SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

Similar documents
SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

PROJ. NO SECTION HYDRONIC PUMPS

SECTION AXIAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS

1. Wiring Diagrams: Power, signal, and control wiring.

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

A. This Section includes natural gas piping, specialties, and accessories within the building.

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

SECTION HVAC POWER VENTILATORS

SECTION FACILITY FUEL OIL PIPING

SECTION ENCLOSED CONTROLLERS

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION METERS AND GAGES FOR HVAC PIPING

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Henderson Engineers, Inc. SECTION GENERAL SERVICE COMPRESSED AIR SYSTEMS PART 1 - GENERAL REQUIREMENTS

A. This Section includes the following domestic water piping specialties:

IN2 Enclosed Switches and Circuit Breakers

University of Houston Master Construction Specifications Insert Project Name

Ice Rink Renovation & New Clubhouse

A. This Section includes the following types of sectional overhead doors:

SECTION METERS AND GAUGES. 0.1 All meters and electronic gauges shall be able to communicate with the current BAS System (Johnson METASYS).

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Doosan XHP1170FCAT Bid Specifications

SECTION AIR TERMINAL UNITS

SOLAR HEATING SYSTEM

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Doosan XHP1170WCAT Bid Specifications

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

University of Delaware

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

MEDIUM-VOLTAGE SWITCHGEAR

A. This Section includes general duty valves common to several HVAC piping systems.

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION VALVES

University of Houston Master Construction Specifications Insert Project Name

SAM-e. Engineering Manual

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ATTACHMENT A PRINCE EDWARD COUNTY INVITATION FOR BIDS # MOBILE DIESEL PACKAGED ENGINE GENERATOR SPECIFICATIONS

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION LIFT ARM PARKING GATES

Wilo IL Vertical Inline Pumps. Engineering Specification

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

UNIVERSITY OF NORTH FLORIDA Arena HVAC Replacement SECTION MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS

BUSWAY Low Voltage (Pow-R-Flex)

Herpteraium SECTION VALVES GENERAL

QRDT. an EnPro Industries company QUINCY QRDT SERIES TWO-STAGE, OIL-LESS RECIPROCATING AIR COMPRESSORS 5-30 HP

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

VERTICAL LIFT FIRE/BLAST DOORS

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SECTION WIRING DEVICES

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

Capital Projects Group General Service Compressed Air System Specification

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

EG Series Screw Air Compressors

SOUND-RETARDANT- VERTICAL LIFT DOORS

SECTION METERS AND GAUGES

Air Handling Unit Construction Checklist

SECTION WELDING FUME EXHAUST SYSTEM

SULLAIR Oil Free Rotary Screw Air Compressors

SECTION VALVES PART 1 -GENERAL

STANDBY EMERGENCY CNG/LPG GENERATOR

East Central College

A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following:

Requirements for Dispensing of Compressed Natural Gas. Yvonne Espinoza, PE Austin Fire Department Engineering Services

SECTION VALVES PART 1 - GENERAL

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR HVAC PIPING Page

Bid Specifications HP935WCU PORTABLE AIR COMPRESSOR

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES

SECTION PANELBOARDS

KKAI Report No Rev 1 Prepared for BioHeatUSA April 28, 2009

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

C. System Design and Performance Requirements

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

A. Valves and specialties including necessary accessories indicated on drawings and specified in this section.

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

Kunkle Models 189/363/389 safety valves Safety and relief products

Transcription:

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-1 SECTION 22 1519 - GENERAL-SERVICE AIR COMPRESSOR 1.1 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following general-service compressed-air equipment and related accessories: 1. Air compressors and receivers. 2. Air-inlet filter, unit mounted. 3. Internal compressed-air dryer. 4. Internal compressed-air filter assemblies. 1.3 DEFINITIONS A. Actual Air: Air delivered from air compressors. Flow rate is delivered compressed air measured in acfm. B. Standard Air: Free air at 68 deg F and 1 atmosphere (29.92 in. Hg) before compression or expansion and measured in scfm. 1.4 SUBMITTALS A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for the following compressed-air equipment: 1. Air compressors, including receivers and intake filters. 2. Compressed-air dryers. 3. Compressed-air filter assemblies. B. Shop Drawings: 1. Wiring Diagrams: Power, signal, and control wiring. C. Product Certificates: Certificates of shop inspection and data report for receiver tanks as required by ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. D. Startup service reports. E. Operation and Maintenance Data: For the following compressed-air equipment and accessories to be include in operation and maintenance manuals: 1. Air compressors. 1.5 QUALITY ASSURANCE A. Installer Qualifications: An authorized representative of compressed-air equipment manufacturer for both installation and maintenance of units required for this Project. B. Product Options: Drawings indicate size, profiles, and dimensional requirements of compressedair equipment and are based on the specific system indicated. Refer to Division 1 Section "Product Requirements."

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-2 C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. D. ASME Compliance: Fabricate and label receiver tanks to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. E. Comply with NFPA 70, "National Electrical Code." 2.1 MANUFACTURERS PART 2 - PRODUCTS A. In other Part 2 articles where titles below introduce lists, the following requirements apply for product selection: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the manufacturers specified. 2.2 PACKAGED AIR COMPRESSORS AND RECEIVERS A. Description: Factory-assembled, -wired, -piped, and -tested; electric-motor-driven; air-cooled; continuous-duty air compressors and receivers that deliver air of quality equal to intake air. B. Control Panels: Automatic control station with load control and protection functions. Comply with NEMA ICS 2 and UL 508. 1. Mounting and Wiring: Factory installed and connected as an integral part of equipment package. 2. Enclosure: NEMA ICS 6, Type 12 control panel, unless otherwise indicated. 3. Instrumentation: Include receiver pressure gage, discharge-air pressure gage, air-filter maintenance indicator, hour meter, Compressor discharge-air and coolant temperature gages. C. Receivers: Steel tank constructed according to ASME Boiler and Pressure Vessel Code: Section VIII, Division 1; rated for working pressure at least as high as highest discharge pressure of connected compressors; and bearing appropriate code symbols. Include safety valve, pressure gage, automatic drain, and pressure-reducing valve. D. Fabricate base and attachment to pressure vessel with reinforcement strong enough to resist packaged equipment movement during a seismic event when base is anchored to building structure. 2.3 AIR COMPRESSOR A. Air Compressors: Simplex unit. 1. Available Manufacturers: a. Ingersoll-Rand Company; Model #UP6-10TAS-125 b. Quincy Compressor. 2. Compressor(s): Single stage, Rotary Screw type with lubricated compression chamber. a. Mounting: Tank mounted b. Number of Compressors: One c. Motor Size: 10 hp, 208 V., 3 phase, 60 Hz. d. Standard-Air Capacity: Min: 38 scfm. e. Discharge Air Pressure: 210 psig

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-3 f. Combined high discharge-air temperature and low lubrication-oil temperature switch, and oil filter. g. Belt drive. h. Single stage units. 3. Receiver: ASME construction steel tank. a. Orientation: Horizontal arrangement. b. Capacity: 80 gal. c. Pressure Rating: 175 psig minimum. 4. Miscellaneous Devices: Safety valves, pressure regulators, and shutoff valves. 2.4 AIR-INLET FILTERS A. Description: Combination inlet filter-silencer, machine mounted, for each air compressor. 1. Construction: Weatherproof housing for replaceable, dry-type filter element, with silencer tubes or other method of sound reduction. 2. Capacity: Match capacity of air compressor, with collection efficiency of 99 percent retention of particles larger than 10 microns. 2.5 ACCESSORIES A. General: Include accessories with working-pressure rating not less than system pressure at location where used, and compatible with equipment and piping system used. 2.6 SPECIALTIES A. Safety Valves: ASME Boiler and Pressure Vessel Code: Section VIII, Division 1, construction; National Board certified, labeled, and factory sealed; constructed of bronze body with poppet safety valve for compressed-air service. 1. Pressure Settings: Higher than discharge pressure and same or lower than receiver pressure rating. B. Automatic Drain Valves: Electrical- or mechanical-operation type with corrosion-resistant metal body and internal parts, rated for 200-psig minimum working pressure, capable of automatic discharge of collected condensate. C. Pressure Regulators: Bronze body, direct acting, spring loaded, manual pressure-setting adjustment, and rated for 250-psig inlet pressure, unless otherwise indicated. 1. Type: Diaphragm or pilot operated. D. Pressure Regulators: Aluminum alloy or plastic body, diaphragm operated, direct acting, spring loaded, manual pressure-setting adjustment, and rated for 250-psig inlet pressure, unless otherwise indicated. E. Compressed-Air Filters: 1. Available Manufacturers: a. Ingersoll-Rand Company; Air Compressor Group. b. Pioneer Air Systems, Inc. c. Ultrafilter Inc. 2. Mechanical-Separation Filters: Two-stage air-line filters of capacity not less than that of connected equipment. Equip with deflector plates; resin-impregnated-ribbon-type filters with edge filtration, 40 micrometers thick; and drain chock.

