SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm

Similar documents
SOLENOID VALVES, SERIES

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

Solenoid Valves JC, JE Series

SOLENOID VALVES JC JE SERIES INSTRUCTION MANUAL

SOLENOID VALVES, SERIES

SOLENOID VALVES 010 SERIES INSTRUCTION MANUAL

SOLENOID VALVES, SERIES

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

SOLENOID VALVES SERIES

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

The first in the world!

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES

The first in the world!

MULTISTAGE MICRO EJECTORS

SOLENOID VALVES SERIES

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

SOLENOID VALVES SERIES

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

SOLENOID VALVES INDEX VALVES GENERAL CATALOG SERIES

SOLENOID VALVES SERIES

BKUA002 Ver.1.0. Vacuum MICRO EJECTOR. INSTRUCTION MANUAL Ver.1.0

MICRO EJECTORS CONTENTS

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

We have achieved Miniaturization and Low Power -port valves for high value-added new generation New Valve for the New Century Thin and compact Valve w

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Micro 3-port Solenoid Valve 005 Series

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

SPEED CONTROLLERS WITH QUICK FITTINGS

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

ACTUATORS GENERAL CATALOG

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

ACTUATORS GENERAL CATALOG

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders

Air Valve AIR-PILOTED VALVES

3 Port Solenoid Valve

Series VP3145/3165/3185

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Pilot Operated 2 Port Solenoid Valve for Dry Air

S Y 3 A F NFZD

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Series ZM Applications

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Series. High-speed valve. K2 Series 2-port valves. K3/K4 series. High-speed response 0.4 to 3.0 ms (ON)

Pilot Operated 2 Port Solenoid Valve for Dry Air

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

SUPPLY JOINTS CONTENTS

MULTI SLIDERS CONTENTS

Angular Style Air Gripper

Series SYJ300/500/700

Series SYA3000/5000/7000

Ecological pneumatic valves.

3 Port Air Operated Valve

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Series SYA3000/5000/7000

Series VP3145/3165/3185

5 Port Solenoid Valve Plug Lead Type

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Seven Features of the Koganei Vacuum Valve

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Transmitters: Relay Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Series DV

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

Series AV2000/3000/4000/5000

SLIDE TABLES CONTENTS

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

HMV/HSV. Manual selector valve. 4-port valve CONTENTS

HN B G1/US B G2/US B G3

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Transcription:

SOLENOID VALVES HEB series (2, 3-port pilot type solenoid valves) SOLENOID VALVES EA, EB SERIES 53mm 10mm 120

HEB SERIES SPECIFICATIONS Specifications Basic Models and Functions Item Basic model Number of positions Number of ports Valve function For direct piping, F type manifold For base piping, A type manifolds Remark: For the optional specifications and order codes, see p.125. HEB10F1 HEB10F2 HEB10F3 HEB10F4 HEB10A1 HEB10A2 HEB10A3 HEB10A4 2 positions 2, 3 ports Single solenoid NC, NO Specifications Item Basic model For direct piping, F type manifold For base piping, A type manifolds Media Operation type Flow rate characteristics Note 1 Effective area SCv mm Sonic conductance C dm 3 /(sbar) 2 Port size Note 2 Lubrication Operating pressure range Proof pressure Response time Note 3 ON/OFF ms Maximum operating frequency Hz MPa {kgf/cm 2 } [psi.] MPa {kgf/cm 2 } [psi.] Standard type Low current type (L) Quick response type (S) Standard type Low current type (L) Quick response type (S) Operating temperature range (atmosphere and media) C [ F] Shock resistance m/s 2 {G} Mounting direction Notes: 1. For details, see the flow rate characteristics on p.122. 2. For details, see the port size on p.122. 3. Values when air pressure is 0.5MPa [73psi.]. HEB10F1 HEB10F2 HEB10F3 HEB10F4 HEB10A1 HEB10A2 HEB10A3 HEB10A4 Air Internal pilot type Base piping (A, AJ type): 0.26 Direct piping (F type): 1.30.07 Not required 0.20.7 {27.1} [29102] 1.05 {10.7} [152] 10/20 or below 10/50 or below 6/7 or below 5 2 550 [41122] 1373.0 {140} (Axial direction 294.2 {30}) Any Solenoid Specifications Item Rated voltage DC12V (Standard type) DC24V (Standard type) DC24V (Low current type) DC24V (Quick response type) Operating voltage range Standard type Current (when rated voltage is applied) Power consumption ma (r.m.s) W Current (when rated Starting ma voltage is applied) Holding ma Power consumption Starting W Holding W Start-up time (standard time) ms Allowable leakage current ma Insulation resistance MΩ Color of LED indicator Surge suppression (as standard) Low current type Quick response type V 200 or below Over 100 (value at DC500V megger) Red Flywheel diode 30 or below 121

