) Positive double pulse input (use only one) Negative double pulse input (use only one)

Mode 10: Theft detection/closed loop trigger Description: When connected, if item loses ground the Trigger will send out a 12 volt constant signal which can be hooked to an audible device. Pin 10 (Brown) Positive of siren (not included)(2 amp max) Items ground point. Mode 11: Channel expander Description: Gives the ability to add additional channels to an alarm, etc Negative latched output (500 ma max) (2 pulses to activate) Negative latched output (500 ma max) (1 pulse to activate) Positive latched output (2 amp max) (3 pulses to activate) Positive pulse input (use only one) Negative pulse input (use only one)

Mode 12: Simple data detector (amp turn on signal from data) Description: Produces a positive or negative signal out when data is detected. Note: Output will stay on 3 seconds after data stops transmitting. Negative output (500 ma max) Negative output (500 ma max) Positive output (2 amp max) Vehicles data line (see attached diagrams) Mode 13: Long delayed turn-off (for headlights) Description: This mode will keep headlights on for 1 minute after ignition is turned off. Negative 1 minute output (500 ma max) Negative 1 minute output (500 ma max) Positive 1 minute output (2 amp max) Headlight switch (negative signal)

Mode 14: Dome light delay Description: Keeps dome light on for 30 seconds after ignition is turned off Negative 30 second output (500 ma max) Negative 30 second output (500 ma max) Positive 30 second output (2 amp max) Accessory or ignition from vehicle

Mode 15: Custom program Description: Ability to custom program the Trigger using the Trigger program. Custom Program Modes: Custom Mode 1: Channel expander, latched Description: Measures pulses that occur during 5 second interval. One pulse per 5 seconds will toggle PIN 6 (GREEN), two pulses per 5 seconds will toggle PIN 7 (RED), and three pulses per 5 seconds will toggle PIN 8 (BLUE). Negative latched output (500 ma max) (2 pulses to activate) Negative latched output (500 ma max) (1 pulse to activate) Positive latched output (2 amp max) (3 pulses to activate) Positive pulse input (use only one) Negative pulse input (use only one)

Custom Mode 2: Channel expander, pulsed Description: Measures pulses that occur during 5 second interval. One pulse per 5 seconds will drive PIN 6 (GREEN) active for XX seconds, two pulses per 5 seconds will drive PIN 7 (RED) active for XX seconds, and three pulses per 5 seconds will drive PIN 8 (BLUE) active for XX seconds. XX is definable between.1 and 300 seconds. Negative pulsed output (500 ma max) (2 pulses to activate) Negative pulsed output (500 ma max) (1 pulse to activate) Positive pulsed output (2 amp max) (3 pulses to activate) Positive pulse input (use only one) Negative pulse input (use only one)

Custom Mode 3: Delayed turn-off Connect active high input to pin 9, or active low input to pin 10. Use any output pin. When input goes high, output will turn on immediately. When input goes inactive, output turn-off will be delayed by XX seconds, where XX is definable between.1 and 300 seconds. Negative latched output (500 ma max) Negative latched output (500 ma max) Positive latched output (2 amp max) Positive pulse input (use only one) Negative pulse input (use only one)

Custom Mode 4: Delayed turn-on Description: Connect active high input to pin 9, or active low input to pin 10. Use any output pin. When input goes high, output will turn on after a delay of XX seconds. When input goes inactive, output turn-off will be immediate. XX is definable between.1 and 300 seconds. Negative latched output (500 ma max) Negative latched output (500 ma max) Positive latched output (2 amp max) Positive input (use only one)

Custom Mode 5: Generic three-output delay/pulse width, edge driven (for use with linear actuators) Description: When either input goes active, each output will go active after a delay, and then stay active for a pulse width. Each output has an independent delay and pulse width, definable between.1 and 300 seconds. Negative output (500 ma max) Negative output (500 ma max) Positive output (2 amp max) Positive pulse input (use only one) Negative pulse input (use only one)

Custom Mode 6: Generic three-output delay/pulse width, level driven (validity) Description: When either input goes active, each output will go active after a delay, and then stay active for a pulse width. Each output has an independent delay and pulse width, definable between.1 and 300 seconds. Negative output (500 ma max) Negative output (500 ma max) Positive output (2 amp max) Positive pulse input (use only one) Negative pulse input (use only one)

Custom Mode 7: Square wave-generator (sounds horns and blinks lights) Description: When either input goes active, all three outputs will toggle every XX seconds, where XX is definable between.1 and 300 seconds. Stops when input goes inactive. Negative output (500 ma max) Negative output (500 ma max) Positive output (2 amp max) Positive latched input (use only one) Negative latched input (use only one)

Custom Mode 8: Multiple pulse generator Description: A single input pulse on either input will produce multiple pulses on all outputs. The number of pulses can vary from 1 to 255, and each pulse will last XX seconds, where XX is definable between.1 and 300 seconds. Multiple Negative pulsed output (500 ma max) (2 pulses to activate) Multiple Negative pulsed output (500 ma max) (1 pulse to activate) Multiple Positive pulsed output (2 amp max) (3 pulses to activate) Positive pulse input (use only one) Negative pulse input (use only one) AXXESS ACCESSORIES STEREOS