QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical terminal devices. This company is well equipped with testing apparatus to guarantee effective and sufficient quality control. Critical tests are able to be performed. Such tests include electro-mechanical, temperature rising, over current characteristics, residual current operation, power frequency withstand, voltage resistance to abnormal humidity and heating, resistance to mechanical impact and vibration and electric shock protection tests, etc. The manufacturer was accredited ISO 9002 in 1999 and ISO 9001:2000 in 2002. Test certificates from internationally recognised test laboratories to Australian/New Zealand standards can be supplied if requested for manufactured product. Product data sheets available on our website. Please see our website www.rteckpacific.com for all our latest imported product, sales and information details. LIABILITY STATEMENT All care and diligence has been used in processing, analysing and extracting the information contained in this document. Rteck Pacific Ltd accepts no liability for any errors which may inadvertently appear in the document. Rteck Pacific Ltd shall not be liable for any loss or damages suffered by customers upon the use directly or indirectly of information supplied herein.
ATLANTIS WEATHERPROOF ISOLATORS IDEAL FOR AIRCONDITIONING CONTROLS Check out our prices by asking your wholesaler Atlantis 20 amp front Atlantis 20 amp internal Atlantis 35 amp front Atlantis 35 amp internal The Atlantis series of weatherproof isolators is an economical switch range catering to air conditioning/heat pumps, spa/swimming pools and other suitable applications as per the IP56 specifications. Enclosure made from quality UV stable, durable and fire-resistant material with fitted neutral and earth connection bars. Top and bottom threaded cable entries and plenty of room inside helps with easy installation. Pad lockable for extra safety. Available in single and three pole configurations in 20 and 35 amps 230/415VAC 50Hz. Features Top cover secured with only 2 screws allowing for quality installation. Top cover and base sealed with heavy duty non-shrink rubber gasket. Threaded cable entries top and bottom sealed with rubber O rings. Fixed earth and neutral connection bar with double screws per terminal. All terminals accept cables up to 16mm. IP56 rating. Can be padlocked in the Off position for security purposes. Technical Specifications Code ATL 120 1 pole 20 amp 250 VAC 50 Hz surface mount switch 16 mm terminals M Rating 220 IP56 ATL 135 ATL 320 ATL 335 1 pole 35 amp 250 VAC 50 Hz surface mount switch 16 mm terminals M Rating 220 IP56 3 pole 20 amp 440 VAC 50 Hz surface mount switch 16 mm terminals M Rating 180 IP56 3 pole 35 amp 440 VAC 50 Hz surface mount switch 16 mm terminals M Rating 180 IP56
PRO-SERIES 1-32 TYPE MPCB GENERAL PRO-SERIES 1-32 type Motor Protection Circuit Breaker (MPCB) is applicable to AC electric circuit with frequency 50/60 Hz, rated voltage up to 690 V and rated current up to 32A. It protects against the overload, disconnection of phase and short-circuit of three-phase asynchronous motors, and it is suitable for unfrequently starting & breaking operations for the motor. It can also be used for electrical circuit protection, unfrequent load changeover and isolation. It provides the function of current rating adjustment to suit the motor. See our website for more details and technical information. Overall and mounting dimensioned chart
PRO-SERIES MINI CIRCUIT BREAKER GENERAL MCB is applicable to electric circuits with rated voltage 230/400 AC, frequency 50/60Hz and rated current up to 125Amp. The product provides protection against overload and short circuit to electric circuits and equipment for many applications - see individual specifications and product data sheets. MCB is also used as non-frequent chaneover of electric circuits. Special tips: 1. MCB is for non-professional operation by those untrained, and no maintenance is required. 2. Satisfying conditions and applications as mentioned above MCB with ON-OFF indicating device is considered suitable for isolation function. 3. Particular devices such as surge protective devices, surge arrester etc are recommended to install at upstream lin to MCB as precaution against potential surge voltage and current occurring at its power input side. 4. Appropriate tripping curve geing chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock. 5. B,C,D Tripping curve (see graphics 1) B curve: Instantaneous tripping current: 5In Instantaneous non-tripping current: 3In Application: provides protection to circuits with low inductive load C curve: Instantaneous tripping current: 10In Instantaneous non-tripping current: 5In Application: provides protection to circuits with inductive load or to highly inductive illumination system D curve: Instantaneous tripping current: 20In Instantaneous non-tripping current: 10In Application: provides protection to circuits with high inductive load or electric distribution system with high surge current. 6. Ambient temperature and current rating curve
PRO-SERIES MINI CIRCUIT BREAKER PRO-SERIES 19-63 (suitable for industrial applications) Standard: IEC60898 SPECIAL NOTE: Circuit breaker accessories used for remote control and signalling are available - see Rteck website.
