Diaphragm-Gas Sampling Pumps N 0150 ANE N 0150 ATE N 0150 STE N ANE N ATE N STE

Similar documents
Diaphragm-Gas Sampling Pumps

Swing Piston Compressors and Vacuum Pumps

Diaphragm Vacuum Pump and Compressor

Swing Piston Compressors and Vacuum Pumps

Diaphragm Pumps N 1200 A_E N 1200 S_E N A_E N S_E N A_E N S_E N A_E N S_E

DIAPHRAGM LIQUID PUMP DATA SHEET NF 2.35 NF 2.35

Diaphragm Vacuum Pumps and Compressors

Swing Piston Compressors and Vacuum Pumps

MICRO DIAPHRAGM GAS PUMPS NMP 830, NMP 850 and NMP

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS TO ATEX

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pump

N 2400 SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pump

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Micro Diaphragm Gas Sampling Pumps

Diaphragm Gas Sampling Pumps

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM VACUUM PUMP

DIAPHRAGM LIQUID PUMPS

Operating and Installation Instructions Mini Diaphragm Vacuum Pumps

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Swing Piston Compressors and Vacuum Pumps

DIAPHRAGM LIQUID PUMP

SOLENOID DIAPHRAGM METERING PUMP

DIAPHRAGM LIQUID PUMP NF 1.30

KNF LIQUID PUMPS PRODUCT RANGE

Micro Diaphragm Gas Sampling Pumps

KNF LIQUID PUMPS PRODUCT RANGE

KNF LIQUID PUMPS PRODUCT RANGE

DIAPHRAGM LIQUID PUMP NF 2.35

Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM LIQUID PUMP NF 1.25

DIAPHRAGM LIQUID PUMPS

Micro Diaphragm Gas Sampling Pumps

KNF RC 900 Rotary Evaporator. easy to use.

DIAPHRAGM LIQUID PUMP NF 30, NFB 30

Micro diaphragm liquid pump NF 1.5 NFB 5

DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11

Micro diaphragm liquid pump NF 25 NFB 25

DIAPHRAGM METERING PUMP FEM 1.02, FEM 1.09

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DIAPHRAGM LIQUID PUMP NF 100, NF 1.100, NFB 100

DIAPHRAGM VACUUM PUMP

Diaphragm Vacuum Pumps and Compressors

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Diaphragm Vacuum Pumps and Compressors

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Diaphragm Pumps for Air, Gases and Vapours LABOPORT Mini Diaphragm Vacuum Pumps and Compressors

Operating Instructions

Pressure relief valve

Analytical Diaphragm Pump Series MP MP06, MP12

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

LIQUIPORT DIAPHRAGM LABORATORY PUMP

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

MINI DIAPHRAGM VACUUM PUMPS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Installation and Operation Manual

Type 6213 EV, 6281 EV

High Vacuum Diaphragm-Type Dry Vacuum Pump

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

UView Mini Transilluminator

Turbocharger / TPS-H Original assembly instructions English

Installation and operating manual

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Oil-free piston compressors KK and piston vacuum pumps KV

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Type 3320, Service Manual. Serviceanleitung Service Manuel

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type AS

Application cup for OptiFlex 2 GM03 manual powder gun

Turbocharger / A100-L Original assembly instructions English

Lumitester PD-20 Control Kit

These installation and maintenance instructions must be read in full and completely understood before the installation!

Installation, Operation, and Maintenance Manual

Industrial flue gas probes. Instruction manual

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Turbocharger / TPL-B Original assembly instructions English

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Assembly and Maintenance Manual Type ASNU

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

DIAPHRAGM PUMP OEM KNF /18 N 816 TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

Angle seat valve with piston actuator VZXA-...-K

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Rectangular Door L-VAT with pneumatic actuator double acting

Installation, Operation, and Maintenance Manual

original operating manual Operating manual Translation of the Item-No.: ,

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Transcription:

Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Diaphragm-Gas Sampling Pumps N 0150 ANE N 0150 ATE N 0150 STE N 0150.1.2 ANE N 0150.1.2 ATE N 0150.1.2 STE N 0150.3 ANE N 0150.3 ATE N 0150.3 STE KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664-5909-0 Fax +49-(0)7664-5909-99 E-mail: info@knf.de www.knf.de Contents Page 1. About this document... 2 2. Use... 3 3. Safety... 4 4. Technical Data... 6 5. Design and function... 9 6. Installation and connection... 11 7. Operation... 14 8. Servicing... 16 9. Troubleshooting... 21 10. Spare parts and accessories... 23 11. Decontamination declaration... 24 KNF 120859-121488 08/13 Operating and Installation Instructions, english

About this document 1. About this document 1.1. Using the Operating and Installation Instructions The Operating and Installation Instructions are part of the pump. Pass on the Operating and Installation Instructions to the next owner. Project pumps Customer-specific project pumps (pump models which begin with "PJ" or "PM") may differ from the Operating and Installation Instructions. For project pumps, also observe the agreed upon specifications. 1.2. Symbols and markings Warning A danger warning is located here. WARNING Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. Warning, indicates the danger level. Measures for avoiding the danger and its consequences are specified here. Danger levels Signal word Meaning DANGER warns of immediate danger WARNING warns of possible danger CAUTION warns of a possibly dangerous situation Consequences if not observed Death or serious injuries and/or serious damage are the consequence. Death or serious injuries and/or serious damage are possible. Minor injuries or damage are possible. Tab. 1 Other information and symbols An activity to be carried out (a step) is specified here. 1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow. This symbol refers to important information. 2 Operating and Installation Instructions, english, KNF 120859-121488 08/13

Use Operating parameters and conditions Requirements for transferred medium 2. Use 2.1. Proper use The pumps are exclusively intended for transferring gases and vapors. Owner's responsibility Only install and operate the pumps under the operating parameters and conditions described in Chapter 4, Technical data. Protect the compressors with a pressure relief device between the pressure side of the compressor and the first shut-off valve. Only complete pumps may be taken into service. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The gas-tightness of the connections between the application pipes and the pump (or the pump connection) must be checked regularly; with leaky connections, there is a danger that hazardous gases or vapours may escape from the pump system. Before using a medium, check whether the medium can be transferred danger-free in the specific application case. Before using a medium, check the compatibility of the materials of the pump head, diaphragm and valves with the medium. Only transfer gases which remain stable under the pressures and temperatures occurring in the pump. 2.2. Improper use The pumps may not be operated in an explosive atmosphere. The pumps are not suitable for transferring dusts. The pumps are not suitable for transferring liquids. Pumps designed to create either a vacuum or an overpressure must not be used for these two purposes simultaneously. An overpressure must not be applied to the suction side of the pump. Pumps with three-phase motor are not provided for the operation with frequency converter. Operating and Installation Instructions, english, KNF 120859-121488 08/13 3

Safety 3. Safety Note the safety precautions in chapters 6. Installation and connection, and 7. Operation. Personnel Working in a safetyconscious manner Handling dangerous media Handling combustible media Environmental protection EC Directives / Standards The pumps are built according to the generally recognized rules of technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during their use which lead to injuries to the user or others, or to damage to the pump or other property. Only use the pumps when they are in a good technical and proper working order, in accordance with their intended use, observing the safety advice within the Operating and Installation Instructions, at all times. Make sure that only trained and instructed personnel or specially trained personnel work on the pumps. This especially applies to assembly, connection and servicing work. Make sure that the personnel has read and understood the Operating and Installation Instructions, and in particular the "Safety" chapter. Observe the accident prevention and safety regulations when performing any work on the pump and during operation. The pump heads heat up during operation avoid contact with them. When transferring dangerous media, observe the safety regulations when handling these media. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium (compressor operation). Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (chapter 4). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations. Observe the respective national and international regulations. This especially applies to parts contaminated with toxic substances. For the purposes of the Machinery Directive 2006/42/EC, pumps are partly completed machinery, and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the 4 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Safety Customer service and repairs machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: General Principles No. 1 No. 1.1.2. / 1.1.3. / 1.3.1. / 1.3.3. / 1.3.4. / 1.4.1. / 1.5.1. / 1.5.2. / 1.5.8. / 1.5.9. / 1.7.4. / 1.7.4.1. / 1.7.4.3. As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. The pumps conform to the Directive 2011/65/EU (RoHS2). The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: DIN EN 55014-1/2 DIN EN 61000-3-2/3 DIN EN 60204-1 Only have repairs to the pumps carried out by the KNF Customer Service responsible. Use only genuine parts from KNF for servicing work. Operating and Installation Instructions, english, KNF 120859-121488 08/13 5

