UNV DC Engines Retrofit Kits with 0-0V Dimming Universal Voltage (20~277) DC Engine culus Classified 598C Suitable for open or fully enclosed luminaires culus Recognized 8750 Suitable for luminaires with plastic and glass lenses Energy Star Luminaire 2. Listed and CSD Class 2 design 4lm/W at system level General Specifications Input Voltage Input Current Input Power Input PF THD Input Frequency Module Operating Voltage Max Lumen Output @ Full Power Dimming Type/Range Beam Angle CRI Storage Temperature Range Operating Ambient Temperature Range (Ta) Maximum Driver Case Temperature: per UL/ 5 year warranty Maximum Module Case Temperature Estimated Lumen Maintenance (at Max ) Color Consistency Inrush Current / Duration Line Regulation / Load Regulation Total Overall Ripple LF (<300Hz)/ HF(<40kHz) peak to peak Low Frequency Ripple (20Hz ripple peak to peak) Flicker Percentage Overall Size Wire Type/ Length LED Quantity Driver Part Number Module Part Number Weight Packaging: Master Carton Maximum Screw Installation Torque Safety/Compliance 2 2 2 Start-up Time / Standby Power RFI/EMI Input Surge Test Sound Rating / Noise Output Type PCB Material / Connector Qty / Em. Connection Warranty 2 20~277VAC (+/- 0%) ~0.66A @20V ~0.072A @277V 20W >0.98 <20% 50/60Hz 23.VDC 2675 lumens @ 4000K / 80 CRI 0-0V / 00% ~ 0% 20 80 (standard), 90 available (MTO) -35 C to 00 C / -3 F to 22ºF -35 C to 60 C / -3 F to 40ºF 90 C (94 F)/ 76 C (76 F) L70: max=05 C (Ts=0 C) / L90: max=05 C (Ts=0 C) L70= >60,000 hours / L90= 40,000 hours Binning per ANSI C78.377-205 @25 C; 3 SDCM 20A @ 277V / 250us <% @00% Load / <3% @00% Load <5% @00% Load <5% @00% Load <7% @00% - 20% Dimming Range <5% @<20% Dimming Range <500ms / <0.5W No Load 7.83 Dia. x.8 H (99mm Dia. x 29.89mm H) 8AWG / 2 Black and White wires (Input 20~277VAC) 8AWG / 2 Gray and Purple wires (Dimming 0-0VDC) 48 Pcs. TMUNV0700-30L VMU095023RDxxxA 320g / 0.7lbs. 20pcs 35in-lb (560in-ozf) Component: curus Module File #E35548; Driver File #E342838 DC Engines Retrofit Kits: culus Classified 598C File # E36524 Compliant Dry and Damp Location Energy Star Luminaire 2. Listed and CSD FCC Part 5B Consumer, EN5505 2.5kV Common and Differential mode (Per ES Ring Wave Test) A / <24 dba Class 2 (approved for luminaires glass or plastic lenses) CEM / 2 / Yes 5 years @ Max. 05 C (module) and 76 C (Driver) from the date of manufacture See page #4 Certification Chart for exact models. 2 Measured electrical data per UL file Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page of 4 208-777 Rev B
Typical Characteristics Graphs: Dimming and Thermal Figure Figure 2 20 0-0V Dimming Curve 30 Lifetime vs ase 00 0 Io(%) 80 60 40 Lifetime (KHrs s) 90 70 50 20 30 0 0 2 3 4 5 6 7 8 9 0 Dimming Voltage (V) 0 50 55 60 65 70 75 80 85 90 ase( ) Failure Rate Info based upon MTBF modeling: 90% survivals at end of life @ <= lifetime rating Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 2 of 4 208-777 Rev B
