DC REGULATED POWER SUPPLY

Similar documents
DC REGULATED POWER SUPPLY

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model 1672, 1673 Triple Output Power Supply

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

DC POWER SUPPLY ALIMENTATION C.C.

Model 1693, 1694 Switching DC Power Supply

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Triple Output Power Supply

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

INSTRUCTION MANUAL Model 1743B

Model 1900, 1901, 1902 Switching DC Power Supply

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

SLA Battery Capacity Analyzer

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Model 1900, 1901, 1902 Switching DC Power Supply

Triple Output High Resolution Power Supply. User Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Switching DC Power Supply

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

DC POWER SUPPLY GPS-S SERIES (ANALOG 1 DIGITAL TYPE) User Manual ISO-9001 CER TIFIED MANUFACTURER

Instruction Manual. Model 310 Digital Milli-Ohm Meter

3000 Series Operation Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Digital/Analog Megohmmeter Model 1026

DC POWER SUPPLY (Switching mode)

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

3.00 A 30.0 V. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com CURRENT FINE VOLTAGE POWER - GND + C.

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Declaration of Conformity

Mini Multimeter with Non-Contact Voltage Detector (NCV)

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

True RMS Autoranging Multimeter

Power supply HM7042-5

Autoranging Multimeter

SECTION DC POWER SUPPLY/BATTERY CHARGER

Model P772 Conductivity Meter. User Manual

A1P OPERATING MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Chapter 9 Basic meters

Declaration of Conformity

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Using Your SMT Micro Anodizer 0-120VDC/0-1A

Digital Multimeter AHMAD FOUAD ALWAN

LAB 7. SERIES AND PARALLEL RESISTORS

EPS/ELA-Series User Manual EPS/ELA 250W

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

5.2 PRE-OPERATION PROCEDURE WARRANTY

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

SAFETY TERMS AND SYMBOLS

RESISTIVITY MONITOR/CONTROLLERS

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

PowerOhm Installation Manual for BM R Series Braking Modules

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Dawson DAN100. Analog Multimeter User s Manual

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

RU BMS Power Supply and Battery Management System Owners Guide

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

PROwatt 150 DC to AC Power Inverter. Owner s Guide

Autoranging Industrial Multimeter

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

User s Manual Power Supply IM E. 5th Edition

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

A6Z OPERATING MANUAL

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

DIGITAL MULTIMETER INSTRUCTION MANUAL

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Table of Contents Title Page No.

INSP-3 Wiring Inspection Tester

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Transcription:

INSTRUCTION MANUAL Models 1620A/ 1621A/ 1622A/ 1623A/ 1626A/ 1627A DC REGULATED POWER SUPPLY Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

TABLE OF CONTENTS 1. INTRODUCTION... 3 2. FEATURES... 3 3. SPECIFICATIONS... 4 4. PRCAUTIONS FOR USE... 6 4.1 Confirming the supply range... 6 4.2 Precautions for connection of output terminals... 6 4.3 Operating environment... 7 5. EXPLANATION OF PANEL... 7 5.1 FRONT PANEL... 7 5.2 REAR PANEL... 9 6. OPERATION PROCEDURES... 10 6.1 Stand-alone operation... 10 6.2 Serial connection... 10 6.3 Parallel operation (MASTER / SLAVE Control)... 11 7. MAINTENANCE...13 7.1 Main fuse replacement...13 7.2 Calibrations...13 7.3 Voltage calibration...14 7.4 Voltmeter alignment...14 7.5 Current calibration...14 7.6 Ammeter alignment...14 LIMITED WARRANTY...15 SERVICE INFORMATION...16 2

