Enhancement of Grid Power By Using Pv Or Wind Statcom In Transmission Lines

Similar documents
Control Application of PV Solar Farm as PV- STATCOM for Reactive Power Compensation during Day and Night in a Transmission Network

FUZZY BASED CONTROL OF PV SOLAR FARM AS PV- STATCOM FOR REACTIVE POWER COMPENSATION DURING DAY AND NIGHT

International Journal of Scientific & Engineering Research, Volume 7, Issue 4, April ISSN

Utilization of PV Solar Farm as a STATCOM in a Distribution Networking

Lab Validation of PV Solar Inverter Control as STATCOM (PV-STATCOM) Rajiv K. Varma and Ehsan Siavashi

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

Application of Photovoltaic (PV) Solar Farm In STATCOM to Regulate the Grid Voltage

Novel Control of PV Solar and Wind Farm Inverters as STATCOM for Increasing Connectivity of Distributed Generators

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Implementation of FC-TCR for Reactive Power Control

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

Benefits of HVDC and FACTS Devices Applied in Power Systems

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Design and Implementation of an 11-Level Inverter with FACTS Capability for Distributed Energy Systems

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Simulation Analysis of Closed Loop Dual Inductor Current-Fed Push-Pull Converter by using Soft Switching

Analysis of Grid Connected Solar Farm in ETAP Software

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

ELG4125: Flexible AC Transmission Systems (FACTS)

Statcom Operation for Wind Power Generator with Improved Transient Stability

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Tiruchengode, Tamil Nadu, India

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System

INTERNATIONAL JOURNAL OF PROFESSIONAL ENGINEERING STUDIES Volume 10 /Issue 1 / JUN 2018

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

Wind-Turbine Asynchronous Generator Synchronous Condenser with Excitation in Isolated Network

Integration of Large Wind Farms into Electric Grids

A SIMPLE CONTROL TECHNIQUE FOR UNIFIED POWER FLOW CONTROLLER (UPFC)

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Implementation of Bidirectional DC-DC converter for Power Management in Hybrid Energy Sources

A Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS

Design and Simulation of Grid Connected PV System

A Review on Reactive Power Compensation Technologies

Low-Frequency AC Transmission for Offshore Wind Power

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

International Journal of Advance Research in Engineering, Science & Technology

Load Frequency Control of a Two Area Power System with Electric Vehicle and PI Controller

Dynamic Control of Grid Assets

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

Overview of Flexible AC Transmission Systems

POWER QUALITY IMPROVEMENT IN GRID CONNECTED WINDENERGY SYSTEM USING STATCOM S. Rajesh Rajan

GRID CONNECTED SOLAR WIND HYBRID POWER BASED ON IOT

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators,

Reactive Power Compensation at Load Side Using Electric Spring

SOLAR PHOTOVOLTAIC ARRAY FED WATER PUMP RIVEN BY BRUSHLESS DC MOTOR USING KY CONVERTER

Design and Control of Hybrid Power System for Stand-Alone Applications

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

Modeling and Simulation of Firing Circuit using Cosine Control System

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Experimental Resultsofa Wind Energy Conversion Systemwith STATCOM Using Fuzzy Logic Controller

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Dynamic Control of Grid Assets

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

Power Flow Control through Transmission Line with UPFC to Mitigate Contingency

[Patil, 7(2) April-June 2017] ISSN: Impact Factor: 4.015

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Behaviour of battery energy storage system with PV

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

EPE 18 ECCE Europe: LIST OF KEYWORDS

Maintaining Voltage Stability in Power System using FACTS Devices

Modeling and Simulation of Solar PV Wind Hybrid System for Induction Motor Drive Application T. SRIPAL REDDY 1, B. ANURADHA 2

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Inverter with MPPT and Suppressed Leakage Current

Design and Modelling of Induction Generator Wind power Systems by using MATLAB/SIMULINK

The hierarchical three layer protection of photovoltaic generators in microgrid with co-ordinated droop control for hybrid energy storage system

Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

Increasing the Power Quality for Grid Connected Wind Energy System Using Facts

Modeling Comparision Of Solar Pv/ Fuelcell/Ultra Capacitor Hyrbrid System For Standalone And Grid Connected Application

Induction Generator: Excitation & Voltage Regulation

Speed Control of 3-Phase Squirrel Cage Induction Motor by 3-Phase AC Voltage Controller Using SPWM Technique