Electrical and Optical Specifications Color Temperature 2700K DC Engine Retrofit Kit Part Number VKMUNV08RD827A Input Power 20W Nominal Luminous Flux @ 90 CRI 280 lumens Engine Efficacy @ 90 CRI 09 lm/w Nominal Luminous Flux @ 80 CRI 2600 lumens Engine Efficacy @ 80 CRI 30 lm/w 3000K VKMUNV08RD830A 20W 2360 lumens 8 lm/w 2680 lumens 34 lm/w 3500K VKMUNV08RD835A 20W 2340 lumens 7 lm/w 2720 lumens 36 lm/w 4000K VKMUNV08RD840A 20W 2400 lumens 20 lm/w 2820 lumens 4 lm/w 5000K 5700K 6500K VKMUNV08RD850A VKMUNV08RD857A VKMUNV08RD865A 20W 2440 lumens 22 lm/w 2860 lumens 43 lm/w 20W 2440 lumens 22 lm/w 2860 lumens 43 lm/w 20W 2400 lumens 20 lm/w 2820 lumens 4 lm/w ) Electrical and optical specifications are based on mod = 25ºC. Reference Amb. Temp. vs Rel. Lum. Flux for other temperatures. 2) Nominal luminous flux at 90 CRI are calculated values, not measured. 3) Performance for these components have been tested in accordance with Energy Star. 4) Refer to Energy Star CSD or Luminaires 2. for actual measurements on specific part numbers. Energy Star testing is done at elevated case temperature. 5) Specifications are subject to change without notice. 6) 70CRI is NOT available. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 3 of 4 208-777 Rev B
Thermal Specifications Storage Temperature Range Operating Ambient Temperature Range Maximum Driver Case Temperature Maximum Module Case Temperature 3 DC Engine Retrofit Kit (A) -35 C to 00 C / -3 F to 22 F -35 C to 60 C / -3 F to 40 F 90 C / 94 F L70 = 05 C (22 F) / L90 = 05 C (22 F) located on module located on driver Thermal De-Rating: vs. Luminous Flux Module Case Temperature () 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC 75ºC 80ºC 85ºC 90ºC 95ºC 00ºC Total Vf Multiplier.000.000 0.997 0.993 0.993 0.990 0.987 0.987 0.984 0.984 0.980 0.977 0.977 0.974 0.970 0.967 Luminous Flux Multiplier.000 0.99 0.982 0.973 0.964 0.953 0.944 0.935 0.926 0.97 0.908 0.899 0.889 0.880 0.862 0.853 ) Refer to DC Engine Retrofit Kit Installation Instructions for further detail. 2) This DC Engine Retrofit Kit can retrofit any luminaire with a dimension/volume greater or equal to the minimum dimensions shown below and on the Installation Instructions. 3) This DC Engine Retrofit Kit can be used with luminaires similar to the one illustrated on the Installation Instructions. 3 Suitable for surface mounted luminaire with minimum dimensions or volume: 0" diameter with a height of 3" or 30 cubic inches Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 4 of 4 208-777 Rev B
Certification Chart Energy Star TM-2 Calculator Data Classification Model Listed CSD YES YES (Driver & Module) YES YES YES Module Reported L70 Reported L90 55 C >60,000 Hrs >54,000 Hrs 85 C >60,000 Hrs 46,000 Hrs 05 C >60,000 Hrs 40,000 Hrs Module Calculated L70 Calculated L90 55 C 80,000 Hrs 54,000 Hrs 85 C 54,000 Hrs 46,000 Hrs 05 C 33,000 Hrs 40,000 Hrs ) Energy Star CSD: https://www.energystar.gov/products/lighting_fans/certified_lighting_subcomponent_database_csd 2) Energy Star Listed: https://www.energystar.gov/productfinder/product/certified-light-fixtures/results?scrollto=342&search_text=fulham&fixture_type_isopen=&markets_filter=united+states &zip_code_filter=&product_types=select+a+product+category&sort_by=light_output_lumens&sort_direction=asc&page_number=0&lastpage=0 Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 5 of 4 208-777 Rev B