PRO-SERIES MINI CIRCUIT BREAKER PRO-SERIES 21-63 Standard: IEC60898 SPECIAL NOTE: Circuit breaker accessories used for remote control and signalling are available - see Rteck website.
PRO-SERIES RESIDUAL CURRENT CIRCUIT BREAKER GENERAL RCCB is applicable to electric circuits with rated voltage 230/400 AC, frequency 50/60Hz and rated current up to 125Amp. The RCCB provides indirect protection to the operator s body under such condition that the exposed live parts should be connected to a proper earthing pole. The RCCB also provides protection against the fire danger caused by earth fault current due to function failure of over-current protection device. Special tips: 1. RCCB with rated sensitivity up to 30mA could be used as supplementary protecting device in case other protecting device fails its protection against electric shock. 2. RCCB designed for commercial installation and other similar application, is for non-professional operation, and no maintenance is required. 3. RCCB provides no protection against electric shock resulted from direct contacts of both protected lines, or leakage current between these two lines. 4. Particular devices such as surge protective devices, surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side. 5. Satisfying conditions and applications as mentioned above, RCCB with ON-OFF indicating device is considered suitable for isolation function.
PRO-SERIES RESIDUAL CURRENT CIRCUIT BREAKER PRO-SERIES 25-100 Standard: IEC61008
PRO-SERIES RESIDUAL CURRENT CIRCUIT BREAKER PRO-SERIES 3-32 Standard: IEC61008
PRO-SERIES RESIDUAL CURRENT CIRCUIT BREAKER PRO-SERIES 7-125 Standard: IEC61008
PRO-SERIES RESIDUAL CURRENT CIRCUIT BREAKER with Overcurrent Protection GENERAL RCBO is applicable to electric circuits with rated voltage 230V AC, frequency 50/60Hz and rated current up to 40Amp. The RCBO provides indirect protection to the operator s body under such situation that the exposed live parts should be connected to a prper earth pole. RCBO also provides overcurrent protection to circuits for commercial and industrial installations. Moreover, it prevents potential fire danger caused by earth fault current in case over-current protection device fails. Special tips: 1. RCBO with rated sensitivity up to 30mA could be used as supplementary protecting device in case other protecting device fails its protection against electric shock. 2. RCBO designed for commercial and industrial installations (see individual data sheets) is for nonprofessional operation, and no maintenance is required. 3. RCBO provides no protection against electric shock from direct contact of both protected lines, or leakage current between these two lines. 4. Particular devices such as surge protective devices, surge arrester etc are recommended to install at upstream line to RCBO as precaution against potential surge voltage and current occurring at its power input side. 5. Satisfying conditions and applications as mentioned above, RCBO with ON-OFF indicating device is considered suitable for isolation function. 6. RCBO overcurrent protection value is fixed and is not subject to further adjustment. PRO-SERIES 5-40 Standard: IEC61009-1
PRO-SERIES SWITCH-DISCONNECTORS PRO-SERIES 16-63 SWITCH-DISCONNECTOR Standard: IEC60947-3
PRO-SERIES SWITCH-DISCONNECTORS PRO-SERIES 16-125 SWITCH-DISCONNECTOR Standard: IEC60947-3
PRO-SERIES SWITCH-DISCONNECTORS PRO-SERIES 2-125 SWITCH-DISCONNECTOR Standard: IEC60947-3 (For industrial applications)
PRO-SERIES SWITCH-DISCONNECTORS PRO-SERIES 2-250 SWITCH-DISCONNECTOR Standard: IEC60947-3 (For industrial applications)
PRO-SERIES SWITCH-DISCONNECTORS PRO-SERIES 3 SWITCH-DISCONNECTOR Standard: IEC60947-3