CRYSTALVUE PUBLIC VIEW DISPLAY (PVD) FEED THROUGH MOUNTS

Similar documents
DESIGNER SERIES HOUSINGS

EXTRA LARGE OUTDOOR HOUSINGS

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

US - 120V Models. Knowledge Base FUSES

FC-27W 7 dome housing. Installation Instructions

Track Light with Monitor Installation Guide

IP54 Gasket Kit VGA-IP54K-IC VGA-IP54K-IC78. Installation Guide

Rack Mount Power Supplies

In-ceiling mount NDA-FMT-DOME. en Installation manual

FlexiDomeHD 1080p Mounts VDA-832FHD-WMT VDA-832FHD-PMT. Installation manual

High-Lift Wheel Dolly Max. Capacity: 1,500 lbs. (681 kg)

AD1240 Champion Series Outdoor, Medium Duty Pan/Tilt

INSTALLATION INSTRUCTIONS Horizontal Array Pole Clamp Models: KTA-220/225 and KTA-320/325

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

CCTV Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

HeAvy duty JAck stands

INSTALLATION and MAINTENANCE INSTRUCTIONS SHO SERIES ELECTRIC CABLE REELS

(31 ) ZEON CONTROL PACK RELOCATION KIT

P1600 CCTV Standard Steel Pole. Installation and Operation Instructions for the following model: Standard 16 Steel Pole.

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

The Da-Lite Difference.

SMP3CTX Series Power Supply/Charger

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

DC CCTV Power Supplies Installation Guide

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

GETTING STARTED WITH IN-WALL DIMMER SWITCH

PD-1 POWER DISTRIBUTION UNIT

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

Materials List: Tools List:

PM - Projector Mount System

T832 T842 ELECTRIC MOTOR OPTION ASSEMBLY MANUAL. Read & understand all instructions pertaining to this option prior to use!

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Sivoia QS Wireless Drapery Lite System

ELITE HEAVY-DUTY BACK

EA5506. Electrically Actuated Carbon Steel PN16 Ball Valve. Description

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

Instruction Book for. ContouR ElECtRol

12-Inch Hybrid Fiber Access Terminal Installation Instructions

Service Jacks. No. 1503A Max. Capacity: 2-1/2 Tons No. 1504A Max. Capacity: 3 Tons. Service Jack Item List

HLS Watt Halogen Illuminator Service Manual

FULL HEIGHT ALUMINUM TURNSTILE DOUBLE UNIT AT-FAL SERIES I N STALLATION AND O P E RATING I N STRUCTIONS

WARNING. Important Notice

202 Schwinn Recumbent Exercise Bike

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

C35 Mobius Floor Lamp & C Page 1 of 7

INSTALLATION INSTRUCTIONS Small Flat Panel Extreme Pitch Mechanism Model: FSA-1006

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Asepsis 21 Delivery Unit

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

Woda-Sci System Installation Parts Set

Installing the Switch Chassis

INSTALLATION INSTRUCTIONS

SPACESAVER EC-300 A ELECTRICS

Plasma Display Electric Ceiling Lifts

TRAVEL'R DIRECT RESPONSE

A100 Class D 100W Subwoofer Amplifier. User Guide VOLUME POWER BOOST

240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company.

Operating Instructions

INSTRUCTION BOOK FOR. Dual Masking Electrol

Vehicle Lift System Max. Capacity: 10 Tons (Pair) at 150 PSI

(31 ) ZEON CONTROL PACK RELOCATION KIT

OEM TM-50 Quick Start Guide

WLP Series Wall Mounts (WLP Series Low Profile Wall Mount Enclosure) Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Installation manual 2 Leveling kit GM x 4. Part # Part # Important customer information: GM x 4

OLYMPIAN MODEL 740 Operation and Service Manual

920 Remote Control Switches

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

Installation Instructions

Portable Pack USER MANUAL

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

Powerware Vdc Extended Battery Cabinet User s Guide.

dans un panneau de distribution NQ Instruction Bulletin Boletín de instrucciones Directives d'utilisation

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

ibusway for Data Center

I-BFV.KIT Butterfly Valve Gear Operator Replacement

ECO# 1801 REVISION# 000 ES DATE

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Fiber optic splice closure

Rollstar Shade Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

TJ lb Capacity Trailer Jack. 2-in-1 Combo With Swing Back Design. Assembly & Operating Instructions

INSTALLATION INSTRUCTIONS HYLYTR WALL GRAZER

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

B o d y S t r u c t u r e

UNIVERSAL SOLAR SYSTEM (USS) USER MANUAL. For Millennium Low Power Gas Detectors or other continuous loads less than 0.