POWER ELECTRONICS & DRIVES

EMS of Electric Vehicles using LQG Optimal Control

A Single-Phase D-Statcom Five Level Inverter for Wind Applications

Improving Power System Transient Stability by using Facts Devices

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

Reactive Power Management Using TSC-TCR

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

Wind Farm Evaluation and Control

Transcription:

Enhancement of Grid Power By Using Pv Or Wind Statcom In Transmission Lines G.Raviteja 1 Dr.Samalla Krishna 2 Mr.S.Srikanth 3 1 M. Tech Student Deptt of of Electrical & Electronics Engg. Tudi Ram Reddy Institute of Technology&Sciences, Hydearabad. ravitheja.gujja@gmail.com 2 Professors, & Principal. Tudi Ram Reddy Institute of Technology&Sciences, Hydearabad. Krishna.oume@gmail.com 3 Assistant Professor, Department of Electrical & Electronics Engg. Tudi Ram Reddy Institute of Technology & Sciences, Hydearabad. Ssrikanth674@gmail.com ABSTRACT The main aim of project is a novel concept of utilizing a photovoltaic (PV) solar farm inverter as STATCOM, called PV-STATCOM, for improving stable power transfer limits of the interconnected transmission system. The entire inverter rating of the PV solar farm, which remains dormant during nighttime, is utilized with voltage and damping controls to enhance stable power transmission limits. During daytime, the inverter capacity left after real power production is used to accomplish the aforementioned objective. Transient stability studies are conducted on a realistic single machine infinite bus power system having a midpoint located PV-STATCOM using simulation software. Power transfer increases are also demonstrated in the same power system for: 1) two solar farms operating as PV- STATCOMs and 2) a solar farm as PV- STATCOM and an inverter-based wind farm with similar STATCOM controls. This novel utilization of a PV solar farm asset can thus improve power transmission limits which would have otherwise required expensive additional equipment, such as series/shunt capacitors or separate flexible ac transmission system controllers. Index terms: PV-STATCOM, Solar farm, Power quality, Wind system, 1.INTRODUCTION This paper proposes novel voltage control, together with auxiliary damping control, for a grid-connected PV solar farm inverter to act as a STATCOM both during night and day for increasing transient stability and consequently the power transmission limit. This technology of utilizing a PV solar farm as a STATCOM is called PV-STATCOM. It utilizes the entire solar farm inverter capacity in the night and the remainder inverter capacity after real power generation during the day, both of which remain unused in conventional solar farm operation. Similar STATCOM control functionality can also be implemented in inverter-based wind turbine generators during no-wind or partial wind scenarios for improving the transient stability of the system. Studies are performed for two variants of a single-machine infinite bus (SMIB) system. One SMIB system uses only a single PV solar farm as PV- STATCOM connected at the midpoint whereas the other system uses a combination of a PV- Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1241

STATCOM and another PV-STATCOM or an inverter-based wind distributed generator (DG) with similar STATCOM functionality. Threephase fault studies are conducted using the electromagnetic transient software EMTDC/PSCAD, and the improvement in the stable power transmission limit is investigated for different combinations of STATCOM controllers on the solar and wind farm inverters, both during night and day. 2.PHOTOVOLTAIC TECHNOLOGY Photovoltaic s is the field of technology and research related to the devices which directly convert sunlight into electricity using semiconductors that exhibit the photovoltaic effect. Photovoltaic effect involves the creation of voltage in a material upon exposure to electromagnetic radiation. The photovoltaic effect was first noted by a French physicist, Edmund Becquerel, in 1839, who found that certain materials would produce small amounts of electric current when exposed to light. In 1905, Albert Einstein described the nature of light and the photoelectric effect on which photovoltaic technology is based, for which he later won a Nobel prize in physics. The first photovoltaic module was built by Bell Laboratories in 1954. It was billed as a solar battery and was mostly just a curiosity as it was too expensive to gain widespread use. In the 1960s, the space industry began to make the first serious use of the technology to provide power aboard spacecraft. Through the space programs, the technology advanced, its reliability was established, and the cost began to decline. During the energy crisis in the 1970s, photovoltaic technology gained recognition as a source of power for non-space applications. The solar cell is the elementary building block of the photovoltaic technology. Solar cells are made of semiconductor materials, such as silicon. One of the properties of semiconductors that makes them most useful is that their conductivity may easily be modified by introducing impurities into their crystal lattice. For instance, in the fabrication of a photovoltaic solar cell, silicon, which has four valence electrons, is treated to increase its conductivity. On one side of the cell, the impurities, which are phosphorus atoms with five valence electrons (n-donor), donate weakly bound valence electrons to the silicon material, creating excess negative charge carriers. On the other side, atoms of boron with three valence electrons (p-donor) create a greater affinity than silicon to attract electrons. Because the p-type silicon is in intimate contact with the n-type silicon a p-n junction is established and a diffusion of electrons occurs from the region of high electron concentration (the n-type side) into the region of low electron concentration (p-type side). When the electrons diffuse across the p-n junction, they recombine with holes on the p-type side. However, the diffusion of carriers does not occur indefinitely, because the imbalance of charge immediately on either sides of the junction originates an electric field. This electric field forms a diode that promotes current to flow in only one direction. Ohmic metal-semiconductor contacts are made to both the n-type and p-type sides of the solar cell, and the electrodes are ready to be connected to an external load. When photons of light fall on the cell, they transfer their energy to the charge carriers. The electric field across the junction separates photogenerated positive charge carriers (holes) from their negative counterpart (electrons). In this way an electrical current is extracted once the circuit is closed on an external load. Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1242

