3094PM1ii (Model VS-24-11) & 3094PM4ii (Model VS-24-9)

Similar documents
MODEL DESCRIPTION IN LBS.

ZICO 3094PM1. Model VS REV Retracted. Extended

MODEL DESCRIPTION IN LBS.

ZICO. Center Pull Release in Bostrom 450 Tanker Seat 1026PM5 REV

SAE 5W20, or other clean hydraulic fluid with a viscosity of 150 to 300 SUS at 100 degrees Fahrenheit. System capacity (dry) is 50 ounces.

ZICO* 3096PM1 QUIC-LADDER SWING OUT & DOWN VEHICLE LADDER. Stores ladder parallel to the body.

ZICO 2070PM1 REV Page 1

DESCRIPTION. 10" Square Valve 10" Valve for United Plastics Tank Valve Handle-Complete Assembly Auxilliary Handle Lock less Hardware (see page 12)

SlimRack Bed Lift System OEM INSTALLATION MANUAL

Smart Switch Basic Kit - 24 volt ( ) Wiring Instructions

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits

ZICO 1045PM8. Rev

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Club Car 1515 to Curtis 1268 Conversion

Deluxe High Amp Switch Kit - 12 Volt Wiring Instructions

750 Paso Wiring Upgrade

The Highest Quality Heavy Duty Vehicular Electrical Switches and Components at Competitive Prices

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

Unity Low Voltage Disconnect & Monitor

Electrical Components Bill of Materials (BOM)

Clutch Control. PN: November 2013 Rev E 1

Electrical. Hardware & Fastening Solutions. Battery Supplies. J-Case Fuses - Regular... Page 162

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kit

Installation Instructions for the Plug & Play Chrysler/Dodge/Jeep Remote Start Package w/mux T5

ELECTRONIC DASHBOARD GAUGE DROP-OUT CX, CV AND CH MODEL CHASSIS

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

E90 AVIN Non-iDrive Head Unit Install with Logic 7 Integration

Signal Mirror Installation Instructions

TIP SHEET. Installation Tips for your RS OL-MDB-CH6 (1) (for Jeep vehicles) T1227 v1.0 3/19/14

LIPPERTCOMPONENTS, INC.

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate

CP CP

Remote Start Kit for GM Installation RS1/3/4/7 + ADS-DL Tip Sheet

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

Installing Ignition Coil relay

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

REDUCER BAT/17277: 10/6 T CONNECTORS BAT/17356: 10/10/10 BAT/16295: 10/6/10 BAT/17354: 6/10/6 BAT/21764: 6/6/6 WASH LOCKER

Thank You. for purchasing an Edelbrock Nitrous Oxide Injection System. Please take the time to read and understand the following.

Control Replacement # Page 1 REPLACEMENT OF OBSOLETE SEMI- AUTO CONTROLS WITH KIT #

Installation Tips for your Remote Start system (for Toyota Camry & Prius C, ) Crimestopper RS0+ EVO-ALL T3468 rev#1.

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER


Installation Tips for your Add-on Remote Start (for GM vehicles with INTSL Install 2) v3.2 Updated 11/12/2012

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

Shaved-B. Installation Manual & Operation Instructions

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Installation Guide. Blackhawk G4 and G5 hardware variants, for passenger vehicles, vans and light trucks

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Installation Tips for your Remote Start/Keyless Entry (for Ford Vehicles) v3.3 Updated 1/13/2013

Electrical Wiring Practices

Off Road Only (ORO) LiteSPOTs 8 Light Kit

Installation Instructions For 50330, 50331, 50332, and Off Road Switch Panels

PRODUCT: TJ/LJ Low Profile Led Light Kit READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 7:00 AM 5:00 PM PST

ALTITUDE ARMS AND CANOPY

SUPER LOUD ITALIAN AIR HORN & ULTRA-COMPACT ITALIAN AIR HORN

Two Channel Remote Shutdown Device

ZICO 3097PM6 I. SYSTEMS AVAILABLE INSTALLING THE ACCESS SYSTEM. A. Preparation for Mounting B. Electrical System C. Mounting Suggestions

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

Installation Tips Crimestopper/ProStart Remote Start system + PLJX + DLRM + SPDT (for GM vehicles) T0760 v1.1 updated 2/5/14

Dodge Cummins Positive Air Shutoff

CHEVORLET IMPALA

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Thank you for your interest in the Copper Battery Terminals through the farm magazine.