Technical Data 4. Technical Data Pump materials N 0150 ANE N 0150.1.2 ANE N 0150.3 ANE Assembly Head plate, intermediate plate Diaphragm Reed valves Retainer plate O-ring Material Aluminium EPDM Stainless Steel Stainless Steel EPDM Tab. 2 N 0150 ATE N 0150.1.2 ATE N 0150.3 ATE Assembly Head plate, intermediate plate Diaphragm Reed valves Retainer plate O-ring Material Aluminium PTFE-coated Stainless Steel Stainless Steel FPM Tab. 3 N 0150 STE N 0150.1.2 STE N 0150.3 STE Assembly Head plate, intermediate plate Diaphragm Reed valves Retainer plate O-ring Material Stainless Steel PTFE-coated Stainless Steel Stainless Steel FPM Tab. 4 Pneumatic values N 0150 ANE Parameter Value Max. permissible operating pressure [bar g] 2.0 Ultimate vacuum [mbar abs.] 100 Delivery rate at atm. pressure [l/min]* 150 Tab. 5 *Liters in standard state (1013 mbar) 6 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Technical Data N 0150 ATE N 0150 STE Parameter Value Max. permissible operating pressure [bar g] 2.0 Ultimate vacuum [mbar abs.] 115 Delivery rate at atm. pressure [l/min]* 120 Tab. 6 *Liters in standard state (1013 mbar) N 0150.1.2 ANE Parameter Value Max. permissible operating pressure [bar g] 2.0 Ultimate vacuum [mbar abs.] 100 Delivery rate at atm. pressure [l/min]* 280 Tab. 7 *Liters in standard state (1013 mbar) N 0150.1.2 ATE N 0150.1.2 STE Parameter Value Max. permissible operating pressure [bar g] 2.0 Ultimate vacuum [mbar abs.] 115 Delivery rate at atm. pressure [l/min]* 220 Tab. 8 *Liters in standard state (1013 mbar) N 0150.3 ANE Parameter Value Max. permissible operating pressure [bar g] - Ultimate vacuum [mbar abs.] 20 Delivery rate at atm. pressure [l/min]* 150 Tab. 9 *Liters in standard state (1013 mbar) N 0150.3 ATE N 0150.3 STE Parameter Value Max. permissible operating pressure [bar g] - Ultimate vacuum [mbar abs.] 25 Delivery rate at atm. pressure [l/min]* 120 Tab. 10 *Liters in standard state (1013 mbar) Pneumatic Connections Parameter N 0150 E and N 0150.3 E N 0150.1.2 E Value Thread size G 1/2 Taper bush type pipe union for pipe OD 18 Tab. 11 Operating and Installation Instructions, english, KNF 120859-121488 08/13 7

Technical Data Electrical data Parameter Electrical data Protection class motor Maximum permitted mains voltage fluctuations Value See type plate IP54 +/- 10 % Tab. 12 Thermal-switch The pumps with capacitor motor are fitted as standard with a thermal-switch to protect against overloading. Weight Pump type Weight (kg) N 0150 ANE ca. 21.5 N 0150 ATE N 0150 STE ca. 25.5 N 0150.1.2 ANE ca. 28.5 N 0150.1.2 ATE N 0150.3 ANE N 0150.3 ATE N 0150.1.2 STE ca. 36.0 N 0150.3 STE ca. 36.5 Tab. 13 Other parameters Parameter Permissible ambient temperature Values + 5 C to + 40 C Permissible media temperature + 5 C to + 40 C Dimensions N 0150 E: 380 x 257 x 202 L x H x W [mm] Dimensions N 0150.1.2 E and N 0150.3 E: L x H x W [mm] Maximum permissible ambient relative humidity Max. altitude of site [m above sea level] Tab. 14 386 x 282 x 371 80 % for temperatures up to 31 C, decreasing linearly to 50 % at 40 C 2000 8 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Design and function 5. Design and function Design N 0150 _E 1 Pneumatic outlet (G ½) 2 Pneumatic inlet (G ½) 3 Terminal box (electrical connection) 4 Motor 5 Grid Fig. 1: Diaphragm pump N 0150 E Design N 0150.1.2 _E 1 Pneumatic head connection suction side 2 Union nut 3 Pneumatic head connection pressure side 4 Motor 5 Fan cover 6 Pneumatic outlet (Tube OD 18) 7 Terminal box (electrical connection) 8 Pneumatic inlet (Tube OD 18) Fig. 2: Diaphragm pump N 0150.1.2 E Operating and Installation Instructions, english, KNF 120859-121488 08/13 9