Trailer Jack. Model Assembly and Operating Instructions

M Remote Mounting Kit

BEFCO. Operator s Manual BABY HOP & HOP FERTILIZER SPREADERS ACCESSORIES SIDE ROW DISCHARGE. AA4-120 (fits models Hop 209 & 212) DEFLECTOR

/2017. Swing sink clamping element double-acting

INSTALLATION INSTRUCTIONS

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Owner s Manual. Model Air Conditioning Component Flusher

Transcription:

ø 5.0 CRYSTALVUE PUBLIC VIEW DISPLAY (PVD) FEED THROUGH MOUNTS After attaching Pipe Extension End to Threaded Pipe (not provided) tighten this set screw to secure. Pipe Extension End VESA Plate End Attach to monitor Thumbnuts (X4) allow the monitor to Adjust (up to 180º horizontal). ø2.25 Mounting Screws10-24x3/8 BHC SS patch lock screws (X4) Washers (X4) 75 and 100mm Standard VESA Plate Pattern Loosen the Thumbnuts to position, tighten to secure. FEED THROUGH MOUNT SERIES 7.0 9.3 VESA Plate View I NSTALLATION AND 2.3 O PERATING I NSTRUCTIONS W WW. AIGISMECH. C OM

SAFETY PRECAUTIONS The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. SECURITE Le point d'exclamation à l'intérieur d'un triangle équilatéral avertit l'utilisateur de la présence d'instructions importantes d'utilisation et de maintenance dans la documentation accompagnant l'appareil. SICHERHEITSVORKENHRUNGEN Das Ausrufezeichen in dem gleichseitigen Dreieck ist dazu da, den Benutzer auf wich-tige Inbetriebnahme- und Instandhaltungs-vorschriften hinzuweisen, die dem Gerät in Form einer Broschüre beigelegt sind. PRECAUCIONES DE SEGURIDAD El símbolo de exclamación dentro de un triángulo equilátero, se muestra con el objetivo de alertar al ususario de que instrucciones de operación y mantenimiento importantes acompañan al equipo. 1 UNPACKING Unpack carefully. Check for the following items: Verify the unit model number. Verify that parts shown below have been included. 1.1 MTFPF12F- 1 MTFPF12F- Mount 1 VESA Hardware Kit 4 10-24x3/8 BHC SS patch lock screws 4 washers 1.2 MTFPF10P- 1 MTFPF10P- Mount 1 VESA Hardware Kit 4 10-24x3/8 BHC SS patch lock screws 4 washers 1.3 MTFP3F10P- 1 MTFP3F10P- Mount 1 VESA Hardware Kit 4 10-24x3/8 BHC SS patch lock screws 4 washers If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. If any items are missing, notify Aigis Mechtronics. The shipping carton is the safest container in which the unit may be transported. Save it for possible future use. 2

