USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Similar documents
USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

USER MANUAL. Uninterruptible power supply MODEL: 53965,

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

1. INTRODUCTION. Features:

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

General Precautions. Personnel Precautions

Uninterruptible Power Supply

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

CP900EPFCLCD User s Manual K

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

MM-AVR UPS Series User s Manual

USER MANUAL ONLINE UPS

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Uninterruptible Power System

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Eclipse Plus VA UPS and Surge Suppressor User s Manual

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

Limousin II User Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

PR1000ELCD / PR1500ELCD User s Manual

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

USER MANUAL MPS 1-5KW SERIES

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

UTILITY INPUT MAINS OUTLET

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Uninterruptible Power System

Uninterruptible Power System

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Installation and Operation Manual Back-UPS BX1100CI-CN

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and Operation Back-UPS BX550CI-CN

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

POWERWARE User s Guide VA.

1. Important Safety Warning

User Manual V1.0 MaxiFlex 3000

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

Uninterruptible Power System

400 Watt Backup Power System Owner s Manual

Liebert GXT MT+ User Manual VA Installer/User Guide

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

User Manual. 3kW Hybrid PV Inverter HX-3000

Liebert PSA VA. Installer/User Guide

USER MANUAL DN / DN

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Powerware Vdc Extended Battery Cabinet User s Guide.

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

User s Manual Legend SB825 UPS K

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

User Manual Rittal PMC UPS 6kVA

GSL Electronics Modified Sine Wave Power Inverters

Pulsar Evolution 2200/3000/3000 XL

02/15/01. Powerware User s Guide VA.

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

OWNER S MANUAL POWER INVERTER

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Back-UPS CS Back-UPS CS 350

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

FALCON ELECTRIC, INC.

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

NEWTECH PRO X KVA DSP LCD 1/1 ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

Transcription:

USER MANUAL PowerMust 1400/2000 LCD Uninterruptible Power System

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Power Must 1400/2000 LCD that should be followed during installation and maintenance of the UPS and batteries. Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well as violate local electrical codes. In the event of an emergency, turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hand. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on the top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number of the sealed lead-acid batteries. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. WARNING: This is a UPS Class C2. In residential subdivision the product may cause harmful interference, then the users have to take additional measures.

System Description Front Panel 1. LCD Back-Light 2. Power ON/OFF Switch Back Panel 1. Communication Port(optional) 2. Cooling Fan 3. AC Output 4. Modem/Phone Linesurg Protection 5. Circuit Breaker 6. AC Input

Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 20cm to avoid interference. 3. Charging This unit is shipped from the factory with its internal battery fully charged. however, some energy may be lost during shipping so the battery should be recharged before using it. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for 10 hours.

4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). 5. Modem/Phoneline Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket as shown.

6. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the serial cable as per diagram below. 7. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again (When Swith ONThe LED lighting.). 8. LCD Display Specification The LED will always turns on when UPS works, including in off charging mode and fault mode. When LCD start to work, it will display all information for 3s

1).When in normal mode, it will display as below. 2).When in AVR mode, it will display as below. And the mark flicker every 1second. will 3).When in battery mode, it will display as below. And the mark will flicker every 1second. Note: If I/P-V<40Vinput voltage will display 000 4).When in off charging mode, it will display as below. Note: the output voltage always is displayed as 000 in off charging mode. 5).When in fault mode, it will display as below. FAULT character and the reason of fault only. Note: the fault code will be showed in fault mode.

6).Load level definition: Load LEVEL Load bar Indication 0%~25% 25%~50% 50%~75% 75%~100% 7).Battery capacity definition: Battery LEVEL Battery bar Indication Battery voltage 22V 22V Battery voltage 23V 23V Battery voltage 25V Battery voltage 25V 8).When over load, the mark 9).When battery low, the mark will flicker every 1second. will flicker every 1second.

Software Installation -- WinPower -- WinPower is a brand new UPS monitoring software, which provides user-friendly interface to monitor and control your UPS. This unique software provides safely auto shutdown for multi-computer systems while power failure. With this software, users can monitor and control any UPS on the same LAN no matter how far from the UPS Installation procedure: 1. Go to the website: http://www.ups-software-download.com/winpower.htm 2. Choose the operation system you need and follow the instruction described on the website to download the software. 3. When downloading all required files from the internet, enter the serial No: 511C1-01220-0100-478DF2A to install the software. When your computer restarts, the WinPower software will appear as a green plug icon located in the system tray, near the clock.

Trouble Shooting Use the table below to solve minor UPS installation or operation problems. If any abnormal situations occur that are not listed above,please call service people immediately. Symptom Possible Cause Remedy No LED display on the front panel. 1. Missing battery. 1. Charge battery up to 6 hours. 2. Battery defect. 2. Replace with the same type of battery. 3.When the Input cord isn t electvified and Power switch is not 3. Press the power switch again or elecerity the Input cord pressed. Alarm buzzer Overload of the UPS. Verify that the load matches beeps continuously when AC supply is the UPS capability specified in the specs. normal. When power failure, back-up 1. Overload of the UPS. 1. Remove some noncritical load. time is shorten. 2. Battery voltage is too 2. Charge battery 6 hours or low. more. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 3. Replace with the same type of battery. Communication lost between UPS and computer. 1. Software is not installed well. 2. Cable is not properly connected. 1. Check the setting of the software. 2. Check the RS-232 or USB cable is firmly connected to COM1/COM2 of the computer and confirm the setting again. 1. Reset the circuit breaker.. Mains normal but LCD display 1. Circuit breaker is broken. Battery mode. 2. Power cord is loose. 2. Reconnect the power cord properly.

Specification MODEL Power Must 1400 LCD Power Must 2000 LCD 1 CAPACITY VA/W 1400VA/840W 2000VA/1200W INPUT OUTPUT BATTERY TRANSFER TIME INDICATOR AUDIBLE ALARM PROTECTION PHYSICAL Voltage Voltage Range Voltage Voltage Regulation Frequency Frequency Regulation Output Waveform Battery Type Back up Time Recharge Time Typical LCD Display Models Backup Mode Battery Low Overload Battery replace Fault Full Protection Dimension (WxHxD) (mm) 220/230VAC 166/280VAC 220/230VAC +/- 10%(Battery Mode) 50Hz / 60Hz +/-1 Hz(Battery Mode) Stepped Sine Wave 12V/9Ah*2pcs(24V model) 25 minutes at 200W load 6 Hours to 90% after complete discharge 4-8ms typical, 10ms max The LCD will always turn on when UPS work, Including in off charging mode and fault mode Sounding every 10 seconds Sounding every 1 second Sounding every 0.5 seconds Sounding every 2 seconds Continuous sounding Discharge,Overcharge short circuit and Overload Protection 145* 205 * 399 WEIGHT Net Weight 10.6Kgs 10.8Kgs Operating Environment ENVIRONMENT 0-40 C, 0-90 % Relative Humidity (non-condensing) Noise Level Less than 50dB INTERFACE SmartRS-232 (optional) Windows family, Sun Solaris, IBM Aix, Compaq True64, UnixWare, FreeBSD, HP-UX, Linux and MAC