THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Similar documents
VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

MCD 200 Series Soft Starters

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Design Guide. VLT Soft Start Controller MCD 100

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Starting Torque Limiter Type TCI (Soft Start)

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Contents. MCD 200 Design Guide. Contents

Section 0.0 Warnings... 2 Section 1.0

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

An Engineering Guide to. Soft Starters

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

Low cost, internally bypassed non optimizing soft starter

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

Operating Instructions VLT Soft Starter MCD 500

RVS-AX Instruction Manual

Pocket Guide VLT Soft Starter the single speed drive

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MAKING MODERN LIVING POSSIBLE. Service Manual VLTp Soft Starter - MCD500 *MG17L402*

A softstarter beyond the ordinary

Starts, stops and protects. Emotron TSA Softstarter

Pocket Guide VLT Soft Starter the single speed drive

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Application Description

RVS-DN Digital Reduced Voltage Motor Starter

USERS MANUAL MCD REMOTE OPERATOR

Softstarters Softstarters

SIRIUS Soft Starters Introduction

ABB Softstarters The new PSS line from 3A to 515A

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

Contactors and Motor Starters. Smoother running. Longer lasting. Electronic contactors and motor controllers. Product overview and selection guide

4491 en / c. D IGISTART et. Reference guide

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

CTi Automation - Phone: Fax: Web:


Variable speed drive or soft starter?

Variable speed application guidelines

PCS compact soft starters

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

3RW Soft Starters. General data. 6/4 Siemens LV

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

RVS-DX Digital Reduced Voltage Motor Starter

For Operation in the Control Cabinet 3RW Soft Starters

Guide to the Application of Soft Starters

Reduced Voltage Motor Starters

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

ABB Softstarter Benefits Charnchanok Thongprad

Softstarters Type PSS. Softstarters. General information

Dimensions WxHxD [mm] Weight [kg]

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

SOLSTART Instruction Manual

Game changing soft starters

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

LH4 Modular Soft Start

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

AuCom - Soft Starters

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

MCD Pump Application Module

EMX3 SOFT STARTER. Take control from the start

Panorama. Softstarters The complete range

AUCOM NORTH AMERICA. Complete range of motor starting solutions

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Operating Guide VLT Soft Starter MCD 500

1.1. Reduced Voltage Motor Starters

a revolution in soft start motor control The future of soft start motor control at your fingertips

CT430 - Soft Starters on Motor Applications

The future of soft start motor control at your fingertips

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

User s Manual: SMARTSTART Series. Models: 6R15 6R830 6V400 6V630

Your choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

MaxPak Plus Analog DC V S Drive

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Operating Instructions. Drives Solutions.

Reduced Voltage Motor Starters

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control


SSW07. Soft Starters. Applications. Standard Features

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

a revolution in soft start motor control The future of soft start motor control at your fingertips

Transcription:

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS MCD 3000 Soft starter

THE PERFECT SOFTENER OF ROUGH STARTS The MCD Soft starter ranging from 7.5 to 800 kw is the optimum solution to a range of problems bound up with direct on-line start of an AC motor, such as: High starting current, often causing an unacceptable load to the mains supply. Shock load on gear and other transmission elements, causing unnecessary wear on mechanical parts. Fast acceleration and deceleration, causing unstable process conditions e.g. in conveyors. start current level. This sometimes means the load cannot accelerate to full speed in star connection, thereby making the star/delta starter totally ineffective. does not impact on the way the motor stops, thus leaving the speed to ramp down without control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters do not however eliminate the risk of a jump in torque when shifting voltage. 2 T N T N Flexibility to changes in the start conditions, increasing flexibility in the application. Soft stop control for extending the motor deceleration time. Braking control to reduce motor deceleration time. Torque Traditionally star/delta and auto transformer starters have been seen as solutions to these problems. However, both these options have drawbacks and do not solve the problems caused by wear of the transmission elements and unstable process conditions. The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. does not allow selection of the best Unlike traditional solutions the MCD 3000 Soft starter offers a wide range of benefits for motor and equipment operation as a whole, including: Flexible control of starting current and torque. Smooth control of current and voltage without any steps or transients. Frequent start/stop operation without mechanical damage Current 6 I N I N SOFT STARTER AUTO TRANSFORMER STAR/DELTA DOL Speed Speed