1. INTRODUCTION The BK Precision Analog and Digital series are high quality serial control type DC Regulated Power Supplies. These models can be operated at constant voltage or constant current mode whose output can be varied from 0 up to the rated values for respective model. It is a compact unit provided with separate voltage and current meters (Analog for 1620A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) for monitoring the output voltage and current simultaneously. In terms of operability, these units enable high precision, continuous variability via coarse and fine adjust knobs. The BK Precision Analog and Digital series can be connected in parallel with multiple units of the same model set up a master/slave configuration to increase the output current capability. Serial connection of multiple units can be used to increase the output voltage level. This family of power supplies provides clean and stable DC output which is most suitable for many areas including laboratory, industrial, field service, hobby, and telecommucation applications. 2. FEATURES The BK Precision Analog and Digital series are constant voltage / constant current power supplies which feature excellent line and load regulations, low ripple and noise characteristics. The units feature separate voltage and current meters so that output voltage and current can be monitored simultaneously. Output voltage and current can be adjusted continuously in full range to any desired values. Adjustment can be done easily and precisely by using separate coarse and fine adjust knobs. The constant current circuit operates to protect against overload and output short circuit. The limiting current values can be preset in the full range of the rated values for respective model. Multiple units of power supplies of same family can be connected in series to provide higher output voltage. Multiple units of power supplies of SAME model can be connected in parallel (master / slave configuration) to achieve higher output current. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 3

3. SPECIFICATIONS 1620A 1626A 1622A 1621A 1627A 1623A OUTPUT VOLTAGE 0-18V 0-30V 0-60V 0-18V 0-30V 0-60V OUTPUT CURRENT 5A 3A 1.5A 5A 3A 1.5A CONSTANT VOLTAGE CHARACTERISTICS Load regulation (0-100%) 0.02% +3mV Line regulation (120VAC + 10 %, -6 % ) Ripple and noise r m.s CONSTANT CURRENT CHARACTERISTICS Load regulation (0-100%) Line regulation (120VAC + 10 %, -6 % ) OUTPUT Output terminals ( color ) Ground proof voltage INSTRUMENTATION 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 4 1mV max. 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA ( + ) Red, ( ) Black, ( GND ) Green ± 180V Voltmeter Analog 3 digits LEDS Ammeter Analog 3 digits LEDS Voltmeter accuracy ± 7% fs ± 2% + 2 digits Ammeter accuracy ± 7% fs ± 2% + 2 digits

FUNCTIONS Serial connection ( independent control mode ) Parallel operation ( master slave mode ) COOLING SYSTEM POWER CONSUMPTION VA / W ( for rated load of AC 220V ) AC INPUT Voltage, Frequency Can be connected in series ( within limits of ground proof voltage ) Can be operated in one-control parallel configuration ( only same model ) Natural Convection Approximate 210 Approximate 220 120V AC ± 10%, 60 Hz (120/220/230/240V AC ± 10%, 50/60Hz version available) Operating ambient temperature 5 to 40 C 10 80% R.H. DIMENSIONS AND WEIGHT Dimensions ( W x H x D ) 205 x 115 x 270 ( mm ) Weight Approximate 6 Kgs Approximate 7.4 Kgs FUSE RECOMMENDED Input fuse F2 AC 100V, 110V, 120V AC 220V, 230V, 240V Internal fuse F1 NOTE: Specifications and information are subject to change without notice. 3AF 2AF 500mAF 5

4. PRECAUTIONS FOR USE 4.1. CONFIRMING THE SUPPLY RANGE The unit must be used within its specified range. The rated input voltage can be found on the rating table under the unit. Before plugging into the AC supply outlet, check if the input rating conforms to your local supply. For certain models, a voltage selector is available, switch the voltage selector to the correct position before use. Also, please check that you have the correct fuse inserted in the fuse box below the AC input receptacle. 4.2. PRECAUTIONS FOR CONNECTION OF OUTPUT TERMINALS These units are a floating type power supply. For ordinary use, be sure that the MASTER/SLAVE switch on the rear panel is set to MASTER position and either the (+) output terminal or the ( ) terminal is connected to the GND terminal (chassis GND) via the shorting bar. 4.3. OPERATING ENVIROMENT Be sure to use this unit within the specified ambient temperature range listed in the specification table. Because the unit is cooled by natural convection, do not place objects on top to block the convection. Also user must avoid placing the unit on or near any heat emitting devices or use multiple units in stacked configuration. For best results, use the unit in an environment that has good cross-ventilation. Altitude up to 2000M Installation category: CAT II Pollution degree: 2 Indoor use only Warning: For model 1622A and 1623A, the maximum output voltage is up to 60Vdc. Touching the live metal part of output terminals may be hazardous. User must avoid touching the live metal part of output terminals. 6 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

