Installation Instructions

Similar documents
Operating instructions

Operating instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Installation Instructions

Mechanical operating instructions

Mechanical Operating Instructions

Operating Instructions for Roll-Up Door Operators / MDF

Electrical operating instructions

Electrical Operating Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Operating manual. Custom made gearboxes

Electrical operating instructions

Operating Instructions

Ex m Solenoid Operator Type 0519

Electrical operating instructions

Electrical operating instructions

Support T10552 T10595 T40386

Installation instructions

Installation instructions

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Electrical operating instructions

Assembly and Maintenance Manual Type ASNU

Installation and Operating Instructions Magnetic Vibrator MR 1

Electrical Operating Instructions

Assembly and Maintenance Manual Type RSBW

Compensation unit AGE-XY 50-80

VEM motors Thurm GmbH

Compact System NRGS 11-2 NRGS Original Installation Instructions English

ELEKTROMATEN SI Rapid Safedrive. Emergency manual operation. Door controls. Limit switches. Mounting. Special versions. Series SG63F SI 17.

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

User Guide AMF Floor / Portrait Adaptor

Assembly and Maintenance Manual Type AS

Wilo-Control SC-Fire Jockey

Actuators for air dampers and control valves of oil burners

Assembly and Operating Instructions

Air terminal devices

ELEKTROMATEN ST Sliding-door-drive

Solenoid Operator 0516 / 1216

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Operation and Installation Instructions Version

Solenoid Operator 0513 / 1213

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

HST-BL-2830MS & HST-BL-2830MS-USA

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

2-finger parallel gripper GM

MV Series Motors Operation & Parts Manual

Swiveling gripper finger GFS 16-40

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Technical Documentation

Chain wheel rolling door drives DKM 170, 250, 350, 500 and 750 WKM 170

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

MANUAL. Single charger

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

Operation manual Flexible pin type coupling according to KWN 22014

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Timing-Belt Reverse Unit 8 80 R50 II Notes on Use and Installation

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Operating manual. Standard planetary gearboxes

Bowl Feeder BF10 / BF15 Translation of original operating instruction

2-finger angular gripper PWG

Mounting and Maintenance Instructions

Operating instructions Spray nozzle SDU

Operating Instructions for Control CS 300

Electromotoric Actuators

Please read and observe

Oil-free piston compressors KK and piston vacuum pumps KV

EStrong-series Emergency Stop

Instruction manual Electric glass door lock Touch-to-open

Instruction manual. CSV 402 caravan power supply. Table of contents

Actuators for air dampers and control valves of oil burners

Mobile greasing system 27846

MKey9-series Safety Interlock Switch with Guard Locking

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

DIAPHRAGM LIQUID PUMP NF 1.25

ELEKTROMATEN SI FI Safedrive with built-on frequency inverter

ELEKTROMATEN SE Sectional-door-drive. Emergency manual operation. Special versions. Limit switches. Door controls. Mounting

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Shaft mounted rolling door drives DFM/DFE 100, 170, 250, 350, 500 and 750 WFM/WFE 170

Small gripper with large stroke KGG

Stacking gripper SG 47

Spring-applied single-disc brake. Operating Instructions A00 CLASSIC LINE

IGLOO IGLOO EASY INSTRUCTION MANUAL

Operating instructions Solenoid interlock EX-AZM About this document. Content

Service - Safety Manual

Battery Charger JCB- SCH20LI.2

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

DC Master 24/ A

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

2-Finger-Parallel-Gripper PFH

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

L Charger. Instruction manual

Operating Instructions

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

Transcription:

Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016

2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales@gfa-elektromaten.co.uk www.gfa-elektromaten.co.uk

Table of contents 1 General safety information... 4 2 Technical Data... 5 3 Mechanical installation... 6 4 Electrical installation... 10 5 Limit switch adjustment... 11 6 Motor connection... 12 7 Alternative motor connection... 12 8 Limit switch connection... 13 9 Emergency manual operation KNH (hand chain operator)... 14 10 Completing commissioning / inspection... 15 11 Declaration of incorporation / conformance... 17 Symbols Warning - Potential injury or danger to life! Warning - Danger to life from electric current! Note - Important information! Requirement - Required action! Schematic representations are based on product examples. Deviations from delivered products are possible. 3

1 General safety information Specified normal use The drive unit is intended for sectional doors with full counter-balancing. The safe operation is only guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. No liability for damage caused by other applications or non-observance of the information in the manual. Modifications are only permitted with the agreement of the manufacturer. Otherwise the Manufacturer s Declaration shall be rendered null and void. Safety information Installation and initial operation tasks are to be performed by trained, skilled fitters only. Only trained electrical craftsmen are permitted to work on electrical equipment. They must assess the tasks assigned to them, recognise potential danger zones and be able to take appropriate safety measures. The installation is only to be carried out with the supply off. Observe the applicable regulations and standards. Coverings and safety devices Do not operate unless corresponding coverings and safety devices are fitted/installed. Ensure that gaskets are correctly positioned and cable glands are correctly tightened. Spare parts Use only original spare parts. 4