2 SERVICE If the unit ever needs repair service contact Aigis Mechtronics. 3 DESCRIPTION The feed through mount series is designed to permit the installation of the CrystalVue Public View Display to a wall or threaded pipe.these mounts are capable of supporting the total weight of equipment installed.the maximum load carrying capacity for the MTPFPF12F- and the MTFPF10P- is 25lbs.The maximum load carrying capacity for the MTFP3F10P- is 45lbs. 4 INSTALLATION Attention: Installation should be performed by qualified service personnel only in accordance with applicable local codes. CAUTION: Do not exceed the Maximum Rated Load for the particular mount used. 4.1 Mounting MTFPF12F- 1. Feed the cables, from the back of the monitor, through the center hole of the VESA plate. 2. Mount VESA plate end of the MTFPF12F- to the monitor using the screws provided in the hardware kit. 3. Mount the flange end of the MTFPF12F- to the wall using the appropriate fasteners (not provided). Note: It is recommended to use four (4) 3/8 bolts. 4. Make necessary adjustments to the pole and secure using the three (3) set screws. 5. Adjust the monitor to the desired position and secure using the four (4) thumbnuts. See Figure 1. 90º Rotation Rotate pole to desired position and secure with set screws (x3). Flange End Attach to Wall After installing the 10-24x3/8 BHC SS monitor to the VESA Plate. patch lock screw (X4) Adjust (up to 180º horizontal) and washers (X4) to desired position. Secure with the four thumbnuts. Thumbnuts (4) 75 and 100mm Standard VESA Plate Pattern VESA Plate End Attach to monitor (4X) Ø.41 Typ 90º Apart Eq. Spaced On Ø4.000 B.C Flange End Veiw VESA Plate View Figure 1: Mounting the MTFPF12F- 3

4.2 Mounting the MTFPF10P- & the MTFP3F10P- 4.2.1 Components of the MTFPF10P- and the MTFP3F10P- 1. The MTFPF10P- and the MTFP3F10P- are feed-thru mounting systems designed to mount the CrystalVue Public View Display (PVD) in combination with a 1 1/2 threaded pipe (A). 2. The MTFPF10P- series is designed to mount monitors between 20 and 26 inches in diameter. 3. The MTFP3F10P- is designed to work with larger monitors between 32 and 37 inches in diameter. 4. The main difference between the two mounts is the size of the stabilizing plate (D). 5. Both mounts use a standard VESA hole pattern (D1) but the stabilizing plate of the MTFPF10P- measures 3 X 3 square while the MTFP3F10P- measures 6 X 6 square. For exact dimensions see the section Dimensional Outlines at the back of this book. 6. Both the MTFPF10P- and the MTFP3F10P- have a prethreaded coupler (B) installed to allow a 1 1/2 threaded pipe to attach seamlessly to the mount. 7. The threaded stem (C) and ball shank (E) rotate to change the orientation of PVD Screen and can be easily adjusted using the thumbnuts (F) located on the back of the mount. 8. If the Aigis part number PIPE-KIT-48 (purchased separately) will be used with either of these mounts remove the coupler (B) before installation. A 1 1/2" Threaded Pipe (not provided) Set Screw B Threaded Coupler Coupler is shown detached for clarity, there is no need to detach or remove when using a standard 1 1/2" threaded pipe. Set Screw C Threaded Stem Note: Remove Coupler from the stem if using Aigis Pipe Kit. Part # PIPE-KIT-48 or PVD-MK -Truss or PVD-MK Ceiling F E Thumbnuts (X4) allow the monitor to Adjust (up to 180º horizontal). Rotating Ball Shank Loosen the Thumbnuts to position, tighten to secure. Stabilizing Plate Detail D Stabilizing Plate End Attach to monitor Standard VESA Plate Hole Pattern 75 and 100mm D1 Mounting Screws10-24x3/8 BHC SS patch lock screws (X4) Washers (X4) Screw holes for Mounting up to (X6) 10-24x1/2"BHC SS patch lock screws and (X6) Washers Components of the MTFPF10P- and the MTFP3F10P- 4

4.2.2 Pipe Mount Descriptions To ensure the proper installation, the mounting process has been broken down into two separate sections. Please read the descriptions below and use the section that pertains to the type of pipe being used. Section 4.2.3 will explain installations utilizing a pipe that can be freely rotated during the mounting process.this allows for the pipe to be rotated clockwise to fit into the coupler and NOT by rotating the mount attached to the monitor. Section 4.2.4 will explain installations using a pipe that is fixed or stationary (unable to rotate) during the mounting process. 4.2.3 Mounting to a Freely Rotating Pipe to recording device 1. Begin by first loosening the four (4) thumbnuts to allow the coupler and ball shank to rotate freely. 2. Tilt the coupler approximately 30º to allow the leads to feed through from the monitor. 3. Feed the leads from the back of the PVD into the middle of the stabilizing plate hole; then thread through the mount. Pull the leads through the top of the coupler leaving six inches of wire and cabling exposed. 4. Connect one (1) grey Wago clamp to the end of each power lead. 5. It may be necessary to temporarily tape the leads to the top of the coupler to secure the leads from slipping back through the mount. 30º 5 4 Coax BNC 1 2 to power supply from monitor 3 24 VAC power leads 1 6. Rotate the coupler end to the 12 o clock position.then tighten the thumbnuts. 6 7. Attach the stabilizing plate to the CrystalVue PVD using the four (4) screws and four (4) washers provided in the hardware kit.tighten securely. 8. Tighten the set screw to secure. 8 7 5 Stabilizing Plate detail

