EE 741 Over-voltage and Overcurrent. Spring 2014

Similar documents
Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

ECET Distribution System Protection. Overcurrent Protection

Pretest Module 29 High Voltage Unit 1

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

MAGNETIC MOTOR STARTERS

FUSE TECHNOLOGY Ambient temperature

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

GENERAL. CONSTRUCTION External

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

When power interruptions happen.

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Transformer Protection

Power systems Protection course

CMU medium voltage power fuses

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

K-Limiter high ampere Companion II fuse

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Wind Power Solutions. Make Energy Renewable and Reliable!

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

RUS accepted Catalog O-vst18

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Grounding Of Standby & Emergency Power Systems

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Solid Dielectric, Single Phase Recloser

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Pretest Module 29 High Voltage

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Power System Solutions (PSS)

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Advanced Protective Relay Training

Air-insulated switchgear UniGear type ZS1

3.2. Current Limiting Fuses. Contents

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

AutoLink Frequently Asked Questions

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Overview Overvoltage protection

FUSES. Safety through quality

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

SWITCHGEAR DIVISION PRODUCT PROFILES

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

2013 Grid of the Future Symposium. Utilizing Single Phase Operation Scheme on Untransposed 765kV lines for a Stability-Limited Plant

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

34 th Hands-On Relay School

Functions provided by measuring relays in railway equipment

HD4. Gas insulated MV circuit-breakers kv A ka

GE TRANQUELLTM Surge Arresters

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Zone Selective Interlock Module. For GE Circuit Breakers

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

KFE10002-E. Reclosers. Type KFE and KFVE Electronically Controlled Vacuum Recloser Installation Instructions. Service Information

Fuses still the best form of overload protection

3EK7 Distribution Class Surge Arresters. Answers for energy.

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

Three-Phase Pole Mounted Recloser

solutions RUS accepted

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Section 1 Introduction to the Presentation

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Presented to the IAPMO Standards Review Committee on December 9, 2013

GROUP D. Switch & Protective device.

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Cobra-S. Catalog Cobra-S

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

Eskom s unique type test requirements for lightning surge arrester ground lead disconnectors

Transcription:

EE 741 Over-voltage and Overcurrent Protection Spring 2014

Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with higher voltage systems

Ground Flash Density in US

Lightening Time Duration Usually less that a couple of hundred micro-seconds. Statistical Distribution of stroke duration reported by the industry. Reasonable approximation of lighting surge (8x20)

Current Magnitude, Rate of Rise, Polarity Typical magnitudes of stroke currents fall into the following range: Rate of rise: higher than 10 ka/μs over 50% of the time. Multiple strokes (from 2 to 40). 50% of direct strokes have at least 3 components. Cloud charge (-), earth s charge (+) in 90% of recorded measurements.

MOV Arrestors An MOV is a non-linear resistor whose function is to clamp the voltage (or divert the transient over-voltages) below the basic insulation level (BIL) of the apparatus it is protecting. The MOV contains a ceramic mass of zinc oxide grains, in a matrix of other metal oxides (such as small amounts of bismuth, cobalt, manganese) sandwiched between metal blocks.

Arrestor Class and Selection There are 3 classes of arrestors: distribution, intermediate, and station. A larger block reduces the IR discharge voltage and greatly increases energy capability. Proper selection of an MOV requires knowledge of the system s Maximum Continuous Operating Voltage (MCOV), and the magnitude and duration of the Transient Over- Voltages (TOV) during abnormal operating conditions. These are then compared to the arrestor MCOV and TOV capability.

Example A12 kv transformer has the following insulation characteristics: BIL (1.5x40 μs): 95 kv A 9 kv arrestor has an IR discharge at 20 ka of 36 kv. Insulation margin =100x(95-36)/95 = 62%. Recommended minimum protection margin: 20%

Arrester Placement Arrestors are place at the terminals of each piece of equipment, at riser poles, and along the feeder. Most surges in feeders are induced by nearby lightning strikes (induced voltages are usually less than 300 kv). Critical flashover of typical overhead distribution feeders is usually between 100-300 kv. Direct strikes will likely cause flashover.

Wire Theft Caught on Camera!

Over-Current Protection Fuses Relay-controlled circuit breakers Automatic circuit reclosers Automatic line sectionalizers

Fault Current on Radial Feeders Fault current decreases with distance from the substation. Protection of faults far out on the feeder cannot be protected at the substation.

Characteristics of Fuses Although a fuse is deceptively simple in appearance, its function is complex. The fuse length and diameter are the main determinants of its characteristics. For a fuse to function properly, it must sense the condition it is trying to protect, interrupt the fault quickly, and coordinate with other protective devices. An expulsion fuse expulses gases during its operation to de-ionize the arc and allows a rapid buildup of dielectric strength to withstand the transient recovery voltage.

K-Type and T-Type Expulsion Fuses Same Time-Current-Curve (TCC) for low currents The T link reacts more slowly than the K link at high current.

Fuse Characteristic: Minimum Melt Curve and Maximum Clearing Curve 10% is subtracted from average melt time, and 10% is added to average clearing time from electrical tests

Over-Current Relay Characteristics Sensitivity: operate under minimum fault current condition expected, Selectivity: differentiate between conditions in which immediate action is required to those for which time-delayed action is required. Speed: ability to operate in the required time period.

Recloser Similar to a circuit breaker, the recloser is a self-contained device which can sense and interrupt fault currents as well as reclose automatically in an attempt to reenergize the line. A recloser has less current interrupting capability and costs considerably less. A recloser utilizes two inverse time curves: Instantaneous curve (to save lateral fuses under temporary fault conditions) Time delay curve (to delay recloser tripping and allow the fuse to blow under permanent fault conditions.

Sectionalizer A sectionalizer is used in juction with a recloser or breaker to isolate faulted sections of lines. A sectionalizer does not interrupt fault current. Instead, it counts the number of operations of the reclosing device, and opens when this backup device is open. After the sectionalizer opens, the backup device recloses to return power to the unfaulted sections of the line. If the fault is temporary, the sectionalizer will reset itself after a prescribed period of time.

Over-Current Protection Device Placement Fuses and circuit breakers on customer side of meter. Fuses at each distribution transformer. Fuses at the head of each lateral. Circuit breaker at the substation. Recloser along the feeder (in case where the protection zone of the station circuit breaker is limited).

Typical Reclosing Sequence

Coordination: Fuse-to-Fuse

Coordination: Recloser-to-Fuse

Bushings a bushing is an insulated device that allows an electrical conductor to pass safely through a grounded conducting barrier such as the case of a transformer or circuit breaker. Bushings are typically made from porcelain. When an energized conductor is near a material at earth potential, it can form very high electric field strengths. The bushing controls the shape and strength of the field and reduces the electrical stresses in the insulating material. A typical bushing design has a conductor, surrounded by insulation, except for the terminal ends.

Can you differentiate between the phone/cable lines and power lines in the spider webs below?