Design and function Design N 0150.3 E 1 Pneumatic outlet (G ½) 2 Banjo bolt 3 Pneumatic head connection 4 Motor 5 Fan cover 6 Terminal box (electrical connection) 7 Pneumatic inlet (G ½) Fig. 3: Diaphragm pump N 0150.3 E Function Diaphragm Pump 1 Outlet valve 2 Inlet valve 3 Transfer chamber 4 Diaphragm 5 Eccentric 6 Connecting rod 7 Pump drive Fig. 4: Pump head Diaphragm pumps transfer, compress (depending on pump version) and evacuate gases and vapors. The elastic diaphragm (4) is moved up and down by the eccentric (5) and the connecting rod (6). In the downward stroke it aspirates the gas to be transferred via the inlet valve (2). In the upward stroke, the diaphragm presses the medium out of the pump head via the outlet valve (1). The transfer chamber (3) is hermetically separated from the pump drive (7) by the diaphragm. 10 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Installation and connection 6. Installation and connection Only install and operate the pumps under the operating parameters and conditions described in Chapter 4, Technical data. Observe the safety precautions (see Chapter 3). Mounting dimensions 6.1. Installation of the pump Before installation, store the pump at the installation location to bring it up to ambient temperature. See fig. 5 (pump series N 0150 E) or fig. 6 (pump series N 0150.1.2 E and N 0150.3 E) for the mounting dimensions. Fig. 5: Mounting dimensions pump series N 0150 E (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) Fig. 6: Mounting dimensions pump series N 0150.1.2 E and N 0150.3 E (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) Cooling air supply Installation location Install the pump so that the motor fan can intake sufficient cooling air. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. Operating and Installation Instructions, english, KNF 120859-121488 08/13 11

Installation and connection Disengaging The IP protection class of the pump motor is indicated on the type plate. Install the pump at the highest point in the system to prevent condensate from collecting in the pump head. Protect the pump from dust. Protect the pump from vibrations and jolts. KNF recommends mechanically disengaging the pump from the piping system. This can be achieved with flexible tubing or pipes, for example. This will avoid transferring to the system any pump oscillations that may arise. 6.2. Electrical connection Extreme danger from electrical shock DANGER Only have the pump connected by an authorized specialist. Only have the pump connected when the power supply is disconnected. When connecting the device to a power source, the relevant standards, directives, regulations, and technical standards must be observed. In the electrical installation, arrangements (complying with EN 60335-1) must be made for disconnecting the pump motor from the electrical supply. The motors of the pump must be protected according to EN 60204-1 (protection against excess current, or overloading). For operating current see type plate. It is recommended that an additional Emergency Stop switch is installed. The pump must be installed so that contact with live parts is impossible. Connecting pump 1. Compare the supply data with the data on the motor-plate. For operating current see type plate. The voltage must not vary by more than + 10% and - 10% from that shown on the type-plate. 2. Open terminal box cover. 3. All pumps except versions with 3 phase motor: Connect the mains cables to the connections L1 and N of the pump motor. 4. Connection of pumps with 3 phase motor according to figs. 7 or 8. 5. Connect the earth (ground) wire to the motor. 6. Close the terminal cover box. 12 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Installation and connection Mains Fig. 7: Y-Connection (high voltage) Mains Fig. 8: -Connection (low voltage) Connected components Pressure relief device Pump exhaust 6.3. Pneumatic connection Only connect components to the pump which are designed for the pneumatic data of the pump (see Chapter 4, Technical data). Protect the pump with a pressure relief device between the pressure connection of the pump and the first shut-off valve. If the pump is used as a vacuum pump, safely discharge the pump exhaust at the pump s pneumatic outlet. Connecting pump A marking on the pump head shows the direction of flow. 1. Remove the protective plugs from the hose connection threads. 2. Connect the suction line and pressure line (see chapter 4, table 11 for the mounting dimensions). 3. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump. Operating and Installation Instructions, english, KNF 120859-121488 08/13 13

