Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Similar documents
Automatic Sensor Tap Installation Manual

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Optima ETF-600/ETF-610

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Installation For Service Only

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Milano AUTOMATIC FAUCET

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Dolphin Blue Infrared Taps

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Installation Instructions

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

BASYS Infrared Sensor Activated

ETF-600 Sensor Operated Lavatory Faucet

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

IRC urinal flush control valve

8791T-C02( ) 8791T-C04(AC) 8791T-C04( ) size alkaline batteries(8791t-c02) 2 7 (AAA 2)(8791T-C02) 220V AC 50/60Hz(8791T-C04)

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

MAC FAUCETS FA400 WALL MOUNT FAUCETS

BC632 / BCL632 BC635 / BC635

BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

MAC FAUCETS. FA400 Wall Mount Sensor

DOLPHIN INFRARED TAP DB800 / DB825 TECHNICAL HELPLINE DOLPHINSOLUTIONS.CO.UK DIAMETER PROJECTION TO SPOUT

MAC FAUCETS. FA400 Autoluxe Faucets

A wave does it! Zenith Touch-Free Washroom Technology

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

PRO series programmer

G2 Optima Plus Flushometer

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

PNEUMATIC PUMP Series

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Catalytic Failures. Engine running too hot.

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide

Complete Home Water Protection

The ECLIPSE #9800 & The ECLIPSE #9800WC

STRUKTURA T01-A INSTALLATION INSTRUCTIONS

User s Manual. Automatic Switch-Mode Battery Charger

IRC Urinal Flush Control Valve

Zip FlushMaster Surface mounted sensor

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

LIGATURE RESISTANT SENSOR FAUCET

Owner's Manual. Remote Security and Convenience System INS0866 8/98

Installation Instructions and User Guide

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

SHOWER TIMER INSTALLATION INSTRUCTIONS Battery model 500

Vibration / Audio & LED. Sensitivity Control

Installation Instructions

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

KIA CRT Common Rail Injector Tester User s Manual. Delphi A2 U2 Engine. PIEZO, S & R Engine

Read the instructions carefully before using the pinbrazing unit. Check that all parts are received.

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

Seat Cushion Front. Driver Power Front Seat Cushion. Item Part Number Description Cushion trim cover

EMF INSTALLATION & OWNER S MANUAL ULTRA COMPACT NICHE LIGHT FOR FIBREGLASS POOLS STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

Single Handle Faucet, 4 Plate, Ceramic Cartridge, Extended Lever Handle with Pop-Up

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

HYUNDAI CIT Common Rail Injector Tester User s Manual. A, U, D, J, S, R Engine & U-II, A-II Digital Controller

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Flight Systems. Replacement for KASSEC DESCRIPTION

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

mm (16.1" 3.74" 3.86" ) Soap Tank Capacity 750ml Battery. 750ml AA (1.5V) 4

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

PANcharge1k Battery Charger User's Manual

DIY Bi-Metallic Strip

Installation Instructions

High-speed detection even a little liquid leak

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

WC FLUsHiNG. WC Flushvalves offer an average of 30% water saving...

AquaSense TM ZEG Series

e-ask electronic Access Security Keyless-entry

Wiper Switch. For one Exalto H.D. wiper. Cat. no Quality Marine Equipment

elita CT-700 inside USER MANUAL AlkaViva s proprietary patent-

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Troubleshooting Guide

Installation Instructions

Transcription:

Automatic Sensor Faucet Installation Manual CAT 673031 ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT Revision 7 PAGE 1

Product Description No-Touch automatic faucets and accessories Systems Electronic infrared sensor with technology accurate activation Employs the latest in plug and play digital electronics, solid brass solenoid valve. The faucet is simple and robust with its traditional design The automatic no-touch infrared sensor eliminates cross-contamination. 70% Water Savings Extensive testing shows a significant decrease in average water usage and cost Best Performance Level Suitable for many locations including hotels, educational establishments, hospitals and doctor surgeries, airports, utility washrooms, public conveniences and semi-industrial locations, the Classic faucet is very reliable - and very effective. Features Construction Single-hole Mounting Solid Brass Sensor type : Active Electronic infrared Sensor Power:DC6V(four 5#-alkaline Battery) Battery life expectancy: 150,000 cycles Solenoid valve: 6 Volt magnet latching Working Water Pressure: 0.07Mpa -0.7 Mpa Supply Inlet Size: 1/2 Male Water Temperature Control: Optional Sensing Range: 5cm to 15cm Adjustable Response Time: 0.3 Second Shut-Off Delay Time: 2 Seconds Maximum Running Time:30-60 Seconds Operating Temperature: 1 C to 60 C Operations 1) Invisible light rays are continually emitted from the faucet sensor. 2) When the user s hands come into range of the sensor s detection zone, the valve is activated. 3) After the user removes their hands, the valve closes. The circuit automatically resets for the next user. 4) If an object is in view continuously for sixty seconds, the faucet will automatically shut off. The faucet will remain off until the object is removed. After the object is removed, the faucet functions normally. PAGE 2