Port Size Specification Single unit Manifold Port Direct piping Base piping (with sub-base) F type A type 2(A) 1(P) NPT 3(R) NPT NPT Collected at 3(R) port Flow Rate Characteristics The test method for flow rate characteristics conforms to JIS B 8390:2000 (test method for pneumatic equipment equipment for compressible fluids flow rate characteristics). When used as a single unit Direct piping Base piping (with sub-base) Sonic conductance C Basic model Flow path Critical pressure ratio b dm 3 /(sbar) HEB10F1 HEB10F2 HEB10F3 HEB10F4 HEB10A1 HEB10A2 HEB10A3 HEB10A4 Effective area SCv mm 2 1.300.072 0.750.042 (with fittings) 1.150.064 Note3 1.150.064 Note3 Note1 SOLENOID VALVES EA, EB SERIES When mounted on a manifold F type manifold (direct piping type) A type manifolds (base piping type) Sonic conductance C Basic model Flow path Critical pressure ratio b dm 3 /(sbar) HEB10F1 HEB10F2 HEB10F3 HEB10F4 HEB10A1 HEB10A2 HEB10A3 HEB10A4 Notes: 1. Quick fitting TS3-M3Ms have been mounted on connection ports 1(P), and 2(A). 2. Quick fitting TS3-M3M has been mounted on connection port 2(A). 3. Figures in effective area S are calculated based on sonic conductance C (S=5.0C) Effective area SCv mm 2 1.300.072 0.800.044 (with fitting) 1.300.072 Note3 1.200.067 Note3 Note2 Base piping type (Effective area S = 1.3mm 2 Cv: 0.072) Direct piping type with fittings (Effective area S = 0.75mm 2 Cv: 0.042) MPa 0.7 MPa 0.7 Valve outlet pressure 0.6 0.5 0.4 0.3 Valve outlet pressure 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0 0 20 40 60 80 100 120 140 20 40 60 80 100 Flow rater/min(anr) Flow rater/min(anr) Graphs use flow rate calculations based on the discharge method. Use the flow rate as a guide. 1MPa = 145psi., 1R/min = 0.0353ft. 3 /min. 122

Mass Single Valve Unit Mass Basic model Mass HEB10F1 22 [0.78] HEB10F2 22 [0.78] HEB10F3 22 [0.78] HEB10F4 22 [0.78] HEB10A1 22 [0.78] HEB10A2 22 [0.78] HEB10A3 22 [0.78] HEB10A4 22 [0.78] g [oz.] Additional mass -21 (with bottom mounting base) -25 (with sub-base) Manifold Mass Basic model HEBMF HEBMA Mass calculation of each unit (nnumber of units) (10.5n)15 [(0.37n)0.53] (12.5n)19 [(0.44n)0.67] g [oz.] Block-off plate 2 [0.07] 3 [0.11] Calculation example: HEBM8A stn.18 HEB10A3-PS-D4 (12.58)19(228)295g [10.41oz.] Single unit (direct piping) F type manifold (direct piping type) Normally closed (NC) Normally open (NO) Manifold for 2, 3-port valves HEB10F1 HEB10F3 HEB10F2 HEB10F4 HEBMF Single unit (base piping) A type manifolds (base piping type) Normally closed (NC) Normally open (NO) Manifold for 2, 3-port valves H EB10A1-25 H EB10A3-25 HEB10A2-25 HEB10A4-25 HEBMA 123

