Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Similar documents
CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

USER S MANUAL SOLAR POWER INVERTER KW-6KW

PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS

230VAC Power Inverter 400W Owner s Manual

User Manual Rittal PMC UPS 6kVA

Uninterruptible Power System

Pure Sine Wave Inverter 600W-24V User Manual

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual 1KVA-5KVA INVERTER / CHARGER

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Application. Battery. Public Grid GS HYBRID INVERTER

Power Inverter 400 MW Owner s Manual

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

Pure Sine Wave Inverter USER MANUAL

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

Operating manual UPS - System

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

MEANWELL DC/AC POWER INVERTERS

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

SAFETY WARNINGS AND GUIDELINES

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

AC CONVERTER / BATTERY CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Solar Hybrid Inverter SP Brilliant Series

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Pure Sine Wave Inverter Charger

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

General Precautions. Personnel Precautions

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

Battery Power Inverters

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Solar Hybrid Inverter SP Efecto Series

1RECHARGEABLE APPLIANCES

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

Lithium Power Supply

Phoenix Inverter

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

USER MANUAL MPS 1-5KW SERIES

The Power of Reliability INSTRUCTION MANUAL

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

SCC-MPPT Solar Charge Controller

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

Uninterruptible Power System

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

MERU Solar Off-Grid Inverters

c-go 24V/6A 24V/8A 24V/12A

Low Frequency Inverter. User Manual

Table of Contents 文管中心 發行章

Solar Hybrid Inverter SP Efecto Series

User Manual 1KVA-5KVA INVERTER / CHARGER

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Solar inverter AX-series

Compact Sine Inverter

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

3000W POWER INVERTER. User Manual

Renewable Solar Inverter, RSI

S150,S300 Series Pure Sine Wave Inverter User s Manual

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

SCC-MPPT Solar Charge Controller

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Solar Charge Controller

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

User Manual / Manuel utilisateur

HPP1 MK6-15A/20A R00 Owners Manual

Mass Combi Ultra 24/ (230 V)

Cruising Charger Series OWNER S MANUAL

Uninterruptible Power System

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

Solar off-grid Inverter. SP Junior Series. User Manual

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

SBC / 2140 / Stage Battery Charger User Manual

SCC-MPPT Solar Charge Controller

User Manual WT Combi-S Pure Sinus Wave Inverter

EPS/ELA-Series User Manual EPS/ELA 250W

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

CX-SERIES ADVANCED BATTERY CHARGER

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

PRO-WAVE INVERTER 12 VOLT, PURE SINE WAVE. P/No.s PW150, PW350, PW600, PW900 & PW1800

General safety and installation information.

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Solar Inverter 3kW-8kW Inverter (off-grid)

Transcription:

IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc last Update 28.8.2018 1

Table of Contents Product description... 3 Applications... 3 Data... 3 Standardization... 3 Special features... 4 DSC (Dynamic Surge Control)... 4 DSC Classes... 4 Protection of deep discharge oft he battery... 4 Performance... 4 Warning... 5 Supplied content... 5 Informations... 6 Front view... 6 US160 / US80... 6 US40... 6 Rear view... 7 US160... 7 US80... 7 US40... 7 Installations... 8 Recommended cable cross section... 8 Recommended battery capacity... 8 External fuse... 8 Installation Steps... 9 Wiring... 9 Grounding... 10 Connecting the consumer device... 10 Connectors for device... 10 Commissioning the unit... 10 Connect the remote control... 10 Switching on the appliance... 10 Activating / deactivating standby... 10 Status Display... 11 Status... 11 Operating Modes... 11 Error display... 11 Troubleshooting... 11 Power display... 12 Assembly... 13 Housing dimensions... 13 Attaching the mounting feet... 16 Fitting... 17 Please note... 18 Specifications... 18 Technical specifications... 18 Accessoires... 18 Instructions for the electrical supply... 21 2

