Ten-year Plan. Figure 1 and Table 1. Each of the facilities shown in the plan is described in greater depth in the last appendix of this report.

Similar documents
Transmission Planning Report

Process Timeline. Area Bubbles. Legend. Problem Area that have been resolved. Recurring Areas from previous System Assessment.

Avista BPA, IPCO, PAC Project identified as long term need. Project Committed under Network Open Season. Plan of Service Determined

2013 Biennial Transmission Expansion Plan

Public Review Draft. June 30, System Assessment

2015 System Assessment

Transmission Planning. WECC 2014 Progress Report. March 14, 2014

2013 ANNUAL PROGRESS REPORT

Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers

2013 ANNUAL PROGRESS REPORT

PSE Attachment K Puget Sound Area Transmission Meeting

Cross Cascades North Study Team Report

Chapter 7: Transmission

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA PACIFICORP. Direct Testimony of Richard A. Vail

REDACTED. Eastside Needs Assessment Report Transmission System King County. Redacted Draft. October 2013 Puget Sound Energy

Update to the 2004 Puget Sound Area Study Group ( PSASG ) Report: Assessment of Puget Sound Area / Northern Intertie Curtailment Risk

Generation Interconnection Impact Study Results for Eurus Energy America Corporation s Eurus Combine Hills I, LLC Power Project.

Attached is Idaho Power s 2013 WECC Annual Progress Report. Please contact me if you have any questions.

System Impact Study for. Puget Sound Energy s Share of Frederickson I Generation Project. Pierce County, WA

Final System Impact Study for. Sierra Pacific Industries 31 MW Generation Project. Mount Vernon, WA. November 16, 2006

Appendix D Black Hills Project Summary

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1

Oilseeds and Biofuels in Washington State, 2017

THE NECESSITY OF THE 500 KV SYSTEM IN NWE S TRANSMISSION SYSTEM TO MAINTAIN RELIABLE SERVICE TO MONTANA CUSTOMERS

Alternatives for meeting the need for transmission improvement described

Final System Impact Study for. Horizon Wind Wild Horse Wind Plant Generation Project. Kittitas County, WA

Date: March 15, Mr. Enoch Davies WECC Technical Staff 155 North 400 West, Suite 200 Salt Lake City, Utah

Vantage to Pomona Heights Transmission Project Frequently asked questions

Attending Meeting (has not voted) Advance Bylaw Ballot

Black Hills Project Summary

Designated Network Loads and Resources Load Served by Company Owned Resources

Gateway South Transmission Project

Craig Quist Craig Quist

North Oregon Coast Area Study. Adam Lint

Consulting Agreement Study. Completed for Transmission Customer

Midway/Monument Area TTC Study

Generator Interconnection Applications

BC Hydro System 2011 Annual Progress Report

WECC Regional Planning Review. Canada/Pacific Northwest Northern California Transmission Line Project. Technical Analysis Committee Report

2016 PSRC REGIONAL & KING COUNTYWIDE EASTSIDE FUNDING AWARDS. Eastside Transportation Partnership September 9, 2016

Rocky Mountain Power Five Year Study Findings & Kick Off Meeting

West Station-West Cañon 115 kv Transmission Project

Large Load Serving Study Report for La Plata Electric Association, Inc. Alternatives. Addendum. San Juan Major Project

Status of PNM s Completed Transmission Construction Projects 11/30/2017

Pacific Gas and Electric Company s Revised 2015 Annual Progress

Wyoming Energy Projects

Memorandum. This memorandum requires Board action. EXECUTIVE SUMMARY

Local Transmission Plan

NorthernLights HVDC Project

Sub Regional RTEP Committee - Southern. August 19, 2011

Falcon-Midway 115 kv Line Uprate Project Report

South Dakota 890 Study

Generation Interconnection Request Queue = Denotes Inactive Requests

WA Plug-in Electric Vehicle Update through December 2018

Joint Con Edison LIPA Offshore Wind Power Integration Project Feasibility Assessment

TransWest Express AC and DC Project Comprehensive Progress Report (CPR) 3,000 MW DC and 1,500 MW AC WECC Phase 1 Analysis

