Valves > standardized valves > electrically operated > Series KN-0, KN- NAMUR Technical details Connection Nominal size Series KN-0, KN- Temperature range Medium G1/4, Namur 6 mm -10 C... +70 C Filtered, oil-free and dried compressed air according to ISO 87-1:010, Class 7::4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10 C below lowest occurring ambient temperature. Materials Body: Al (adized), plastic, seals: NBR, inner parts: Al, steel and plastic IP 6 according to EN 609 Valves in accordance with 014/4/EU (ATEX) available. (Chapter 1) Electrically operated spool valve. The manual override is detent and is operated by screw driver. The model KN- has a coil with enhanced humitidy resistance and a additional gasket at the coil. The location pin, screws and seals are included. /-way-valves /- and /-way-valves 1 1 KN-0-10-HN-xxx KN--10-HN-xxx /-way, single soleid, air spring return, NC KN-0-11-HN-xxx KN--11-HN-xxx /-way, single soleid, mechanical spring return, NC 14 4 1 14 4 1 14 4 1 14 4 1 KN-0-10-HN-xxx KN--10-HN-xxx /-way, single soleid, air spring return KN-0-11-HN-xxx KN--11-HN-xxx /-way, single soleid, mechanical spring return KN-0-0-HN-xxx KN--0-HN-xxx /-way, double soleid KN-0-0-HN-xxx KN--0-HN-xxx /-way, center position closed Please complete: xxx = electrical option 14 4 1 KN-0--HN-xxx KN---HN-xxx /-way, center position exhausted Electrical options -xxx Nominal voltage Power consumption Specifics Plug connection *1 KN-0 KN- V DC 4. W Form B industrial rm -441-741 V DC. W max. 8 bar Form B industrial rm -461-761 4 V DC 4. W Form B industrial rm -44-74 4 V DC 4.8 W M -O4-4 V DC. W max. 8 bar Form B industrial rm -46-76 4 V DC. W max. 8 bar M -O6-4 V AC 7/4 VA Form B industrial rm -4-7 11 V AC 7/4 VA Form B industrial rm -46-76 0 V AC 7/4 VA Form B industrial rm -47-77 * 1 Plug socket t included, suitable plug sockets see page. Subject to change 01
Valves > standardized valves > electrically operated > Series KN-0, KN- NAMUR Technical data Model-.: KN-0-10 KN--10 KN-0-11 KN--11 KN-0-10 KN--10 KN-0-11 KN--11 KN-0-0 KN--0 KN-0-0 KN--0 Operating pressure* (bar)...10...10...10...10...10...10...10 Pilot pressure* (bar)...10...10...10...10...10...10...10 Flow rate (Nl/min) 780 780 900 800 900 680 680 Response time (ms) at 6 bar on: 16 off: 18 on: 1 off: 16 on: 16 off: 17 on: 16 off: 18 on: 14 off: 14 on: 14 off: 16 Weight (kg) 0.0 0.0 0.0 0.0 0.440 0.440 0.440 Dimensions * max. 8 bar at. W and. W KN-0- KN-- on: 14 off: 16 M-04-10-HN. KN-0-1x-HN, MO-04-10-HN KN--1x-HN 1 44 19 4 Ø. 68 40 9 M-04-10-HN. KN-0-1x-HN, MO-04-10-HN KN--1x-HN KN-0-0-HN, KN--0-HN, KN-0-x-HN, KN--x-HN 1 19 4 Ø. 40 4 68 4 10 18 04 1 = pressure inlet,4 = outlets, = exhausts Plug socket (t included in scope of delivery) can be repositioned by 180. Soleid coil can be repositioned by 4 x 90. 0 Subject to change
Valves > electrically valves > operated electrically valves operatede > accessories valves > Plug sockets Form B according to DIN EN 1701-80 Contact distance mm 10 mm P + E IP 6 according to EN 609 requires a flat gasket Model-.: Voltage (AC/DC) Status indicator Protective circuit Connecting cable Wire cross section Ø Connecting cable 0-0 V without max. 1. mm² 6-8 mm 8-ST-01-G Form B industrial rm Contact distance mm 11 mm P + E IP 6 according to EN 609 requires a flat gasket M-04, M-0, M-07, M-, KM-09, KM-10, MS-18, KN-0, MN-06, MI-01, MI-0, MI-0 Model-.: 8-ST-01 8-ST-04-1 8-ST-04-7 8-ST-06-1 8-ST-06-7 8-ST-06-K-1* 8-ST-06-K-7* Voltage (AC/DC) 0-0 V 10-0 V 70-0 V 4 V 0 V 4 V 0 V Status indicator yes yes yes yes yes yes Protective circuit yes (varistor) yes (varistor) yes (varistor) yes (varistor) Connecting cable without without without without without m m Wire cross section max. 1. mm² max. 1. mm² max. 1. mm² max. 1. mm² max. 1. mm² x 0.7 mm² x 0.7 mm² Ø Connecting cable 6-8 mm 6-8 mm 6-8 mm 6-8 mm 6-8 mm * These plug sockets are fitted with integrated flat gaskets. Dimensions Form B according to DIN EN 1701-80 Form B industrial rm. 8.8 10. 8.8 11 41. 41. M. 9 8.6 M 8. 14. 8.6 1. 1. Subject to change 0