Precautions before installation: The automatic sensor faucet BD-8303 should be installed above the washbasin no less than 25cm. Not applicable to stainless steel wash basin or other wash basin which can reflect strong light. If this can t be avoided, then the distance and the angle between the faucet and basin must be carefully adjusted to avoid disturbance from the reflection. Installation shall be in accordance with AS/NZS3500 series of Standards Installation 1. Leave a hole of G1/2 in diameter, 25mm inner thread depth in the wall, as in picture 1: 2. Rest the thread end of the faucet with thread sealing tap into the G1/2 thread hole, use a spanner to fix it to avoid leakage of water, as in picture 2 3. Open the cap of the faucet anti-clockwise with hand, as in picture 3 PAGE 3

4. Take out the battery housing and install batteries(4pcs AA alkaline batteries) Please note: put the sensor back into faucet immediately after installing battery holder; when LED light does not flash, please remove sensor and plug in solenoid valve, to accurately adjust the sensing distance. 5. Connect the solenoid valve and the sensor. The faucet is now ready for use. PLEASE NOTE Once faucet has been installed, please stick one of the coloured dots provided on to the head of the faucet to allow the user to identify if water will flow cold or hot. RED DOT HOT WATER BLUE DOT COLD WATER PAGE 4

Adjustment of the sensing range: THE UNIT IS AUTO ADJUSTING FOR LOCAL CONDITIONS ONCE BATTERIES ARE IN- STALLED HOLD THE SENSOR / BATTERY PACK IN THE POSITION IT WOULD NORMALLY BE SITUATED AND CONNECT THE BATTERY TERMINALS THE UNIT WILL FLASH WHILE IT IS PROGRAMMING TO THE AVAILABLE SENSING RANGE AFTER AROUND 20 SECONDS THE UNIT IS READY FOR NORMAL OPPERATION PAGE 5

ITEM PART# DESCRIPTION MATERIAL ITEM PART# DESCRIPTION MATERIAL 1. 673-033C Spout Adapter SUS 304 S/Steel 13. 673-040 Iron Core 430 S/Steel 2. 673-033B Rubber Mat NBR Rubber 14. 673-039 Spring SUS 304 S/Steel 3. 673-033 Aerator POM Plastic 15. 673-038 Solenoid Valve Plastic, Rubber, WMKA21177 4. 673-033A Spout Shell SUS 304 Stainless 16. 673-045 Screw SUS 304 S/Steel 5. 673-035 O-Ring NBR Rubber 17. 673-042 Cover SUS 304 S/Steel metal 6. 673-036 Flow Adjustment Brass CW602N 18. 673-030 Faucet Body SUS 304 S/Steel 7. 673-037 Housing Brass CW602N 19. 673-043B Battery Box Hardware Electronic 8. 673-041 Diaphragm POM Plastic + Rubber 20. 673-043A Sensor Electronic Hardware 9 679-041A Diaphragm Skel- POM Plastic 21. 673-044 Faucet cover SUS 304 S/Steel eton 10 679-041B Spring needle SUS 304 S/Steel 22. 673-036a Seal NBR Rubber 11 679-041C Diaphragm POM plastic + 23. 673-036b Seal NBR rubber Rubber 12. 679-041D Glue Silicone Rubber 24. 673-043 Battery box / Sensor Electronic Hardware PAGE 6

Troubleshooting Guide: Before checking for fault, please make sure the installation distance correct (refer to precautions before installation as above ). If distance is incorrect, faucet may fail. The LED indicator will spark twice and then stop after battery installed. The sensor is good, if you put your hand within the sensing range and LED indicator sparks for one time. I. Problem: put hands within the sensing range, no light from LED indicator of the sensor, faucet does not deliver water Cause: Batteries are not supplying electricity to the sensor or inadequate electricity. Solution: 1. make sure the batteries are correctly installed. Check if the positive pole is connected to "+" mark on the plastic battery box. Check if negative pole is connected to "-" mark on the plastic battery box. 2. New batteries are correctly installed, LED indicator is always off, need to change the sensor control module. 3. Inadequate electricity: when hands are under the sensing range for 5 seconds, LED indicator blinks every 1.5 seconds, to indicate inadequate electricity, please change batteries. 4. New batteries are correctly installed. LED indicator sparks for 2 seconds and then off. Place hands within sensing range, if LED indicator lights up once, but you cannot hear the audible "click" sound from the solenoid valve, please check the connections between the sensor control model and solenoid valve. If the connections are good, please change the solenoid valve components II. Problem: faucet delivers water when sensor is activated, but water flow is small Cause: low water pressure, water supply stop(s) are partially closed Solution: refer to installation step3 increase water pressure, open the water supply stop(s) fully. III. Problem: faucet delivers water when sensor is activated, but cannot close completely Cause 1: sand/dirty may have blocked the solenoid valve Solution 1: disassemble the solenoid valve and clean it; change solenoid valve components if problem cannot be solved. Cause 2: low water pressure Solution 2: increase water pressure IV. Problem: put hand before sensor, LED indicator lights up, but faucet cannot deliver water or water always running Cause 1: Inadequate electricity supply Solution 1: keep hand within sensing range for 5sec, if the LED indicator blinks every 1.5sec. It is a hint of inadequate electricity supply, please change batteries. Cause 2: Solenoid valve components defective Solution 2: check the connections between solenoid valve and sensor control model, if it is in good condition, please change solenoid valve components Contact Us: PAGE 7