Project: GKM Block 9 - BFP Location: Mannheim, Germany Year: 2012 HKM111Z04 21215 kw 6.3 kv 1775 rpm 3 pieces Operation with frequency inverter / efficiency 98.1 %
Project: Boxberg Power Plant Block R - BFP Location: Germany Year: 2009 HKM110D04 13500 kw 10 kv 1478 rpm 1 piece Start-up at 75 % of the nominal voltage against full resisting moment of the pump. Best efficiency (>97 %) at 75 % of the nominal power (usual operation point of this application) Copyright: Vattenfall Europe
Project: GKM Block 9 ID-Fan Location: Mannheim, Germany Year: 2012 HKM111Z10 13600 kw 10 kv 592 rpm 2 pieces Fan Power plant design standard: Start-up after voltage drop against open valve and partial voltage 80 % with reduced start-up current. Focus on low noise level.
Project: Wilhelmshaven - BFP Location: Wilhelmshaven, Germany Year: 2012 HKM111Z04 15800 kw 15 kv 1488 rpm 2 pieces 15 kv design
Project: Eemscentraale - MCWP Location: Zwolle, The Netherlands Year: 2011 HKR112Z20 1100 kw 6.6 kv 295 rpm Tube cooled 1 piece start-up current 4.5x
Project: Rotterdam - BFP Location: Rotterdam, The Netherlands Year: 2012 HKM111Z04 15800 kw 15 kv 1488 rpm 2 pieces Power plant design standard: Start-up after voltage drop against open valve and partial voltage 80 % with reduced start-up current. Focus on low noise level.
Project: Moorburg - MCWP Location: Hamburg, Germany Year: 2012 HKM110Z20 2800 kw 10 kv 297 rpm 6 pieces 80 db without tolerance at load / 20 pole design without forced ventilator / mounting form V1
Project: Moorburg ID-Fan Location: Hamburg, Germany Year: 2012 HKM111Z10 11000 kw 10 kv 592 rpm 2 pieces Fan Power plant design standard: Start-up after voltage drop against open valve and partial voltage 80 % with reduced start-up current. Focus on low noise level.
Project: Wai Gao Qiao ID-Fan output extension Location: Shanghai, China Year: 2012 HKM190D08 7600 kw 10 kv 745 rpm 5 pieces Fan The driven fan has a high moment of inertia (7824 kgm2). Max. permissable start-up time 20 seconds at 77 % rated voltage.
Project: Altbach FD-Fan Location: Stuttgart, Germany Year: 2011 HKM180Z99 3100 / 3800 kw 10,5 / 2,5 kv 50 / 60 Hz 993 / 1191 rpm 1 piece Fan Design with 2 windings: Winding 1 = Operation on mains with 10.5 kv & Winding 2 = Operation with frequency inverter with 2.5 kv & 60 Hz
Project: Westfalen Block D&E - BFP Location: Hamm, Germany Year: 2012 HKM110D04 14000 kw 10 kv 1482 rpm 3 pieces Power plant design standard: Start-up after voltage drop against open valve and partial voltage 80 % with reduced start-up current. Focus on low noise level.
Project: GKM Block 9 District Heating s Location: Mannheim, Germany Year: 2012 HCZ545P04 1700 kw 3.3 kv 1495 rpm Water jacket cooled 3 pieces 1700 kw with utilization of F/B during frequency inverter operation while conforming with the max. acceptable frame size 450 mm.