.8 Mechanical Drawings (Scale 3 : 5) TOP VIEW ø7.83 (ø99mm) ø0.44 (ø.8mm) ø0.9 4x (ø4.78mm 4x) Driver Module Overall Dimensions Diameter Height AC Input (Black / White) 7.83 [99mm].8 [29.89mm] Wire Length 2 [304.8mm] 7.40 (88mm) 0-0V Dimming Purple (0v+) Gray (0V-) 2 [304.8mm] Connector for Emergency Input 7.40 (88mm).3 (33mm) ø0.44 thru (ø.8mm thru).3 (33mm) 0.7 (7.78mm).5 (38.mm) (45.7mm) 0.9 (22.8mm) 0.9 (22.8mm) SIDE VIEW PARTIAL VIEW.8 (29.89mm) Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 6 of 4 208-777 Rev B
DC Engine Retrofit Kit Equivalency Chart: FLUO to LED DC Engine Retrofit Kit Part Number DC Engine Retrofit Kit (7.83 Round) System Wattage 8W Lumen Output 2820 lm (4K/80CRI) Efficacy 4 lm/w CFL Style Quad Triple Quad Triple Circline T5 Circline T9 Lamp Wattage 3W 8W 3W 8W 3W 26W 3W 26W 22W 22W # of Lamps Total Wattage 2 2 CFL 3W 8W 3W 8W 26W 26W 26W 26W 22W 22W Lumen Output 775 lm 075 lm 825 lm 020 lm 550 lm 650 lm 536 lm 530 lm 775 lm Efficacy 59 lm/w 63 lm/w 56 lm/w 59 lm/w 63 lm/w 59 lm/w 69 lm/w 35 lm/w ) LED is a point source and FLUO is 360, there is more light lost with FLUO especially during the reflection. Therefore it is recommended to use a 65 percent of the original light source total lumens when converting FLUO to LED. For example original FLUO lumens of 2000 x.65% = 300 LED lumens. This is only a recommendation, and the installer should consider other factors for the application. 2) For reference only, several factors apply. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 7 of 4 208-777 Rev B
DC Engine Retrofit Kit with Emergency Options DC Engine Retrofit Kit Part Number VKMUNV08RD840A Emer. Driver Part Number Battery Wattage Battery Part FHSBATT8-AA9 Number FHSBATL6-.6 Harness (ma) FHS-HARNESS-250 NOTE: Emergency systems are not UL classified for field installation. LED Vf (V) Total Power (W) Total Lum. Output (lm) Eff. (lm/w) FHS2-UNV-36L/ FHSBATT8-AA9 5 4W FHS-HARNESS-75 2.5 75 3.8 720 9 FHS2-UNV-56S FHSBATL3- FHSCP-UNV-5WL 5W N/A N/A 2.8 228 5.0 934 87 FHSCP-UNV-0P-L-SD FHS2-UNV-36L FHSCP-UNV-0P-L-SD FHSCP-UNV-7.8WL FHS2-UNV-36L/ FHS2-UNV-56S FHS2-UNV-36L FHSCP-UNV-0P-L-SD FHSCP-UNV-0.7WL FHSCP-UNV-3.7WL FHS2-UNV-36L/ FHS2-UNV-56S FHSCP-UNV-7WL 5W 6W 6W LED If (ma) FHSBATL3-.5-SD N/A 2.8 228 5.0 934 87 5 2.8 250 5.5 022 87 FHSBATL9-.6-SD N/A 2.9 368 6.0 24 87 7.8W N/A N/A 22.2 354 7.8 428 83 FHSBATL3-.5 5 8W FHS-HARNESS-350 22.2 350 7.8 42 82 FHSBATL3-.5S 5 0W FHSBATL9-.6 FHS-HARNESS-450 22.4 450 0. 79 78 0W FHSBATL3-3-SD 4 FHSBATL6-.5L-SD N/A 22.4 444 0.0 769 77 0.7W N/A N/A 22.5 474 0.7 880 76 3.7W N/A N/A 22.8 600 3.7 2328 70 6W FHSBATL3-3 FHS-HARNESS-650 5 22.9 650 4.9 2496 68 7W N/A N/A 23. 735 7.0 2772 63 ) For reference only, several factors apply. 2) Emergency systems are not UL classified for field installation. 4 5 These batteries do not include mounting means, separate mounting brackets are available Initial lumen output. Will reduce to no less than ~65% of total lumen output. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 8 of 4 208-777 Rev B