5. EXPLANATION OF PANELS 5.1 FRONT PANEL Fig. 5.1 7

1. Power switch Turns the power supply ON-OFF. The switch will be lighted up when the unit is ON. 2. DC Voltmeter Indicates the present output voltage. (Analog for 162A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) 3. DC Ammeter Indicates the present output current. (Analog for 162A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) 4. Constant current mode (C.C.) indicator Indicates the power supply is operating in constant current mode. 5. Constant voltage mode (C.V.) indicator Indicates the power supply is operating in constant voltage mode. 7. Voltage fine adjust Fine adjust knob for the output voltage in voltage mode. 8. Current coarse adjust Coarse adjust knob for current limiting point and current value in constant current mode. 9. Current fine adjust Fine adjust knob for current limiting point and current value in constant current mode. 10. Output terminal positive (+) Terminal for tapping of positive (+) output. 11. Output terminal negative ( ) Terminal for tapping of negative ( ) output. 12. Ground terminal (GND) Chassis ground terminal. Normally, this is connected to either (+) or ( ) terminal depend on application. 6. Voltage coarse adjust Coarse adjust knob for the output voltage in voltage mode. 8

5.2 REAR 13. Master / Slave switch Used during master / slave control parallel operation in MASTER / SLAVE configuration. For normal operation, switch should be set to MASTER. 14. In / out terminals for Master / Slave operation Control terminals for use in the MASTER / SLAVE control parallel operation mode. 15. Heat sink Heat sink for the power supply. Be careful as this area can become quite hot during operation. 16. Main Fuse 17. Power cable Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 9

6. OPERATION PROCEDURES 6.1. STAND-ALONE OPERATION When using the power supply in stand-alone mode, simply operate by manipulation of the panel switches and adjustment knobs as needed. However, be sure that MASTER / SLAVE switch is set to MASTER position. PLUS / MINUS CONNECTION For connection as shown in FIG.6.2 where the intermediate point is hooked up to ground, the configuration can be used as Plus / Minus power supply. 6.2. SERIAL CONNECTION Two or more units of the power supply can be hooked up in series to achieve higher output voltage. The resulted output will be sum of the outputs of the individual units. In this situation, however, care must be taken that the voltage of neither of the terminals with respect to the chassis GND exceed the ground proof voltage of + 180V FIG. 6.1 SINGLE VOLTAGE CONNECTION For connection as shown in FIG.6.1, the output voltage will be the sum of individual supplies and output current will be limited to within the value specified for a single unit whichever is lower. For positive ground terminal to output positive point and for negative ground system, hook-up the ground terminal to the negative output point. FIG. 6.2 10

6.3. PARALLEL OPERATION (MASTER / SLAVE CONTROL) Two or more units of the same model can be hooked up in parallel to give an increase in output current capacity. The total output current capacity will be the sum of the output currents of the individual units. In this mode of operation, one supply will act as the master and all settings are from the master unit Note: When connecting the supplies in parallel, be sure that all the power supplies are turned OFF. HOOK-UP PROCEDURES 1. Switch OFF the power of all units. 2. Switch the master/slave switch, FIG.6.3, on all the slave units from MASTER to SLAVE position. 3. Hook-up the IN/OUT terminals for MASTER/SLAVE operation as shown in FIG.6.3. 4. Connect the output terminals of each of the units to the load as shown in FIG.6.4. For proper performance, use all cables of same length and thickness. 6. Switch ON the MASTER unit and SLAVE units. The output voltage and current then can be controlled to the desired value via the adjustment knobs on the MASTER unit. In the case of output goes to 0 ampere in the parallel operation mode, output voltage can no longer be controlled by the master machine. Be sure to keep a minimum current flowing that is at least several percent of the rated current at all time. CONNECTION OF TERMINAL ON REAR PANEL While pressing on the slit portion of the terminal with a small screw driver, insert the connecting cable into the round hole. When insertion is completed, release the screw driver. (FIG.6.5) 5. Set the voltage and current adjustment knobs of all the slave units to the maximum position. 11