LBI-30246F INSTRUCTIONS FOR FUSE PANELS 19C327027G1, G2, G4, G5, G8, G9, G10, G11, G14 & G15 AND FILTER PANEL 19D423732G1 DESCRIPTION

Owner s Manual Dual Planetary Gearmotor Auto Programming Slim Rack Slide Out System

Read the entire installation manual. There are several safety tips there that you need to know before you start

THROTTLE & RPM-ACTIVATED NITROUS CONTROL SYSTEM P/N 15970NOS

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Service Bulletin No.: DAC Rev 3 Date Issued: October 27, 1999 Title: 2-Speed Electric Prime Fuel Pump Page: 1 of 8

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

Dodge Cummins Positive Air Shutoff

CP (Vdc) CP (Milliamp) CP (Slidewire)

SPDT DPDT 3PDT 4PDT SWITCHES TACT POS 1 POS 2 POS 3. Model No.

INSTALLATION INSTRUCTIONS

PN DODGE CORONET Two panel Sequential LED Taillight kit installation guide. Kit Contents:

TIP SHEET. Installation Tips for SP-404/SP EVO-ALL + SPDT Remote Start/Alarm T1642

Ford 7.3L Powerstroke Positive Air Shutoff

DriveRight VSS Installation Guide

Bringing Component Parts Together

In-Wall Slide-Out (Winnebago Version) OWNER'S MANUAL

Motorized Electric Latch Retraction

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

AIRSTREAM - BATTERY CONTROL CENTER - Diesel

Owner s Manual Dual Planetary Gearmotor Slim Rack Slide Out System

RR Concepts. The StationMaster can control DC trains or DCC equipped trains set to linear mode.

GateCrafters Automatic Gate Lock Instruction Manual GCLOCK

50 1/50 2 Directional Contactor Installation

GENERAL REQUIREMENTS:

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Dodge Cummins Positive Air Shutoff

FORM # PRINTED IN U.S.A. PAGE 1 OF 11

Smart Switch with External Switch - 12 volt - ( )

INSTALLATION INSTRUCTIONS FOR AIRTECH II / TIE-IN. For Nissan NV

INSTALLATION INSTRUCTIONS SINGLE CHANNEL ISOLATOR

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

Transcription:

QUIC-STEP Retractable Vehicle Step Model VS-24-11 and VS-24-9 InPOWER Control Module Upgrade Manual ZICO 3094PM9 REV. 1-13-17 Note: This manual provides instruction when upgrading a vehicle step from a "terminal post"-style InPOWER Control Module (PN 3094-005-195) to a "plug-in"-style InPOWER Control Module (PN 3094-030-137). The following step manuals may ease the upgrade process or be beneficial for future reference, but are not required: Old InPOWER Module: New InPOWER Module: 3094PM1i (Model VS-24-11) & 3094PM4i (Model VS-24-9) 3094PM1ii (Model VS-24-11) & 3094PM4ii (Model VS-24-9) Manuals are available for download at ziamatic.com. I. Part Information: ITEM PART # DESCRIPTION QTY 58 3094-030-137 InPOWER CONTROL MODULE 1 63 3094-005-198 TERMINAL, FEMALE, MOLEX 33012-3001 7 64 3094-030-139 WIRE HARNESS 1 II. General Information: When the vehicle door is opened and closed, power will flow to Pins 1 (MOT 1) & 5 (MOT 2) for 4 seconds or the power will stop if the amp demand exceeds 12 amps for 100ms. The polarity will also switch from a nominal +12vdc to a nominal -12vdc as the door is closed and opened. If testing the InPOWER unit for voltage across the Pins 1 (MOT 1) & 5 (MOT 2), disconnect the Linear Actuator and connect a 12v test light across the Pins 1 & 5 to cause a current flow (amp draw). (The unit will not operate without a current flow (amp draw).) Connect a volt meter across those terminals and either open and close the vehicle door or place a switch between Pin 2 (Bat (+)) and Pin 4 (INP 1). The light should go on momentary (4 seconds) as the voltage registers a nominal 12v. See "Chart of NC Switch" for the polarity of the pins. When the vehicle door is opened and closed, power will flow to Pins 1 (MOT 1) & 5 (MOT 2) for 4 seconds or the power will stop if the amp demand exceeds 12 amps for 100ms. The polarity will also switch from a nominal +12vdc to a nominal -12vdc as the door is closed and opened.