A Host of Applications The MCD 3000 Soft starter is extremely versatile, offering benefits to almost all motor starting applications. Here you will find some typical examples: Application Pumps Benefits Minimized hydraulic shocks in pipelines during start and stop. Minimized mechanical stress on motor shaft. Reduced starting current. Undercurrent protection preventing damage from blocked pipe or low water situations. Automatic reset functionality ensures continued operation of unmanned pump stations. Phase rotation protection prevents damage from reverse pump rotation. Instantaneous overload protection prevents damage from debris drawn into the pump. Conveyor Belts Controlled start without mechanical shocks, e.g. bottles on a belt do not fall over. Minimized belt stretch. Reduced counter balance stress. Controlled stop without mechanical shocks. Optimum soft start performance even with varying starting loads, e.g. coal conveyors starting loaded or unloaded. Extended mechanical lifetime. No maintenance. Centrifuges Smooth application of torque preventing mechanical stress. Reduced starting times over star/delta starting. Reduced stopping times thanks to DC brake and soft braking. Ski Lifts Jerk-free acceleration increases skiers comfort and prevents swinging T-bars. Reduced starting current allows starting of large motors on a low power supply. Smooth and gradual acceleration whether the lift is lightly or heavily loaded. Phase rotation protection prevents operation in reverse direction Compressors Reduced mechanical shocks extend the life of the compressor, couplings and motor. Limited start current enables large compressors to be started even when maximum power capacity is limited. Phase rotation protection prevents operation in reverse direction. Instantaneous overload protection prevents possible damage from liquid ammonia entering the compressor screw. Band saws Reduced time for saw band replacements since the soft braking function stops the motor quickly. Extended saw band life thanks to eliminated torque shocks during start. Easier saw band alignment. Slow acceleration allows saw bands to be 'tracked' without jogging. Maximum overload capability available for ride-through of operating overloads. The MCD 3000 Soft starter motor thermal model accounts for the actual overload capability of the connected motors and will trip only if absolutely necessary. Chippers Reduced starting current. Instantaneous overload trip prevents mechanical damage from jammed loads. Reduced deceleration times due to use of braking function. Crushers Maximum overload capability available for ride-through of operating overloads. The MCD 3000 Soft starter motor thermal model accounts for the connected motors actual over load capability and will trip only if absolutely necessary. Maximum start capability available for starting if crusher stops while not completely empty. The MCD 3000 Soft starter motor thermal model accounts for the actual overload capability of the connected motors and will allow the motor to provide start torque for the longest time possible.

Working principle Motor voltage is controlled by means of a phase cut principle. Two thyristors in each phase perform the power switching, enabling the starter to handle high starting torque and frequent starts/stops. Current transformers measure the motor current providing feedback for constant current control of motor starting, and also for numerous motor and application protection functions. Technical data MCD 3000 Soft starter Model Bookstyle Rated Current (Amps) AC53a 3-30:50-10 Dimensions (mm) H W D Protection Format MCD3007 -T5/-T7 21 530 132 270 IP 21 Book style (B21) MCD3015 -T5/-T7 35 530 132 270 IP 21 Book style (B21) Power Connection Cabling Mains, motor and bypass connectors: Bar type with thread for fastening bolts for cable shoes. Control cable connections: Terminal block for 0.14 m~1.5 m 2 /26~16 AWG. Control card supply connection: Terminal block for 2.5~4 mm 2 / 14~12 AWG The bottom plates are removable and include a drilling template for cable entries. Short circuit protection For proper protection semiconductor fuses must be used in front of the starter. Control inputs Start/stop. Can be configured for both two-wire and pulse (four-wire) start/stop commands. Reset. Parameter set. For selection between two motor parameter sets. Signal outputs Three relay outputs (programmable) for control of: Line, Bypass and DC brake contactors. Run, Trip, Output on, and High/low current flag. Bypass If the soft starter is mounted in a cabinet without ventilation, a bypass contactor should be applied to prevent heat dissipation during operation. The starter has built in bars for connection of a bypass contactor. This allows the MCD 3000 Soft starter to measure motor current and retain all motor protection functions even when the bypass contactor is closed. EMC Compliant with the requirements in the product standard IEC 947-4-2, AC semiconductor motor controllers and starters. MCD3018 -T5/-T7 41 530 132 270 IP 21 Book style (B21) MCD3022 -T5/-T7 50 530 132 270 IP 21 Book style (B21) MCD3030 -T5/-T7 69 530 132 270 IP 21 Book style (B21) MCD3037 -T5/-T7 88 530 132 270 IP 21 Book style (B21) MCD3045 -T5/-T7 96 530 132 270 IP 21 Book style (B21) MCD3055 -T5/-T7 125 530 132 270 IP 21 Book style (B21) Compact MCD3075 -T5/-T7 141 530 264 270 IP 21 Compact (C21) MCD3090 -T5/-T7 202 530 264 270 IP 21 Compact (C21) MCD3110 -T5/-T7 238 530 264 270 IP 21 Compact (C21) MCD3132 -T5/-T7 254 530 396 270 IP 21 Compact (C21) MCD3185 -T5/-T7 364 850 430 280 IP 20 Compact (C20) MCD3220 -T5/-T7 430 850 430 280 IP 20 Compact (C20) MCD3300 -T5/-T7 546 850 430 280 IP 20 Compact (C20) MCD3315 -T5/-T7 630 850 430 280 IP 20 Compact (C20) MCD3400 -T5/-T7 775 850 430 280 IP 20 Compact (C20) MCD3500 -T5/-T7 897 850 430 280 IP 20 Compact (C20) MCD3600 -T5/-T7 1153 1000 560 315 IP 20 Compact (C20) MCD3700 -T5/-T7 1403 1000 560 315 IP 20 Compact (C20) MCD3800 -T5/-T7 1570 1000 560 315 IP 20 Compact (C20) Power Supply voltage: 3 200-525 VAC -T5 3 200-690 VAC -T7 Please specify voltage range at ordering. Supply frequency: 50/60 Hz Control voltage: 230 V (+10%/-15%) 400 V (+10%/-15%) Other control voltages can be accommodated by fitting an optional transformer within the starter. Ambient max temperature 40 C Approvals: UL(pending), CE, CSA, C Thermistor input Trip level at >2.8 kohm Busbar 4 16 mm Tap with 6 mm thread Busbar 5 16 mm Tap with 8 mm thread Busbar 6 22 mm Tap with 8 mm thread Busbar 6 24 mm Tap with 10 mm thread Busbar 13 32 mm Hole for 10 mm bolt Busbar 16 51 mm Hole for 12 mm bolt Model selection Model selection should not be based on motor size only. Consideration must also be given to required start current level. The AC53a 3-30:50-10 ratings above allow for 3 times Full Load Current (In), 30 s Start Time, 50% On Load Duty Cycle, 10 Starts Per Hour. If operating conditions differ from this, a different model may be required. Ordering should be done by means of type code strings: MCD 3xxx-T5 or T7-C20, C21 or B21-CV4 (control voltage) e.g. MCD3055-T5-B21-CV4 (55 kw at 400 V, 200-525 V, Bookstyle, IP21, control voltage 230 V and 400 V).