Project Development & Construction Methods TADP 544

Pacific Gas and Electric Company s 2013 Annual Progress Report

Transmission Coordination and Planning Committee 2014 Q4 Stakeholder Meeting. December 18, 2014

Transmission Planning & Engineering P.O. Box MS 3259 Phoenix, Arizona

Distribution System Efficiency Potential & Conservation Voltage Reduction

2018 Annual Progress Report to WECC Pacific Gas and Electric Company

TransWest Express Transmission AC and DC Project Interregional Transmission Project Submittal

PSCo 10-Year Transmission Plan/20-Year Scenario Assessment

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC

2015 CPS2 Bounds (Effective June 15, 2015)

March 7, Subject: Southern California Edison 2011 Annual Progress Report

SPS Planning Criteria and Study Methodology

15 Nelson-Marlborough Regional Plan

Outer Metro 115 kv Transmission Development Study. (Scott Co, Carver Co and Hennepin Co)

15 Nelson-Marlborough Regional Plan

First Energy Generator Deactivation Request - January Deactivation Study Results and Required Upgrades April 25, 2012

Public Service Company of Colorado Transmission Projects Status. CCPG August 18, 2016

Western Area Power Administration Rocky Mountain Region Annual Progress Report. Projects. Weld Substation Stage 04

Local Transmission Plan. October 11, 2013 Revised August 25, 2014

PUD ELECTRIC SYSTEM INTERCONNECTION

GETTING THE WIND TO MARKET: KEY TO SUCCESS. IDAHO WIND WORKING GROUP Boise, Idaho September 22, 2010

Key to Status Fields in the Project List

100 MW Wind Generation Project

Preliminary Plan of Development

APPENDIX F: 2012 Request Window Submittals

Industrial & Datacomm Solutions from

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Harry Allen to Eldorado 2015

Tri-State December 2013 Board Meeting

TOT1A: Metering Point Relocation Comprehensive Progress Report (WECC Path 30)

Case 13-M Edic to New Scotland 345 kv Transmission Line and Hurley Avenue PARs Project (ED-NS/HA) Article VII Filing ED-NS/HA

Interconnection System Impact Study Report Request # GI

UNITED STATES DEPARTMENT OF AGRICULTURE. Compilation of Statistical Material. Pacific Northwest Federal Milk Marketing Order. Federal Order No.

A Better Transit Plan

National Grid s 2017 Local Transmission Plan

Pacific Gas and Electric Company s Revised 2016 Annual Progress

2018 CG Transient Stability and MOD 33 Updates

TransWest Express Project

BC Hydro System 2017 Annual Progress Report

Minnesota Biennial Transmission. Zone Meeting 8

OCTOBER 17, Emera Maine Representative: Jeffrey Fenn, P.E., LR/SGC Engineering LLC

WA Plug-in Electric Vehicle Update through December 2017

PRESENTATION BY ENERGY COMMISSION OF GHANA ON TACKLING POWER SYSTEM LOSSES

2017 Estimated Rifle Buck Deer Harvest by Zone,Wildlife Management Unit and Hunt, based on Mandatory Harvest Survey Reports. Seas Type Zone Unit Name

South Carolina Electric and Gas Company Planned Transmission Projects $2M and above Total 5 Year Budget

Transcription:

Ten-year Plan As a result of the analysis completed for the 2009 System Assessment, the follow-up sensitivity studies, analysis completed by the study teams, and individual planning participant studies, the following facilities are considered to be committed projects that are being built or are in the project design and siting processes. These projects comprise the ColumbiaGrid Ten-year Transmission Plan. This plan will be coordinated with other subregions (e.g., Northern Tier Transmission Group) and with the overall region through the Western Electricity Coordination Council. During 2010 and 2011, the WECC will be developing an overall plan for the western interconnection. The ColumbiaGrid ten-year plan will be part of the foundation for the overall WECC plan. Figure 1 and Table 1 Each of the facilities shown in the plan is described in greater depth in the last appendix of this report. Most of these plans are expected to be implemented in the five-year planning horizon. There are several other planning needs that have been identified in the five to ten year planning horizon and they are identified below. These transmission needs do not have firm projects at this time since there is sufficient time to study these areas and develop projects to resolve those needs. As the projects mature and become committed plans, they will be incorporated into the ColumbiaGrid Ten-year Plan. Long term needs in the ColumbiaGrid Planning area 1. West of Cascades North and South Several projects have been identified to reinforce these two paths to meet load growth and transfer eastside resources to the west side load areas. These projects include: a. IP line is planning to upgrade its line between Kittitas and Lake Tradition Substations to increase cross cascades north capacity. b. Series capacitors at Schultz - Bonneville is looking at additional series capacitors on the Schultz-Raver #3 and #4 500 kv lines to increase cross cascades north capacity. c. A new cross cascades 500 kv line into the area - If the smaller reinforcements listed above are insufficient, an additional 500 kv line may be needed across the northern cascades. d. Station K - Additional capacity on the west of cascades south path could be obtained by the development of a new substation Maupin area in central Oregon and the addition of series capacitors. e. Portland General Electric s Cascade Crossing Project This project includes a Boardman-Juniper Flats-Bethell 500 kv line into the Salem area. 2. Colstrip Upgrades

Series capacitor additions and other additions are being considered to upgrade the Montana to Northwest path. 3. Area Reinforcements Several projects are being considered in the North area to reduce PSANI curtailments. Some of these projects include: a. North King County Capacity Increase A 230 kv line between Sammamish substation in north King County and Talbot Substation in central King County is planned to support growing loads in that area and to increase the capacity of the Monroe-Echo Lake cutplane. 4. Pearl-Sherwood Upgrades Bonneville and Portland General Electric are planning to separate the terminations for the existing Pearl-Sherwood 230 kv lines to provide additional capacity during outages to meet load growth in the southwest Portland area. 5. Shelton-Fairmount-Port Angeles support A new 60 mile 230 kv line from Shelton to Fairmount is envisioned by Bonneville to support the Port Angeles/Port Townsend area of the Olympic Peninsula to meet growing loads. 6. North Downtown Seattle Seattle City Light is planning a new substation in the area north of downtown Seattle to serve load growth. This project would involve the installation of underground 230kV transmission lines from East Pine and Massachusetts Substations to a new Substation with a 230kV/115 kv autotransformer. The project construction would also include new 115kV transmission lines from Canal and Broad Street Substations to New Substation. This project was studied last year and approved by the ColumbiaGrid Board but load growth in the area has subsided and the project was delayed. 7. Lakeside 230/115 kv transformer is planning a 230/115 kv transformer at Lakeside Substation in the Bellevue Washington area. If a Lakeside transformer is added in place of the Lake Tradition bank, a Lake Tradition transformer will be needed in the longer planning horizon. 8. Mid Columbia Area Reinforcement Phase 2 Grant County PUD is contemplating additional reinforcement between Wanapum and Midway 230 kv substations in central Washington. 9. Spokane Area 230 kv Reinforcement Additional transformation is envisioned by Avista at Sunset Substation with new 230 kv lines to Westside, Beacon and/or Boulder substations in south Spokane to meet growing loads. 10. Moscow Transformer Additions An increase of transformer capacity in the Moscow, Idaho area is needed to meet growing Avista loads. 11. Lewiston Reinforcements A second Lolo-Hatwai 230 kv line is one solution to increase capacity for Avista load growth and operational flexibility. 12. Walla Walla-Wallula 230 kv line

