ISLAND INSTALLATION WALL INSTALLATION

Similar documents
Viking Installation Guide

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848

Viking Installation Guide

INSTALLATION INSTRUCTIONS

DCWL Designer Chimney Wall Hood w/ledge*

VENTILATION. Standard Features & Accessories. Model Options. Designer Built-In Wall Hoods

Installation. Professional Indoor & Outdoor Hoods

o Brass Trim Option (BR) nameplate,

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Viking Installation Guide

ISLAND RANGE HOOD SPECIFICATIONS

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Designer Wall Range Hood Installation. Installation Tutorial Video

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Viking Installation Guide

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

VENTILATION SYSTEM WALL MOUNT CHIMNEY HOODS CHIMNEY HOODS FOR CUSTOM BUILT-IN HOODS

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style

REMOVAL AND INSTALLATION

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

Pro Series Ventilation Blowers Parts Manual

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Filter Hood Model CA-S

SECTION 3. PARTS INFORMATION

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Removal and Installation

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

W-VI Series - Internal Make-up Air Wall Canopy

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

When Time Matters! listed Fire Damper

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Glenn Rogers-Cabinet Broker rtacabinetbroker.com NA NA 排風量 CFM 110. 天花 / 牆身 Ceiling or wall mounted. 4 吋圓管槽排氣 4" round vented

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Pro Island Ventilation Hoods

www. TheRangeHoodStore.com

RANGE, RANGETOP AND VENTILATION MATRIX PROFESSIONAL SERIES

ECCODUCT. In-Slab Duct Ventilation System ECCO is proud to be a member of: REV. W-4

MODEL FF50 CEILING FAN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

All (-4) Models 390CFM Code Compliant

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Suitable For: Bathroom Living Area Whole House Ventilation Duct Boosting Hydroponic Growing General Ventilation

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

P R O D U C T G U I D E

Amalfi Electric Type C Stainless Steel Black Single Deck

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

High Capacity Ventilation

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Lights CONTINUED TURN SIGNAL/SIDE MARKER LIGHT HEADLIGHT PARKING LIGHT. Maintenance 237

GENERAL INFORMATION HANDLING PRECAUTIONS

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Ventilation Solutions

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets


Installation Instructions

8W Explosion Proof LED Exit Sign - C1D2 - Low Voltage - End, Ceiling, Back Mount - IP54

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

Delta BreezGreenBuilder G2 Perfectly quiet. Perfectly green.

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

DV Power Vent System Model 7THPDVS

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

Transcription:

HEIGHT OF HOOD The bottom of the hood should be 30 (76.2 cm) min. to 36 (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (175.3 cm) above the floor. The bottom of the hood should never be more than 72 (182.9 cm) above the floor or more than 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood. WALL INSTALLATION ISLAND INSTALLATION 3

WALL HOOD DIMENSIONS 30 /36 /42 W. PROFESSIONAL CHIMNEY HOODS A B 30 W. 36 W. 42 W. 29 7/8 (75.9 CM) 35 7/8 (91.3 cm) 41 7/8 (106.4 cm) 15 14 15/16 (37.9 cm) 17 15/16 (45.6 cm) 20 15/16 (53.2 cm)

WALL HOOD DIMENSIONS 48 /54 /60 /66 W. PROFESSIONAL CHIMNEY HOODS A B C 48 W. 47 7/8 (121.6 cm) 23 15/16 (60.8 cm) 18 (45.7 cm) 54 W, 53 7/8 (136.8 cm) 26 15/16 (68.4 cm) 18 (45.7 cm) 60 W. 59 7/8 (152.1 cm) 29 15/16 (76.0 cm) 24 (61.0 cm) 66 W. 65 7/8 (167.3 cm) 32 15/16 (83.7 cm) 24 (61.0 cm) 16