Fig 1: Solar cell. The photovoltaic effect was first reported by Edmund Becquerel in 1839 when he observed that the action of light on a silver coated platinum electrode immersed in electrolyte produced an electric current. Forty years later the first solid state photovoltaic devices were constructed by workers investigating the recently discovered photoconductivity of selenium. In 1876 William Adams and Richard Day found that a photocurrent could be produced in a sample of selenium when contacted by two heated platinum contacts. The photovoltaic action of the selenium differed from its photoconductive action in that a current was produced spontaneously by the action of light. No external power supply was needed. In this early photovoltaic device, a rectifying junction had been formed between the semiconductor and the metal contact. In 1894, Charles Fritts prepared what was probably the first large area solar cell by pressing a layer of selenium between gold and another metal. 3. STATCOM The STATCOM has a characteristic similar to the synchronous condenser, but as an electronic device it has no inertia and is superior to the synchronous condenser in several ways, such as better dynamics, a lower investment cost and lower operating and maintenance costs. A STATCOM is build with Thyristors with turnoff capability like GTO or today IGCT or with more and more IGBTs. The static line between the current limitations has a certain steepness determining the control characteristic for the voltage. The advantage of a STATCOM is that the reactive power provision is independent from the actual voltage on the connection point. This can be seen in the diagram for the maximum currents being independent of the voltage in comparison to the SVC. This means, that even during most severe contingencies, the STATCOM keeps its full capability. In the distributed energy sector the usage of Voltage Source Converters for grid interconnection is common practice today. The next step in STATCOM development is the combination with energy storages on the DCside. The performance for power quality and balanced network operation can be improved Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1243

much more with the combination of active and reactive power. STATCOMs are based on Voltage Sourced Converter (VSC) topology and utilize either Gate-Turn-off Thyristors (GTO) or Isolated Gate Bipolar Transistors (IGBT) devices. The STATCOM is a very fast acting, electronic equivalent of a synchronous condenser. If the STATCOM voltage, Vs, (which is proportional to the dc bus voltage Vc) is larger than bus voltage, Es, then leading or capacitive VARS are produced. If Vs is smaller then Es then lagging or inductive VARS are produced. Fig.2pulses statcom. The three phases STATCOM makes use of the fact that on a three phase, fundamental frequency, steady state basis, and the instantaneous power entering a purely reactive device must be zero. The reactive power in each phase is supplied by circulating the instantaneous real power between the phases. This is achieved by firing the GTO/diode switches in a manner that maintains the phase difference between the ac bus voltage ES and the STATCOM generated voltage VS. Ideally it is possible to construct a device based on circulating instantaneous power which has no energy storage device (ie no dc capacitor. 4. MODELLING OF PROPOSED SYSTEM The single-line diagrams of two study systems: Study System 1 and Study System 2 are depicted in Fig. Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1244