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-4 3.1 EQUIPMENT INSTALLATION PART 3 - EXECUTION A. Install air compressor where shown. Install units level, plumb, and anchored to substrate in locations indicated. Maintain manufacturers' recommended clearances. Orient equipment so controls and devices are accessible for servicing. B. Vibration Isolation: Mount equipment with motors larger than 5 hp on vibration isolation equipment as recommended by manufacturer. C. Maintain manufacturer's recommended clearances for service and maintenance. D. Install the following devices on compressed-air equipment: 1. Thermometer, Pressure Gage, and Safety Valve: Install on each compressed-air receiver. 2. Pressure Regulators: Install downstream from air compressors, dryers, purification units, and filter assemblies. 3. Automatic Drain Valves: Install on intercoolers, after coolers, receivers, and dryers. Discharge condensate over nearest floor drain. 3.2 CONNECTIONS A. Piping installation requirements are specified in other Division 22 Sections. Drawings indicate general arrangement of piping, fittings, and specialties. B. Install piping adjacent to equipment to allow service and maintenance. C. Connect piping to air compressors and receivers, except safety relief valve connections, with flexible pipe connectors of materials suitable for service. Flexible pipe connectors and their installation are specified in Division 22 Section "General-Service Compressed-Air Piping." D. Ground equipment according to Division 26 Section "Grounding and Bonding." E. Connect wiring according to Division 26 Section "Conductors and Cables." F. Tighten electrical connectors and terminals according to manufacturer's published torquetightening values. If manufacturer's torque values are not indicated, use those specified in UL 486A and UL 486B. 3.3 LABELING AND IDENTIFICATION A. Install identifying labels and devices for compressed-air equipment. Refer to Division 22 Section "Mechanical Identification" for labeling and identification materials. 3.4 STARTUP SERVICE A. Engage a factory-authorized service representative to test, inspect, and adjust components and equipment installation and to perform startup service. B. Perform the following final checks: 1. Verify that specified tests of piping systems are complete. 2. Check for piping connection leaks. 3. Check belt drives for proper tension. 4. Verify that air-compressor inlet filters and piping are clear. 5. Check for equipment vibration-control supports and flexible pipe connectors and verify that equipment is properly attached to substrate.

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-5 6. Check safety valves for correct settings. Ensure that settings are greater than aircompressor discharge pressure but not greater than rating of system components. 7. Test operation of equipment safety controls and devices. 8. Drain receiver tanks. C. Verify that compressed-air equipment is installed and connected according to the Contract Documents. D. Verify that electrical wiring installation complies with manufacturer's submittal and written installation requirements in Division 26 Sections. E. Operational Test: After electrical circuitry has been energized, start units to confirm proper motor rotation and unit operation. F. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment. G. Complete installation and startup checks according to manufacturer's written instructions. H. Prepare written report documenting testing procedures and results. 3.5 DEMONSTRATION A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain general-service compressed-air equipment. Refer to Division 1 Sections. END OF SECTION 22 1519

13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-6 THIS PAGE INTENTIONALLY LEFT BLANK