Operation 7. Operation Only operate the pumps under the operating parameters and conditions described in Chapter 4, Technical data. Make sure the pumps are used properly (see chapter 2.1). Make sure the pumps are not used improperly (see chapter 2.2). Observe the safety precautions (see Chapter 3). The pumps are intended for installation. Before putting them into service it must be established that machinery or equipment in which they are installed meets the relevant regulations. Hazard of the pump head bursting due to excessive pressure increase WARNING Do not exceed max. permissible operating pressure (see Chapter 4, Technical data). Monitor pressure during operation. If the pressure exceeds the maximum permissible operating pressure, immediately switch off pump and eliminate fault (see Chapter 9. Troubleshooting). Only throttle or regulate the air or gas quantity in the suction line to prevent the maximum permissible operating pressure from being exceeded. If the air or gas quantity in the pressure line is throttled or regulated, make sure that the maximum permissible operating pressure is not exceeded. Ensure that the pump outlet is not closed or constricted. Excessive pressure (with all of the related hazards) can be prevented by placing a bypass line with a pressure-relief valve between the pressure and suctions sides of the pump. For further information, contact our technical adviser (see front page for telephone number). Automatic starting can cause personal injury and pump damage WARNING When the operation of the pump is interrupted by the thermal switch, the pump will restart automatically after cooling down. Take all necessary care to prevent this leading to a dangerous situation. 14 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Operation Pump standstill Vapors as media With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure. The pump may not start up against pressure or vacuum during switch-on. This also applies in operation following a brief power failure. If a pump starts against pressure or vacuum, it may block. This activates the thermal switch, and the pump switches off. Make sure that normal atmospheric pressure is present in the lines during switch-on. The life of the diaphragm is prolonged if the formation of condensate is avoided. Therefore the following precautions should be taken: Run the pump for a few minutes to warm it up before handling saturated or nearly saturated vapors. KNF recommends: When transferring aggressive media, flush the pump prior to switch-off (see Chapter 8.2.1) to increase the service life of the diaphragm. Operating and Installation Instructions, english, KNF 120859-121488 08/13 15

Servicing 8. Servicing 8.1. Servicing schedule Component Servicing interval Pump - Regular inspection for external damage or leaks Tube connection - Regular inspection for external damage or leaks Diaphragm and reed valves Tab. 15 8.2. Cleaning 8.2.1. Flushing pump - Replace at the latest, when pump output decreases KNF recommends: When transferring aggressive media, flush the pump under atmospheric conditions some minutes with air (or, if necessary for safety reasons, with an inert gas) prior to switch-off to increase the service life of the diaphragm. 8.2.2. Cleaning pump Only use solvents for cleaning if the head materials cannot be attacked (check the resistance of the material). If compressed air is available, blow out the components. 8.3. Replacing diaphragm and reed valves Conditions Motor disconnected from mains and de-energized Pump free of dangerous substances Tubes/pipes removed from pump s pneumatic inlet and outlet With multi-head pumps, parts of the individual pump heads can be confused. Replace working diaphragm, safety diaphragm and reed valves of the individual pump heads consecutively. Health hazard due to dangerous substances in the pump! WARNING Depending on the substance transferred, caustic burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. 16 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Servicing Spare parts Spare part* Position** Quantity Diaphragm (10) 1 (per pump head) O-Ring (16) 2 (per pump head) Reed valve for suction side Reed valve for pressure side (5) 1 (per pump head) (15) 1 (per pump head) Tab. 16 * According to spare parts list, chapter 10 ** According to Fig. 9. Tools and material Quantity Tools/Material 1 Allen key 4 with torque indicator 1 Allen key 5 with torque indicator 1 Screwdriver blade width 5.5 mm (only for one-headed pumps) 1 Phillips screwdriver No. 2 (only for two-headed pumps) 1 Adjustable pin-wrench for two-hole nuts, pin dia. 4 mm, length of wrench ca. 160 mm (available as wrench for retainer plate, a KNF accessory, see chapter 10) 1 Felt-tip pen Tab. 17 * according to accessories list, chapter 10 Operating and Installation Instructions, english, KNF 120859-121488 08/13 17