Operating Principles and Symbols 2-port Normally closed (NC) Normally open (NO) Solenoid Lip seal HEB10F1 De-energized Column Plunger Flapper Piston Stem Valve body End cover HEB10F2 De-energized Major Parts and Materials Parts Materials Valve Body Stem Lip seal Flapper Mounting base Sub-base Plunger Column End cover Body Aluminum alloy (anodized) Synthetic rubber Mild steel (zinc plated) Aluminum alloy (anodized) Magnetic stainless steel Plastic Aluminum alloy (anodized) Manifold Block-off plate Mild steel (nickel plated) Seal Synthetic rubber SOLENOID VALVES EA, EB SERIES 3-port Normally closed (NC) Normally open (NO) HEB10F3 De-energized HEB10F4 De-energized 124

HEB Series Single Valve Unit Order Codes Mounting base Muffler Wiring specification Without mounting base Without muffler Lead wire 300mm Lead wire 300mm -PS -PL With mounting base With muffler for direct piping Note1 Lead wire 1000mm Lead wire 1000mm Model Valve specification HEB10 Standard type HEB10L Low current type HEB10S Quick response type F1, A1: 2-port normally closed (NC) F2, A2: 2-port normally open (NO) F3, A3: 3-port normally closed (NC) F4, A4: 3-port normally open (NO) -21 Sub-base Without sub-base -75 With muffler for subbase piping Note2 -PS1 Lead wire 3000mm -PL1 Lead wire 3000mm -75 -PS3 -PL3 Without connector ass y Without connector ass y With sub-base Non-locking type -PSN -PLN -25 Locking type Note3 Grommet type Note4 Lead wire 300mm (moisture proof specification) Voltage -D4 DC24V -81 -GL -D5 DC12V Note5 1300mm = 11.8in. 1000mm = 39in. 3000mm = 118in. Model Valve specification Mounting base Sub-base Muffler Wiring specification Voltage Direct piping HEB10 HEB10L HEB10S F1 F2 F3 F4-21 -75 Note1 -PS -PS1 -PS3 -PSN -D4 -PL -81 Note3 -PL1 -PL3 -PLN -GL Note4 -D5 Note5 Base piping HEB10 HEB10L HEB10S A1 A2 A3 A4-25 -PS -PS1 -PS3 -PSN -D4 -PL -75 Note2-81 Note3 -PL1 -PL3 -PLN -GL Note4 -D5 Note5 Notes: 1. The muffler thread for direct piping is M30.5 and the muffler cannot be used for sub-base piping. 2. When ordering the sub-base piping with muffler, always enter both -25 (sub-base) and -75 (muffler). The muffler thread for sub-base piping is M50.8 and the muffler cannot be used for direct piping. 3. The locking-type manual override is not available in the quick response type HEB10S. 125 4. The grommet type is not available in the low current type HEB10L and quick response type HEB10S. 5. The DC12V specification is not available in the low current type HEB10L and quick response type HEB10S.

HEB Series Manifold Order Codes Manual Override Wiring specification Voltage Left side Left side Non-locking type Lead wire 300mm Lead wire 300mm -D4 DC24V -D5 Manifold specification F type (direct piping type) F A type (base piping type) Right side Model HEB10 Standard type HEB10L Low current type HEB10S Quick response type Valve specification Right side F1, A1: 2-port normally closed (NC) F2, A2: 2-port normally open (NO) F3, A3: 3-port normally closed (NC) F4, A4: 3-port normally open (NO) Locking type Note2-81 -PS Lead wire 1000mm -PS1 Lead wire 3000mm -PL Lead wire 1000mm -PL1 Lead wire 3000mm DC12V Note4 SOLENOID VALVES EA, EB SERIES -PS3 -PL3 A Without connector ass y Without connector ass y -PSN -PLN 1300mm = 11.8in. 1000mm = 39in. 3000mm = 118in. Grommet type Note3 Lead wire 300mm (moisture proof specification) -GL Model Number of units Manifold specification Station Model Valve specification Manual override Wiring specification Voltage Manifold model Mounting valve model F type manifold (direct piping type) A, AJ type manifolds (base piping type) HEBM 2 20 F A stn.1 stn. Note1 stn.1 stn. Note1 HEB10 HEB10L HEB10S HEB10 HEB10L HEB10S F1 F2 F3 F4 -PS -PS1 -PS3 -PSN -D4 -PL -81 Note2 -PL1 -PL3 -PLN -GL Note3 HEBBP-F (for block-off plate) A1 A2 A3 A4 -D5 Note4 -PS -PS1 -PS3 -PSN -D4 -PL -81 Note2 -PL1 -PL3 -PLN -GL Note3 -D5 Note4 HEBBP-A (for block-off plate) Notes: 1. The valve mounting location is from the left side of the manifold. 2. The locking-type manual override is not available in the quick response type HEB10S. 3. The grommet type is not available in the low current type HEB10L and quick response type HEB10S. 4. The DC12V specification is not available in the low current type HEB10L and quick response type HEB10S. 126

