Voltage. kva kw kva kw

Similar documents
kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

C U K U R O V A GENERATOR SYSTEMS

Perkins 404D-22G diesel engine Newage/Stamford BCI184E alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 670 P. Stand-by power: 670 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TAG2 diesel engine Newage/Stamford UCI274F alternator Standard Generator Features

GNS 1100 P. Stand-by power: 1100 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 630 V. Stand-by power: 630 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 400 V. Stand-by power: 400 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

GNS 500 V. Stand-by power: 500 kva. Diesel Generating Sets, made for Europe

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Volvo TAD941GE diesel engine Leroy Somer LSA 46.2 VL12 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

204 KW / 254 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

28 KW / 28 KVA POWERED by

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Perkins 4016TAG1A diesel engine Stamford PI734E alternator Standard Generator Features

130 KW / 165 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

55 KW / 70 KVA POWERED by

Perkins TWG2A diesel engine Newage/Stamford PI734B alternator Standard Generator Features

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

600 KW / 750 KVA POWERED by

64 KW / 80 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

30 KW / 40 KVA POWERED by

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

Perkins 2206A-E13TAG2 diesel engine Newage/Stamford HCI444E alternator Standard Generator Features

18 KW / 18 KVA POWERED by

Perkins TAG3A diesel engine Newage/Stamford PI734E alternator Standard Generator Features. Optional Features ISO ISO 9001:2000

2000 KW / 2500 KVA POWERED by

500 KW / 625 KVA POWERED by

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

UCDI224F - Technical Data Sheet

UCI224C - Technical Data Sheet

UCDI274J - Technical Data Sheet

UCDI224E - Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

UCI274H - Technical Data Sheet

UCI274C - Technical Data Sheet Winding 06

300 KW / 375 KVA POWERED by

PI736F - Winding 312. Technical Data Sheet

UCI224F - Technical Data Sheet

1000 KW / 1250 KVA POWERED by

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

BCI164C - Technical Data Sheet Winding 06

UCDI274K - Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

HCI634G - Technical Data Sheet

HCI 534C/544C - Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

HCI634V - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534E/544E - Technical Data Sheet

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

640 KW / 800 KVA POWERED by

Transcription:

Voltage 380-415 Standby* * kva kw kva kw 2496,8 1997,5 2250 1800 Amp 3251 Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply 10% overload power for a period of 1 hour in 12 hours operation as it is defined in ISO 3046. Standby Rating Applicable for supplying continuous power ar variable load in the event of a utility power failure and overload is not allowed as it is defined in ISO 8528-3. Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 16 cylinder, water cooled engine 52 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features Automatic load transfer panel Automatic syncronization and power sharing systems Soundproof canopy Container type enclosers Road trailer Job-site trailer Protection circuit breaker Air start Remote type radiator Base fuel tank External type fuel tank Automatic fuel transfer system Residential silencer Dimensions & Weight Open Type Sound Attenuated Dry Weigt kg Dry Weigt kg Length Length Width Width Height Height Tank Capacity L External Tank Capacity L External Technical Data Sheet 120508 - Page1

Engine Technical Data Cooling System Manufacturer PERKINS Type Tropical, heavy duty type Model 4016-61TRG3 Ambient temperature, C 52 Type 4 cycle, water-cooled Engine coolant capacity, Liters 95 Number of cylinders 16 Jacket coolant flow Liters/sec 21 Cylinder arrangement 60 Vee Displacement, Liters 61,123 Bore X Stroke, 160 X 190 Compression Ratio 13:1 Combustion System Direct injection Aspiration Turbocharge, air to water charge cooled Rotation Anticlockwise viewed on flywheel Two triple thermostats System designed for ambients up to 50ºC Lubrication System Gross engine power, kwb 1975 Fan Power, kwm 100 Type Pressurized BMEP gross, bar 28,85 Lub oil capacity sump min, Liters 157 Combustion air flow, m³ / min 160 Lub oil pressure, KPa 400 Exhaust gas temp.(after turbo), C 475 Wet sump with filler and dipstick Exhaust gas flow (after turbo),m³ / mi490 Full-flow spin-on oil filters Mean piston speed, m / s 9,5 Fuel System Fuel Consumption Type of injection system Fuel injection pump Fuel injector pressure, bar Delivery/hour at 1500rev/min, Lt Direct injection Combined unit injector 1400 1380 liters per hour Stand by Base Load %75 Load Fuel lift pump type Tuthill TCH 5 %50 Load Governing to Electronic governor to ISO 8528-5 %25 Load 2004 Direct fuel injection system with fuel lift pump grams per kwh Stand by Digital governing to ISO 8528-5 class G2 with isochronous capability Full-flow spin-on fuel oil filters Base Load %75 Load Electrical System %50 Load %25 Load Alternator 24 Volt with integral regulator Starter motor (DC) 24 Volt Starter motor power 16,4 kw Standby kw Model Turbine inlet temperature shutdown switch 24 volt starter motor and 24 volt alternator with integral Twin high coolant temperate shutdown switches Twin low oil pressure shutdown switches Air shut off valve wiring harness 528 L 473 L 373 L 346 L 235 L 127 L 209 g/kwh 205 g/kwh 200 g/kwh 200 g/kwh 204 g/kwh 220 g/kwh kw Gross Net Gross Net 4016-61TRG3 2183 2083 1975 1875 Technical Data Sheet 120508 - Page2

