AT COMMUNICATION POWER DISTRIBUTION SYSTEM TECHNICAL GUIDE

Similar documents
twin engine two battery bank split charge system

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Expert Design...Trusted Power

AME. Rectifier - Battery charger. Industrial applications: Key features:

Distributed intelligence

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

MCD 200 Series Soft Starters

ABB central inverters ULTRA-750/1100/ kW to 1560kW

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Diesel generator set QSX15 series engine

Designed for Today s World

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Diesel generator set QSK23 series engine

SESL H - THREE PHASE AC VOLTAGE STABILISERS & REGULATORS. SESL H SERIES - THREE PHASE to 1500 kva. AC THREE PHASE TO 1500 kva

See «Overview of types»

Matson Programmable Voltage Sensitive Relay MA98411

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Coleman Air Diversion Controller Model C160M Version 4.3 With Extended Diversion Mode

Uninterruptible Power System

Industrial Chargers and

Series 230 Automatic Transfer Switch

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2

Function ECU, Wireless

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

Post evolve Series. Installation Manual

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Lithium Power Supply

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

Wheel Torque Transducer WTT-D x

Designed for Today s World

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

RUTLAND HRSi CHARGE REGULATOR

Designed for Today s World

Diesel generator set QSK23 series engine

500 Watt Portable LED Work Area Light Cart ft cord - 60,000 Lumens V AC

Overview of types. Technical data. Safety notes

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Function ECU, Wireless

Post evolve Series. Installation Manual

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

AT EVO SERIES BATTERY CHARGER

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

DEEP SEA ELECTRONICS PLC

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Petrochemical processing Ship Yards Oil Fields Irrigation

Improves fan ef ciency

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set QSL9-G7 series engine

Diesel generator set 6BT5.9 series engine

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Diesel generator set QSX15 series engine

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

PCS AC POWER LINE CONDITIONERS. PCS H SERIES - THREE PHASE - 6 to 500 kva H - THREE PHASE SERVO ELECTRONIC DESIGN. AC - THREE PHASE - 6 TO 500 kva

1967 to s 1967, Kussmaul Engineering is born. In 1975, the first Kussmaul Battery Charger is introduced.

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

JUNCTION BOX FOR CATHODIC PROTECTION

Outdoor vacuum breaker for railway applications - FSK II

Industrial Power Supplies

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Industrial PFC UPS System

Phoenix Multi Inverter/Chargers

Power consumption In operation At rest For wire sizing

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Coleman Air Diversion Controller Model C40

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

Technical data. Safety notes

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

Net +Plus Connection Code

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Manual Installation & Operation

Spark-ignited generator set

ESD5500E Series Speed Control Unit

SCC-MPPT Solar Charge Controller

AXXAIR s orbital cutting

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Diesel generator set QSB7 series engine

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

EVO AT SERIES BATTERY CHARGER

FUSION MINI. Fusion Mini Light Bar Instruction Manual V.1. Model # FN-6116, FN-6116D. Distributed By:

Diesel generator set 4BT3.3 series engine

For reliable control of small, large or multi-system-type lubrication systems

Transcription:

AT COMMUNICATION POWER DISTRIBUTION SYSTEM TECHNICAL GUIDE

CONTENTS 1. INTRODUCTION AND OVERVIEW... 4 1.1 INTRODUCTION... 4 1.2 SYSTEM OVERVIEW... 4 1.3 PDS FEATURES AND CAPABILITY... 4 1.4 SYSTEM CONFIGURATIONS... 5 2. MAIN MODULES... 6 2.1 FILTER UNIT... 6 2.1.1 Filter Unit Function... 6 2.2 POWER SPLITTER UNIT... 7 2.2.1 Power Splitter Function... 7 2.3 LOW POWER UNIT... 7 2.3.1 Lower Power Unit Function... 7 2.4 HIGH POWER UNIT... 8 2.4.1 High Power Unit Function... 8 3. CONFIGURATIONS... 9 3.1 CONFIGURATION 1 FULL SYSTEM WITH BOTH BATTERY MANAGEMENT AND METERING... 9 3.2 CONFIGURATION 2 FULL SYSTEM WITH BATTERY MANAGEMENT WITHOUT METERING... 10 3.3 CONFIGURATION 3 FULL SYSTEM WITHOUT BATTERY MANAGEMENT OR METERING... 11 3.4 CONFIGURATION 4 HIGH POWER ONLY WITH METERING AND BATTERY MANAGEMENT... 12 3.5 CONFIGURATION 5 HIGH POWER ONLY WITHOUT METERING OR BATTERY MANAGEMENT... 13 3.6 CONFIGURATION 6 LOW POWER ONLY WITH METERING AND BATTERY MANAGEMENT... 14 3.7 CONFIGURATION 7 LOW POWER ONLY WITHOUT BATTERY MANAGEMENT OR METERING... 15... 16 4. SPECIFICATIONS... 17 4.1 FILTER UNIT... 17 4.2 POWER SPLITTER UNIT... 17 4.3 LOWER POWER UNIT... 17 4.4 HIGH POWER UNIT... 18 5. OPTIONAL ENHANCEMENTS... 19 5.1 CHARGING ARCHITECTURE (OPTIONAL)... 19 5.2 BATTERY MANAGEMENT (OPTIONAL)... 19 5.3 DISPLAY METER (OPTIONAL)... 20 6. FURTHER INFORMATION... 21 6.1 SYSTEM DOCUMENTATION... 21 6.2 INTELLECTUAL PROPERTY... 21 Systems and Configuration Guide ATSCG-PDS Page 2 of 20

No part of this manual may be copied, transcribed, translated or reproduced in any manner or form whatsoever for commercial purposes, without obtaining prior written permission from; AT ELECTRONIC AND COMMUNICATION INTERNATIONAL LTD (C) Copyright of AT Electronic and Communication International Ltd Systems and Configuration Guide ATSCG-PDS Page 3 of 20

1. INTRODUCTION AND OVERVIEW 1.1 Introduction In-vehicle power supplies have not changed much in architecture but the equipment installed has and, now with modern digital systems that can deliver vastly improved information flow becoming standard, it is necessary to address a potential problem. Modern digital systems require stable and coherent power as they are more susceptible to variations such as spikes and interference than their legacy analogue systems. A solution is required that can deliver a coherent 12 or 24 DC power supply to equipment that is interference free, has maximum availability and resilient enough to supply continuous power in what are often extreme operating conditions. A system is required than can operate with dual or triple battery systems and distribute power in a flexible modular architecture for multiple systems. This will allow crew members to focus on the task at hand rather than worrying about the installed systems. is please to provide the Power Distribution System (PDS) to meet the demand outlined above. 1.2 System Overview The PDS is configured with into four component modules; Filter Unit (FU) Power Splitter Unit (PSU) High Power Unit (HPU) Low Power Unit (LPU). 1.3 PDS Features and Capability PDS can support from 1 to 6 installed equipment systems 3 outputs at high power (35 amps) and 3 outputs at low power (6 amps) Each output is separately fused A power filter unit removes spikes and interference Enclosures are rated to IP 64 for water and particle ingress Interconnection cables are fitted with durable quick release connectors Power terminals can be supplied with threaded or quick release connection points Systems and Configuration Guide ATSCG-PDS Page 4 of 20

1.4 System Configurations High and Low Power System with Battery Management and Metering High and Low Power System with Battery Management without Metering High and Low Power System without Battery Management or Metering High Power only with Metering and Battery Management High Power only without Metering or Battery Management Low Power only with Metering and Battery Management Low Power only without Battery Management or Metering Systems and Configuration Guide ATSCG-PDS Page 5 of 20

2. MAIN MODULES 2.1 Filter Unit 2.1.1 Filter Unit Function Provides filtering for spike and interference suppression Main interface between Vehicle Power Supply and PDS Provides fusing for complete system Standard interconnectivity fitting is threaded but can be fitted with quick release connectors. The feed-through filter has excellent RFI attenuation up to GHz frequency levels. These filters have been used extensively in power supplies and digital telecom systems and provide attenuation of 28dB @ 10 KHz, 42dB @ 100 KHz, 90dB @ 1 MHz and >100 db at frequencies up to 1 GHz. A circuit breaker (commonly used in current military platforms) is installed in the filter unit rated at the maximum required current for the system 150 amps. Systems and Configuration Guide ATSCG-PDS Page 6 of 20