EB Series Additional Parts Order Codes Block-off plate (block-off plate, gasket, and 2 mounting screws) HEBBP - Specification F : For F type manifold A : For A, AJ type manifold Connector-related EAZ - Connector specification P : Connector, lead wire length 300mm [11.8in.] P1 : Connector, lead wire length 1000mm [39in.] P3 : Connector, lead wire length 3000mm [118in.] PN : Connector, without lead wire (contacts included) Common connector assembly EAZ - Connector specification PA Positive common A type, connector, lead wire length 300mm [11.8in.] PA1 Positive common A type, connector, lead wire length 1000mm [39in.] PA3 Positive common A type, connector, lead wire length 3000mm [118in.] PB Positive common B type, connector, lead wire length 300mm [11.8in.] PB1 Positive common B type, connector, lead wire length 1000mm [39in.] PB3 Positive common B type, connector, lead wire length 3000mm [118in.] PC Positive common C type, connector, lead wire length 300mm [11.8in.] PC1 Positive common C type, connector, lead wire length 1000mm [39in.] PC3 Positive common C type, connector, lead wire length 3000mm [118in.] CPN Positive common, connector, without lead wire (short bar and contacts included) A type: EAZ-PA Black () Red () B type: EAZ-PB Red () (For common wiring) Black () C type: EAZ-PC Red () (For common wiring) Black () Red () Lead wire length Application example 300mm [11.8in.] 11000mm [39in.] 33000mm [118in.] A type B type B type B type B type C type 127

Dimensions of HEB Series Single Valve Unit (mm) 2, 3-port, single solenoid HEB10F1-PL HEB10F2-PL HEB10F3-PL HEB10F4-PL 2, 3-port, single solenoid (with sub-base) HEB10A 1-25-PL HEB10A 2-25-PL HEB10A 3-25-PL HEB10A 4-25-PL Plug For F1,F2 For -75 2-2.1 (Mounting hole) 53SF: 53.7 LED indicator 2-2.1 Counterbore 3.2 Depth 1 (Mounting hole) SOLENOID VALVES EA, EB SERIES LED indicator For -75 53SA: 53.7 2-3.1 (Mounting hole) For -75 Options Mounting base: -21 Locking type manual override: -81 Grommet: -GL : -PS LED indicator LED indicator 2-3.5 (Mounting hole) (Overall length of valve) (Overall length of valve) Model Code HEB10F1HEB10F4, HEB10A1HEB10A4 HEB10LF1HEB10LF4, HEB10LA1HEB10LA4 HEB10SF1HEB10SF4, HEB10SA1HEB10SA4 Remark Overall length to the end of the valve mm 128

Dimensions of HEB Series Manifold (mm) For 2, 3-port HEBMF (Direct piping type) 2-Rc1/8 (both sides) (both sides) Installation example HEBM4F stn.1 HEB10F1-PL-D4 stn.2 HEB10F3-PL-D4 stn.3 HEB10F4-PL-D4 stn.4 HEBBP-F 53SF: 53.7 10.2 (Pitch) stn.1 stn.2 stn.3 stn.4 LED indicator 2-3.3 (Mounting hole) Unit dimensions Number of units HEBMA (Base piping type) 4-NPT1/8 (both sides) Installation example HEBM4A stn.1 HEB10A1-PL-D4 stn.2 HEB10A3-PL-D4 stn.3 HEB10A4-PL-D4 stn.4 HEBBP-A 56.6SA57.3 53SA53.7 10.2 (Pitch) stn.1 stn.2 stn.3 stn.4 LED indicator 2-3.3 (Mounting hole) (per each station) Unit dimensions Number of units 129