INSTALLING THE WALL HOOD DUCT COVER 1. Measure from top of the canopy to ceiling and subtract 1/8 (0.3 cm) for clearance. 2. Place the duct cover top inside the duct cover base and lower until desired height is found. (To eliminate scratches, make a mark on the duct cover top for the desired lowering point by subtracting 18 (45.7 cm) from the total height needed.) 3. Use the retaining nuts and bolts to fasten in place. 4. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. 5. Note: For installations with ceilings above 9 (22.9 cm), use optional duct extensions. See product literature for details Item 1 Item 3 B Max. Canopy Top A Mín. C Item 4 Duct Cover Top Item 2 Model A Mín. B Max C VCWH3048 12 (30.5 cm) 24 (61.0 cm) 12 (30.5 cm) VCWH3648 12 (30.5 cm) 24 (61.0 cm) 12 (30.5 cm) VCWH4248 12 (30.5 cm) 24 (61.0 cm) 12 (30.5 cm) VCWH4848 12 (30.5 cm) 24 (61.0 cm) 18 (45.7 cm) VCWH5548 12 (30.5 cm) 24 (61.0 cm) 18 (45.7 cm) VCWH6048 12 (30.5 cm) 24 (61.0 cm) 24 (61.0 cm) VCWH6648 12 (30.5 cm) 24 (61.0 cm) 24 (61.0 cm) Duct Cover Base 12 (30.5 cm) 5

BASIC SPECIFICATIONS INTERIOR AND EXTERIOR POWER HOODS WALL HOODS RECOM. NUMBER OF 250 WATT 120VAC/60Hz DESCRIPTION CFM 1 HALOGEN HEAT LAMPS FILTERS SPACERS MAX. AMPS3 (int.-interior; ext.-exterior) LIGHTS (Sold Separately) Center LH RH (Interior/Exterior) 30 W. 300 int./600 int./900 ext./1200 ext. 2 1 2 0 1 1 3.9/6.0/8.7/6.0 36 W. * 300 int./600 int./900 ext./1200 ext. 2 1 2 1 1 1 3.9/6.0/8.7/6.0 42 W.* 600 int./900 ext./1200 ext. 2 1 2 1 1 1 6.0/8.7/6.1 48 W. 1200 int./1200 ext./1500 ext. 3 2 2 1 1 1 11.5/8.5/9.2 54 W. 1200 int./1200 ext./1500 ext. 3 2 3 2 1 1 11.5/8.5/9.2 60 W. 1200 int./1200 ext./1500 ext. 4 2 3 2 1 1 11.9/8.9/9.7 66 W. 1200 int./1200 ext./1500 ext. 4 2 3 0 1 1 11.9/8.9/9.7 ISLAND HOODS RECOM. NUMBER OF 120VAC/60Hz DESCRIPTION CFM 1 HALOGEN FILTERS SPACERS MAX. AMPS3 (int.-interior; ext.-exterior) LIGHTS Center LH RH (Interior/Exterior) 36 W.* 600 int./900 ext./1200 ext. 4 4 2 2 2 3.9/6.6/3.9 42 W.* 600 int./900 ext./1200 ext./1500 ext. 4 4 2 2 2 4.7/7.4/4.8/5.5 54 W. 1200 int./1200 ext./1500 ext. 6 6 2 2 2 8.6/5.6/6.4 66 W. 1200 int./1200 ext./1500 ext. 8 8 2 2 2 9.5/6.5/7.3 *1200 or 1500 CFM exterior ventilator should be used when installed over ranges/rangetops with gas grill. RECOMMENDED MAX. DUCT MODEL NUMBER CFM 1 DUCT SIZE RUN 2 (ft.) For Use with hoods: DIV300 (interior) 300 7 round 50 DIV600 (interior) 600 7 round 50 DIV1200 (interior) 1200 10 round 50 DEV900 (exterior) 900 10 round 50 DEV1200 (exterior) 1200 10 round 50 DEV1500 (exterior) 1500 10 round 75 PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY VENTILATION PRODUCT 1. All CFMs stated are based on tests at.1 static pressure: without applying static pressure, CFM would be greatly overstated. 2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer. Straight runs and gradual turns are best; for example, each 90o elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run. Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance. Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used. Check with a qualified and trained installer or local codes for makeup air requirement, if any. 3. Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground. 2