Wiring Diagram: Standard Option Driver BLU RED PUR GRY + - + - PURPLE (+) DIMMING (0-0V) GRAY (-) Connector for Emergency Input To Switched or Un-switched AC Line Wiring Diagram: HotSpot2 (FHS2) EM- Pass Through (Recommended for non-fulham LED EM) Wiring Diagram: HotSpot2 (FHS2) EM- In Parallel (Recommended for Fulham LED EM) Driver BLU RED PUR GRY Driver BLU RED PUR GRY PURPLE (+) DIMMING (0-0V) GRAY (-) PURPLE (+) DIMMING (0-0V) GRAY (-) + - + - OUTPUT HARNESS FHS-HARNESS-XXX XXX = Value ma Current + - + - CAP OFF RED WIRE OUTPUT HARNESS FHS-HARNESS-XXX XXX = Value ma Current Connector for Emergency Input RED (LED Driver Output +) WHT/BLK (LED Driver Neutral) FHS2 Emergency Driver Connector for Emergency Input RED (LED Driver Output +) WHT/BLK (LED Driver Neutral) FHS2 Emergency Driver To Switched or Un-switched AC Line To Switched or Un-switched AC Line To Un-switched AC Power To Un-switched AC Power Emergency Battery Emergency Battery Test Switch Test Switch ) For reference only, several factors apply. 2) Emergency systems are not UL classified for field installation. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 9 of 4 208-777 Rev B
Wiring Diagram: Constant Power with conduit (FHSCP) EM- Pass Through (Recommended for non-fulham LED EM) Driver BLU RED PUR GRY + - + - PURPLE (+) DIMMING (0-0V) GRAY (-) Connector for Emergency Input Converter Connector FHSCP Emergency LED Driver To Switched or Un-switched AC Line To Un-switched AC Power Test Switch Wiring Diagram: Constant Power with conduit (FHSCP) EM- In Parallel (Recommended for Fulham LED EM) Driver BLU RED PUR GRY PURPLE (+) GRAY (-) DIMMING (0-0V) + - + - Connector for Emergency Input Converter Connector CAP OFF BLUE WIRE FHSCP Emergency LED Driver To Switched or Un-switched AC Line To Un-switched AC Power Test Switch ) For reference only, several factors apply. 2) Emergency systems are not UL classified for field installation. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 0 of 4 208-777 Rev B
Wiring Diagram: Parallel Wiring (FHSCP-UNV-0P-L-SD) GROUND LINE NEUTRAL HOT (20V~277V) BLACK WHITE (COMMON) WALL SWITCH BLACK WHITE DRIVER MUST BE GROUNDED Driver BLU RED PUR GRY RED (+) BLUE (-) 4 3 2 FHSCP-UNV-0P-L-SD Emergency LED Driver 6 5 4 3 2 LED Driver Output (+) LED Driver Output (-) LED (+) LED (-) PGR (+) PGR ( -) TEST SWITCH BATTERY RED (+) + - + - Connector for Emergency Input BLUE (-) ) For reference only, several factors apply. 2) Emergency systems are not UL classified for field installation. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page of 4 208-777 Rev B
Color and Binning Optical Spectrum 0.44 0.43 0.42 0.4 CIE, y 0.40 0.39 0.38 0.37 0.36 0.35 0.34 5000K 4000K 3500K 3000K 2700K 2700K 3000K 3500K 4000K 5000K 0.33 0.32 0.3 0.3 0.3 0.3 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 0.40 0.4 0.42 0.43 0.44 0.45 0.46 0.47 0.48 0.49 7 SCDM Rectangle 3 SCDM Ellipse CIE, x 400 450 500 550 600 650 700 750 800 Wavelength (nm) ) The Color and Binning and Optical Spectrum charts are for reference only. For more detailed info, contact factory. 2) Reference Samsung Chromaticity Diagram for Color and Binning. Binning per ANSI C78.377-205 @ 25 C; 3 SDCM. 3) The Optical Spectrum values vary depending on product type and color rank. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 2 of 4 208-777 Rev B