Product description The new IBS Ultra Sine inverters for island operation in mobile or stationary applications produce pure sine wave alternating voltage with 230VAC / 50Hz from 12V or 24VDC battery voltage. Latest technology allows the construction of lightweight and compact inverters. High-frequency hi-tech transformers with a powerful software-controlled IGBT transistor bridge guarantee impressive performance. The latest generation has reduced its own consumption by 30% to 1.2A @ 12.3V / 1.1A @ 24.6V, which is ideal for use in insulated solar systems. Consumers such as hairdryers, vacuum cleaners, coffee machines, hand-held machines, computers, laser printers, measuring instruments, medical devices can be operated in most cases. Applications Motorhomes, Camper 4WDs / Expedition / Rallye Yachting Solar (island installations) Commercial and industrial use Energy back-up for computers, communications and medicine Mobile power for craftsmen Data Technologie Remote Control RP03 Monitoring Housing Cooling High frequency Dual processor Galvanic separation Available as an option Over- / Undervoltage Overtemperature, overload Short circuit, current limiter Reverse polarity / fuse Dynamic Surge Control (DSC) Aluminum, IP40 Cooling plates / cooling tunnel, fan, µc monitored Standardization Low Voltage Directive EMV guideline RoHS guideline 2006/95/EC -EN60950:2005 2004/108/EC -EN 61000-6-3:2006 -EN 61000-6-1:2005 2002/95/EC 3

Special features DSC (Dynamic Surge Control) The inverter is equipped with dynamic surge control. The more battery capacity or charging current support (alternator) is available, the larger consumer devices can be started. If the starting current exceeds the safe value, it results in a safety cut-off (red error LED flashes), reset by switching the inverter off and on again. DSC Classes Inverter type US160 US80 US40 Classe Input voltage Ue due at load Time allowed Power output S1 >13.5V/ >27.0V 2.7 V 800 ms 3.8 kw 1.9 kw 1.0 kw S2 13.0-13.5V/26-27V 2.0 V 400 ms 3.5 kw 1.7 kw 0.8 kw S3 12.3-13.0V/24.6V-26V 1.5 V 200 ms 3.2 kw 1.6 kw 0.7 kw S4 <12.3V/24.6V 1.2 V 100 ms 3.0 kw 1.5 kw 0.6 kw Protection of deep discharge of the battery The inverter is equipped with an intelligent, current-dependent deep-discharge circuit. Switch-off value 11.8V / 23.6V, re-activation 12.3V / 24.6V. Immediate shutdown when battery drops below 10.5V / 21.0V. Performance The IBS inverters are very powerful, as long as the batteries provide the necessary energy. Use as much charged, high-performance batteries as possible. Recommended battery capacities see P. 8. If the inverter is used for a long period, allow the engine to run for support (continuous currents up to 150A and starting currents up to 350A / 180A are possible). If charging support is provided by alternator or solar / charger (U> 13.0V /> 27V), the starting power according to DSC class S1 is available. Abb. 1 Chart peak power 4

Warning Have the wiring carried out by a qualified technician. Before the Connection is started, make sure that all cables and connections are voltage-free. Short circuits and polarity reversal can lead to serious damage to the battery, the Ultra Sine inverter and the electrical installation. Fuses cannot prevent damage caused by polarity reversal. Such damages are not included in the warranty. Inverter output cannot be connected to the public network! (Use US-TS for automatic landline / inverter switching) Never insert objects through the openings and ventilation slots of the device! US160/80/40 Mounting feet Supplied content 5

Informations Front view US160 / US80 Abb. 2 Front view US160/80 US40 Abb. 3 Front view US40 6

Rear view US160 Abb. 4 US160 Rear view US80 Abb. 5 US80 Rear view US40 Abb. 6 US40 Rear view 7