This project may be needed by PacifiCorp in the future for transmission service requests for wind generation. 13. Springerville-Horizon 230 kv line A new 230 kv line from the Trojan-St. Mary s line is planned by Portland General Electric to meet growing loads in the west Portland area. 14. Chemawa 230/115 transformer additions Additional transformation is envisioned in the north Salem area to meet growing Bonneville loads. 15. Blue Lake-Gresham 230 kv line Portland General Electric is planning this project, or an alternative, to provide support for load growth in the east Portland area. 16. Kalama A new 230 kv line from Kalama to Longview is being studied by Cowlitz PUD to connect a 680 MW gas turbine to the system and provide for load growth in the area. 17. Trojan-Horizon 230 kv line This new line would provide additional capacity on the South of Allston path and help move Beaver and Port Westward generation to Portland General Electric loads in the west Portland area. 18. Pilot Butte area transformation A 500/230 kv transformer addition is being investigated by Bonneville in the Ponderosa/Pilot Butte area to meet growing loads in the Bend/Redmond area in central Oregon. 19. Additional 500/230 kv transformation in South area Limitations in 500/230 KV transformation in the south Area will require additional transformation, possibly at Maple Valley, Covington, Tacoma or Olympia. Depending upon the location selected, additional transmission lines may also be required.

Project Name Sponsor Date Olympic Peninsula Reinforcement (Satsop-Shelton 230 kv line) Bonneville Power 2009 Libby - Troy 115 kv line rebuild Bonneville Power 2009 Rogue SVC (South Oregon Coast) Bonneville Power 2009 Mid Columbia Area Reinforcement (Vantage - Midway 230 kv line upgrade) Bonneville Power 2011 Second 230/115 kv transformer at Redmond Bonneville Power 2011 Sandpiper Substation connecting into the existing Ashe - Marion 500 kv line and the new McNary - John Day 500 kv line Bonneville Power Bakeoven Series Capacitors plus other shunt caps and line upgrades (COI Upgrade) Bonneville Power John Day - McNary 500 kv Line Bonneville Power 2013 Big Eddy - Knight (formerly Station Z) 500 kv line looping into the new Knight Substation on the existing Wautoma - Ostrander 500 kv line Central Ferry - Lower Monumental 500 kv line and connection to existing Lower Granite - Lower Monumental 500 kv lines at the new Central Ferry Substation Castle Rock - Troutdale 500 kv line (I-5 Corridor Reinforcement Project) connected to the Paul-Allston line at the new Castle Rock Substation Bonneville Power 2013 Bonneville Power 2013 Bonneville Power 2015 Lower Valley Reinforcement (SE Idaho) Bonneville Power/others 2010 Retermination of lines into Andrew York Substation Chelan 2010 Relocation/upgrade of the McKenzie - Wenatchee Tap 115 kv line Chelan Wenatchee-McKenzie 115 kv line uprate from 50-75 degree C Chelan 2011 Cowlitz PUD conversion from 69 kv to 115 kv (Longview - Cowlitz #2, Longview - Lexington #2, Longview - Lexington - Cardwell) Cowlitz PUD 2011-2014 Rapids - South Nile 115 kv line Douglas 2010 Douglas - Rapids 230 kv line and Rapids 230/115 kv substation Douglas 2013 Columbia - Larson 230 kv line Grant 2014 Hemingway - Boardman 500 kv line Idaho Power 2015 Vantage - Pomona Heights 230 kv line (Yakima area) PacifiCorp

New Lookingglass Substation on the Reston - Dixonville 230 kv line (Albany area) Parish Gap 230/115 kv substation connecting to Bethel - Fry 230 kv line (Albany area) PacifiCorp <2013 PacifiCorp Wallula-McNary 230kV line PacifiCorp White City 230/115 kv transformer addition (Medford) PacifiCorp Keeler - Horizon 230 kv line with 230/115 kv transformers at Horizon South of Sedro Capacity Increase (Sedro - Horse Ranch 230 kv line) Portland General Electric 2010 230/115 kv transformer at Alderton Substation in south area 2011 Thurston County Transformer Capacity (St. Claire Substation ) Lake Tradition 230/115 kv transformer fed via Maple Valley - Sammamish 230 kv line 230/115 kv transformer addition at Sedro Woolley Substation (#2) in north area 2013 Beverly Park 230-115kV transformer (North ) Snohomish PUD Cowlitz 230 kv transformer replacement (second bank, Tacoma) Tacoma Power 2011 Canyon Substation (Tacoma area) Tacoma Power 2011 Rapids - Columbia 230 kv line (Mid-Columbia area) undetermined 2013