Project: Westfalen Block D&E Oxi Blower Location: Hamm, Germany Year: 2012 HKG550L02 990 kw 10 kv 2990 rpm Rib cooled 3 pieces Fan
Project: Sostanj Block 6 - BFP Location: Sostanj, Slovenia Year: 2012 HKM110D04 15500 kw 10.5 kv 1490 rpm 1 piece Efficienecy at 75 % load = 97.93 % Sound pressure level at no-load = 77.9 db(a) Drive chain length = almost 18 m Run-out after voltage drop against open valve is possible
Project: Walsum Block 10 - BFP Location: Germany Year: 2009 HKM111Z04 15500 kw 15 kv 1490 rpm 2 pieces 15 kv ± 10 % / start-up current 4.4x without tolerance / sound pressure level 82 db(a) at load without tolerance
Project: Oroszlany Location: Hungary Year: 2002 Various HKG 710 / 585 / 250 kw 6 kv 1493 / 1492 / 1490 rpm Rib cooled 2+3+1 s Protection against 100 % humidity
Project: Walsum Block 10 PA-Fan Location: Germany Year: 2009 HKM156E04 2150 kw 10 kv 1487 rpm 1 piece Fan Sound pressure level 80 db(a) without tolerance / start-up current 5.0x without tolerance
Project: Walsum Block 10 ID-Fan Location: Germany Year: 2009 HKM110D08 9100 kw 15 kv 1745 rpm 1 piece Fan 15 kv ± 10 % / startup current 4.3x without tolerance / sound pressure level 82 db(a) at load without tolerance / design with redundant air/water cooler (4x 50%)
Project: Walsum Block 10 FD-Fan Location: Germany Year: 2009 HKM110D08 4500 kw 15 kv 745 rpm 1 piece Fan 15 kv ± 10 % / start-up current 4.9x without tolerance / sound pressure level 82 db(a) at load without tolerance
Project: Walsum Block 10 CEP Location: Germany Year: 2009 HKR171P04 920 kw 10 kv 1486 rpm Tube cooled 2 pieces Start-up current 5.0x without tolerance / sound pressure level 83 db(a) at load without tolerance
Project: Walsum Block 10 Mills Location: Germany Year: 2009 HKM150D06 730 kw 10 kv 984 rpm 4 pieces Mill Start-up torque 200 % / start-up current 5.0x without tolerance
Project: Walsum Block 10 - MCWP Location: Germany Year: 2009 HKR112P14 2800 kw 10 kv 422 rpm Tube cooled 2 pieces Application: Highlight: Start-up current 5.0x without tolerance / sound pressure level 85 db(a) at load without tolerance
Project: Walsum Block 10 Absorber s Location: Germany Year: 2009 HKM163D12 900 kw 10 kv 493 rpm 4 pieces Start-up current 5.0x without tolerance / sound pressure level 75 db(a) at load without tolerance
Project: Voerde Power Plant LV Absorberpumps Location: Germany Year: 2004 HKR190B12 950 kw 0.69 kv 495 rpm Tube cooled 2 pieces Quietness stage R (max. 1.8 mm/sec) Operation with frequency converter
Project: Voerde Power Plant HV Absorberpumps Location: Germany Year: 2004 HKR190B12 900 kw 10 kv 495 rpm Tube cooled 6 pieces Quietness rating R (max. 1.8 mm/sec) / sound pressure at load 77 db(a)
Project: Termoli Power Plant MCWP Location: Italy Year: 2005 HKR110D12 1850 kw 6.6 kv 495 rpm Tube cooled 2 pieces Design with double casing for noise reduction
Project: Termoli Power Plant Location: Italy Year: 2005 HKG550M04 1100 kw 6.6 kv 1493 rpm Rib cooled 2 pieces
Project: Termoli Power Plant BFP Location: Italy Year: 2005 HKM156Z02 2400 kw 3.3 kv 3578 rpm 4 pieces Frequency inverter driven / speed control range 350-3600 rpm / sound pressure level 82 db(a) without tolerance
Project: Simmering - MCWP Location: Vienna, Austria Year: 2008 HKR190P14 900 kw 6.3 kv 423 rpm Tube cooled 2 pieces
Project: Schwedt Power Plant ID-Fan Location: Germany Year: 2006 HKM180D06 5700 kw 6 kv 995 rpm 3 pieces Fan 80 db at load without tolerance
Project: Schwedt Power Plant FD-Fan Location: Germany Year: 2006 HKG556H04 2300 kw 6 kv 1494 rpm Rib cooled 3 pieces Fan Design with sleeve bearings / sound pressure level 80 db (+3 tolerance) at load