Servicing 1 Head plate 2 Hexagon socket head cap screw 3 Slotted cheese head screw 4 Limiter for suction side 5 Reed valve for suction side 6 Hexagon socket head cap screw 7 Intermediate plate 8 Housing 9 Retainer plate 10 Diaphragm 11 Diaphragm support 12 Connecting rod 13 Slotted cheese head screw 14 Limiter for pressure side 15 Reed valve for pressure side 16 O-ring Fig. 9: Pump parts The following item numbers refer to Fig. 9, unless otherwise indicated. Removing pump head 1. Take the steps necessary to gain access to the motor cooling fan: For one-headed pumps: Undo the screws that hold the grid (Fig. 1/5, p. 9) and remove the grid. For two-headed pumps: Undo the screws that hold the fan cover (Fig. 2/5, p. 9 or Fig. 3/5, p. 10) and remove the fan cover. 2. Only for two-headed pumps: Remove the pneumatic connection (.3 models), or connections (.1.2 models) between the pump heads: Loosen the union nuts (N 0150.1.2 E, Fig. 2/2, p. 9) or the banjo bolts (N 0150.3 E, Fig. 3/2, p. 10) to do so. 18 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Servicing 3. Mark the position of head plate (1), intermediate plate (7) and housing (8) relative to each other by a drawing line with a felttip pen. This helps avoid incorrect assembly later. 4. Undo the six hexagon socket head cap screws (6) and the two screws (2); lift off head plate (1) and intermediate plate (7). 5. For two-headed pumps: Carry out steps 3 and 4 for the second pump head. Changing diaphragm 1. To undo the retainer plate (9), use the wrench for retainer plate to turn it anti-clockwise; remove retainer plate and diaphragm (10). 2. Inspect all parts for dirt and clean them if necessary. 3. Turn the fan until the connecting rod (12) with the diaphragm support (11) is in mid-stroke. 4. Place the new diaphragm (10) on the diaphragm support (11); take care that the beads on the outer and inner edges of the diaphragm are properly seated in the grooves in housing and diaphragm support respectively. 5. Place the retainer plate (9) on diaphragm; use the wrench for retainer plate to tighten it up to stop. 6. For two-headed pumps: Carry out steps 1 to 5 for the second pump head. Changing reed valves 1. Remove the two O-rings (16) from the intermediate plate. 2. With a felt tip pen, mark the position of the suction side valve limiter (4) on the intermediate plate; undo the screw (3), and remove the valve limiter (4) and suction side reed valve (5). 3. After undoing the screws (13), remove the pressure side valve limiter (14) and reed valve (15) from the intermediate plate (7). 4. Fit new reed valves and valve limiters on pressure and suction sides. 5. For two-headed pumps: Carry out steps 1 to 4 for the second pump head. Operating and Installation Instructions, english, KNF 120859-121488 08/13 19