9 9. Feed the external power wires from the power supply and the Coax BNC (if used) down through the pipe. Leave at least 6 inches of the power and 12 inches of the BNC cable exposed. Stagger the length of the power wires by stripping the outer jacket back 4-inches. Cut one lead 2-inches. Strip the ends of each lead 3/8-inch to 1/2- inch to allow for connections. 10. Remove the tape from the cables on the PVD. Connect the power leads from the pipe to the unused end of each wago connector from the PVD. Connect the coax BNC connector (if used). 11. Tie all the leads together near the wago connectors.this will allow for them to easily slide up through the pipe and not become disconnected. 11 10 rotate the PIPE clockwise 12. Turn the PIPE (NOT the PVD), into the threaded coupler by turning clockwise. DO NOT rotate the PVD unit. 12 13 12 13. Tighten the set screw to secure the coupler to the threaded pipe. 14. Adjust the monitor to the desired position and secure using the four (4) thumbnuts. 14 6

4.2.4 Mounting to a Stationary Pipe Mount 1. Remove the four (4) thumbnuts and washers from the back of the stabilizing plate. 2. Separate the back cap from the stabilizing plate to expose the ball shank. Set aside the thumbnuts, washers and back cap. 3. Remove the ball shank and coupler from the stabilizing plate. 1 3 2 4. Feed the power wires from the power supply and the Coax BNC cable (if used) through the Pipe. Leave 10-inches of the power cables exposed, leave 15- inches of the BNC cable hanging from the end of the pipe. Stagger the length of the power wires by stripping the outer jacket back 4-inches. Cut one lead 2-inches. Strip the ends of each lead 3/8-inch to 1/2-inch to allow for connections. 5. Connect one (1) grey Wago clamp to the end of each power lead. 4 5 6. Rotate the coupler onto the threaded pipe and tighten the top set screw to secure. 6 7

7. Feed the Power wires and the BNC Coax from the PVD through the hole in the stabilizing plate. 7 Stabilizing Plate Attached to PVD 8. Attach the stabilizing plate to the CrystalVue PVD using the four (4) screws and four (4) washers provided in the hardware kit.tighten securely. 8 Note:To connect the wires it may require 2 people to complete this step. Have one person hold the PVD while the other makes the connections. 9. To make the wire and cable connections hold the PVD up to the wires coming from the pipe. Connect the power wires from the PVD to the unused end of the Wago connector from the pipe. Connect the male and female ends the BNC coax (if used). 10. Tie all the leads together near the wago connectors.this will allow for them to easily slide up through the pipe and not become disconnected. Push the excess wires into the pipe. 10 9 8

11. Re-attach the back cap, washers and thumbnuts to the stabilizing plate.tighten the thumbnuts enough to allow the PVD to stabilize but still allowing movement for adjustments to the orientation of the screen for maximum viewing. 12. Additional position adjustments are made by loosening the bottom set screw to rotate the monitor up to 180º. 13. Tighten the bottom set screw and the four (4) thumbnuts after all adjustments are complete. 11 12 12 13 13 5 DIMENSIONAL OUTLINES ø 5.0 12.0 13.4 Dimensional Outline MTFPF12F- 9

ø2.25 7.0 9.3 2.3 Dimensional Outline MTFPF10P- 10

ø2.25 10.0 6 3 3.3 6 Dimensional Outline MTFP3F10P- 11

2005 Aigis Mechtronics 1124 Louise Road Winston-Salem, NC 27107 Tel: 336.785.7740 Fax: 336.785.7744 www.aigismech.com Data subject to change without notice 100 0137 002 AIG 11/06 Printed in U.S.A.