Installations Recommended cable cross section When using a thinner cable cross-section than recommended, large losses and dangerous heating can occur in the connection cable. This may cause the Ultra Sine inverter to fail its full performance. Model US40 US80 US160 Voltage value 12V 24V 12V 24V 12V 24V Min. cable cross section 16 mm 2 10 mm 2 25mm 2 16mm 2 50mm 2 35mm 2 Connection to the device M6 M6 M8 Data refer to the copper cross-section of the cables! Recommended battery capacity High loads caused by an inverter system need sufficient available battery capacity. To ensure that the required application has enough energy, refer to the following table for recommended battery capacities. Load Capacity of 12V System Capacity of 24V System < 500 W 60 Ah 2 x 30 Ah > 500 W 80 Ah 2 x 40 Ah > 1000 W 100 Ah 2 x 50 Ah > 1500 W 140 Ah 2 x 70 Ah External fuse The value fort he external fuse can be found in the following table. Model Battery voltage Fuse to use US40 12 V 40A 24 V 20A US80 12 V 80A 24 V 40A US160 12 V 150A 24 V 80A 8

Installation Steps Wiring Abb. 7 Cabling normal use In mobile applications such as travel trailers or yachts with a possible landline, the two-230v networks (inverter and landline connection) may only be connected via the US-TS FI switch! The same applies if 230V emergency generators are used! For parallel IBS operation, use the US-TS FI transfer switch. Abb. 8 Cabling with US transferswitch Warning: Ensure correct polarity! Closing the circuit can cause a spark! Never connect the AC output of the inverter to the public network! Caution: When installing the USTS FI, please consult the manual for instructions and safety instructions! A main switch (S1) must be provided to allow emergency disconnection of incoming shore power supply! 9

Grounding The grounding scheme of the US Inverter G4 is as follows: Connecting the consumer device Connectors for device The Ultra Sine inverter is equipped with a socket according to IEC 60320-1 C13. A plug according to IEC 60320-1 C14 must be used as a counterpart. Commissioning the unit Connect the remote control Plug the connection cable of the remote control into the remote control plug. A non-crossed 8-pin RG45 cable must be used. Switching on the appliance To switch the device on and off, press the on / off button on the front of the device or the button on the RP03 remote control. Activating / deactivating standby To activate or deactivate standby, press the on / off button on the front of the device or the button on the remote RP03 remote for 3 seconds until the middle LED (orange) lights up (continuous operation active) or extinguishes (standby active). 10

Status Display The three LEDs on the front of the unit or the RP03 connected to the remote control, indicate the status, operating modes, and faults. Status The green LED indicates the current operating state. Statut Green LED Description 1 Switched off 2 Operational 3 In standby The yellow LED indicates the operating mode. Operating Modes Mode Yellow LED Description 1 Standby-mode 2 Continuous operation mode The red LED indicates faults. Error display Error Red LED Description 0 Without Error 1 Over- / Under voltage 2 Over temperature 3 System fault / fuse defective / overcurrent 4 Short circuit / overload Troubleshooting Error Triggered by Resetting by Delayed: 1 Voltage lower than 11.8V / 23.6V Or higher than 15.5V / 31.0V Immediately: Voltage lower than 10.5 V / 21.0 V Voltage higher than 13.1V / 26.2V or lower than 14.5 V / 29.0 V Voltage higher than 13.1V / 26.2V 2 If the temperature is too high at the heat sink. f the heat sink is below a minimum 3 4 If too much current or a faulty fuse has been detected. Short circuit at output or too long load with high power. temperature. Check the load, the polarity and switch the inverter off and then on again. If the fuse is defective, contact IBS. Check the load and switch the inverter off and then on again. 11

Power display The US80 and US160 have an output power indicator. The number of luminous LEDs indicates the current output power. Abb. 9 Power display US160 (left) and US80 (right) 12

Assembly Housing dimensions Abb. 10 US160 Housing dimensions 13

Abb. 11 US80 Housing dimensions 14

Abb. 12 US40 Housing dimensions 15

Attaching the mounting feet Abb. 13 Horizontal alignment of mounting feet Abb. 14 Vertical alignment of mounting feet Screw the mounting feet to the intended positions using the screws supplied. Only the included screws may be used. The tightening torque is 1.1 Nm. 16