II. Recommended Tools: Note: The wire harness plug (Item 64) comes with factory installed wires. If hooking the vehicle's wiring directly to the plug is preferred, the following tools are recommended: Tool for Female Terminals (Item 63): Molex 63811-5900 Crimp Tool, 16-14 GA Female Terminals MX150 Series Tool for Wiring Harness Plug (Item 64) Molex 63813-1500 Extraction Tool, MX150 Series III. Preparing to Wire the New Unit 1. On the wires connecting the old InPOWER module to the vehicle (see Figure 1): - Label the wires as (BAT+), (GND), (M2), and (M1) - Label the wire going from the "BAT+" to the vehicle door as (Door BAT+) - Label the wire going from the "Spade Terminal" to the door as (Door Spade) 2. Disconnect the wires from the old InPOWER unit IV. Wiring the New Unit A. Option 1: Attaching the Female Terminals (Item 63) Directly to the Wires from Vehicle 1. Use the Molex 63813-1500 Extraction Tool to remove the female terminals from new wire harness plug 2. Attach Female Terminals (Item 63) to the end of the wires that were labeled in Section 3.1 in accordance with Chart 1 (below) 3. Plug the wires into the new plug in accordance with Chart 1 (below) (for reference, see Figures 3 & 4) 4. Test the unit for proper operation. If the step is operating in the opposite manner, switch the wires going to Pins 1 and 5 Chart 1 Wires Labeled in Section 3.1 New InPOWER Harness lug with wires removed (M1) PIN 1 (MOT1) (BAT +) and (Door BAT+) PIN 2 (BAT) (Door Spade) PIN 4 (INP 1) (M2) PIN 5 (MOT 2) (GND) PIN 6 (GND)

B. Option 2: Splicing the Wires from Vehicle and Existing Wires on New Wiring Harness 1. Temporarily connect the wires in accordance with Chart 2 (below) (For reference, see Figures 3 & 4) 2. Test the unit for proper operation. If the step is operating in the opposite manner, switch the wires going to Pins 1 and 5. Important: It is highly recommended that the wires are soldered together and that shielding on the wire splices is heat sealable to prevent the wires from disconnecting 3. Permanently splice the wires together and test for proper operation Wires that were labeled in step 1 (M1) (BAT +) and (Door BAT+) (Door Spade) (M2) (GND) Chart 2 New InPOWER Wiring Harness PIN 1 (MOT1) (WHITE WIRE) PIN 2 (BAT) (RED WIRE) PIN 4 (INP 1) (BLUE WIRE) PIN 5 (MOT 2) (ORANGE WIRE) PIN 6 (GND) (BLACK WIRE) Note: As the step moves to the fully open or fully closed position, the actuator may make a ratchet sound for a brief moment at the end of the either cycle. This is a safety feature of the actuator.

Figure 1 Existing Wiring Setup

FIGURE 2 - InPOWER Control Module with Wire Harness FIGURE 3 - Control Module Pin Layout CHART FOR NC SWITCH Door Position Switch Polarity Actuator Position Step Open Closed Pin 1 (-) Pin 5 (+) Extends Goes Down Closed Open Pin 1 (+) Pin 5 (-) Retracts Goes Up NOTE: REVERSE ACTUATOR MOTOR POLARITY ON INPOWER MODULE (PIN 1 & PIN 5) IF DOOR SWITCH IS A N.O. SWITCH CONTROL LOGIC

FIGURE 4 - FIELD WIRING DIAGRAM Note: Switch and electrical panel should be mounted in waterproof compartments. Once all electrical connections are complete and system has been tested, protect connections with a weather proofer like liquid tape. MODE OF OPERATION provide power to autostep EXTEND MODE: step will automatically extend as soon as the door is opened. step will remain extended as long as door remains open. RETRACTED MODE: step will automatically retract as soon as the door is closed. step will remain retracted as long as door remains closed.

www.ziamatic.com Ziamatic Corp. TOLL FREE: 800-711-3473 10 West College Avenue, P.O. Box 337, Yardley, PA 19067-0587 (215) 493-3618 FAX: (215) 493-1401 *ZICO is a registered trademark for fire, safety and marine products made by Ziamatic Corp. Copyright Ziamatic Corp. 01-17