Servicing Mounting pump head 1. Place intermediate plate (7) on housing (8) according to the mark made previously (at the same time, keep the diaphragm in its mid-position by holding the motor fan). 2. Fit the two new O-rings (16) in the intermediate plate (7). 3. Place head plate (1) on intermediate plate (7) according to the mark made previously. 4. Screw the hexagon socket head cap screws (2) and (6) in one or two turns. 5. Tighten the two hexagon socket head cap screws (2) (tightening torque: 6 Nm); then tighten the six hexagon socket head cap screws (6) diagonally (tightening torque: 9 Nm). 6. Turn the fan to check that the pump rotates freely. 7. For two-headed pumps: Carry out steps 1 to 6 for the second pump head: 8. For one-headed pumps: Remount grid (Fig. 1/5, p. 9). For two-headed pumps: Remount fan cover (Fig. 2/5, p. 9 or Fig. 3/5 p. 10). 9. For two-headed pumps: Remount the pneumatic connection(s). 20 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Troubleshooting 9. Troubleshooting Extreme danger from electrical shock! DANGER Disconnect the pump power supply before working on the pump. Make sure the pump is de-energized and secure. Check the pump (see Tab. 18 and 19). Pump does not transfer Cause Pump is not connected with the power source. No voltage in the power source Thermal switch has operated following to over-heating. Connections or lines blocked. External valve is closed or filter is clogged. Condensate has collected in pump head. Diaphragm or reed valves are worn. Fault remedy Connect pump with the power source. Check room fuse and switch on if necessary. Disconnect pump from mains. Allow pump to cool. Trace cause of over-heating and eliminate it. Check connections and lines. Remove blockage. Check external valves and filters. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). Install pump at highest point in system. Replace diaphragm and reed valves (see Chapter 8.3). Tab. 18 Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Fault remedy Condensate has collected in pump head. There is gauge pressure on pressure side and at the same time vacuum or a pressure above atmospheric pressure on suction side. Pneumatic lines or connection parts have an insufficient cross section. Leaks occur on connections, lines or pump head. Connections or lines completely or partially jammed. Head parts are soiled. Diaphragm or reed valves are worn. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). Install pump at highest point in system. Change the pressure conditions. Disconnect pump from system to determine output values. Eliminate throttling (e.g. valve) if necessary. Use lines or connection parts with larger cross section if necessary. Eliminate leaks. Check connections and lines. Remove the jamming parts and particles. Clean head components. Replace diaphragm and reed valves (see chapter 8.3). Tab. 19 Operating and Installation Instructions, english, KNF 120859-121488 08/13 21

Troubleshooting Fault cannot be rectified If you are unable to determine any of the specified causes, send the pump to KNF Customer Service (see last page for the address). 1. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas) to free the pump head of dangerous or aggressive gases. 2. Clean the pump (see chapter 8.2). 3. Send the pump to KNF with a filled out decontamination declaration (see Chapter 11) and specification of the medium transferred. 22 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Spare parts and accessories 10. Spare parts and accessories Spare Parts N 0150 ANE N 0150.1.2 ANE N 0150.3 ANE Spare part Position* Order No. Diaphragm (10) 047013 Reed valve for suction side (5) 043951 Reed valve for pressure side (15) 043949 O-ring (16) 047016 Tab. 20 *according to Fig. 9 N 0150 ATE N 0150.1.2 ATE N 0150.3 ATE Spare part Position* Order No. Diaphragm (10) 116991 Reed valve for suction side (5) 043951 Reed valve for pressure side (15) 043949 O-ring (16) 002458 Tab. 21 *according to Fig. 9 N 0150 STE N 0150.1.2 STE N 0150.3 STE Spare part Position* Order No. Diaphragm (10) 116991 Reed valve for suction side (5) 043951 Reed valve for pressure side (28) 043949 O-ring (8) 002458 Tab. 22 * according to Fig. 9 Accessory Accessory Order No. Wrench for retainer plate 018816 Tab. 23 Operating and Installation Instructions, english, KNF 120859-121488 08/13 23

Decontamination declaration 11. Decontamination declaration The condition for the repair of a pump by KNF is the certification of the customer on the transferred media and on the cleaning of the pump (decontamination declaration). Copy this page. Enter the pump model, the Serial No. and the transferred media in the form below and sent the signed form together with the flushed and cleaned pump to KNF Customer Service (see last page for the address). Customer decontamination declaration for repair order We herewith confirm that the following media have been pumped with the pump listed below, and that the pump has been flushed and cleaned. Pump model Serial No. Fed media The pump contains neither aggressive, biological, radioactive, poisonous nor other dangerous media. Company Date/Signature 24 Translation of original Operating and Installation Instructions, english, KNF 120859-121488 08/13