Project: Schwarze e Power Plant Location: Germany Year: 2008 HKM163R04 2700 kw 10 kv 1482 rpm 3 pieces Vertical Design (V1), sound pressure level 80 db(a) without tolerance, start-up current 5.5x without positive tolerance
Project: Schwarze e ID-Fan Location: Germany Year: since 1994 HKM110D08 11800 kw 10 kv 743 rpm 2+2 pieces Fan Low start-up current / low noise (80 db)
Project: Rugeley Power Plant - Booster Location: England Year: 2007 HKR111Z08 4950 kw 11 kv 745 rpm Tube cooled 2 pieces Fan Heavy start-up at 80 % UN / design with sleeve bearings
Project: Niederaußem Power Plant ID-Fan Location: Germany Year: 1998 HKM110D08 9350 kw 10 kv 743 rpm 2 pieces Fan Sound pressure level at load: 77 db(a) [without tolerance]
Project: Maritza Power Plant - BFP Location: Bulgaria Year: 2007 HKM171E04 6000 kw 10 kv 1487 rpm 6 pieces 2nd shaft end for oil pump / reduced starting current 5.2x without tolerance
Project: Lippendorf Power Plant - MCWP Location: Lippendorf, Germany Year: 1996 HKL110Z18 3700 kw 10 kv 330 rpm Air / air cooled 4 pieces Biggest manufactured motor in vertical design / low noise: 80 db(a) at load
Project: Lagisza Power Plant Location: Poland Year: 2007 HKM163E04 3650 kw 10.5 kv 1491 rpm Tube cooled 1 piece 82 db(a) at load without tolerance / 2nd shaft end for oil pump
Project: Lagisza Power Plant Location: Poland Year: 2007 HCZ545D04 460 kw 10.5 kv 1494 rpm Water jacket cooled 2 pieces Water jacket cooled design / sound level 80 db(a)
Project: La Robla 2 Power Plant Location: Spain Year: 2007 HKM180E08 5300 kw 6.3 kv 744 rpm 1 piece Fan Reduced starting current 4.7x / start-up at 71 % nominal load
Project: La Robla 2 Power Plant - Absorberpumps Location: Spain Year: 2007 HKG550K06 900 kw 6.3 kv 994 rpm Rib cooled 4 pieces Efficiency > 97 %
Project: Iskenderun Power Plant Location: Turkey Year: 2001 HKG550L10 425 kw 10 kv 596 rpm Rib cooled 10 pieces
Project: Flingern Power Plant Location: Germany Year:2004 HKG545K08 560 kw 5 kv 746 rpm Rib cooled 2 pieces Mounting form B3/B5 / additional load at the flange: 19500 N
Project: Fiddler s Ferry & Ferrybridge - Fan Location: England Year: 2007 HKR111Z08 5200 kw 11 kv 745 rpm Tube cooled 6 pieces Fan Heavy start-up at 80 % UN / design with sleeve bearings
Project: Boxberg Block R ID Fan Location: Boxberg, Germany Year: 2009 HKM111Z10 13500 kw 10 kv 590 rpm 1 piece Fan Reduced starting current 5.0x without tolerance / suitable for start-up at 75 % rated voltage during full resisting moment Weigth: 42 tons Nom. Torque: 218 knm
Project: Boblitz Location: Germany Year: 2004 MKG535K04 380 kw 400 V 47.75 Hz 1425 rpm Rib cooled 3 pieces
Project: BoA 2&3, Neurath Power Plant - MCWP Location: Grevenbroich Germany Year: 2007 HKM110Z18 3500 kw 10 kv 329 rpm 5 pieces Low noise: 80 db(a) at load / start-up current 4.8 (without tolerance)
Project: BoA 2&3, Neurath Power Plant - BFP Location: Grevenbroich, Germany Year: 2007 HKM110D04 13500 kw 10 kv 1478 rpm 4 pieces Reduced starting current 4.8x without tolerance / suitable for start-up at 75 % rated voltage during full resisting moment. Used in the word s most modern twinblock lignite power plant.
Project: BoA2&3, Neurath Power Plant - Absorber Location: Grevenbroich, Germany Year: 2007 HKR110B14 1400 kw 10 kv 424 rpm Tube cooled 13 pieces Design according to power plant standard / noise level 77 db(a) without tolerance at load
Project: Abono2 Power Plant Location: Spain Year: 2005 HKM110D08 8100 kw 6 kv 747 rpm 2 pieces Fan Efficiency 97.9 % / heavy starting duty of an ID-Fan with a moment of inertia of 15357 kgm2