Fig3. Single-line diagram of (a) study system I with a single solar farm (DG) and (b) study system II with a solar farm (DG) and a solar/wind farm (DG). respectively. Both systems are single-machine infinite bus (SMIB) systems where a large equivalent synchronous generator (1110 MVA) supplies power to the infinite bus over a 200-km, 400-kV transmission line. This line length is typical of a long line carrying bulk power in Ontario. In Study System 1, a 100-MW PV solar farm (DG) as STATCOM (PV-STATCOM) is connected at the midpoint of the transmission line. In Study System 2, two 100-MVA inverter-based distributed generators (DGs) are connected at 1/3 (bus 5) and 2/3 (bus 6) of the line length from the synchronous generator. The DG connected at bus 6 is a PV-STATCOM and the other DG at bus 5 is either a PV-STATCOM or a wind farm with STATCOM functionality. In this case, the wind farm employs permanent-magnet synchronous generator (PMSG)-based wind turbine generators with a full ac-dc-ac converter. A maximum power point tracking (MPPT) algorithm based on an incremental conductance algorithm is used to operate the solar DGs at its maximum power point all of the time and is integrated with the inverter controller. The wind DG is also assumed to operate at its maximum power point, since this proposed control utilizes only the inverter capacity left after the maximum power point operation of the solar DG and wind DG. For PV-STATCOM operation during nighttime, the solar panels are disconnected from the inverter and a small amount of real power is drawn from the grid to charge the dc capacitor. The voltage-source inverter in each DG is composed of six insulated- gate bipolar transistors (IGBTs) and associated snubber circuits as shown in Fig. An appropriately large dc capacitor of size 200 Farad is selected to reduce the dc side ripple. Each phase has a pair of IGBT devices which converts the dc voltage into a series of variable-width pulsating voltages, using the sinusoidal pulse width modulation (SPWM) technique. An L-C-L filter is also connected at the inverter ac side. Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1245

Fig4. Complete DG (solar/wind) system model with a damping controller and PCC voltage-control system. 5. REACTIVE POWER CONTROL The conventional reactive power control only regulates the reactive power output of the inverter such that it can perform unity power factor operation along with dc-link voltage control.the switching signals for the inverter switching are generated through two current control loops in - -0 coordinate system.the inverter operates in a conventional controller mode only provided that Switch-2 is in the OFF position. In this simulation, the voltage vector is aligned with the quadrature axis, that is, 0,hence, is only proportional to which sets the reference for the upper control loop involving PI1. Meanwhile, the quadrature axis component is used for dc-link voltage control through two PI controllers (PI-2 and PI-3) shown in Fig. according to the set point voltage provided by the MPPT and and injects all available real power P to the network.to generate the proper IGBT switching signals (gt1, gt2, gt3, gt4, gt5, gt6), the components ( and ) of the modulating signal are converted into three-phase sinusoidal modulating signals and compared with a high-frequency (5-kHz) fixed magnitude triangular wave or carrier signal. Damping Control A novel auxiliary damping controller is added to the PV control system and shown in Fig.5.2. (b). This controller utilizes line current magnitude as the control signal. The output of this controller is added with the signal. The transfer function of this damping controller is expressed as in The transfer function is comprised of a gain, a washout stage, and a first-order lead-lag compensator block. This controller is utilized to damp the rotor-mode oscillations of the synchronous generator and thereby improve system transient stability. The damping controller is activated by toggling Switch-2 to the ON position. This damping controller can operate in conjunction with either the conventional reactive power control mode or with the PCC voltage-control mode by toggling Switch-1 to position B or A, respectively. At first, the base-case generator operating power level is selected for performing the damping control design studies. This power level is considered equal to the transient stability limit of the system with the solar farm being disconnected at night. At this operating power level, if a three-phase Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1246

fault occurs at Bus 1, the generator power oscillations decay with a damping ratio of 5%. The solar farm is now connected and operated in the PV-STATCOM mode. MATLAB/SIMULINK RESULTS Fig 5. MATLAB/SIMULINK Diagram of Complete DG (solar/wind) system model with a damping controller and PCC voltage-control system. Fig 6 pv subsystem Fig7 wind subsystem Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1247

(a) (b) Fig 8 Night time (a) generator power Pg (B) infinite bus power Pinf (a) (b) Fig 9Day time (a) generator power Pg (B) infinite bus power Pinf Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1248