FIG. 6.3 FIG. 6.4 FIG. 6.5 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 12 TestEquipmentDepot.com

7. MAINTENANCE WARNING: The following instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing other than those contained in the operating instructions unless you are qualified to do so. 7.1 MAIN FUSE REPLACEMENT However, calibrations should be attempted only if a 3½ digit multimeter with an accuracy of +0.5% DCV or better and a 0 to 50ohm, 250 Watt adjustable resistive load is available. If re-calibration is required, use the following procedures. Locations of the electrical calibration on the main PCB are shown in FIG. 7.1. If the main fuse blows, the power on the LED indicator will not light and power supply will not operate. The fuse should not normally blow unless a problem has developed in the unit. Try to determine and correct the cause of the blown fuse, then replace only with a fuse of correct rating. The fuse is located on the rear panel and fuse rating can be found next to the fuse holder. If the problem persists, return the unit to the agent for further investigation. 7.2 CALIBRATION This unit has accurately calibrated at the factory before shipment. Recalibration is recommended only if repairs have been made in a circuit affecting calibration accuracy, or if you have reason to believe the unit is out of calibration. FIG. 7.1 13

7.3. VOLTAGE CALIBRATION 1. Connect the multimeter to measure the DC voltage across the power supply (+) and ( ) output terminals. 2. Turn on the power supply, and turn the panel VOLTAGE adjustment knob fully clockwise (maximum output). 3. Adjust trimmer VR11 for a reading (Vmax. +0.5) ±0.1 volts on the multimeter. Vmax is the maximum normal output of the specific model under calibration. 7.4. VOLTAGE ALIGNMENT 1. Set the output voltage to about half the maximum allowable output for respective model. 2. Align the voltmeter reading with the multimeter reading. For BK Precision Analog series, adjust the trimmer VR-6 on the main PCB. For BK Precision Digital series, adjust the trimmer VR-1 on the back of meter PCB. 7.5. CURRENT CALIBRATION 1. Connect the 0 50ohm / 250W resistive load in series with the multimeter to measure the DC output current terminals. 14 2. Adjust trimmer VR-5 fully anti-clockwise (referring to the component side). 3. Adjust the output voltage to the maximum allowable output for respective model. 4. Adjust the variable resistive load to obtain (Imax +0.1) ±0.02 Ampere on the multimeter. Imax is the maximum nominal allowable output current of resistive model. 5. Adjust trimmer VR-5 clockwise slowly until the limiting point is just reached and the C.C. LED lights up at the same time. 7.6. AMMETER ALIGNMENT 1. Adjust the output voltage to half of its maximum allowable output voltage for respective model. 2. Adjust the variable resistive load to obtain half of its maximum allowable current for respective model. 3. Align the ammeter reading with the multimeter reading. For BK Precision Analog series, adjust the trimmer VR-7 on the main PCB. For BK Precision Digital series, adjust the trimmer VR-2 on the back of meter PCB. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

15

Service Information Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging with proof of purchase to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Customers not on an open account must include payment in the form of a money order or credit card. For the most current repair charges please refer to the service and support section on our website. Return all merchandise to B&K Precision Corp. with prepaid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping. Return shipping to locations in North America is included for Warranty Service. For overnight shipments and non-north American shipping fees please contact B&K Precision Corp. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 Include with the returned instrument your complete return shipping address, contact name, phone number and description of problem. 16

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Printed in China PN# 481-375-9-001 v121417 2014-2017 B&K Precision Corp.