Benelux Netherlands KNF Verder B.V. Utrechtseweg 4a NL-3451 GG Vleuten Tel. 0031 (0)30 677 92 40 Fax 0031 (0)30 677 92 47 E-mail: info@knf-verder.nl www.knf-verder.nl Benelux Belgium, Luxembourg KNF Verder N.V. Kontichsesteenweg 17 B-2630 Aartselaar Tel. 0032 (0)3 8719624 Fax 0032 (0)3 8719628 E-mail: info@knf.be www.knf.be China KNF Neuberger Trading (Shanghai) Co., Ltd No. 36 Lane 1000 Zhang Heng Road Shanghai 201203, P.R. China Tel. 0086 (0)21 685 965 66 Fax 0086 (0)21 339 006 26 E-mail: info@knf.com.cn www.knf.com.cn Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Tel. 0049 (0)7664 5909-0 Fax 0049 (0)7664 5909-99 E-mail: info@knf.de www.knf.de France, Morocco, Algeria KNF Neuberger 4, Bld. d Alsace Z.I. F-68128 Village-Neuf Tel. 0033 (0)389 70 35 00 Fax 0033 (0)389 69 92 52 E-mail: info@knf.fr www.knf.fr KNF worldwide Great Britain KNF Neuberger U.K. Ltd. Avenue 2 Station Lane Industrial Estate Witney Oxon OX28 4FA Tel. 0044 (0)1993 77 83 73 Fax 0044 (0)1993 77 51 48 E-mail: info@knf.co.uk www.knf.co.uk India KNF Pumps + Systems (India) Pvt. Ltd. RAJIV GANDHI INFOTECH PARK Phase 1 Ganga Estate, Survey No. 152/2/2 Above AXIS BANK Hinjewadi Pune 411 057 Tel. 0091 (0)20 640 13 923 0091 (0)20 640 08 923 Fax 0091 (0)20 229 33 923 E-mail: info@knfpumps.in www.knfpumps.in Italy KNF ITALIA S.r.l. Via Flumendosa, 10 I-20132 Milano Tel. 0039 02 27 20 38 60 Fax 0039 02 27 20 38 48 E-mail: info@knf.it www.knf.it Japan KNF Japan Co.Ltd. Across Shinkawa Bldg. Annex 3F 1-16-14 Shinkawa, Chuo-ku, Tokyo, Japan 104-0033 Tel. 0081 (0)3 3551-7931 Fax 0081 (0)3 3551-7932 E-mail: info@knf.co.jp www.knf.co.jp Korea KNF Neuberger Ltd. Woosan Bldg.RM#202, 336-4, Hwikyung-Dong Dongdaemun-Ku., 130-090, Seoul Tel. 0082 (0)2 959-0255/6 Fax 0082 (0)2 959-0254 E-mail: knf@knfkorea.com www.knfkorea.com KNF product centres Sweden, Denmark, Finland, Norway KNF Neuberger AB Mejerivägen 4, P.O. Box 44060 SE-10073 Stockholm Tel. 0046 (0) 87445113 Fax 0046 (0) 87445117 E-mail: info@knf.se www.knf.se Switzerland Sales KNF Neuberger AG Stockenstrasse 6 CH-8362 Balterswil Tel. 0041 (0)71 973 993 0 Fax 0041 (0)71 973 993 1 E-mail: knf@knf.ch www.knf.ch Taiwan KNF Neuberger Ltd. 9-2 FL., No., 24, Lane 123, Section 6, Ming Chuan East Road Taipei City, Taiwan Tel. 00886-2-2794-1011 Fax 00886-2-8792-1648 E-mail: knftwn@knftwn.com.tw www.knftwn.com.tw USA, Canada, South America KNF NEUBERGER, INC. Two Black Forest Road Trenton, New Jersey 08691-1810 Tel. 001 (609) 890 86 00 Fax 001 (609) 890 83 23 E-mail: knfusa@knf.com www.knfusa.com South America Direct Phone: 001 609 649 1010 E-mail: gb@knf.com Product centre for gas pumps: Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Phone 0049(0)7664 5909-0 Fax 0049(0)7664 5909-99 E-mail: info@knf.de www.knf.de Product centre for fluid pumps: Switzerland KNF FLODOS AG Wassermatte 2 CH-6210 Sursee Phone 0041(0)41 925 00 25 Fax 0041(0)41 925 00 35 E-mail: info@knf-flodos.ch www.knf-flodos.ch Product centre for micro pumps: Switzerland KNF Micro AG Zelglimatte 1b CH-6260 Reiden Tel. 0041(0)62 787 88 88 Fax 0041(0)62 787 88 99 E-mail: info@knf-micro.ch www.knf-micro.ch