valves Valves > electrically operatede valves > > spare parts > Soleid coils Form B according to DIN EN 1701-80 mm Contact distance 10 mm P + E IP 6 according to EN 609 with connected plug socket Duty cycle 100 % Temperature range* -0 C... +0 C Voltage tolerance ± 10 % * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-.: -SP-011-G-4 -SP-011-G-47 Voltage 4 V DC 0 V AC Power consumption DC 4. W - Power consumption AC - 4.0 VA Form B industrial rm Contact distance mm 11 mm P + E Duty cycle 100 % Temperature range* Voltage tolerance ± 10 % IP 6 according to EN 609 with connected plug socket -0 C... +0 C M-04, M-0, M-07, M-, KM-09, KM-10, MS-18, KN-0, MN-06, MI-01, MI-0, MI-0 * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-.: -SP-011-411 -SP-011-4 -SP-011-4 -SP-011-46 -SP-011-47 -SP-0-41 -SP-0-4 Voltage V DC 4 V DC 4 V AC 11 V AC 0 V AC V DC 4 V DC Power consumption DC 4. W 4. W - - -. W. W Power consumption AC - - 4 VA 4 VA 4 VA Model-.: -SP-011-1-711 -SP-011-1-7 -SP-011-1-7 -SP-011-1-77 -SP-0-1-7 Voltage V DC/ 4V AC 4 V DC/ 48 V AC 110/11 V AC 0 V AC 4 V DC Power consumption DC 4.6 W 4.8 W - -. W Power consumption AC 7.1 VA 7.7 VA 6.0 VA/ 7.6 VA 7.9 VA - Specifics Enhanced humidity resistance. 04 Subject to change
Valves > electrically valves > operated electrically valves operatede > spare valves parts > Soleid coils M connection mm Contact distance - P IP 6 according to EN 609 with connected plug socket Duty cycle 100 % Temperature range* -0 C... +0 C Voltage tolerance ± 10 % * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-.: -SP-011--O -SP-0--O Voltage 4 V DC 4 V DC Power consumption DC 4.8 W. W Power consumption AC - - Specifics Mounting on manifold t allowed. With integrated LED and protective circuit. Min. mounting distance for manifold mounting is 0 mm. With integrated LED and protective circuit. Dimensions Form B according to DIN EN 1701-80 Form B industrial rm Ø9.1 8. 8. Ø9.1 0. Ø8.1 Ø16 1. M Ø8.1 1. M 9. M connection Ø16 10 Ø9.1. 1. 4. 9. Ø8.1 Ø16 Subject to change 0
valves Valves > electrically operatede valves > > technical information > Voltage code - HN * - * * * Manual override HN detent HNR detent HNT n-detent 0 Technical information Coil and plug options ATEX GD, encapsulated with casting compound width 0 mm Coil type -SP-07 1 with coil and plug 4 with coil, without plug without coil 6 without pilot valve 7 8 9 with coil, with enhanced humidity resistance, without plug with coil, with enhanced humidity resistance, with plug ATEX GD, intrinsically safe, with plug width 0 mm -SP-08 A ATEX GD, without plug, width 0 mm -SP-040 B ATEX GD, with plug, width 0 mm -SP-040 C ATEX GD, without plug, width mm -SP-041 D E F G H I J K L M ATEX GD, encapsulated with casting compound width mm with coil, with enhanced humidity resistance, without plug, low temperature version with coil shape B according to DIN EN 1701-80, with plug with coil shape B according to DIN EN 1701-80, without plug with coil shape A according to DIN EN 1701-80, without plug (if t standard) with coil shape A according to DIN EN 1701-80, with plug (if t standard) with coil, with plug with LED and protective circuit with coil, with plug with LED, without protective circuit -SP-06 -SP-060-1 -SP-011-G -SP-011-G -SP-016 -SP-016 N with coil with M connection O P with coil with M connection with LED and protective circuit without connector bridge, without plug Q with coil with with cable R with cable up to 1 m length S T with connector bridge, without plug U ATEX GD, without coil (for coil -SP-06) V W X ATEX GD, Flame proof enclosuresand encapsulated with casting compound ATEX GD / GD, without coil (for coil -SP-041 and -SP-04) ATEX GD, without coil (for coil -SP-040 in 0V AC and 11V AC) Y ATEX GD, without coil (for coil -SP-08) Z ATEX GD / GD, without coil (for coil -SP-040 in 4V DC and -SP-07) -SP-04 0 1 4 6 7 Manual override position on side of without indication ports 1//() DC ports 1//() AC ports 1//() DC, low power consumption ports 1//() DC ports /(4) AC ports /(4) DC, low power consumption ports /(4) without indication ports /(4) 0 Voltage without indication 1 V 4 V 4 V 4 48 V 110 V 6 11 V 7 0 V 8 40 V 9 A B C D E F 4 V 6 V 8 V 61 V 6 V 9 V Not all options are suitable for all valve series 06 Subject to change