2 Technical Data Type SG 63 Output torque 150 Nm Output speed 48 rpm Output shaft / hollow shaft 25,40 mm Maximum output speed open / close for frequency inverter operation 48 / 48 rpm Supply voltage 3~ 400 V Operating current 1,90 A Operating frequency 50 Hz Power factor cos φ 0,54 Maximum movement per hour 12 h -1 Hand forces 87 N Class of protection IP 54 Limit switch range (maximum revolutions of output shaft / hollow shaft) 40 Braking torque 9 Nm Braking voltage 103-130 V DC Rectifier type EGR 230/103 Temperature range -10 / +40 (+60) C When using a temperature range of +40...+60 C use half of maximum movements per hour. 5

3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques ( refer to technical data). Connection elements Self-locking connection elements with a minimum strength of 800 N/mm 2 (8.8) must be used. Utilize the hole diameter to the full. Use adequately dimensioned washers for elongated holes. BAGAB00002_Z002 BAGAB00003_Z002 3 : 1 Permissible mounting positions BAGAC02002_Z002 6

Mounting Eight threads are provided for mounting (1). A key is used to connect to the door shaft. Use a key that is at least as long as the hollow shaft (2). BAGAD02003_Z002 7

Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life! During installation, be sure to use a lifting device that has a sufficient load-carrying capacity. Thoroughly grease the door shaft. BAGAE02001_Z001 Mount the keys. Pay attention to the possible versions A or B. BAGAE02003_Z002 8

Attach the drive unit. BAGAE02005_Z002 Tighten all connection elements (M8) to 25 Nm. Install all other connection elements according to the specifications of the door manufacturer. BAGAE02009_Z002 25 Nm Secure the keys (version B only). BAGAE02012_Z003 9

4 Electrical installation Warning - Danger to life from electric current! Switch the mains OFF and check that the cables are de-energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover. Insert the motor plug. Insert the limit switch plug. BAH AA03_Z001 BAHAC13_Z001 Completing the electrical installation Mount the cable entries and/or cable glands. 10

5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel. 11

6 Motor connection G1 M1 X13 Y1 Rectifier EGR Motor Motor plug Brake 7 Alternative motor connection G1 M1 X13 Y1 Rectifier EGR Motor Motor plug Brake 12

8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B (RS485) 3 Ground 4 Channel A (RS485) 5 Safety circuit 6 Supply network 13

9 Emergency manual operation KNH (hand chain operator) The emergency manual operation is provided as a means of opening or closing doors that do not have electric power supply. Operation interrupts the control voltage. Electrical operation is no longer possible. Warning - Injury through improper operation! Disconnect the voltage Adopt a secure position For drives that have a brake, emergency manual operation should carried out with the brakes on Caution - Component damage can result! Do not move the door beyond the final limit positions. Pull the red grip to activate. Pull the chain to open or close. Pull the green grip to deactivate. 14

10 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition. Electrical wiring Check the connection cables and cabling for damage or crushing. Check that the screw connections and plug connections are fitted properly with a good electric contact. Emergency manual operation Check the function with the power disconnected. Perform the check only between the final limit positions. Limit switch Check the final limit positions by opening and closing fully. The safety area must not be approached. 15

Brake Warning - Potential injury or danger to life! Carry out a brake test. Overrun depends on the door and its equipment. The specifications of the door manufacturer must be observed. Brake lift may only be used in the final limit position CLOSE for doors that have no counter-balancing. Warning - Potential injury or danger to life! Lifecycle brake - change complete brake unit at: Operation with mains supply after 250.000 cycles Operation with Inverter after 1.000.000 cycles In an environment that can affect the coefficient of friction of the brake pad (atmosphere with oil, solvents, detergents, etc.), class of protection IP65i must be adopted. Drive unit Note! Engage a qualified engineer to check the drive unit annually Apply shorter inspection intervals for doors that are operated frequently Observe the applicable regulations and standards 16

11 Declaration of incorporation / conformance Declaration of incorporation in the terms of Machinery Directive 2006/42/EC for partly completed machinery, Appendix II Part B Declaration of conformity in terms of EMC Directive 2014/30/EU We, the GfA ELEKTROMATEN GmbH & Co. KG hereby declare that the following products are conform with the above EC Guideline and are only intended for installation in door equipment. SE 15.48-25,40 Standards applied DIN EN 12453 DIN EN 12604 DIN EN 60335-1 DIN EN 61000-6-2 DIN EN 61000-6-3 Doors - safety in use of power operated doors Doors - Mechanical aspect Safety of household and similar electrical appliances Purposes - Part 1 : General requirements Electromagnetic compatibility (EMC) Part 6-2 Generic standard Immunity standard for industrial environments Electromagnetic compatibility (EMC) Part 6-3 Generic standard Emission standard for residential, commercial and light-industrial environments We undertake to transmit in response to a reasoned request by the appropriate regulatory authorities the special documents on the partly completed machinery. Authorised representative for the compilation of the relevant technical documents (internal EU address) Dipl.-Ing. Bernd Synowsky Documentation representative Incomplete machines within the meaning of the EC Directive 2006/42/EC shall only be intended to be integrated into other machines (or into other incomplete machines/systems) or to be assembled with them to form a complete machine within the sense of the Directive. Therefore, this product cannot be commissioned before it is determined that the entire machine/system to which it was integrated shall comply with the provisions of the Machinery Directive indicated above. Düsseldorf, 24.11.2015 Stephan Kleine CEO Signature 17

18

19

20