Handling Instructions and Precautions Internal circuit Solenoid DC12V, DC24V (Standard type) Solenoid with LED indicator and surge suppression Lead wire Red Lead wire Black Red DC24V (Low current, quick response types) Solenoid with LED indicator and surge suppression Plug connector Attaching and removing plug connector Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. Protruded section Pin Housing Lever Connector assembly Lead wire Red Lead wire Black Red Timer circuit Indication of polarity (DC) Connector Contact Cautions: 1. Do not apply megger between the pins. 2. Leakage current inside the circuit could result in failure of the solenoid valve to return to the rest position or other erratic operation. Always use it at less than the allowable leakage current shown in the solenoid specifications on p.109 and 121. If circuit conditions, etc. cause the leakage current to exceed the maximum allowable leakage current, consult us. 3. For the double solenoid configuration, avoid energizing both solenoids simultaneously. 4. The standard housing type is colored blue, while the low current type is light blue, and the quick response type is white. 5. The low current and quick response types will not activate when the power supply voltage is raised too slowly. Always apply the appropriate voltage. Crimping of connecting lead wire and contact To crimp lead wires into contacts, strip off 4mm [0.16in.] of the insulation from the end of the lead wire, insert it into the contact, and crimp it. Be sure at this time to avoid catching the insulation on the exposed wire crimping section. Contact Hook Insulation crimp tab Exposed wire crimping section Exposed wire 4mm [0.16in.] Lead wire Equivalent to Insulation (Maximum outer diameter:) The low current and quick response types use a timer circuit, as shown above, that achieves power savings by switching to the holding operations mode after a certain period of time and operates at about 1/3 of the starting power consumption. Solenoid valves Power consumption Operating principles of low current and quick response types Power waveform for low current type Reduced power consumption Cautions: 1. Do not pull hard on the lead wire. 2. Always use a dedicated tool for crimping of connecting lead wire and contact. Contact: Model 702062-2M Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1-702062 Manufactured by Sumiko Tech, Inc. Attaching and removing contact and connector Insert the contact with lead wire into a plug connector hole until the contact hook latches on and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Start-up time Power waveform for quick response type Solenoid valves Power consumption Start-up time Reduced power consumption Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. 105

Manifold Non-locking type To operate the manual override, press it all the way down. For the single solenoid, the valve works the same as when in the energized state as long as the manual override is pushed down, and returns to the rest position upon release. For the double solenoid, pressing the manual override on the 14 (SA) side switches the 14 (SA) to the energized state, and the unit remains in that state even after the manual override is released. To return it to the rest position, operate the manual override on the 12 (SB) side. This is the same for the solenoid 12 (SB). Mounting valves on manifold When mounting valves on manifold, the recommended tightening torque for the valve mounting screw is 14.7Ncm {1.5kgfcm} [1.3lbf in.]. Tube 1.Attaching and removing tubes For tube connection, insert an appropriate size tube until it makes contact with the tube stopper, and lightly pull it to check the connection. For tube removal, push the tube against the tube stopper, then push the release ring and at the same time pull the tube out. 2.Either a nylon or urethane tube can be used. Use tubes with an outer diameter tolerance within 0.1mm [0.004in.] of the nominal diameter, and ensure the ovalness (difference between the large diameter and small diameter) is 0.2mm [0.008in.] or less. (Using a Koganei tube is recommended.) SOLENOID VALVES EA, EB SERIES Locking type To lock the manual override, use a small screwdriver to push down on the manual override all the way down and turn it clockwise 45 degrees. When locked, turning the manual override 45 degrees in the counterclockwise direction returns it to its original position, and releases the lock. (Excluding the quick response type) Cautions: 1. Do not use extra-soft tubes since their pull-out strength is significantly reduced. 2. Only use tubes without scratches on their outer surfaces. If a scratch occurs during repeated use, cut off the scratched section. 3. Do not bend the tube excessively near the fittings.the minimum bending radius is as shown in the table below. 4. When attaching or removing tubes, always stop the air supply. In addition, always confirm that air has been completely exhausted from the manifold. Tube size mm [in.] Minimum bending radius Nylon tube Urethane tube 17 [0.28] 20 [0.79] 10 [0.39] 30 [1.18] 15 [0.59] 50 [1.97] 20 [0.79] Cautions: 1. The HEB series valves are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without air supplied from the 1(P) port. 2. Always release the lock of the locking type manual override before commencing normal operation. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could result in damage to the manual override. 106