PROTECTION AND EASY HANDLING The MCD 3000 Soft starter is second-to-none when it comes to compensating for the drawbacks of direct on-line starting and stopping of AC motors. In addition it offers the most comprehensive protection of motor and application in the market, including: Motor Continuous monitoring of motor load for calculating motor temperature. The value is shown in the display as percentage of maximum temperature, and the function is active even when the power section is bypassed. Application Undercurrent protection. Particularly useful for ensuring that pumps do not run dry. Shear pin protection. Ensures detection of foreign bodies blocking operation. Phase sequence protection. Prevents machinery from running in reverse. Phase imbalance protection. Completing the picture Danfoss has added a range of user-friendly benefits to the MCD 3000 Soft starter. Among them are: Easy installation MCD 3000 Soft starter is truly wall mountable, offering ample space for glanding and terminating the cables. Side-by-side mounting without clearance (larger sizes only with 100 mm clearance). No optional equipment required to perform any tasks. Easy operation Only one parameter to adjust for basic operation. Only a few parameters to adjust for high level control and protection. No need for field calibration to ensure correct operation. The MCD 3000 Soft starter has a factory accuracy of ±5% for current measurement. Built-in local control panel with display. Quick set-up. Numeric display for programming or showing *current *motor temperature * fault code Starter status LED s *START. Voltage has been applied to the motor *RUN. Full voltage has been applied to the motor *TRIP. The starter has tripped *REMOTE. The motor is controlled via external control signals 1 2 2 1 3 4 Programming buttons 3 Operational buttons for control of motor when in Local mode (can be selected by means of the LOCAL/REMOTE button) 4 Control input (digital) status LED s 5 5

MOTOR CONTROL AT A NEW LEVEL With the MCD 3000 Soft starters Danfoss is once again contributing to optimum motor control, offering perfect protection and operation for virtually all AC motors. This step is a logical continuation of our untiring endeavours since we invented the first mass produced electronic frequency converter back in 1968. Ever since, frequent technological breakthroughs and constant extensions of the motor outputs covered have been our hallmark. Today we offer VLT drives for motor outputs from 0.37 kw to 500 kw, and supply voltages from 200 V to 240 V and 380 V to 500 V. This range makes it possible to find a Danfoss drive for practically all purposes. With Danfoss as partner you get the complete package. We develop, manufacture and market Bauer geared motors which provide the correct amount of torque to meet any customer requirement including operation under extreme conditions like high and low temperatures, dust, wetness and hazardous areas. We do, however, offer more than quality products. Our global team of experts is ready to assist with application, engineering, commissioning, training and service. And our organisation is at your disposal around the clock in 120 countries. www.danfossdrives.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. DKDD.PB.05.A1.02 VLT is a trademark of Danfoss A/S Produced by Danfoss G1 advertising agency 99.11.UF.V.VE.LS