Guidelines Reduced Flicker Operation Feature DC Engine models have added circuitry to help reduce the Flicker when operated on the 50/60Hz power lines. The Flicker percentage on these models is below 30% when operated at line voltage, per CEC requirement. Termination Notes A luminaire disconnect UL listed connector is included, as part of DC Engine Retrofit Kit to meet Energy Star requirements. Use solid wire size 8AWG/2 per pole, rated at max 600V load and 05 C operating temperature. L Strip wires to -3mm (0.47in.). N Connector not for multiple use. For additional information on Wago's 873 Series Lumi-Nuts connector, please visit: Daisy Chain Environmental Rating DC Engine Retrofit Kit are rated for dry and damp locations. Fastening to Luminaire When installing by mounting thru holes (recommended), use any screw with diameter less than 0.3in. [3.4mm]. Mount on a flat surface and use all 4 mounting holes to ensure good contact between back side of DC Engine Retrofit Kit and mounting surface. Refer to max specified torque for installation. Suggested screw sizes: #5 or M3 Pan Head screw. Electrostatic Sensitive Product (ESD) Fulham LED products should be handled with proper measures to protect against any potential ESD damage. When servicing, personnel should be ground and direct contact with LED should be avoided. Thermal Management Proper thermal management should be employed to ensure life and reliability of product. Wiring Intended for UNV (20-277V) application ONLY. Connect the Black wire from the DC Engine Retrofit Kit to the building Line by using the proper connectors or wire nuts. Connect the White wire from the DC Engine Retrofit Kit to the building/source Neutral by using the proper connectors or wire nuts. DC Engine Retrofit Kit and luminaire must be grounded. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 3 of 4 208-777 Rev B
Part Number Matrix V K M UNV 08 RD 8 40 Product Line Compliance Dimming Input Voltage Estimated Power Shape CRI Color Temperature 7 6 6 V = Vizion K= DC Engine M = 0-0V UNV = 20V~277V 08 = 8W RD=Round 8 = 80 27 = 2700K 6 Retrofit Kit 9 = 90 30 = 3000K 6 (culus Classified) 35 = 3500K 6 40 = 4000K 50 = 5000K 57 = 5700K 6 Standard Product offering, in addition to 90CRI / 3000K. (All other options are made to order with MOQ and lead time). 65 = 6500K 7 DC Engine Retrofit Kit includes mounting hardware, retrofit labels, and installation instructions. 6 A Material A = CEM Product Image: 8W Round DC Engine Retrofit Kit This luminaire has been modified and can no longer operate the originally intended lamp. Ce luminaire a été modifié et ne peut plus utiliser la lampe prévue à l'origine. US0 277V LED LUMINAIRE RETROFIT KIT Ph:(323) 599-500 VKMUNVxxxRxxxxA Input Voltage: 20-277VAC (50/60Hz) Input Current: x.xxa @20VAC Suitable for Dry or Damp Locations E36524 DATE CODE 0 0 0 0 0 0 0 0 0 0 0 0 Hardware Kit: TLC-HW08 UNV DC Engines Retrofit Kits with 0-0V Dimming : Hardware, Quick disconnect, Labels & Installation Instructions Packaging Master Carton OUTER DIMENSION H L W H W L 2.65 (550mm) Net Weight 4.52 lbs. (6.6 kg) 5.75 (400mm) Gross Weight 20.24 lbs. (9.2 kg) 9.45 (240mm) QUANTITY 20pcs. Fulham Co. Inc.: 2705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: -323-779-2980 Fax.: -323-754-9060. Page 4 of 4 208-777 Rev B