CONCLUSION A novel patent-pending control paradigm of PV solar farms is presented where they can operate during the night as a STATCOM with full inverter capacity and during the day with inverter capacity remaining after real power generation, for providing significant improvements in the power transfer limits of transmission systems [31], [32]. This new control of PV solar system as STATCOM is called PV-STATCOM. The effectiveness of the proposed controls is demonstrated on two study SMIB systems: System I has one 100-MW PV- STATCOM and System II has one 100-MW PV-STATCOM and another 100-MW PV- STATCOM or 100-MW wind farm controlled as STATCOM. Three different types of STATCOM controls are proposed for the PV solar DG and inverter-based wind DG. These are pure voltage control, pure damping control, and a combination of voltage control and damping control. This study thus makes a strong case for relaxing the present grid codes to allow selected inverter-based renewable generators (solar and wind) to exercise damping control, thereby increasing much needed power transmission capability. Such novel controls on PV solar DGs (and inverter-based wind DGs) will potentially reduce the need for investments in additional expensive devices, such as series/shunt capacitors and FACTS. The PV-STATCOM operation opens up a new opportunity for PV solar DGs to earn revenues in the nighttime and daytime in addition to that from the sale of real power during the day. This will, of course, require appropriate agreements between the regulators, network utilities, solar farm developers, and inverter manufacturers. REFERENCES [1] R. M. Mathur and R. K. Varma, Thyristor- Based FACTS Controllers for Electrical Transmission Systems. Hoboken, NJ, USA: Wiley/IEEE, 2002. [2] S. A. Rahman, R. K. Varma, and W. Litzenberger, Bibliography of FACTS applications for grid integration of wind and PV solar power systems: 1995 2010, IEEE working group report, presented at the IEEE Power Energy Soc. Gen. Meeting, Detroit, MI, USA, Jul. 2011. [3] Y. Xiao, Y. H. Song, C.-C. Liu, and Y. Z. Sun, Available transfer capability enhancement using FACTS devices, IEEE Trans. Power Syst., vol. 18, no. 1, pp. 305 312, Feb. 2003. [4] Cross Texas Transmission, Salt fork to gray project. 2014. [Online]. Available: http://www.crosstexas.com/sfwind.htm [5] R. K. Varma, V. Khadkikar, and R. Seethapathy, Nighttime application of PV solar farm as STATCOM to regulate grid voltage, IEEE Trans. Energy Convers., vol. 24, no. 4, pp. 983 985, Dec. 2009. [6] R. K. Varma and V. Khadkikar, Utilization of solar farm inverter as STATCOM, U.S. Provisional Patent, Sep. 15, 2009. [7] R. K. Varma, S. A. Rahman, and R. Seethapathy, Novel control of grid connected photovoltaic (PV) solar farm for improving transient stability and transmission limits both during night and day, in Proc. World Energy Conf., Montreal, QC, Canada, 2010, pp. 1 6. [8] R. A. Walling and K. Clark, Grid support functions implemented in utility-scale PV systems, in Proc. IEEE Power Energy Soc, Transm. Distrib. Conf. Expo., 2010, pp. 1 5. [9] F. L. Albuquerque, A. J. Moraes, G. C. Guimaraes, S. M. R. Sanhueza, and A. R. Vaz, Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator, Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1249

Solar Energy, vol. 84, no. 7, pp. 1310 1317, Jul. 2010. AUTHOR S PROFILE research field. His many research articles are cited by scholars and research institutions. DR. SAMALLA KRISHNA so far has successfully guided many post graduate students in the fields of Signal and Image Processing, Neural Networks and Pattern Recognition while several other students are being supervised by him in a wide variety of other fields like DSP, Medical Image Processing and Object Recognition in addition to this he supervised many electrical and other disciplinary engineering students.he served as an academic supervisor to more than 300 Bachelor Degree dissertations towards the award of Undergraduate Degree,and He has published more than 35 research papers in reputed International Journals. He shared his research experience more than many podiums like conferences, workshops, seminars and symposia. And currently he is working as a professor in TUDI Group of institutions, Hyderabad. He has 12 years of experience in the teaching and MR. S.SRIKANTH is a Post Graduated from the field of Electrical Engineering. He has 3 years of teaching experiences for Graduate and Post Graduate engineering courses. He has published her research work many International Journals and conferences. He guided several engineering students for their academic projects. GUJJA RAVITEJA, PG Student of Electrical, Tudi Ram Reddy Institute of Technology& Sciences, Telangana, India. He did bachelor degree from Vidya Bharathi Institute of Technology, Pembarthy,Telangana, India Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1250