Alternator Technical Data Optional Equipment Manufacturer STAMFORD Winding and bearings RTD's Model PI734G Power Factor Controller Type 4-Poles, Rotating Field, Brushless Quadrature Droop kit for Parallel Operation power at rated voltage, kva 2200 Winding Protection Thermistors Efficiency, % 96 MX321 AVR with 0.5% Regulation and 3 phase sensing Power factor 0.8 Air filters Phase 3 Anti condensation heaters Frequency, Hz 50 Diode Failure Unit Speed, Rpm 1500 Excitation Loss Module Voltage, V 380/415 Manuel Voltage Regulator and Re-greased bearings Excitation Separately excited by P.M.G Stator windings 2/3 Pitch factor Regulation AVR, Auto Voltage Regulator Terminals&Terminal Box Voltage Regulator MX341 Voltage Regulation, % ± 1 Standard generators feature a main stator with 6 ends brought out to R.F.I Suppression BS EN 61000-6-2,BS EN 61000-6-4 the terminals, which are mounted on the frame at the non-drive end VDE0875G, VDE 0875N of the generator. A sheet steel terminal box contains the AVR and Waveform distortion No Load <1.5% Non distorting provides ample space for the customers wiring and gland balanced linear load <5.0% arrangements.it has removable panels for easy access. Rotor Dynamic balanced Overspeed, Rpm 2250 Short circuit current < 300% Shaft&Keys TIF Less than 50 Insultion class H All generator rotors are dynamically balanced to better than BS6861 Construction Single bearing, direct coupled :Part 1 Grade 2.5 for minimum vibration in operation. Two bearing Coupling Flexible generators are balanced with a half key. Stator winding Double layer concentric Connection WYE Insulation / Impregnation Protection class IP23 Cooling air volume,m³ / sec 2,69 The insulation system is class 'H' All wound components are impregnated with materials and Winding&Electrical Performance processes designed specifically to provide the high build required for static windings and the high mechanical strength required for All generator stators are wound to 2/3 pitch.this eliminates triplen rotating components. harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch Standards design avoid sexcessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully Newage Stamford industrial generators meet the requirements of BS connected damper winding reduces oscillations during paralelling. EN 60034 and the relevent section of other international standards such as This winding, with the 2/3 pitch and carefully selected pole and BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 tooth designs, ensures very low waveform distortion. Other standards and certifications can be considered on request Quaility Assurance Standby Model Generators are manufactured using production procedures having a quaility kva kw kva kw assurance level to BS EN ISO 9001. PI734G 2360 1888 2200 1760 Technical Data Sheet 120508 - Page3

Deepsea 7320 Control System Description Deepsea 7320 is an Auto Mains(Utility) Failure Control module. The module is used to monitor a mains supply and automaticlly start a standby generator set. The module can also monitor an extensive number of engine parameters and it can display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC and it also provides real time diagnostic facilities Specification DC SUPPLY Continuous Voltage Rating: 8 V to 35 V Maximum Operating Current: 340 ma at 12 V, 160 ma at 24 V Maximum Standby Current: 160 ma at 12 V, 80 ma at 24 V Charge Fail/Excitation Range: 0 V to 35 V MAINS(UTILITY) & GENERATOR Voltage Range: 15 V - 333 V AC (L-N) Frequency Range: 3,5 Hz to 75 Hz OUTPUTS Output A (Fuel): Output B (Start): Output C & D : Input Functions display on LCD 15 A DC at supply voltage 15 A DC at supply voltage 8 A 250 V (Volt free) Generator Volts Volts L1-N, L2-N, L3-N Generator Volts Volts L1-L2, L2-L3, L3-L1 Generator Amps Amps L1, L2, L3 Generator Frequency Hz Mains Volts Volts L1-N, L2-N, L3-N Mains Volts Volts L1-L2, L2-L3, L3-L1 Mains Frequency Hz Engine Speed RPM Plant Battery Volts Volts Engine Hours Run Hour Generator total power kva L1, L2, L3,total Generator total power kw L1, L2, L3,total Generator power factor Cosφ L1, L2, L3,total Features 4-Line back-lit LCD text display and five key menu navigation LED and LCD alarm indication 9 configurable inputs and 8 configurable outputs Configurable timers, alarms and event log (250) Fuel usage monitor and low fuel alarms Charge alternator failure alarm Manual speed and manual fuel pump control Engine exerciser and ''Protections disabled'' feature kw overload protection Power monitoring ( kw, h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and duy load outputs) Automatic load transfer and unbalanced load protection Independent Earth Fault trip Support for up to three remote display units and USB connectivity Configurable display languages Remote SCADA monitoring User selectable RS232 and RS485 counications SMS messaging ( external modem required) Additional display screens to help with modem diagnostics Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits Optional Input Functions Engine Oil pressure Fuel level Engine Temperature kpa % C Technical Data Sheet 120508 - Page4

Model Codes and General Information Kunz Diesel Generator KZ S 2250 P S Alternator Make-Stamford Engine Make-Perkins Rating - kva Stationary type KUNZ diesel generator Perkins 4000 Series Diesel Engine Newage / Stamford Alternator 4016 61 TR G 3 P I 73 4 G Power Level Genset Engine Turbocharged Remote Cooled Displacement 4000 Series, 16 cylinder Core Length Number of poles Shaft Height in cm Industrial Generator type Technical Data Sheet 120508 - Page5