2.2 Power Splitter Unit 2.2.1 Power Splitter Function Splits power to both High and Low Power Units Threaded terminals or quick release connectors (Option) The Splitter unit is used when both High and Low Power Units are required. 2.3 Low Power Unit 2.3.1 Lower Power Unit Function Provides three power outlets of 6 amps each Each outlet separately fused Connection either threaded or quick release terminals Ruggedised heavy duty connectors as standard Systems and Configuration Guide ATSCG-PDS Page 7 of 20

The Low Power Unit is installed when low power systems are installed. The unit is provided with up to three cables for connection between the unit and the installed systems 2.4 High Power Unit 2.4.1 High Power Unit Function Provides three outlets of 35 amps each Each outlet separately fused Connection either threaded or quick release terminals Heavy duty ruggedised connectors standard The High Power Unit is installed when the platform has medium to high power systems requiring stable and interference free power. The unit is provided with up to three cables for connection between the unit and the installed systems, Systems and Configuration Guide ATSCG-PDS Page 8 of 20

3. CONFIGURATIONS 3.1 Configuration 1 Full System with both Battery Management and Metering Systems and Configuration Guide ATSCG-PDS Page 9 of 20

3.2 Configuration 2 Full System with Battery Management without Metering Systems and Configuration Guide ATSCG-PDS Page 10 of 20

3.3 Configuration 3 Full System without Battery Management or Metering Systems and Configuration Guide ATSCG-PDS Page 11 of 20

3.4 Configuration 4 High Power only with Metering and Battery Management Systems and Configuration Guide ATSCG-PDS Page 12 of 20

3.5 Configuration 5 High Power only without Metering or Battery Management Systems and Configuration Guide ATSCG-PDS Page 13 of 20

3.6 Configuration 6 Low Power only with Metering and Battery Management Systems and Configuration Guide ATSCG-PDS Page 14 of 20

3.7 Configuration 7 Low Power only without Battery Management or Metering Systems and Configuration Guide ATSCG-PDS Page 15 of 20

4. SPECIFICATIONS 4.1 Filter Unit Weight Dimensions Temperature Range Connectivity Construction Environmental 3 Kg 225x145x90 mm -30 C to +70 C Connects to Splitter Unit and Low or High Power Units Ruggedised die cast enclosure with heavy duty ruggedised connectors and internal shock proofing. The enclosure is rain shower proof, resistant to condensation and also is resistant to ingress of small particles. Certified to IP 65 (NEMA 4) 4.2 Power Splitter Unit Weight Dimensions Temperature Range Connectivity Functionality Construction Environmental 1.1 Kg 118x90x55 mm -30 C to +70 C Connects Filter Unit to both low and high power units Distributes power to both low and high power units Ruggedised die cast enclosure with heavy duty ruggedised connectors and internal shock proofing. The box is rain shower proof, resistant to condensation and also is resistant to ingress of small particles. Certified to IP 65 (NEMA 4) 4.3 Lower Power Unit Weight Dimensions Temperature Range 1.7 Kg 159x159x102 mm -30 C to +70 C Systems and Configuration Guide ATSCG-PDS Page 16 of 20

Connectivity Functionality Connects to Splitter Unit or Filter Unit Provides three outlets of 6 amps Construction Ruggedised die cast enclosure ruggedised connectors and internal shock proofing Environmental The box is rain shower proof, resistant to condensation and also is resistant to ingress of small particles. Certified to IP 65 (NEMA 4) 4.4 High Power Unit Weight Dimensions Temperature Range Connectivity Functionality Construction 2.1 Kg 159x159x102 mm -30 C to +70 C Connects to Splitter Unit nor Filter Unit Provides three outlets of 35 amps Ruggedised die cast enclosure ruggedised heavy duty connectors and internal shock proofing Environmental The box is rain shower proof, resistant to condensation and also is resistant to ingress of small particles. Certified to IP 65 (NEMA 4) Systems and Configuration Guide ATSCG-PDS Page 17 of 20