Fitting Mount the unit with the mounting feet on a surface. Mounting is possible on a surface, on a sidewall or upside down. The ventilation slots and the fan must not be obstructed, so that the warm air, which is generated during operation, can escape unimpeded. Do not install in a small enclosed space, ensure air circulation. Ensure that no objects, dust or dirt can enter the interior of the unit through the ventilation slots or fan. Avoid any contact with water, moisture or rain. Humidity: 0-95%, non-condensing. 17

Please note In order to guarantee the perfect operation of your IBS Ultra Sine inverter, please note the following points: 1. Inverter and battery voltage must be the same. Operation of a 12V device at 24V leads to destruction of the inverter. 2. The battery must be charged. If an inverter is operated with high power, the battery can be discharged quickly. If the battery voltage is too low, the inverter switches off and can only be switched on again after charging the battery. 3. High continuous load in case of insufficient cooling can lead to an emergency shutdown. The fan supports cooling depending on current and temperature. 4. Observe the same safety regulations as when using the 230V public network. When using the inverters, an additional fuse of 150A (12V) / 80A (24V) is recommended directly at the battery connection or circuit breaker (automatic fuse). Specifications Technical specifications US40 US80 US160 12V 24V 12V 24V 12V 24V Input voltage 10.5V 21.0V 10.5V 21.0V 10.5V 21.0V 15.5V 31.0V 15.5V 31.0V 15.5V 31.0V Rated capacity 400 W 800 W 1600 W Short-term performance 1000 W 2200 W 4500 W Output voltage 230V / 50Hz Print quality IPC3 Temperature range - 20 C bis + 40 C Standby consumption <0.5 W Standby void detection > 15 W 30 W > 15 W 30 W > 15 W 30 W Weight 1.7 kg 3.6 kg 5.5 kg Efficiency 90 / 93 % 90 / 93 % 90 / 93 % Accessoires RP03 US-TS Remote Control Transferswitch for automatic landline / US switching 18

Notes 19

20

Instructions for the electrical supply When connecting a) Before connecting the caravan system to the electrical power supply, check that: 1) the power supply, which is available at the power supply at the caravan site, for the electrical installation and the equipment of the caravan, is suitable for voltage, frequency and current rating; 2) the cables / lines and the connections are suitable, and 3) the main switch of the caravan is in the off position. b) Check the cables / wires, plugs and connections for damage. c) Plug the plug of the flexible cable into the electrical socket provided on the power supply at the caravan site. d) Turn on the main switch on the caravan. e) Check the function of the residual current device (RCDs [FI]) installed in the caravan by pressing the test buttons and switch it on again. Remark 1: The flexible supply line of the caravan should be completely unwound to avoid damage caused by overheating. Remark 2: In case of doubt, or if the supply is not available or is faulty after the above-mentioned procedure has been carried out, contact the caravan site operator. When terminating the connection Turn off the car's main switch and remove the cable. First at the power supply at the caravan site and then, if available, at the caravan port. Recurring test The electrical system of the caravan should preferably be inspected no less than every three years, and if the caravan is frequently used, annually by a competent electrician who should write a report on the condition. 21

22

23

Abb. 1 Chart peak power 4 Abb. 2 Front view US160/80 6 Abb. 3 Front view US40 6 Abb. 4 US160 Rear view 7 Abb. 5 US80 Rear view 7 Abb. 6 US40 Rear view 7 Abb. 7 Cabling normal use 9 Abb. 8 Cabling with US transferswitch 9 Abb. 9 Power display US160 (left) and US80 (right) 12 Abb. 10 US160 Housing dimensions 13 Abb. 11 US80 Housing dimensions 14 Abb. 12 US40 Housing dimensions 15 Abb. 13 Horizontal alignment of mounting feet 16 Abb. 14 Vertical alignment of mounting feet 16 24