5. OPTIONAL ENHANCEMENTS 5.1 Charging Architecture (Optional) The most efficient way of maintaining both sets of batteries is to utilise a split charging system and this can be achieved by either using Voltage Sensing Relays (not recommended) or diodes. The common belief with relay systems is that an alternator charges the engine-start battery first and then, at a pre-set voltage, brings the auxiliary battery into parallel via the relay. Unfortunately, when the voltage energises the relay it pulls both batteries into parallel at the same time. In addition, a high electrical load on the auxiliary battery, e.g. from an inverter, can cause the relay to momentarily disengage, so the battery then continues to discharge, or the relay starts to chatter as it pulls in and out due to the voltage changes. This is often called buzzing, which is arcing taking place between the relay contacts, dramatically affecting the life expectancy of the relay. Moreover, this arcing could well impinge on radio reception quality and there is also mounting evidence to suggest possible EMC implications (RFI) between some VSR's and radio transmissions. Diodes are preferred because; firstly, all battery banks are totally isolated from each other, secondly, the charging process is automatic and thirdly, there is apportioned charging of the batteries which means that all batteries receive a charge commensurate with their needs. The voltage drop across the diode-splitter requires some form of compensation and it is necessary to provide a Battery Management system. In conclusion, solid state devices (diodes) are preferred because of their reliability, they do not generate interference and with suitable battery management will provide a coherent charging regime, even with platforms with multiple batteries and alternators. 5.2 Battery Management (Optional) The Battery Management System is a sophisticated alternator voltage regulator or charge controller which ensures batteries are 95-100% charged with minimum engine running time. An existing alternator charging system is generally optimised for commercial vehicles; however, for specialized platforms, such as all terrain used by aid agencies, emergency services and military, the battery state of charge only ever reaches 65-70% of its capacity with this system, even with the engine running for long periods. These is exacerbated when, during operations the platforms is at rest but not in idle mode and the installed systems are required to be operational. The aim of the Battery Management System is to produce the optimum charging voltage to the batteries, not the alternator, compensating for voltage losses. These voltages are cycled below and above the gassing point of the battery(s) to a given programme, also compensating for changes in ambient temperature, thereby achieving fast and safe charging. The battery management system does not forced feed in terms of charging current - the batteries only take whatever charging current they need. The underlying principle is that batteries should be charged fully, quickly, safely and without damage to batteries and alternator. This is achieved, firstly, by cycling the battery voltages to an established programme ensuring rapid charging without the battery Systems and Configuration Guide ATSCG-PDS Page 18 of 20

actually gassing. Voltages can also be set to suit battery types e.g. Gel, Ni-cads etc and, moreover, the charging voltages will automatically compensate for ambient temperature variations around the batteries, an important consideration. The net result is efficient alternator performance, compensation for voltage losses in the system (including that across blocking-diodes), accompanied by considerably reduced engine running time Battery and alternator life are considerably improved but the main benefit comes from having more available battery capacity at one's disposal, (two to three times as much), without having to install extra batteries and bigger alternators. Diode Pack Battery Management Controller 5.3 Display Meter (Optional) The display of both current and voltage in the system is a necessity not only to provide confidence to the Users but also for fault finding. The meter has an LCD unit with associated switches and shunts. Generally, most installations show charging current to the batteries and available current and voltage at the batteries and at the output. Systems and Configuration Guide ATSCG-PDS Page 19 of 20

6. FURTHER INFORMATION 6.1 System Documentation Documentation will be customised for each system dependant on the exact system configuration. Documentation will include user manual, configuration information, system wiring information, user interface instructions and system testing instructions. 6.2 Intellectual Property All information contained in this manual is the property of; AT ELECTRONIC AND COMMUNICATION INTERNATIONAL LTD The information contained within is subject to change. No part of this manual may be copied, transcribed, translated or reproduced in any manner or form whatsoever for commercial purposes, without obtaining prior written permission. Systems and Configuration Guide ATSCG-PDS Page 20 of 20